Loading...
HomeMy WebLinkAboutTRO4103231.3m Q 0) N cd I un 0 0 N 0 0 O 0 w 0 0 Q N O 00 6 z m 0 N N SERVICE CABINET 0 STA. 0+86, 26' RT, HOQUTAM AVE Y SERVICE CABINET I.D. NO. 0097 1 100 AMP w o w s w N CIRCUIT A-1: 20 A BRANCH BREAKER, 40 A CONTACTOR 0 aL o U1 CIRCUIT A-2: 20 A BRANCH BREAKER, 40 A. CONTACTOR F a x w 4.; 0 a 0 U x O H L Q �d 0. O � •� a � �C 3vC Q U �z-w CL H w � c v c I✓ L Jl C E pi 0 0 CIRCUIT A-3: 20 A BRANCH BREAKER, 40 A CONTACTOR CIRCUIT A-4: 20 A BRANCH BREAKER, 40 A CONTACTOR LEGEND FLAT LENS COBRA HEAD, 240 VOLT, HIPS, MEDIUM CUTOFF TYPE III DISTRIBUTION ON DAVIT POLE WITH 8' ARM. POLE SHALL MAINTAIN MIN. 10' CLEARANCE TO ANY DRIVEWAY. WSDOT TYPE II JUNCTION BOX (SEE CITY STD. PLAN #J-11 a). 9+00 - STREET LIGHT GENERAL NOTES: / 1. ALL WORKS SHALL BE IN ACCORDANCE WITH THE CITY OF RENTON STANDARD PLANS AND EXIST. STREET LIGHT ON POWER POLE SPECIFICATIONS AND THESE PLANS. 2. UNLESS OTHERWISE NOTED, THE LOCATION OF FEATURES SHOWN ARE APPROXIMATE AND THE EXACT LOCATION WILL BE ESTABLISHED BY THE ENGINEER OR INSPECTOR IN THE FIELD. 3. INSTALL ALL STREET LIGHTING MATERIALS SHOWN ON THE PLANS, EXCEPT WHERE NOTED. ALL MATERIALS SHALL BE NEW AND OF THE BEST AVAILABLE GRADE OR QUALITY. 4. THE CONTRACTOR SHALL SUBMIT A REQUEST TO THE CITY OF RENTON FOR MATERIALS APPROVAL AT THE EARLIEST POSSIBLE DATE. 5. ALL WORK SHALL BE CONSISTENT WITH UTILITY AGENCY REQUIREMENTS. THE CONTRACTOR SHALL CONTACT ALL PERTINENT UTILITY AGENCIES 48 HOURS BEFORE COMMENCING WORK AND SHALL COORDINATE THE WORK WITH THE UTILITIES THROUGHOUT THE PROJECT. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES. THE CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY COMPANY AND THE CITY IMMEDIATELY UPON DAMAGE. 7. THE CONTRACTOR SHALL NOTIFY THE CITY OF RENTON FIELD INSPECTION DIVISION FOR INSPECTION PURPOSES, 24 HOURS BEFORE COMMENCING WORK. NO WORK SHALL BE COVERED UNTIL IT HAS BEEN EXAMINED BY THE INSPECTOR. 8. ALL CONDUIT SHALL BE PVC SCHEDULE 40 UNLESS OTHERWISE NOTED. 9. ALL CONDUIT COVER SHALL BE 24 INCHES. w STREET LIGHT FLAG NOTES: M � ° a a � 6'x6' RESERVE AREA FOR FUTURE SIGNAL CABINET. STA 0+80, 26' RT. `z .9 z Q o 4' DIAMETER RESERVE AREA FOR FUTURE SIGNAL POLE. STA 0+51, 32' RT. F N_ x 97 INSTALL SERVICE CABINET & CABINET NUMBERS. SEVICE CABLES (3-#2's) AND CONDUIT (2" SCH 80) SHALL CONNECT FROM SERVICE CABINET TO NEAREST P.S.E. POWER SOURCE. - ® INSTALL PHOTOCELL ON LUMINAIRE. N � z z II z z o v z STREET LIGHTING A POLE SCHEDULE POLE POLE POLE POLE MOUNTING WATTS ARM CIRCUIT NO. I.D.# LOCATION OFFSET HEIGHT LENGTH N0, 1 2862B STA 0+86 23' LT 25' 100 8' A-1 2 2863B STA 2+58 23' RT 25' 100 8' A-1 3 2864B STA 4+36 23' LT 25' 100 8' A-1 4 2865B STA 5+76 23' RT 25' 100 8' A-1 5 2867B STA 0+90 25.5' LT 25' 100 8A-2 6 2866B STA 1 +70 25.5' RT 25' 100 8' A-1 " U a 7 2869B STA 2+65 23' LT 25' 100 8' A-1 A 8 2868H STA 7+10 40' LT 40' 400 8' A-2 a 9 2870H STA 5+15 40' LT 40' 400 8' A-2 a 10 2872H STA 3+20 40' LT 40' 400 8' A-2 11 2874H STA 1 +25 40' LT 40' 400 8' A-2 x WIRING SCHEDULE !m RUN NO. CONDUIT SIZE CONDUCTOR COMMENTS ® 2" SCH. 40 4-#8 AWG (USE-XLP) LIGHTING 2-#10 AWG (USE-XLP) PHOTOCELL 1-#8 BARE GROUND GROUND ® 2" SCH. 40 2-#8 AWG (USE-XLP) LIGHTING 2-#10 AWG (USE-XLP) PHOTOCELL 1-#8 BARE GROUND GROUND o ® 2" SCH. 40 OPEN (PULL WIRE) SPARE 'w ® 3" SCH. 40 OPEN (PULL WIRE) SIGNAL ® 3" SCH. 80 OPEN (PULL WIRE) SIGNAL ® 2" SCH. 40 2-#8 AWG (USE-XLP) LIGHTING 20 0 1-#8 REAR GROUND GROUND STREET LIGHT SPECIFICATIONS O Z COMMENTS NE 3rd ST. NE 3rd ST. NE 3rd ST. NE 3rd ST. HOQUIM AVE NE HOQUIM AVE NE HOQUIM AVE NE NE 4th ST. NE 4th ST. NE 4th ST. NE 4th ST. NORTH SCALE: 1" = 20' GRAPHIC SCALE 10 20 40 ( IN FEET ) 1 inch = 20 ft. EL I �� s_ 4,_ . �0' 22.50' �0 JCT BOX i EXIST. STREET LIGHT ON POWER POLE (REMOVE) I I o' 1 29 oIQO 3 27 w I� � I � co o -- 0, J O H\ U TH 11S / N88'22'11"W N88`22'11"W 43.00 47.00 N88°22'11"W — PPI ./- \NAY — ---EEC _`qE( ------� 45.19' �O 6 � N Q0 N w� I 00 31 32 N G) Co00 Qo 20 0 CD 00 N w I f� I N 00 N w---1-----------i------------� O I, -----0 20.00' N I ' 26WIDEN DRIVEWAY 00 o o- 00 N88'22'11 "W ICD N 88°22'11 " W N88'22'11 "V! � O 45.22' 43.00' 4T00' z i AND UTILITIES EASEMENT I I i I —71 I 0 35 34 I Q oLLJI w 33 0 � 0 o �ICD 00 o 0 II o I 45.24' 43.00' L _ _ 47.00' F:� 1 �� k\111 EXPIRES 07-16-2007 5 o �7 #5 0 0 I I I 0 0 Lj+,60.87 Z L`J Q, Q #7 i 6+00 ----- ----- 0 - --- EET LIGHT ON POWER POLE (REMOVE) �I O o I Lw cd I-03 roo I-n I o J EXIST. I z I I HOUSE I I --- -- {--- --- ---- I, — -- --- — -- ---- --- - ---- - ---- ----- ----- 59.50' TO BET- 50.50' ll � REMOVE6 i 2 i CV I w I H 5 1 I W I W wl I Q I NIO I O W I �_���// I VJ 00 LLn ol00 I �� 2 1 I W c 10 zl ,I > I00 I STA 2+15.62 HOQUTAM AVE NE I I00 o l =STA 6+60.87 NE THIRD ST C I O I I I S \\�00------------ -----------+----�---j �s J.50.50' � `46+00 #4 ! I 5-400 NE 3RD N STREET ' I W 5' WIDE CONC. SIDEWALK I Z o0 U Cy O LL J w 0 o I LU o 3 V) 0 _ W 0 O 0 w 0 O z I � I 30' 25' I I �I w + N 00 6) T-B.FI I I RETEN T OIL /DDTEN T O� I POND LUA' 04-031 (SEE 5 H T` 1 1 RECOMMENDED FOR APPROVAL TRACT A BY: ' DATE: IQ - (Z WS DRA ESE BY: DATE: f BY: DATE: S88?22'11 "E 277.56' BY: DATE: ENGINEER: PAKL ING 720 olive Way, Suite 1400 Seattle, Washington 98707-7853 853 " 206-667-0555 800-667-0610 Fax: 206-667-0554 ELECTRICAL ENGINEERING I TECHNOLOGY CONSULTING www.sparling.com ';(ANNED OCT 2 8 2005 N0. REVISION BY APPR. DATE CITY OF' RENTON DEPARTMENT OF PUBLIC WORKS STREET LIGHTING PLAN JERICHO PLAT DESIGNED: CBF DATE: 09/23/05 FILE NAME: DRAWN: AAU CHECKED: CBF SCALE: 1 "=20' FIELD BOOK: PAGE: APPROVED: SHEET: 20 OF: 22 DIRECTOR OF PUBLIC WORKS