SERVICE CABINET 0 STA. 0+86, 26' RT, HOQUTAM AVE
Y
SERVICE CABINET I.D. NO. 0097 1 100 AMP
w
o w
s
w N
CIRCUIT A-1: 20 A BRANCH BREAKER, 40 A CONTACTOR
0
aL
o
U1
CIRCUIT A-2: 20 A BRANCH BREAKER, 40 A. CONTACTOR
F
a
x
w
4.; 0
a 0
U
x
O
H
L
Q �d
0.
O
� •�
a
� �C
3vC Q
U
�z-w
CL
H
w
� c
v
c I✓
L
Jl
C
E
pi
0
0
CIRCUIT A-3: 20 A BRANCH BREAKER, 40 A CONTACTOR
CIRCUIT A-4: 20 A BRANCH BREAKER, 40 A CONTACTOR
LEGEND
FLAT LENS COBRA HEAD, 240 VOLT, HIPS, MEDIUM CUTOFF TYPE
III DISTRIBUTION ON DAVIT POLE WITH 8' ARM. POLE SHALL
MAINTAIN MIN. 10' CLEARANCE TO ANY DRIVEWAY.
WSDOT TYPE II JUNCTION BOX (SEE CITY STD. PLAN #J-11 a).
9+00 -
STREET LIGHT GENERAL NOTES: /
1. ALL WORKS SHALL BE IN ACCORDANCE WITH THE CITY OF RENTON STANDARD PLANS AND EXIST. STREET LIGHT
ON POWER POLE
SPECIFICATIONS AND THESE PLANS.
2. UNLESS OTHERWISE NOTED, THE LOCATION OF FEATURES SHOWN ARE APPROXIMATE AND THE
EXACT LOCATION WILL BE ESTABLISHED BY THE ENGINEER OR INSPECTOR IN THE FIELD.
3. INSTALL ALL STREET LIGHTING MATERIALS SHOWN ON THE PLANS, EXCEPT WHERE NOTED. ALL
MATERIALS SHALL BE NEW AND OF THE BEST AVAILABLE GRADE OR QUALITY.
4. THE CONTRACTOR SHALL SUBMIT A REQUEST TO THE CITY OF RENTON FOR MATERIALS APPROVAL
AT THE EARLIEST POSSIBLE DATE.
5. ALL WORK SHALL BE CONSISTENT WITH UTILITY AGENCY REQUIREMENTS. THE CONTRACTOR
SHALL CONTACT ALL PERTINENT UTILITY AGENCIES 48 HOURS BEFORE COMMENCING WORK AND SHALL
COORDINATE THE WORK WITH THE UTILITIES THROUGHOUT THE PROJECT.
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES. THE
CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY COMPANY AND THE CITY IMMEDIATELY UPON
DAMAGE.
7. THE CONTRACTOR SHALL NOTIFY THE CITY OF RENTON FIELD INSPECTION DIVISION FOR
INSPECTION PURPOSES, 24 HOURS BEFORE COMMENCING WORK. NO WORK SHALL BE COVERED UNTIL
IT HAS BEEN EXAMINED BY THE INSPECTOR.
8. ALL CONDUIT SHALL BE PVC SCHEDULE 40 UNLESS OTHERWISE NOTED.
9. ALL CONDUIT COVER SHALL BE 24 INCHES.
w
STREET LIGHT FLAG NOTES:
M �
°
a a
� 6'x6' RESERVE AREA FOR FUTURE SIGNAL CABINET. STA 0+80, 26' RT.
`z
.9
z Q
o
4' DIAMETER RESERVE AREA FOR FUTURE SIGNAL POLE. STA 0+51, 32' RT.
F
N_
x
97
INSTALL SERVICE CABINET & CABINET NUMBERS. SEVICE CABLES (3-#2's) AND CONDUIT
(2" SCH 80) SHALL CONNECT FROM SERVICE CABINET TO NEAREST P.S.E. POWER SOURCE.
-
® INSTALL PHOTOCELL ON LUMINAIRE.
N
� z z
II
z z o
v
z
STREET LIGHTING
A
POLE SCHEDULE
POLE POLE POLE POLE MOUNTING WATTS ARM CIRCUIT
NO. I.D.# LOCATION OFFSET HEIGHT LENGTH N0,
1 2862B STA 0+86 23' LT 25' 100 8' A-1
2 2863B STA 2+58 23' RT 25' 100 8' A-1
3 2864B STA 4+36 23' LT 25' 100 8' A-1
4 2865B STA 5+76 23' RT 25' 100 8' A-1
5 2867B STA 0+90 25.5' LT 25' 100 8A-2
6 2866B STA 1 +70 25.5' RT 25' 100 8' A-1
"
U
a
7 2869B STA 2+65 23' LT 25' 100 8' A-1
A
8 2868H STA 7+10 40' LT 40' 400 8' A-2
a
9 2870H STA 5+15 40' LT 40' 400 8' A-2
a
10 2872H STA 3+20 40' LT 40' 400 8' A-2
11 2874H STA 1 +25 40' LT 40' 400 8' A-2
x
WIRING SCHEDULE
!m
RUN NO. CONDUIT SIZE CONDUCTOR COMMENTS
® 2" SCH. 40 4-#8 AWG (USE-XLP) LIGHTING
2-#10 AWG (USE-XLP) PHOTOCELL
1-#8 BARE GROUND GROUND
® 2" SCH. 40 2-#8 AWG (USE-XLP) LIGHTING
2-#10 AWG (USE-XLP) PHOTOCELL
1-#8 BARE GROUND GROUND
o
® 2" SCH. 40 OPEN (PULL WIRE) SPARE
'w
® 3" SCH. 40 OPEN (PULL WIRE) SIGNAL
® 3" SCH. 80 OPEN (PULL WIRE) SIGNAL
® 2" SCH. 40 2-#8 AWG (USE-XLP) LIGHTING 20 0
1-#8 REAR GROUND GROUND
STREET LIGHT SPECIFICATIONS
O
Z
COMMENTS
NE
3rd
ST.
NE
3rd
ST.
NE
3rd
ST.
NE
3rd
ST.
HOQUIM
AVE NE
HOQUIM
AVE NE
HOQUIM
AVE NE
NE
4th
ST.
NE
4th
ST.
NE
4th
ST.
NE
4th
ST.
NORTH
SCALE: 1" = 20'
GRAPHIC SCALE
10 20 40
( IN FEET )
1 inch = 20 ft.
EL
I �� s_
4,_ . �0' 22.50' �0
JCT BOX i
EXIST. STREET LIGHT
ON POWER POLE (REMOVE)
I
I
o' 1
29
oIQO
3
27
w
I�
�
I
�
co
o
-- 0, J O H\
U TH 11S /
N88'22'11"W
N88`22'11"W
43.00
47.00
N88°22'11"W
—
PPI ./- \NAY
—
---EEC _`qE(
------�
45.19'
�O
6
�
N
Q0
N
w�
I
00
31
32
N
G)
Co00
Qo
20
0
CD
00
N
w
I
f� I
N
00
N
w---1-----------i------------�
O I,
-----0
20.00'
N
I
'
26WIDEN
DRIVEWAY
00 o
o-
00
N88'22'11 "W
ICD
N 88°22'11 " W
N88'22'11 "V!
� O
45.22'
43.00'
4T00'
z
i
AND UTILITIES
EASEMENT
I
I
i
I
—71
I
0 35
34
I
Q
oLLJI
w
33
0
�
0 o
�ICD
00
o 0
II
o
I
45.24'
43.00'
L _ _ 47.00'
F:�
1 �� k\111
EXPIRES 07-16-2007
5
o �7
#5
0
0
I
I
I
0
0
Lj+,60.87
Z
L`J
Q,
Q #7
i
6+00
----- -----
0
- --- EET LIGHT
ON POWER POLE (REMOVE)
�I
O
o I
Lw
cd
I-03
roo
I-n I o J
EXIST. I z I I
HOUSE
I I
--- -- {--- --- ----
I,
— -- --- — -- ---- --- - ---- - ---- ----- -----
59.50' TO BET- 50.50'
ll �
REMOVE6 i 2 i CV
I w I H
5 1
I W
I W
wl
I
Q I
NIO
I O
W I
�_���//
I VJ
00 LLn
ol00
I ��
2 1
I W
c
10 zl
,I
>
I00
I
STA 2+15.62 HOQUTAM AVE NE
I I00
o l
=STA 6+60.87 NE THIRD ST
C
I O
I
I
I
S
\\�00------------
-----------+----�---j
�s
J.50.50'
�
`46+00 #4
!
I
5-400
NE 3RD N STREET
'
I
W
5' WIDE CONC. SIDEWALK
I Z
o0
U
Cy
O
LL
J
w 0
o I
LU
o
3
V)
0
_
W
0
O
0
w
0
O
z
I
�
I
30' 25'
I
I
�I
w
+
N
00
6)
T-B.FI
I
I
RETEN T OIL /DDTEN T O�
I
POND
LUA' 04-031
(SEE 5 H T` 1 1 RECOMMENDED FOR APPROVAL
TRACT A BY: ' DATE: IQ - (Z WS
DRA ESE
BY: DATE: f
BY: DATE:
S88?22'11 "E 277.56' BY: DATE:
ENGINEER:
PAKL ING 720 olive Way, Suite 1400
Seattle, Washington 98707-7853
853
" 206-667-0555 800-667-0610
Fax: 206-667-0554
ELECTRICAL ENGINEERING I TECHNOLOGY CONSULTING www.sparling.com
';(ANNED OCT 2 8 2005
N0. REVISION BY APPR. DATE
CITY OF' RENTON
DEPARTMENT OF PUBLIC WORKS
STREET LIGHTING PLAN
JERICHO PLAT
DESIGNED: CBF DATE: 09/23/05 FILE NAME:
DRAWN: AAU
CHECKED: CBF SCALE: 1 "=20' FIELD BOOK: PAGE:
APPROVED: SHEET: 20 OF: 22
DIRECTOR OF PUBLIC WORKS