HomeMy WebLinkAboutWTR2703234.10 Lr) o o 0 0 N � (D Of :2 . 00 Q Q C) UJI 0 Z Z 0 � U W Q 4_ U z 0 z w � �to � d ta Y o Q Q 'K � ¢ i `° o i .r LLj two 4 �Z a a Q Ld Q Q z 0 w ry WATER UTILITY - GENERAL NOTES 1. ALL WORK MATERIALS SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON UTILITY DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED BY THE CITY OF RENTON. A SET OF APPROVED PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION. 2. THE HOURS OF WORK /N THE STREET RIGHT-OF-WAY SHALL BE LIMITED TO 8: 30 AM TO 3: 30 PM ON WEEKDAYS UNLESS OTHERWISE APPROVED /N WRITING BY THE DEPARTMENT OF PUBLIC WORKS AT 235-2635. ALL STREET CLOSURES, PARTIAL OR FULL, SHALL BE APPROVED BY THE DEPARTMENT OF PUBLIC WORKS 24 HOURS IN ADVANCE. THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911 SHALL BE NOTIFIED 24 HOURS /N ADVANCE. J. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. FOR UTILITY LOCATE CALL 48 HOUR LOCATORS, 1- 800- 424-5555. 4. ALL WA TER' MAIN PIPE TO BE CEMENT LINED DUCTILE IRON PIPE CONFORMING TO AWWA C110 AND C111 OR LATEST REWS/ON, THICKNESS CLASS 52. CEMENT MORTAR LINING AND SEAL COATING SHALL CONFORM TO AWWA C104 OR LATEST REVISION. PIPE JOINTS TO BE PUSH -ON OR MECHANICAL JOINT. BEDDING TO BE CLASS C. ALL DUCTILE IRON PIPE SHALL BE POLYETHYLENE WRAPPED PER ANSI/AWWA C 105- 77 STANDARDS. 5. CAST IRON AND DUCT/LE IRON FITTINGS SHALL BE CEMENT LINED, PRESSURE RATED AS NOTED ON PLANS, AND IN ACCORDANCE WITH ANSI/AWWA C110/A21.10-82. CEMENT LINING SHALL BE /N ACCORDANCE WITH ANSI/AWWA C104/A21.4-85. IF FITTINGS ARE 3 INCHES TO 12 INCHES IN DIAMETER AND HAVE MECHANICAL JOINTS, THE FITTINGS SHALL BE /N ACCORDANCE WITH EITHER ANSI/AWWA C11 O/A21.10- 82 OR ANSI/AWWA C153/A21.53-84. 3-INCH TO 12-INCH DIAMETER FITTING WHICH HAVE MECHANICAL JOINTS AND/OR FLANGED JOINTS SHALL BE /N ACCORDANCE WITH ANSI/AWWA C110/A21.10-82 OR A COMBINATION OF ANSI/AWWA C110/A21.10.82 AND ANSI/AWWA C153/A21.53-84 SUCH THAT THE PORTION OF THE FITTING WITH A MECHANICAL JOINT(S), MAY BE IN ACCORDANCE WITH ANSI/AWWA C153/A21.53-84 AND THAT PORTION OF THE FITTING WTH FLANGED JOINT(S) SHALL BE IN ACCORDANCE WITH ANSI/AWWA C110/A21.10- 82. ACCEPTANCE TESTING /N ACCORDANCE WITH SECTION 53-5.3 OF ANSI/AWWA C153/A21.53-84 OR WITH SECTION 10-4.3 OF ANSI/AWWA C110/A21.10-82 SHALL BE OBTAINED BY THE CONTRACTOR AND TRANSMITTED TO THE OWNER. 6. GA TE VAL VES SHALL CONFORM TO AWWA C500 AND SHALL BE IRON BODY, BRONZED -MOUNTED, DOUBLE DISC WITH BRONZE WEDGING DEVICE AND O-RING STUFFING BOX. VALVES SHALL BE DESIGNED FOR A MINIMUM WATER OPERATING PRESSURE OF 200 PSI. GATE VALVES SHALL BE CLOW LIST 73, MUELLER COMPANY MG. A2J6a,, OR M & H. ALL VALVES 12" IN DIAMETER AND LARGER, SHALL BE INSTALLED IN A VAULT. SEE WATER STANDARD DETAIL FOR 12" GATE VALVE ASSEMBLY VAULT AND 1" BYPASS INSTALLATION. 7. FIRE HYDRANTS SHALL BE COREY TYPE (OPENING WITH THE PRESSURE) CONFORMING TO AWWA C-504-80 WITH A 6 INCH INLET AND A M. V. O. OF 5 INCHES, TWO 2-1/2 INCH HOSE NOZZLES WITH NATIONAL STANDARD 7 INCH, 60 DEGREES V. THREADS, O.D. THREAD 4.875 AND ROOT DIAMETER 4.6263, 1-1/4 INCH PENTAGON OPERATING NUT OPENED BY TURNING COUNTER CLOCKWISE (LEFT). 8. ALL WATER MAIN 10 INCHES AND SMALLER TO MAINTAIN A MINIMUM COVER OF 36 INCHES BELOW FINISH GRADE. ALL WATER MAIN 12 INCHES AND LARGER SHALL BE AT A MIN/MUM OF 48 INCHES BELOW FINISH GRADE. WHERE UTILITY CONFLICTS OCCUR, WATER MAINS ARE TO BE LOWERED TO CLEAR. 9. ALL WATER MAINS SIX (6) INCHES /N DIAMETER AND LARGER SHALL BE CLEANED WITH PIPE CLEANING "PIGS" PRIOR TO DISINFECTION. THE "POLY PIGS" SHALL BE GIRARD INDUSTRIES AQUA SWAB -AS OR APPROVED EQUAL 2 LB\CU FT DENSITY FOAM WITH 90A DUROMETER URETHANE RUBBER COATING ON THE REAR OF "PIG" ONLY "PIGS" SHALL BE CYLINDER SHAPED WITH BULLET NOSE OR SQUARE END. THE CONTRACTOR WILL PREFORM THE CLEANING OPERA TION. 9A. ALL WATER MAINS AND SERVICES SHALL BE PRESSURE TESTED TO A MINIMUM OF 200 PSI OR 150 PSI OVER OPERATING PRESSURE, IN ACCORDANCE WITH THE SPECIFICATIONS OF THE CITY OF RENTON AND THE WASHINGTON STATE HEALTH DEPARTMENT. ALL PRESSURE TESTING SHALL BE DONE LN THE PRESENCE OF A REPRESEN TA T/ VE OF THE Cl TY OF REN TON. 98. ALL WATER MAINS AND SERVICES SHALL BE DISINFECTED BY THE INJECTION OF A 50 PPM (MINIMUM CONCENTRATION) CHLORINE/WATER SOLUTION. DRY CALCIUM HYPOCHLOR/TE SHALL NOT BE PLACED /N THE PIPE AS LAID. CHLORINE SHALL BE METERED/INJECTED /N ACCORDANCE WITH SECTION 7-11.3(12)E OR 7-11.3(12)F OF THE STANDARD SPECIFICATIONS REFERENCED IN 1 ABOVE. 10. A PRECONSTRUCTION CONFERENCE IS REQUIRED PRIOR TO ANY CONSTRUCTION. A MINIMUM OF 3 (THREE) WORKING DAYS NOTICE IS REQUIRED FOR SCHEDULING. PRIOR TO SCHEDULING THE PRECON A PERMIT INFORMATION SHEET MUST BE SUPPLIED TO THE UTILITY ENGINEER'S OFFICE. TWENTY-FOUR HOUR NOTICE WILL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. 11. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. 12. INSTALLAT70M OF CORPORATE STOPS, WATER SERVICES, LINES AND METERS SHALL NOT BE DONE UNTIL ALL SERVICE AGREEMENTS, METER APPLICATIONS, CONSTRUCTION PERMITS, AND PA YMENT OF FEES HA VE BEEN MADE TO THE Cl TY OF REN TON. 13. ALL CONNECTION TO EXISTING MAINS TO ACCOMPLISHED BY THE CITY OF RENTON, EXCEPT WET TAPS WHICH MAY BE MADE BY APPROVED WET TAP CONTRACTORS WITH PRIOR APPROVAL FROM THE DEPARTMENT OF PUBLIC WORKS. ALL NECESSARY EXCAVATION AND MATERIALS TO BE SUPPLIED BY THE CONTRACTOR AND BE ON -SITE PRIOR TO CITY NOTIFICATIONS. 14. INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTA TI VE OF THE CITY OF RENTON. IT SHALL BE THE CONTRACTOR'S ,RESPONSIBILITY TO NOTIFY THE UTILITY DEPARTMENT 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. THE CONTRACTOR AS WELL AS THE ENGINEERS SHALL KEEP AS -BUILT DRA WINGS. 15. CONTRACTOR TO PROVIDE PLUGS AND TEMPORARY BLOW -OFF ASSEMBLIES FOR TESTING AND PURITY ACCEPTANCE PRIOR TO FINAL TIE-IN. 16. ALL JOINT RESTRAINT SYSTEMS (SHACKLE RODS, NUTS, BOLTS, ETC.) SHALL BE AS MANUFACTURED BY THE STAR MANUFACTURING COMPANY OF COLUMBUS OHIO OR EQUAL APPROVED /N WRITING BY THE DEPARTMENT OF PUBLIC WORKS. 17. ASPHALT AND CONCRETE STREET PAVING SHALL BE SA WCU T TO A MINIMUM DEPTH OF TWO INCHES. OIL MAT STREETS MA YH BE SPADE CUT. ALL SURFACE CONCRETE, PAVEMENT, SIDEWALKS, CURB, GUTTERS, AND DR/ VEWA Y APPROACHES SHALL BE SA WCU T TO A MINIMUM DEPTH OF TWO INCHES OR REMOVED TO AN EXISTING EXPANSION JOINT. 18. A TEMPORARY COLD MIX ASPHALT PATCH SHALL BE PLACED ON THE DAY OF INITIAL EXCAVATION WITH A PERMANENT, SEALED PATCH TO BE PLACED, TO CITY OF RENTON POLICY, WITHIN TEN DAYS. CALL FOR SUBGRADE INSPECTION PRIOR TO PLACEMENT OF FINAL PATCH. TRENCHES WILL NOT BE LEFT OPEN OVER NIGHT WITHOUT PRIOR WRITTEN APPROVAL OF THE INSPECTOR. 19. FOR CITY PROJECTS SUCH AS TELEMETRY CONDUIT, THE PVC PIPE USED SHALL BE SCHEDULE 40 IN UNIMPROVED AREAS AND SCHEDULE 80 UNDER IMPROVED AREAS. ALL CHEMICAL PROCESS LINES SHALL BE SCHEDULE 80 PVC PIPE. Z 8" VERTICAL CROSS (MJxFL) 1 - 8" PLUG (MJ) WITH 2" TAP & 2" TEMP. BLOW -OFF ASSEMBLY °o 1 - 8" BLIND FLANGE(BOTTOM) 1 - 8" BLIND FLANGE(TOP) WITH 2" TAP & 2" PLUG TEMPORARY BLOCKING 1 - 8" PLUG (MJ) WITH 2" TAP & 2" TEMP. BLOW -OFF ASSEMBLY A i 8„ PIPE C,n) STA PER EW INTX NE 24TH STREET A T BL E A VE NE 8"X $" ICE C.MS,�FL) STA +12-7. 'RT TEST CONNECTION 8 xt TEEM xFL)-EX. RFMO E16"GV 1.- 80 G.Y. (. MsX KS) INST, 2- ArA M 3 CUI Tn Ac,) INCR, 1-8" AS -BUILT CERTIFICATE F HEREBY CERTIFY THAT THE HORIZONTAL AND VERTICAL LOCATIONS OF THE STORM FACILITIES AND PAVING SHOWN HEREON ARE THE RESULT OF A FIELD SURVEY PERFORMED BY ME OR UNDER MY DIRECTION, AND ADDITIONAL INFORMATION SUPPLIED BY THE CONTRACTOR. Z 0 Q it m AFTER POL YPIGGING, PRESSURE & PURITY TEST, REMOVE TEMP. PLUGS, BLOCKING, AND CONNECT W/8" SOLID SLEEVE (MJ) X 8"A-PIPE NE 24 TH STREET FINAL CONNECTION NOTES CONNECTION DETAIL 1. CONTRACTOR TO POTHOLE EXISTING WATERMAIN AT CONNECTION LOCATIONS. 2. CITY STAFF WILL MAKE ALL FINAL CONNECTIONS TEMPORARY 2" GALVANIZED PIPE lN�ii►U ` QuuD CLAW156 AND 2" GATE VALVE- FINISHED GRADE INSTALL 2" PLUG ON TOP BLIND FLANGE AFTER REMOVAL OF POLYPIG 3 FT MIN. COVER (10" DIA PIPE AND UNDER) 4 FT MIN COVER (12" DIA. PIPE AND OVER) NEW WA TER MAIN POL YPIG VER 7/CAL CROSS FOR POL WIGGING S TA TION. SIZE OF VERVCAL CROSS SHALL BE SAME SIZE AS PIPE MAIN VERTICAL CROSS (MJXFL) ONE BLIND FLANGE ON TOP OF CROSS WITH 2" TAP & 2" TEMPORARY BLOW -OFF -ASSEMBLY (REMOVE BLOW -OFF ASSEMBLY AND INSTALL 2" PLUG AFTER REMOVAL OF CLEANING "POLY -PIG") ONE BLIND FLANGE ON TOP OF CROSS ONE PLUG (MJ) ON END OF CROSS CONCRETE BLOCKING ALL DEBRIS AND POL YP/GS SHALL BE REMOVED FROM SUMP OF VER77CAL CROSS BEFORE DISINFECTION OF THE NEW WA TER MAIN. MAIN 2" CLOSE NIPPLE 2" 90` ELBOW CONCRETE BLOCKING TWO PIECE CAST IRON VALVE EQUAL TO OLYMPIC FOUNDRY CO. STANDARD 8" TOP SECTION, WITH REGULAR BASE SECTION LENGTH TO FIT. 2" GATE VALVE, SCREWED 2" GALVANIZED PIPE 12" LONG 2" CLOSE NIPPLE BETWEEN CAP OR PLUG AND 2" 90, ELBOW INSTIL 4 MIL POLYETHYLENE PLASTIC COVER OVER WASHED GRAVEL. CUT HOLE FOR PIPE 36" MIN COVER IF ADDITIONAL ADJUSTMENT IS REQUIRED, INSTALL 2-2" CLOSE NIPPLE AND 2-2" 90' BEND, SCREWED AT THIS POINT. FIELD LOCATE CONCRETE METER BOX 2" CLOSE NIPPLE 2" 90` ELBOW i 2" GALVANIZED PIPE AS REQUIRED PLAN VALVE NUT EXTENSION AS REQUIRED - CONCRETE SIDEWALK (SEE DWG BR46 / PAGE B090) �I 6" MAX. FUND LINE A 2-1 /2" NST (HOSE) BLOW -OFF HYDRANT EQUAL TO #78 KUPFERLE FOUNDRY CO. Z x27 x LL7 TEE_ 2" CLOSE NIPPLE BEWTEEN TEE AND 90` ELBOW. 2" 90° ELBOW 2" GALVANIZED PIPE 000 0 o a0 0 18" LONG o�� o o� o 000.0 O Q0 18" MAX. 00 . 000 0 0, o�oa °aoe°ao� o 00 0 000 .a9onpo o 0 0 o 10 CU. FT. WASHED GRAVEL PASSING 2" CAP WITH 1 /8" 1-1/2" AND RETAINED ON 1/4" MESH TAP FOR DRAIN FOR DRAIN ELEVATION PERMANENT 2" BLOW -OFF ASSEMBL Y DRA WING BR25A 12"x 22" CONCRETE METER BOX WITH 3/16" STEEL DIAMOND PLATE COVER EQUAL TO FOG TITE METER SEAL CO. B-10 METER BOX. (DRILL 1-3/4"DIA. HOLE SEE DETAIL A -A) 6" MIN FINISH GRADE 9" MAX ' 9>. 21 MIN COVER NEW DUCTILE IRON LOOP DOWN TO CENTERLINE WATERMAIN OF WATER MAIN TO PROVIDE SLACK IN COPPER SERVICE LINE TO METER. CORPORATION STOP. FORD TAPERED THREAD (CC). PACK JOINT r 3/4" F1000) (1 F1000) EXISTING CAST IRON OR DUCTILE IRON WATERMAIN FIRE HYDRANT SHALL BE COREY-TYPE EQUAL TO IOWA F-5110 OR COMPRESSION TYPE SUCH AS CLOW MEDALLION; M & H 929 AND MUELLER SUPER CENTURION 200 WITH 6" MECHANICAL JOINT INLET WITH LUGS. 5-1/4" MAIN VALVE OPENING. TWO 2-1/2" HOSE CONNECTIONS NATIONAL STANDARD THREADS. 4" PUMPER CONNECTION CITY OF MAX 4"--1 SEATTLE THREADS WITH A STORTZ ADAPTOR, 4" SEATTLE THREAD MIN 2 X 5" STORTZ, ATTACHED WITH 1 /8" STAINLESS STEEL CABLE. �. 1-1/4" PENTAGON OPERATING NUT. FIRE HYDRANT TO BE ,\ PAINTED WITH TWO COATS OF PAINT. PRESERVATIVE LEVEL ALL GROUND PAINT No. 43-655 SAFETY YELLOW OR APPROVED EQUAL. \\\ MIN 3' RADIUS PUMPER CONNECTION TO FACE ROADWAY ASSEMBLY. FIRE HYDRANT EXTENSION TO BE USED IF REQUIRED. \\ CONCRETE BLOCKING '\ 1 5" STORTZ 6 1 LEVEL ALL GROUND \ 1 MIN 3' RADIUS \ ONE MAN ROCK 6 \\\ CUT r', HYDRANT LOCATION IN CUT OR FILL -1/2` T- R SERVICE FROM _ :ISTING STEEL ASBESTOS CEMENT OR PVC WATER MAINS INSTALL DOUBLE STRAP SERVICE CLAMP EQUAL TO MUELLER CO. IN UNIMPROVED RIGHT OF WAY z INSTALL METER BOX AT Z PROPERTY LINE. W w cr SIDEWALK a WATER METER TO BE 12" M I N SUPPLIED BY THE CITY /- TYPE "K" SOFT COPPER TUBING FORD COPPERSETTER VH 72-15W-44-33G FOR 5/8" x 3/4" METER) VH 72-15W-44-44G FOR 1" METER) BOTH INLET AND OUTLET WITH PACK JOINT WITH GRIPPER. PADLOCK WINGS ON KEY VALVE SINGLE CHECK VALVE ON OUTLET. 7 ALL PACK -JOINT FITTINGS SHALL BE WITH GRIPPER, IF SERVICE LINE TO HOUSE IS TO BE INSTALLED IN THE FUTURE INSTALL FORD C14-33 OR 44 FIDT x COMPRESSION COUPLING A -A DRILL 1-3/4" DIA HOLE FOR NOTE.TOUCHREAD DEVICE THE CENTER OF THE HOLE MUST BE AT LEAST 1' 2-1/2" MIN FROM NEAREST FROM UNDERNEATH RIBS AND FRONT EDGE OF PIT LID UNLESS THE RIB SPACING ALLOWS THE NUT TO F TIGHTEN AGAINST THE OPEN TYPICAL RIB SIDE OF MORE THAN ONE RIB. 3/40 10 WATER SERVICE 36" MIN CO`. EF 3/4" OR 1" GALVANIZED PLUG j---18" TO 20" BEHIND BACK OF CURB &Jma323 OR 12" BEHIND BACK OF SIDEWALK THAT IS ADJACENT TO CURB ZR H. TWO-PIECE CAST IRON VALVE BOX WITH LUG TYPE COVER. ���� of WA EQUAL TO OLYMPIC FOUNDRY CO. STANDARD 8 TOP SECTION WITH ; AS GREQUIRED (SEEULAR BASE CDWG BR46T/ LENGPAGETB090). E NUT EXTENSION 1 RAISED PAVEMENT MARKER TYPE 88 A8 9470 ZZ STIMSONITE TWO-WAY BLUE. Is' slo7va 1 42" MIN EXPIRES 6��22/07 N BURYt REC❑MMENDED FOR APPR❑VAL CONCRETE BLOCKING BY CAST IRON TEE. WITH 6" FLANGE SIDE OUTLET. BY 6" GATE VALVE (FL X MJ) AWWA C-509, RESILIENT SEAT BY ti 6" DUCTILE IRON PIPE, CLASS 52 CEMENT LINED, LENGTH TO FIT TWO 3/4" BY STEEL TIE RODS. SEE STD DETAIL FOR TIE RODS. BY 16" x 8" x 4" MININUM -f CONCRETE BLOCK UNDER HYDRANT \-1/3 CU. YD. WASHED DRAIN ROCK (3" TO 3/8") FIRE HYDRANT ASSEMBLY DATE DATE DATE DATE DATE DRwm W. 87101 WDT. DWG sHEU 4 c OP e j JAITIE 0 z IVnt - i % - P-0 0 W SCANNED OCT 2 7 1.00E