HomeMy WebLinkAboutWTR2703239.10'Aw _ EXISTING REST EXISTING REST ROOM BUILDING ROOM BUILDING APPROXIMATE LOCATION OF PROPOSED GENERATOR : BUILDING EJB ��"' PER RFI-055, HALF STREET BOOSTER PUOMP STATION -' a 0 30® OVERLAY WAS ELIMINATED FROM APPROXIMATE LOCATION OF THE CONTRACT EXISTING NORTH TALBOT — y TELEMETRY PANEL. CENTERLINE OF PROPOSED POWER AND SIGNAL I EXISTING UTILITY POLE. TERMINATION OF PRIMARY SERVICE AT EXISTING UTILITY POLE BY P.S.E. APPROXIMATE LOCATION OF PROPOSED UNDERGROUND PRIMARY SERVICE CONDUIT. L5 HALF STREET OVERLAY. SEE APPENDIX A' APPROXIMATE LOCATION OF CONDUITS TO EXISTING BOOSTER PUMP STATION \ wv i FOR CITY OF RENTON STANDARD PATCH TRANSFORMER VAULT. SEE DWG NO. E03 FOR EXISTING NORTH TALBOT °` lg \ EH _ SWITCHBOARD. -. N, � _ .� AND OVERLAY FOR FLEXIBLE PAVEMENT. CONDUIT AND CONDUCTOR REQUIREMENTS. �_- . �_ MN — — — — — G C� — .. iR PP 2 %$j g WPM to b' �j *• c 9b WV wv 19� S t`U TH i 3TH T i3 G ��' :e� _ __ GA PP GA = _ — i - _ F wv wv w - --� 197 20" wMH r � — — GPik --- _ _MB — _ Gp ry ---- _ -- _ b Y -- — — _ — _ 0 Y PROVIDE STORM DRAIN INLET 70' _--_---_ - .- — — - PROTECTION PER DETAIL ON _ _ DWG N0. cat (TYP OF 2). Al/ _ _. �- I _ --�, --_- 19> 1-0" MIN. -�� PROPOSED SIGNAL .� 99 a� FH ' I I =r �� HANDHOLE AND VAULT `�S` TBM "B'=180.40' ..OWFp wM �; ! PROPOSED POWER (MAG NAIL W/WASHER). REF. HANDHOLE AND VAULT PER �p� EXISTING SERVICE TRANSFORMER. CONSTRUCTION STAGING AREA. / /�\\ �� \\ ' I COP-013 CONTRACTOR SHALL RESTORE AREAS SEE PICTURE 4 THIS SHEET. / / \\ \\ „ \ \\ F EFFECTED B , CONSTRUCTION WHICH ARE EXISTING UTILITY/ /I // 6 p� ; �-� OUTSIDE OF THE PROPOSED LANDSCAPING POLE. TERMINATION / // \\ 1 o„p // \\ � �� � 12 -0„ WI ASPHALT AREA TO EQUAL OR BETTER CONDITION. OF PRIMARY // // \\ �\ ,� r DRIVEWAY PE TAIL SERVICE AT ® ,! / // \�\ // \\ �I �� SEE DWG NO. CONCRETE ENCASED CONDUIT (TYPICAL). EXISTING UTILITY ! / // V// % PROVIDE APPROX. 65 LF OF SILT POLE BY P.S.E. ! \ /` / \\�/ li-====____==___=_ ----------------_ =i� FENCE. SEE APPENDIX D FOR DETAIL. NORTHEAST CORNER OF PROPOSED /\\ PROPOSED BUILDING: 1 i� PROPOSED GENERATOR BUILDING. UNDERGROUND ! / 5 N 171790.07 f PRIMARY POWER �, <\ 0 E 1300108.79 II } SERVICE SIDEWALK. SEE DWG NO. S07 FOR DETAIL. 0 II ,1 t t 1R -o- PPT J / lJ / f .7 r\ / ! WSP :XISTING WATER MAIN, 1, APPROX. 20' DEEP \T_R \_ (L� N88'32 49 W ■ ' a ROADWAY RESTORATION PER PROPOSED PAD -MOUNT j CITY STANDARD DETAIL H032.1. UTILITY TRANSFOPMFP ® i SEE APPENDIX FOR DETAIL. NOTE: - CONTRACTOR SHALL MAINTAIN ACCESS TO PARK DURING CONSTRUCTION, - SEE DWG NO. CO2 FOR TESC NOTES APPLICABLE TO THIS PROJECT SITE. I SOUTHEAST CORNER OF PROPOSED BUILDING: REMOVE N 171767.40 APPROXIMATELY I ! E 13'00151.46 25 LF OF OF EXTRUDED CURB CLEARING LIMITS. PER CCD-006, INSTALL CURB PER RFI-003, THE FENCE IS A ALONGa�(.3) SIDES TO RETAIN p�RMANENTOFENCE & NOT A "— CONSTRUCTION LIMITS. ° TBM "A"=201.65' (REBAR W/CAP). PROPOSED UNDERGROUND -- POWER SERVICE SECOND =.. SURVEY CONTROL DEFINITION HORIZONTAL DATUM: NAD 83/91 DATUM ESTABLISHED BY HOLDING THE PUBLISHED COORDINATES AT CITY OF RENTON SURVEY CONTROL MONUMENTS #S 230, 612, 1160 AND 1882. NOTE: COORDINATES ASSOCIATED WITH THIS DRAWING ARE WASHINGTON STATE PLANE, NORTH ZONE, GRID COORDINATES DETERMINED BY HOLDING THE GRID COORDINATE AT CITY OF RENTON SURVEY CONTROL POINT # 1882, THE DISTANCES SHOWN ON THIS DRAWING ARE GROUND DISTANCES. TO CONVERT THE DISTANCES SHOWN ON THIS DRAWING TO STATE PLANE GRID DISTANCES MULTIPLY THEM BY THE COMBINED FACTOR OF 1.00000140801. BENCHMARKS: LABEL NORTHING EASTING ELEVATION TBM "A" (REBAR W/CAP) 171738.02 1300078.27 201.65' TBM "B" (MAG WASHER) 171845.33 1300459.36 180.40' THE INFORMATION SHOWN ON THIS PLAN IS A COMPILATION FROM TRIAD ASSOCIATES, JULY 2005. THE CONTRACTOR MAY FIND VARIATIONS BETWEEN ACTUAL FIELD CONDITIONS AND THOSE SHOWN ON THE PLANS. THE CONTRACTOR SHALL VERIFY THE LOCATION OF EXISTING UTILITIES PRIOR TO CONSTRUCTION. h HANDHOLE AND VAULT ELECTRICAL NOTES 1. ALL PROPOSED HANDHOLES SHALL BE INSTALLED WITH LIDS BOLTED TO THE HANDHOLE FRAME AND COVER FOR LOCKING PURPOSES. 2. ALL PROPOSED CONDUIT TERMINATIONS IN HANDHOLES SHALL HAVE BELL END CONNECTORS. 3. ALL PROPOSED HANDHOLE COVERS SHALL BE GROUNDED PER N.E.C. 4. SEE ONE -LINE DIAGRAM ON DWG NO. E03 FOR CONDUIT AND CONDUCTOR REQUIREMENTS. 5. EXISTING CONDUIT FOR PROPOSED POWER CONDUCTORS. 6. WHEN EXISTING HANDHOLES ARE TO BE REUSED, CONTRACTOR SHALL REMOVE EXISTING HANDHOLE LIDS, LID FRAMES, AND COVERS AND SHALL PROVIDE UTILITY VAULT CO. OR EQUAL LIDS, LID FRAMES, AND COVERS ON ALL EXISTING HANDHOLES. PROPOSED HANDHOLE LIDS SHALL BE INSTALLED WITH LIDS BOLTED TO THE HANDHOLE FRAME AND COVER FOR LOCKING PURPOSES. SEE DETAILS ON DWG NO. E08 FOR MORE INFORMATION. 7. CONTRACTOR SHALL ROUTE CONDUITS FROM PROPOSED NORTH TALBOT GENERATOR BUILDING SIGNAL CABINET TO THE EXISTING TELEMETRY PANEL LOCATED IN THE NORTH TALBOT BOOSTER PUMP STATION. 8. HANDHOLE LIDS SHALL BE PERMANENTLY MARKED FOR THEIR INTENDED USE, "SIGNAL" FOR ALL SIGNAL AND INSTRUMENTATION HANDHOLES AND "ELECTRICAL" FOR ALL POWER HANDHOLES. PERMANENT MARKING LETTERING SHALL BE 3" MINIMUM. USE RAISED WELD BEAD.I ELECTRICAL ROOM ENTRANCE. EXISTING NORTH TALBOT BOOSTER PUMP STATION SERVICE TRANSFORMER. l o S88'32'49"E TRANSFORMER TO BE REMOVED BY PUGET 58.47' SOUND ENERGY. SEE NOTE 2 ON DWG NO. E03 FOR MORE INFORMATION. PROPOSED NORTH TALBOT GENERATOR BUILDING SITE PLAN 1" = 20'-0" EXISTING CONCRETE. %W403239 10 REVISED TO CONFORM TO CONSTRUCTION RECORDS Pax '/ Oi 11 2007 / RH2 ENGINEERING INC. DATE EXISTING JUNCTION BOX TO BE REUSED THIS CONTRACT. APPROXIMATE LOCATION FROM WHICH PHOTO WAS TAKEN. NO. EXPIRES 3 19 20088, SIGNED.- 07128106 EXPIRES 7/15/2009 SIGNEk 07-128106 �Y wv v j � z cn J Z LLI LLI ai s Z LLI LLI cn c aW cn m0 CL M..-t 00 m Cr J CL a http j j www.-^'. om mcilbox®rh2.com 1.800.720.8052 BELLINGHAM OFFICE 360.676.0836 454 West Horton Rood 425.�5?.540G 12100 NE 195th Street, Suite 100 7ATCHEEOFFIC 300 Simon Street, Suite 5 PORT ORCHARD OFFICE 360.876.7960 600 Kitsop Street, Suite 101 SCALE: SHOWN 0 Z„ 2„ DRAWING IS NOT TO SCALE EXISTING NORTH TALBOT BOOSTER PUMP STATION IF gAR IS NOT 2" 1_oNc REVISED TO CONFORM TO CONSTRUCTION RECORDS REVISED PRIMARY UTILITY POLE LOCATION REVISED TRANSFORMER LOCATION REVISED PER ADDENDUM NO. 2 REVISION ?_0T: 20 we No. C08 ENG�NFER: DJB CMR MLM 11 /01 /07 REVIEWED: MM CMR MLM 04/18/07 DATE: NOV 9, 2007 SH F N0 NLA MLM 2/6/07 utiEwT REN RPC MLM 09/06/06 Joe No.: 105-079 733 BY REVIEW DATE FILENAME: GEN-D-CO8