HomeMy WebLinkAboutWTR2703239.158" TYP
3'-4"
I�
I
7'-4"
CHAIN -LINK GATE POST, TYP OF 8. POST
LOCATIONS SYMMETRIC ABOUT BLDG
CENTERLINE. SEE DWG C09 FOR DETAILS
2'-0" 13'-4"
12'-0"
4'-0"
1
,� � 1'-0" TYP
2 10 CABLE TROUGH 308
'�- 3'-4"
24'-0,"
I L
L
154.00' TYP
AT EDGES
19'-0"
ROLL UP DOOR LINTEL, 4 44
TYP OF 2 S08
32'-0"
2i-8"
PORTABLE GENERATOR 11RE
GUIDE.
u f u
6'-9" 4'-4-
CONTRACTOR- DESIGNED
REMOVABLE PLATFORM FOR
STATIONARY ENGINE GENERATOR.
SEE S06 FOR DETAILS
IIIIIIIIIIIIIIIIIIIIII Ill 01111111111111111111111
10'-2"
(2) #6 FULL HEIGHT OF WALL,
TV OF 12 LOCATIONS SHOWN,
EAST AND WEST WALLS.
12'-0" THRESHOLD
2'-8" TYP OF 4
30
S07
---- --- - 14'-8"
NOTE:
SPECIAL INSPECTION REQUIRED FOR
SPLIT FACE CMU CONSTRUCTION AT
THIS BUILDING.
30Q
SEE S07 FOR
GENERAL STRUCTURAL
NOTES
-8"
STATIONARY EG PAD
310
S08
EXTEND FOOTING FOR FENCE
POST EMBEDMENT, TYP. SEE
DETAIL THIS SHEET. 3
SO4
ENGINE GENERATOR FUEL
LINE. SEE DWG NO. CO3
FOR CONTINUATION.
12'-0" 2'-8"
12'-0„
1
SAFETY EQUIPMENT
2
SO4
I
V1
5'-4"
NOTE:
SPLIT FACED IS ONLY
ON EXTERIOR FACE.
OPENING RST, TYP 402
G
CONCRETE APRON OUTLINE
0
S07
21-0"
3'-4"
THRESHOLD S07
I
HEARING PROTECTION SIGN
i /111 1
SO4
ROOF OUTLINE
SPLIT FACE CMU WALL, TYP
40i
11'-4" S08
38'-0"
SPREAD FOOTING
05
S07
A
NOTE:
SEE DWG A01 FOR LOUVER AND
VENTILATION SCHEDULE.
LEGEND
SPREAD FOOTING
EG PAD
FINISHED FLOOR
SPLIT FACE CMU WALL
DOOR
r—
LOUVER
FAN
ROOF OUTLINE
FOUNDATION
FOOTING
STEM WALL
FLOOR SLAB
2" CLR
TYP
6"
A
O
5"
5"
STANDARD PLAN FOOTING SECTION A -A
FOOTING RST
FENCE POST DETAIL 3
Y4= 1'-0"
6" FLOOR PENETRATION FOR
FUEL TANK FILL PIPE. VERIFY 06
LOCATION WITH ENGINE S07
GENERATOR SUBMITTAL PRIOR
TO INSTALLATION.
CMU CORNER RST S08
W40,324N I T
REVISED TO CONFORM
TO CONSTRUCTION RECORDS
11/01Z2007
RH2 ENGINEERING INC. DATE
'"0 FENCE POST
CONCRETE APRON. WHERE NO
APRON EXTEND CONCRETE
ABOVE GRADE AND SLOPE TO
DRAIN.
12
,3) #5 X 6„ j 6"
�5 DOWELS ON EACH SIDE OF
'OST.
t � Ib/Yt
12" MIN $�arassa�9 1
1
O
EXPIRES 8/2 08
HEARING MOUNT WITH 4 SIGNED: 07/28/06
ANCHOR BOLTS
� KOR
8" MIN PROTECTION t "'$�fM�
REQUIRED MIN 1" HIGH
I ENGRAVED LETTERS ,
1 �y 296 , 5
O O �b $aalq-rzs 1
ICTAL
1/8- THICK BLACK LETTERS ON EXPIRES 5 29 09
SIGNED. 07f28/06
WHITE FACE ENGRAVED SIGN PLATE
HEARING PROTECTION SIGN
NOT TO SCALE
ba
ENTRY DOOR.
�N�o
FIRE EXTINGUISHER
ZZ FIRST AID KIT
HEADPHONE STYLE HEARING
PROTECTOR AND WALL HOOK
(2 PAIR REQUIRED)
5555 WALL MOUNTED EAR PLUG
DISPENSER WITH 100 PAIR
SAFETY EQUIPMENT 2
NOT TO SCALE
GROUND FLOOR OBLIQUE,
NOT TO SCALE
3 REVISED TO CONFORM TO CONSTRUCTION RECORDS
NO. REVISION
Z
a
oc
0
0
J
LL
Uj
J
0
■
ou
94
ENGINE=
PL 4F�s
SCIEty rG
RH2 ENGINEERING, INC.
http: //www.rh2.com
mailbox®rh2.com
1,800,720.8052
BELLINGHAM OFFICE
360.676.0836
454 West Horton Road
BOTHELL OFFICE
425.951.5400
12100 NE 195th Street, Suite 100
EAST WENATCHEE OFFIC
509.886.2900
i
300 Simon Street, Suite 5
r
FORT ORCHARD OFFICE
360.876.7960
600 Kitsop Street, Suite 101
SCALE: SHOWN
0 1" 2"
DRAWING IS NOT TO SCALE
IF BAR IS NOT 2" LONG
q-; 32
DWG NO.
ENGINEER: NC
SO4
REVIEWED: KLK
DATE: OCT 17, 2005
SHEET N°
15
CLIENT: REN
JMC
MLM
11 f 01 /2007
JOB Na.: 105.079
T331
BY
REVIEW
DATE
LENaME: GEN-D-SOI.DWG
A 3 '.1.t) • 3 Z31 1'5