HomeMy WebLinkAboutWTR2703239.23TRIM Y," THICK VERTICAL LEG AS REQD FOR GRATING THICKNESS )6" X 6" ANCHORS 0 1'-6" CENTERS p D to FRP GRATING, TYP F 1" BEARING BAR MINIMUM BEARING HORIZONTAL DIMENSION -1" GRATING SUPPORT NOT TO SCALE SEE GRATING SUPPORT DETAIL (4) #4 CONTINUOUS #4 X 0 16" O.C. SIM AT ENDS -" CHAMFER ALL EXPOSED EDGES 4" a 2'-0" a FRP GRATING FLUSH WITH CONCRETE SURFACE. GRATING TO BE FIBERGRATE 1 "x1 "x4" STANDARD MOLDED CHEMGRATE OR APPROVED EQUIVALENT. 1'-O" 6" J 6" / SLAB REINFORCEMENT CABLETROUGH 309 1" — 1'-0" p D e p a p p a 2" MIN. BEYOND EQUIPMENT BOLTS, TYP. r-" PJF ALL AROUND DOUBLE 2x8 PRESSURE TREATED HEADER, CONTINUOUS WITH )i"O J-BOLTS - SPACING VARIES (SEE ROOF BOND BEAM, TOP COURSE PLAN FOR SPACINGS) IN GROUTED VERTICAL CELLS, 1 BOLT LENGTH AS NECESSARY FOR 15" EMBEDMENT. TOP OF WALL SMOOTH FACE EXTERIOR AT TOP COURSE � ` BONGNBEAM INTERIOR FACE OF ALL SPLIT FACE CMU BLOCKS TO BE SMOOTH FACE #5 VERTICAL RST 0 32" O.C. MAX. TIE RST TO DOWELS IN FLOOR, FILL ALL REINFORCED CELLS WITH GROUT. DO NOT GROUT UNREINFORCED CELLS. 0' qLll BOND BEAM 0.00' 4 FLOOR EL • PER PLAN e. CONCRETE FLOOR #4012"EWT&B EMERGENCY GENERATOR EQUIPMENT PAD 310 1" - 0 ," CHAMFER ALL EXPOSED EDGES #4 x 6" CONCRETE ANCHORS 0 12" Q.C. p CONCRETE TIRE GUIDE 2" CLR 4" 0 SLAB RST n PORTABLE GENERATOR TIRE GUIDE, 1" = 0'-6" 8"x8"x16" COLORED SPLIT FACE CMU, PROVIDE WEATHERPROOF AND ANTI -GRAFFITI COATING ON EXTERIOR. COLOR TO BE SELECTED BY CITY. SPLIT FACE CMU WALL INSULATION. ALL NON -GROUTED EXTERIOR WALL AND INTERIOR FILTER — ROOM WALL SPLIT FACE CWU BLOCK TO BE V' ­*�\-1 INSULATED AS SPECIFIED. TO A R-11 VALUE OR PERLITE W/ BETTER. R-6 VALUE PROVIDED _ BOND BEAM WITH (2) #5 CONTINUOUS, LAP JOINTS 24" MINIMUM (TYPICAL) #5 DOWELS AT 32" O.C., TYPICAL, TO MATCH LOCATIONS OF VERTICALLY REINFORCED CELLS OF SPLIT FACE CMU WALL ABOVE. INSULATION BOARD, CONTINUOUS AS SPECIFIED ELSEWHERE. CONCRETE STEM WALL EXTERIOR SPLIT FACE CMU WALL 401 NOT TO SCALE (2) #5 MIN IN GROUTEL (1) #5 EA SIDE 'ENING, FULL HEIGHT, TYP. �- LINTEL BLOCK TYPICAL SPLIT FACE CMU OPENING e NOT TO SCALE #5 • 32" O.C, VERT. 54" • 8" 30" #5 CORNER BARS AT ALL BOND BEAM LOCATIONS AT WALL CORNERS AND INTERSECTIONS #5 CORNER BARS AT ALL BOND 54 BEAM LOCATIONS AT WALL CORNERS • SPLIT FACE CMU WALL SPLIT FACE CMU WALL INTERSECTION /CORNER n _ 1'—on ROOFING ROOF SHEATHING -� PLYWOOD ROOF DECK SIMPSON L70, TRUSS TO TOP PLATE 1" AIR GAP, MIN. ATTACH BLOCKING TO SILL PLATE WITH FRAMING ANCHORS PER PLAN I: FULL DEPTH VENTED EAVE BLOCKIN #5 VERT, TYR �i VENTILATION BAFFLE, INSTALL TO KEEP INSULATION AWAY FROM EAVE VENTS - R-30 PROVIDED R-38 KRAFT PAPER FACED BATT INSULATION ON TRUSS ALL CEILING SURFACES, INSTALL WITH KRAFT FACED „ USS I F INSULATION F N I I 1 x8 CEDAR / , l SIDE OFACING INTERIOR OF BUILDING. FASCIA OVER - SOFFIT NAILER WITH VENT PRESSURE TREATED FINISH CEILING WITH TWO LAYERS 2"x6" NAILER 1"x4" CEDAR TRIM, = OF %" GYPSUM WALLBOARD, 1"x2" CEDAR TRIM, J CONTINUOUS, TYP. FINISH SMOOTH AND PAINT WHITE. CONTINUOUS, TYP. ATTACH TRUSS TO SILL PLATE WITH SIMPSON H1 1"x4" FINISH GRADE HEMLOCK FRAMING ANCHOR TRIM, CONTINUOUS, TYP. (EXTERIOR WALL) SPLIT FACE CMU WALL/TRUSS CONNECTIONS 601 BOND BEAM GROUTED STANDARD BLOCK - LINTEL BLOCK (2) #5 EXTENDED 24" BEYOND OPENING IN GROUTED CELLS ROLL -UP DOOR TYPICAL ROLL UP 404 DOOR LINTEL 1" = 1'-0" V44 4M *13 w32 REVISED TO CONFORM TO CONSTRUCTION RECORDS I %� 4 11 01 2007 RH2 ENGINEERING INC. DATE H. 16727 Of. % ;0 EXPIRES d/2 08 SIGNED. 07128106 EXPIRES 5 29/09 SIGNED. 071128106 � IN ry RH2 ENGINEERING, INC. EXHAUST FAN http://www.rh2.com mailbox®rh2.com 1.800.720.8052 BELLINGHAM OFFICE SHEET METAL COLLAR 360.676,0836 CONNECTING DAMPER TO FAN (1 454 West Horton Road BOTHELL OFFICE MOTORIZED DAMPER 1 425.951,5400 a S12100 NE 195th Street, Suite 100 SPLIT FACE CMU WALL 2 SHEET METAL COLLAR ,AST WENATCHEE OFFICE 509.886.2900 300 Simon Street, Suite 5 PORT ORCHARD OFFICE NO. 360.876.7960 600 Kitsap Street, Suite 101 SCALE: SHOWN _ DIMENSION PER PLAN 0 1" 2" ACOUSTICAL LOUVER DRAWING IS NOT TO SCALE IF BAR IS NOT 2" LONG PLOT: 32 DWG NO. EXHAUST FAN DETAIL ENGINEER: JMC S08 701 REVIEWED: KLK NOT TO SCALE DATE: NOV 5, 2007 SHEET N0. REVISED TO CONFORM TO CONSTRUCTION RECORDS JMC MLM 11/01/07 CLIENT: REN REVISED PER BUILDING PERMIT RPC MLM 08/17/06 doe NO.: 105-079 33 REVISION BY REVIEW DATE EIENAME: GEN-D-S07 A;- w.'�23'IZ5