HomeMy WebLinkAboutWTR2703239.24- ONE -LINE DIAGRAM SYMBOLS PANELBOARDS, SWITCHES, AND EQUIPMENT LIGHTING FIXTURESIDEV►CES P&ID BUBBLE IDENTIFICATION CHART LADDER LOGIC SYMBOL LEGEND L. AS'A — --�"�---� -- RTM EE SSRVS ' a i A � XCID1DEVICES CIRCUIT BREAKER XXX YY - CB SIZE & NO. OF POLES ET - ELECTRONIC TRIP TM- THERMAL MAGNETIC BREAKER MCP — MOTOR CIRCUIT PROTECTOR SE - SERVICE ENTRANCE GF! - GROUND FAULT INTERRUPTER FUSE FUSED DISCONNECT SWITCH PLUG-IN CONNECTION RUN TIME METER MOTOR OPERATION COUNTER SSRVS - SOLID STATE REDUCED VOLTAGE STARTER VARIABLE FREQUENCY DRIVE MOTOR STARTER MOTOR STARitR 4N/ OPERATOR A - HAND -OFF -AUTO B - OPERATIONAL COUNTER SERVICE ENTRANCE, SWITCHGEAR, MOTOR CONTROL CENTER, OR PANELBOARD I � � SURFACE MOUNTED PANE`BOARD ! i , FLUSHED MOUNTED PANELBOARD NXX FIELD CONTROL STATION WITH NEMA REQUIREMENTS. - NEMA N3R - NEMA 3R N4 - NEMA 4 N4SS - NEMA 4 STAINLESS STEEL N4F - NEMA 4 FIBERGLASS N6 - NEMA 6 N12 -NEMA 12 GASKETED �- EQUIPMENT MOUNTING STAND HEATER HEATER, WATTAGE NOTED 15 kW EQUIPMENT CONNECTION FLUORESCENT FIXTURE l CEILING MOUNTED FIXTURE WALL / EMERGENCY LIGHT WITH SELF CONTAINED BATTERY SURFACE OR PENDANT MOUNTED FIXTUREN1 RECESSED FIXTURE MD MOTION DETECTOR IscPHOTO CONTROL CELL EXISTING FUNCTION INDICATOR LIGHT INDICATOR LIGHT A -AMBER G -GREEN - B -BLUE R RED C —CLEAR � LIMIT SWITCH C7 LIMIT SWITCH; NORMALLY OPEN LIMIT SWITCH LIMIT SWITCH, NORMALLY CLOSED TIME DELAY CONTACT TIME DELAY CONTACT, NORMALLY OPEN, .. - _ TIME TO CLOSE IN- TIME DELAY CONTACT TIME DELAY CONTACT, NORMALLY I N CLOSED, TIME TO OPEN TIME DELAY CONTACT - TIME DELAY CONTACT, NORMALLY OPEN, � __ - �TME 70 OPEN . TIME DELAY CONTACT RELAYS XYZ RELAY 123 TR - Timed relay CR - Control relay FLOAT SWITCH (� FLOAT SWITCH, NORMALLY OPEN � FLOAT FLOAT SIGH, NORMALLY CLOSED PUSHBUTTON PUSHBUTTON, NORMALLY CLOSED EE _ ` 4 PUSHBUTTONOPERATOR PUSHBUTTON, NORMALLY OPEN THERMOSTAT i '� THERMO SWITCH, NORMALLY OPEN THERMOSTAT aY yj9�j*��� $r 2780 � orasta � I� � JEXPIRES 3 1 s 2008 SIGNED: 07/28/06 0 INSTRUMENT IDENTIFICATION BUBBLE 0 � FIELD MOUNTED DEVICE OR INSTRUMENT FRONT PANEL MOUNTED INSTRUMENT OR DEVICE LOCAL ( PANEL) XS J. $ �� �� ,`$�`'��p qq. o / 40438 ISTS ICNAL EXPIRES 5/14 2008 SIGNED: 07j28jU6 BACK PANEL MOUNTED INSTRUMENT OR DEVICE (L OCAL PANEL) FRONT PANEL MOUNTED INSTRUMENT OR DEVICE (LAB ROOM PANEL) OPERATOR INTERFACE DISPLAY (LOCAL PANEL; I INTERFACE DISPLAY (LAB ROOM PANEL) I V 1 1 f 0 FIRE SYSTEM SYMBOLS INDICATE TYPE BY LETTER INSTRUMENT METER < HEAT DETECTOR S SMOKE DETECTOR ' � FIRE ALARM DISPATCH STROBE ALARM ® FIRE ALARM AUDIBLE/VISUAL ALARM V- - ---�_�- OAM AM - AMMETER VAR - VARMETER AH -AMPERE-HOUR VARH - VARHOUR METER PFM -POWER FACTOR WM -WATTMETER VM - VOLTMETER VA AMMETER WH - WATTHOUR METER C - RUN TIME METER D - RUN LIGHT E - FAIL LIGHT M SINGLE PHASE MOTOR. HORSEPOWER AS NOTED _ ! Fj FIRE ALARM MANUAL PULL STATION TIME DELAY CONTACT NORMALLY zP CLOSED, TIME TO CLOSE F ":-K THERMO SWITCH, NORMALLY CLOSED - FACILITY RACEWAY LEGEND - - - -- --- - 517-f PL, N Lff(YND ADDITIONAL SYMBOLS �-- F - EMERGENCY STOP KIRK KEY INTERLOCK POWER TRANSFORMER CONTROL POWER TRANSFORMER I TRANSFORMER CURRENT TRANSFORMER VOLTAGE TRANSFORMER �--� 1 pp THREE PHASE MOTOR. HORSEPOWER AS NOTED � HP SINGLE PHASE MOTOR. HORSEPOWER AS NOTED GEELECTRICAL PLUG AMPS DISCONNECT SWITCH ! ( AMPERAGE NOTED` ( El FUSED DISCONNECT SWITCH SEE DWG N0. G02 FOR PROPOSED SITE LEGEND � LII� �i1�� AI'l r ��� ! EXISTING CONDUIT AND CONDUCTORS 480 VOLT WIRING GROUND WIRING r �I Pull -DING Oil F/CI,Ltn' PLAN LEGEND I EXPOSED RACEWAY CONCEALED IN WALL OR CEILING CONCEALED IN OR BELOW FLOOR I RELAY CONTACT; NC .__ RELAY CONTACT, INSTANTANEOUS CHANGE RELAY CONTACT, NO PRESSURE SWITCH _ �, -- PRESSURE SWITCH, NORMALLY OPEN PRESSURE SWITCH PRESSURE SWITCH, NORMALLY CLOSED FLOWSWlTCH O FLOWSYIITCH, NORMALLY OPEN FLOWSWITCH I Q--`-? " `I� FLOWSWITCH, NORMALLY CLOSED --� 2 POLE SWITCH l � W y LL! w �W W 0 j S SOUND SYSTEM SPEAKER ii SOUND SYSTEM VOLUME CONTROL i g DOORBELL VALVE SYMBOLS _ PILOT VALVE SOLENOID II I VALVE i CD CONTACTOR CAPACITOR ENGINE GENERATOR GENERATOR CONNECTION RECEPTACLE F7 COMBINATION MOTOR STARTER AND DISCONNECT SWITCH i"iCHECK VALVE ' CONTROL VALVE ' � %h �� UNDERGROUND CONDUIT GROUND WIRING HOME RUN TO PANEL80ARD OR AS INDICATED CONDUIT RUN, BROKEN AND CONTINUED SAME SHEET OR AS NOTED � FLEXIBLE CONDUIT , ; _ 3 POLE SWITCH s W � J J C) c i BOX SYMBOLS RECEPTACLES AND JUNCTIONO S i CEILING JUNCTION BOX ! J WALL JUNCTION BOX S N TB SOLID NEUTRAL TERMINAL BLOCK TRANSIENT VOLTAGE SURGE SUPPRESSOR I ❑J FLOOR JUNCTION BOX DUPLEX WALL RECEPTACLE , 120V WP = WEATHERPROOF G = GROUNDED IG - ISOLATED GROUND GF = GROUND FAULT INTERRUPTER DOUBLE DUPLEX !IT CONDUIT RUN. HATCH MARKS INDICATE NUMBER OF CONDUCTORS TIN INDICATING CONDUIT SIZE CALLOU .. D , n NUMBER AND SIZE OF WIRE. i i� CRC, 2-#12 i CALL OUT INDICATING CONDUIT PER SCHEDULE I 100 " ONDUIT BENT UP OR TOWARD __ - -�-- - _-. -_ -Uj ABBREVIATIONS - 1P 1 POLE 1PH - SINGLE PHASE NEMA - NATIONAL ELECTRICAL MANUFACTURING ASSOCIATION 2P - 2 POLE N.L. - NIGHT LIGHT 2PH - TWO PHASE mA - MILIAMP 3P - 3 POLE MCC - MOTOR CONTROL CENTER i 3PH - THREE PHASE MCM - ONE THOUSAND CIRCULAR MILS F � ••�+: .0011 ! PID FORMAT SUPERSCRIPT X=MEASUR€D OR INITIATING VARIABLE XYZ Y=READOUT OR FUNCTION Z=MODIFIER ABC ABC -LOOP NUMBER INSTRUMENT BUBBLE TVSS TRANSIENT VOLTAGE SURGE ° 01 SUPPRESSOR (ALTERNATIVE) ❑G GROUND BLOCK NEUTRAL BLOCK TB POWER POWER METER DETER TB GENERATOR BLOCK HEATER - 1 - _ PROPOSED EQUIPMENT ENCLOSURE EXISTING EQUIPMENT ENCLOSURE ® A0SPECIAL TV Q SINGLE RECEPTACLE, 120V SINGLE RECEPTACLE, 208V DUPLEX FLOOR RECEPTACLE, 120V PURPOSE WALL RECEPTACLE, A OTED RATING S Iv CLOCK T €LEVISION nun TEI E: , °ONE TELEPHONE/DATA WITH CABLE TELEPHONE/DATA WITHOUT CABLE CONDUIT BENT DOWN OR AWAY 3 CAPPED CONDUIT AF AMP FRAME P _ POWER AH AMP HOUR PB PANNIC BUTTON AL - ALUMINUM PC - POWER & CONTROL ASTM - AMERICAN SOCIETY FOR TESTING AND MATERIALS PF - POWER FACTOR _ _ AT AMP TRIP PNL PANEL ATS - AUTOMATIC TRANSFER SWITCH PSE - PUGET SOUND ENERGYPFA BPS - BOOSTER PUMP STATION PVC - POLYVINYL CHLORIDE CONDUIT j C - CONTROL PWR - POWER - CONTROL & INSTRUMENTATION RECP - RECEPTACLE CKT - CIRCUIT SPDT - SINGLE POLE, DOUBLE THROW CO - CONDUIT ONLY SPST - SINGLE POLE, SINGLE THROW CR - CONTROL RELAY SSRVS - SOLID STATE REDUCED VOLTAGE STARTER CTRL - CONTROL SUSE - SUITABLE FOR USE AS SERVICE ENTRANCE CU -COPPER TE -TERMINAL BLOCK DPST - DOUBLE POLE, SINGLE THROW TEMP - TEMPERATURE EG - ENGINE GENERATOR TVSS - TRANSIENT VOLTAGE SURGE SUPPRSSOR GFI - GROUND FAULT INTERRUPT TYP. - TYPICAL GRC - GALVANIZED RIDGID CONDUIT U,L. - UNDERWRITERS LABORATORIES l HOA - HAND OFF -AUTO VAC -VOLTS AC HP - HORSE POWER VCP - VOLTS CONTROL POWER KAIC - THOUSAND AMP INTERRUPTING CAPACITY VDC - VOLTS DC KVA - KILOVOLT AMP VFD - VARIABLE FREQUENCY DRIVE KVAR - KILOVOLT AMPS REACTIVE W - WATT KW -- KILOWATT WP --- WEATHER-PROOF NEC - NATIONAL ELECTRIC CODE WSDOT - WASHINGTON STATE DEPARTMENT OF TRANSPORTATION GENERAL NOTES 1. THIS iS A STANDARD LEGEND. NOT ALL OF THE INFORMATION SHOWN ON THIS PAGE WILL3 IN THIS SET OF PLANS. 2. THESE DRAWINGS ARE DIAGRAMMATIC ONLY. EXACT LOCATIONS OF ELECTRICAL EQUIPMENT f SHALL BE DETERMINED IN THE FIELD BY THE ENGINEER. THE INSTALLATION OF ALL EQUIPMENT 2 4 SHOWN ON THESE DRAWINGS OR DESCRIBED IN THE SPECIFICATIONS SHALL CONFORM TO THE REQUIREMENTS SET FORTH IN THE LATEST EDITIONS OF ALL APPLICABLE CODES AND UTILITY 1 COMPANY STANDARDS. CONTACT THE UTILITY COMPANY REPRESENTATIVES AND VERIFY THEIR I REVISED TO CONFORM R ! TO CONSTRUCTION RECORDS i w 3. NOTIFY THE ENGINEER IMMEDIATELY IF CONFLICTS IN EQUIPMENT LOCATIONS ARE DISCOVERED r,�, OR IF PROBLEMS ARISE DUE TO FIELD CONDITIONS. LACK OF INFORMATION OR ANY OTHER I 4 fL�" `� 11/01/2007 REASON. NO PAYMENT WILL BE MADE FOR CHANGES WHICH HAVE NOT BEEN FAVORABLY RH2 ENGINEERING INC. DATE REVIEWED BY THE ENGINEER. , REVISED TO CONFORM TO CONSTRUCTION RECORDS CMR MLM 11/01/07 ISA STANDARDS FOR P&ID 1st LETTER (MEASURED 12nd LETTER (READOUT 13rd LETTER OR INITIATING VARIABLE) I OR FUNCTION) I (MODIFIER) iw ZA E E RH2 ENGINEEF29NC, INC : http://www.rh2.com a // ma ilbox0rh2.com 1.800.720.8052 k OFFICE 56.;;5 � 454 West Horton Road , OTHELL OFFICE 425.951.5400 12100 NE 195th Street, Suite 100 EAST WENATCHEE OFFIC 509,886.2900 300 Simon Street, Suite 5 BARD OFFICE 36 a60 6• � St,ee}, Suite to ELECTRICAL & SIGNAL PLAN DEVICES A g , C D E F G H J K L M N 0 P Q R S T U V W X Y - l Z ANALYSIS I ALARM I BURNER I CONTROLCJ COMMUNICATION ! I CLOSED DENSITY VOLTAGE I I - - - - - - - —1— - - - - - - -- - - - - - - FLOW I I FAIL GAS i I GREEN BULB HAND I MANUAL I HIGH CURRENT I INDICATE I POWER I I ---------------'"—`t--------- TIME I CONTROL STATION I LEVEL LIGHT LOW I ( MIDDLE MOTION I I USERS CHOICE USERS CHOICE I - - I OPEN _. - - -- - - -I- - - - - - - - -- - - - _I PRESSURE I I QUANTITY I TOTALIZE I RADIATION 1 RECORD 1 RED BULB SPEED I SWITCH I SOLENOID TEMPERATURE I TRANSMITTER I ----------------_--APPEAR MULTI VARIABLE I VALVE FUNCTION - - - VISCOSITY I I WEIGHT I j UNCLASSIFIED USERS CHOICE I RELAY I - - - - - - - —I— - - - - - - - - - - - - - -- POSITION l I I I I I $ 1 I I i I I SV SOLENOID VALVE COIL OLE, LEVEL ELEMENT MV MOTORIZED VALVE COIL HE HEATING ELEMENT FS FLOAT SWITCH PS PRESSURE SWITCH LS LIMIT SWITCH TI TEMPERATURE INDICATION /'1 � r � PB PANIC BUTTON TS) TEMPERATURE SWITCH �./ T THERMOSTAT SWITCH 1 ZS INTRUSION JWI inn SWITCH � ` FE FLOW ELEMENT I OAE ANALYSIS ELEMENT I � GROUNDING SYSTEM SYMBOLS SWITCH OUTLETS 1 GROUND - METAL PIPE GROUND CONNECTION POINT, EXOTHERMIC WELD. OR APPROVED EQUAL. GROUND ROD SIZED PER N.E.C. USE EXOTHERMIC WELD CONNECTION AT THE GROUND ROD. PIGTAIL BARE COPPER LENGTH AS , 3 REQUIRED, $ MINIMUM. �- CONNECTION POINT, MECHANICAL, COMPRESSION TYPE. S STANDARD SWITCH, 120VAC, 20 AMP l () 3-WAY SWITCH, 120VAC, 20 AMP SWAY 3-POSITION SWITCH, 120VAC, 20 AMP, HOA HOA LABEL SWITCH POSITION HAND -OFF -MOTION OR PHOTO _ DEE SINGLE -POLE P PILOT -LIGHTED � DOUBLE -POLE S KEY -OPERATED 2 K S THREE WAY S LOW VOLTAGE 3 LV S FOUR WAY S MASTER 4 M S DIMMER 0 PUSHBUTTON SCALE: SHOWN 6M�"CADWELD v: 0 1 T 2 DRAWING IS NOT � O SCALE IF BAR IS NOT 2" LONG P; 7REQUIREMENTS. ``' 1 Na. 1 EO i ENGINEER:,�,I{j REVE+ o:KLK DA =. NOV 2, 2007'EET "o. 24 733 'CLIENT:REN GROUNDING SYSTEM SYMBOLS Joe No.: 105-079 I I I I NO, REVISION BY REVIEW DATE SEE DWG NO. G02, 9LENAME: GEN-D-EO1 mg A)J 1�).'1' >