WTR2703239.25
OUTSIDE PROPOSED SERVICE PROPOSED MT. OLIVET GENERATOR DISCONNECT. /� BUILDING SWITCHBOARD. 800A, 480V, 30, 3W with Neutral Lug, 42 KAIC Withstand I -- l 500 kVA ( ® TB EXISTING P.S.E. PRIMARY 480/277 I I I 20A 2P 30A 3P 20A 2P TM TM SERVICE WIRING. 800A L POWER: J I I"` 6 ATM I METER IrNJ I TB i 100 q l EXISTING CITY OWNED MT. OLIVET BOOSTER PUMP STATION PAD —MOUNT I SERVICE TRANSFORMER. SEE NOTE 5. I i I 800A 3P I_ I TM l i B I F- 7-- 101 - I OA - BT__._ 0 I 800A j 1 I G N OA _ OB� 3 POLE AUTOMATIC ( I I TRANSFER SWITCH. SEE SPECIFICATIONS. - - - - - - -� o D 102 iO3 102 Cr I 2 101 ��'J� 30A�3P " #2/0 BARE COPPER GROUND I 12i ELECTRODE CONDUCTOR TO ! GROUND ELECTRODES PER N.E.C. I 15 kWI HEATER GROUND CONNECTION POINT (TYPICAL). SEE GROUNDING DETAILS ON DWG NO. E08 #2/0 BARE -- - ---`` FOR MORE INFORMATION. COPPER I PROPOSED EG CONNECTION CONDUCTOR. CABLES WITH RECEPTACLE I CONNECTORS. SEE SPECIFICATIONS. 3/4" x 8' LONG COPPER GROUND ROD 4 ° - - I 40A 2P I % TM PER RFI-024, THE CONDUIT IS STUBBED OUT ON THE OUTSIDE EDGE OF THE GENERATOR CONCRETE PAD (TYPICAL). INSTALL PER N.E.C. SEE A B C ! 7 EG SET MOUNTED 40 AMP, 480 GROUNDING DETAILS ON DWG NO. E08 r I L BUILDING FOUNDATION. l I ( ( VOLT, 2 POLE BREAKER. SEE FOR MORE INFORMATION. I I G N �A �B �C r- r—� ENGINE GENERATOR SPECIFICATTOP I REBAR (TYPICAL). _ 1 l G 7 N, FOR MORE INFORMATION. / CONNECTION TO REBAR. Tl 4 I L SEE GROUNDING DEAILS E I -- �,-------.___- -.._- ---.. ON DWG NO. E08. I 40AMP G N I 2P 480/30 BUILDING LOAD CALCULATIONS Mt. Olivet Booster Pump Station 644 A x 1.00 = 644 Building Heating Load 22.5 A x 1.25 = 28.2 amps Stationary EG Block Heater 14 A x 1.00 = 14 Portable EG Block Heater 14 A x 1.00 = 14 Miscellaneous Load 18 A x 1.25 = 22.5 amps TOTAL 722.7 amps 900AMP , I 1 107 � 480 j30 PROPOSED 500 kW PORTABLE EMERGENCY GENERATOR SET. I 600KW I I SEE SPECIFICATIONS FOR MORE I INFORMATION. ■uh�e�r I � l ELECTRICAL EQUIPMENT LEGEND DESCRIPTION MANUFACTURER PART NO. SERVICE ENTRANCE DISCONNECT SWITCH - NEMA 12, 800 AMP, 600 VOLT RATED, HEAVY DUTY, SERVICE SIEMENS EISLMD63B800 OR ENTRANCE RATED CIRCUIT BREAKER SWITCH WITH NEUTRAL INCLUDED. MOUNT TOP OF ENCLOSURE 6'-0" EQUAL FROM FINISHED GRADE. © EMERGENCY GENERATOR RECEPTACLE PANEL TYPICAL OF TWO IN PARALLEL. COMPLETED ASSEMBLY SHALL GROUSE -HINDS E0400-1662 HAVE A MINIMUM CAPACITY OF 800 AMPS. RECEPTACLES SHALL BE MALE. C SURGE PROTECTIVE DEVICE WITH INTERNAL SURGE RATED FUSES. CONDUIT AND WIRING PER MANUFACTURER'S INNOVATIVE TECHNOLOGIES VG160-3Y201-SD 3 RECOMMENDATIONS. D O 20 AMP, 2-POLE, 3-WIRE, 480 VOLT RATED RECEPTACLE MOUNTED IN A TWO GANG BOX. SEE DWG NO. E04 LEVITON 2340 OR EQUAL FOR MORE INFORMATION. NEMA 4 STAINLESS STEEL ENCLOSURE WITH PARALLEL CROUSE-HINDS E0400-1687 POSI-LOK RECEPTACLES. SKYLINE ELECTRIC 59344 ® RECEPTACLES SHALL BE FEMALE. ENCLOSURE SHALL BE MOUNTED CURBSIDE. MANUFACTURING AUTOMATIC TRANSFER SWITCH - 70 AMP, 600 VOLT RATED, SINGLE PHASE, 2 POLE TRANSFER SWITCH. ASCO 300 SERIES OR MOUNT TOP OF ENCLOSURE 6'-0" ABOVE FINISHED GRADE. EQUAL_ O DISTRIBUTION TRANSFORMER - 10 kVA, 480/240-120, 600 VOLT RATED, SINGLE PHASE TRANSFORMER. SIEMENS 1FlRO10 OR EQUAL O LIGHTING PANEL - 125 AMP, 600 VOLT RATED, SINGLE PHASE, 3 WIRE WITH 60 AMP MAIN BREAKER. MOUNT SIEMENS P1A18BL100CTS OR I TOP OF ENCLOSURE 6'-0" FROM FINISHED GRADE. EQUAL K O TRANSFORMER DISCONNECT - 40 AMP, 600 VOLT RATED, 2 POLE DISCONNECT. MOUNT TOP OF ENCLOSURE SIEMENS HF262 OR EQUAL 6'-0" FROM FINISHED GRADE. ELECTRICAL NOTES 8 N G 10 kVA 480V-240/120V 106 CONTRACTOR SHALL USE EXISTING CONDUIT TO PULL PROPOSED CONDUCTORS FROM THE PROPOSED --�0 ELECTRICAL VAULT TO THE EXISTING MT. OLIVET MAIN DISCONNECT. PROPOSED 480 VOLT, 600 kW STATIONARY EMERGENCY GENERATOR SET. SEE SPECIFICATIONS FOR MORE INFORMATION. 277/480 V, 3�, 4W, 1OOOA 80OA/3P EXISTING SYSTEM GROUND. PROPOSED ELECTRICAL VAULT. CONTRACTOR SHALL INTERCEPT EXISTING CONDUIT FROM THE MT. OLIVET SERVICE TRANSFORMER TO THE MT. OLIVET BOOSTER PUMP STATION MAIN DISCONNECT IN ORDER TO SUPPLY POWER TO THE EXISTING BOOSTER PUMP STATION FROM THE PROPOSED MT. OLIVET GENERATOR BUILDING. SEE DWG NO. CO3 FOR MORE INFORMATION. BOND THE PAD -MOUNTED TRANSFORMER NEUTRAL CONNECTION (HO) TO GROUND PER RFI-059. PARKING 5(lA STAND XII`� i H LIGHTING I� ARRESTOR I SEE DWG NO. CO3, C04, C05 AND C06 FOR CONDUIT ROUTING. EXISTING AND PROPOSED RACEWAYS TO BE USED FOR NT OF PROPOSED HIGH MT. OLIVET GENERATOR BUILDING INSTALLIu1EVOLTAGE CONDUCTORS. ONE -LINE DIAGRAM 1! DO NOT BOND GROUND AND NEUTRAL AT THIS LOCATION. WIRING TO 480 VOLT, 10.4 AMP, 1� ENGINE GENERATOR MOUNTED BLOCK HEATER. 3� ENGINE GENERATOR BLOCK HEATER CABLE. CONTRACTOR SHALL PROVIDE A 100 FOOT LENGTH 3 WIRE, 20 AMP, 600 VOLT RATED SO CORD WITH 20 AMP, 3-WIRE, 480 VOLT i RATED RECEPTACLE PLUGS ON EACH END FOR SUPPLYING POWER TO THE PORTABLE ENGINE GENERATOR BLOCK HEATER. I/ POWER AND TELEMETRY ENTRANCE ENCLOSURE. SEE SPECIFICATIONS FOR MORE INFORMATION, UPON SUBSTANTIAL COMPLETION OF THE ELECTRICAL SYSTEM AT THE MT. OLIVET GENERATOR BUILDING, THE CONTRACTOR SHALL COORDINATE WITH THE CITY OF RENTON TO REMOVE POWER TO THE EXISTING PAD -MOUNT SERVICE TRANSFORMER CURRENTLY SERVING THE MT. OLIVET BOOSTER PUMP STATION- CONTRACTOR SHALL INTERCEPT THE EXISTING SECONDARY CONDUITS IN ORDER TO SET A PROPOSED ELECTRICAL VAULT. CONTRACTOR SHALL PROVIDE AND INSTALL PROPOSED CONDUIT FROM THE VAULT TO THE PROPOSED GENERATOR BUILDING AND SHALL PROVIDE AND INSTALL PROPOSED CONDUCTORS FROM THE EXISTING TRANSFORMER TO THE PROPOSED MT. OLIVET GENERATOR BUILDING, THE CONTRACTOR SHALL SCHEDULE THIS WORK WITH THE CITY 3 BUSINESS DAYS PRIOR TO BEGINNING THIS WORK, A PORTABLE GENERATOR WILL BE PROVIDED AND MAINTAINED AT THE MT. OLIVET BOOSTER PUMP STATION BY THE CITY DURING THE POWER OUTAGE. CONTRACTOR SHALL BE ALLOWED 3 BUSINESS DAYS TO COMPLETE THE CONDUIT AND CONDUCTOR ROUTING FOR SUPPLY POWER TO THE GENERATOR BUILDING AS WELL AS THE FEEDER FROM THE GENERATOR BUILDING TO THE EXISTING BOOSTER PUMP STATION. 6` CONTRACTOR SHALL INSTALL THREE (3) PROPOSED SMU-20 TYPE FUSES FOR USE IN SMD-20 MOUNTINGS IN COMPARTMENT THREE WHERE HIGH VOLTAGE CONDUCTORS FROM ' THE MT. OLIVET GENERATOR BUILDING WILL BE TERMINATED. E:�:�11'/-tMUND GENERATOR TO BUILDING"ROUND SYSTEM. SEE DWG N0.108 FOR GROUND CONNECTION DETAILS. FUSE'S NOT REQUIRED PER E:::� CONTRACTOR SHALL REMOVE EXISTING GROUND TO NEUTRAL BONDING JUMPER. RFI-038 AND RFI-038R1. 9. ALL BREAKERS SHALL BE 100% RATED. PROPOSED PAD-MOUN r-D OIL FILLED, 750 KVA STEP-UP TRANSFORMER 480 VOLT Y-12,470/7200 VOLT Y. NO SCALE PER RFI-011, 'USE CONDUIT FOR ALL CIRCUITS h. REVISED TO CONFORM TO CONSTRUCTION RECORDS 11 / 01 /2007 RH2 ENGINEERING INC. DATE CONDUCTOR/CONDUIT SCHEDULE 100 (3) 3" CONDUITS. EACH CONDUIT SHALL CONTAIN (3)-#300 MCM AND (1)-#300 MCM NEUTRAL. INSTALL CONDUIT AND CONDUCTORS PER NEC. 101 (3) 3" CONDUITS. EACH CONDUIT SHALL CONTAIN (3)-#300 MCM, (1)-2/0 NEUTRAL AND (1)-#2/0 GROUND. INSTALL CONDUIT AND CONDUCTORS PER NEC. 102 (1) 1/2" CONDUIT. CONDUIT SHALL CONTAIN (2)-#12 AND (1)-#12 GROUND. 103 (1) 3/4" CONDUIT. CONDUIT SHALL CONTAIN (2)-#10 AND (1)-#10 GROUND. 104 (1) 1/2" CONDUIT. CONDUIT SHALL CONTAIN (2)-#12 AND (1)-#12 GROUND. i(3) 3" CONDUITS. EACH CONDUIT SHALL CONTAIN (3)- MCM, (1)- NEUTRAL AND (1)-#1/0 GROUND. INSTALL CONDUIT AND CONDUCTORS PER NEC. 106 INSTALL (3)- MCM, (1)- #4/0 NEUTRAL AND (1 )-#1 j0 GROUND. s 107 lNSTALLC�ONDUIT ANDH OND°CONDCTORS PERUIT SHALLCNEGONTAIN (3)-#350 MCM AND (1)-2/0 GROUND. 108 (1) 3" CONDUIT. CONDUIT SHALL CONTAIN (3)-#2 15 kV SHIELDED CABLES. 109 (1) 3/4" CONDUIT, CONDUIT SHALL CONTAIN (2)-#8 AND (1)-#8 GROUND. 110 (1) 1" CONDUIT. CONDUIT SHALL CONTAIN (2)-#6 AND (1)-#6 GROUND. t EXISTING MT. OLIVET MCC. 30OA/3P 20OA j'3P 1 OA/3P 3OA/3P 2OA/2P 40OA/3P 1EXPIRES 3 19 2008 SIGNED. 07128106 SSRVS SSRVS SSRVS 150 HP 100 HP 480V - 24a/12av HEATER LIGHTING 3/4 HP PANEL 200 HP 15 kW MT. OLIVET BOOSTER PUMP STATION NO SCALE EXISTING S&C PMH MODEL PAD MOUNT, 3 POLE, PRIMARY ATS. SEE DWG NO. C06 FOR LOCATION. EXISTING PAD -MOUNT TRANSFORMER (12.47-480/277, 750 kVA). EXISTING SWITCHBOARD. XX MW Boo, TB POW IIAM SSRVS 1B K 200 HP SSRVS 200 HP PRIMARY JUNCTION BOX. M EXISTING UTILITY PRIMARY PAD -MOUNT PRIMARY SWITCH EXISTING UTILITY PRIMAf METER CABINET, EXISTING PAD -MOUNT TRANSFORMER (12.47-208/120, 750 kVA)= TO EXISTING LIBERTY PARK POOL BUILDING. EXISTING WELLS 1, 2 & 3 MCC. SSRVS 200 HP 2 HP 2 HP WELLS 1, 2 AND 3 REVISED TO CONFORM TO CONSTRUCTION RECORDS ONE -LINE DIAGRAM REVISED PER ENGINEER N0. REVISION TO EXISTING UTILITY POLE, EXPIRES 5/14/2008 SIGNED: 07128,106 C� Y (� A `' { .� ;N � O J W CPU O I- W 4�or O co ' W U) Cl) Ca Q tV - (� r 0 Q i %� 0 ^ V z -400 Z O .�,4 http. ; www.•, om mailbox®rh2.com 1.800.720.8052 13ELLINGHAM OFFICE 360.676,0836 454 West Horton Road BOTHELL OFFICE 425.951.5400 12100 NE 195th Street, Suite 100 AST WENATCHEE OFFICE 509.886.2900 300 Simon Street, Suite 5 PORT ORCHARD OFFICE 360.876.7960 600 Kitsap Street, Suite 101 SCALE: SHOWN 6� I 0 1" 2" DRAWING IS NOT TO SCALE IF BAR IS NOT 2" LONG -. 1 DWG NO. 2 HP ENGINEER: DJB E02 REVIEWED: MM DATE. NOV 9, 2007 SHEET No. CMR MLM 11/01/07 - EN-: REN 25 733 DJB MM 11 /28/06 joe NO.: 105-079 BY REVIEW DATE FILENAME GEN-D-E02 Aar W-$23125