Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WTR2703239.27
ENTRANCE DOORWAY. BUILDING EXHAUST WALL FAN, KEYED SWITCH BOX. 120 VAC, SINGLE PHASE. 9'-8" 9'-Q" HOA LIGHT SWITCH. SEE S ® A 1 200 LIGHTING CIRCUIT LOGIC DETAIL ON DWG NO. E08 — - FOR MORE INFORMATION. O I ZS M PB ,F . �.15AI DA I FI LA2 rl $ 220 M 220 MD 200 220 TO VENTILATION PANEL WALL MOUNTED 2 TO SIGNAL CABINET. GANG BOX. 208 jAl I TO SIGNAL CABINET. 11 TO LIGHTING PANEL. 200 TO SIGNAL CABINET. I f 200 f Al � 200 12'-4" MOTORIZED GENERATOR INTAKE LOUVER, 120 VAC, i SINGLE PHASE. MOTORIZED OVERHEAD DOOR, 120 VAC, SINGLE PHASE. lAl f I f M �. f 200 ' r S I 200 �z1 5A 220 f TO VENTILATION PANEL FOR POWER TO MOTOR ACTUATED LOUVER. f - - oA 200 TO LIGHTING PANEL (CKT, #1) FOR POWER 10'-0" M 220 TO OVERHEAD DOOR. O 11 L !TO VENTILATION PANEL. ,A1 OVERHEAD DOOR (TYP. OF 2). 107 6 200 WALL MOUNTED BATTERY CHARGER. MOUNT TOP OF ENCLOSURE 5-0" FROM FINISHED FLOOR. .. j ,. 9'-0" '20A GFI TO SWITCHBOARD. 1 200 200 TO LIGHTING PANEL (GFI CKT #1) 103 o- 200 4 TO LIGHTING PANEL f CONDUIT INSTALLED SURFACE TED TO CEILING PER T58 PROPOSED 600 kW STATIONARY ENGINE GENERATOR. SEE SPECIFICATIONS FOR 1 MORE INFORMATION. I 4 200 I 221 226 221 5 PROPOSED 500 kW PORTABLE ENGINE TO REMOTE FILL STATION. GENERATOR. SEE SPECIFICATIONS FOR SEE DWG NO. CO3 FOR Q MORE INFORMATION. F CONTINUATION. - TO LIGHTING PANEL. ZS B 221 3 ZS _.�- 109 TO SIGNAL CABINET. 101 200 221 w 220 1 A2 SWITCHBOARD ATS ATS Z! � 1017 200 REBAR (TYPICAL). I I I I i MOTORIZED GENERATOR EXHAUST LOUVER, 120 VAC; SINGLE PHASE. TO VENTILATION PANEL 102 © FOR POWER TO MOTOR ACTUATED LOUVER. 7 TO LIGHTING PANEL - ^^ KT. #2) FOR POWER TO OVERHEAD DOOR. 10'-O" CABLE TROUGH. TO SIGNAL CABINET 3 4 200 TO VENTILATION CONTROL PANEL. 221 I -_ ' S 12 F5 240 P 8 22Q - GFI ® 15A TI ;# TS M A I: 200 MAIN SERVICE 1 110 240 200 zi i'-0" DISCONNECT. 221 228 208 MOTORIZED BUILDING INTAKE 100 LOUVER, 120 VAC, SINGLE PHASE. PROPOSED LIGHTING PANEL. 2 g 1 8 � - GROUND ROD PER N.E.C. (TYPICAL). USE PROPOSED VENTILATION PANEL. MOUNT 0 LOUVER SHIFTED TO THE EXOTHERMIC WELL} CONNECTION AT EACH GROUND TOP OF ENCLOSURE 6'-0" FROM FINISHED J " SOUTH PER RFI-025 ROD. LOCATE GROUND RODS 2' MINIMUM FROM GRADE. SEE CONTROL LOGIC ON DWG NO. TO 2 SPARE CONDUITS BUILDING FOUNDATION. SEE DWG NO E08 FOR E06 FOR MORE INFORMATION. TO RESEVQIR LADDER 1 MORE INFORMATION. SIGNAL CABINET. MOUNT TOP OF ENCLOSURE 6'-0" FROM FINISHED RH 2 GRADE. SEE SPECIFICATIONS. 17 MT. OLIVET ELECTRICAL PLAN �' 137M 1" - 2'-0" 200 220 11 TO VENTILATION PANEL. 221 CONDUIT AND CONDUCTORS TO THE PROPOSED ELECTRICAL VAULT FOR POWER TO THE EXISTING MT. OLIVET BOOSTER PUMP STATION. SEE DWG NO. CO3 FOR CONTINUATION. BUILDING HEATER. M ZS X ZS i 4'-0" - NO t: ALL CONDUIT SHALL BE SURFACE MOUNTED WITH THE EXCEPTION OF LIGHTING AND RECEPTACLE CIRCUITS WHICH SHALL BE CONCEALED IN WALLS AND THE CEILING. , REVISED TO CONFORM TO CONSTRUCTION RECORDS )411 01 2007 RH2 ENGINEERING INC. DATE l/ CENTERLINE OF CONDUITS AND CONDUCTORS FROM THE SIGNAL CABINET TO THE EXISTING MT. OLIVET l/ BOOSTER PUMP STATION TELEMETRY PANEL. CONTRACTOR SHALL RUN AN ADDITIONAL 6 SPARE WIRES. - EG SET RUN (BOTH EG'S) - EG SET FUEL LEAK (BOTH EG'S) - INTRUSION ALARMS - EG SET FAIL (BOTH EG'S) - INTRUSION DISABLE - PANIC ALARM - EG SET TROUBLE (BOTH EG'S) - ATS FAIL ALARM (BOTH ATS'S) -SMOKE ALARM - EG SET LOW FUEL (BOTH EG'S) - BUILDING TEMP. (4-20 mA) - VENTILATION CALL - OVERHEAD DOOR POSITION INDICATION (2 DOORS) - 12VDC POWER FOR SMOKE DETECTOR OVERHEAD DOORS SHALL BE EQUIPPED WITH LIMIT SWITCHES TO INDICATE OPEN AND FULLY OPEN STATUS, SEE DETAIL ON DWG NO. E08 FOR MORE INFORMATION. 4 TO STATIONARY EG SET MOUNTED BATTERY. 5 TO SIGNAL CABINET FOR REMOTE INDICATION AND CONTROL OF THE FOLLOWING: - EG SET RUN - EG SET FUEL LEAK - EG SET FAIL - START SIGNAL (FROM ATS TO EG) - EG SET TROUBLE- EG SET LOW FUEL - VENTILATION CALL (FROM EG TO VENTILATION PANEL VIA THE SIGNAL CABINET. CONDUIT AND CONDUCTORS TO THE PROPOSED 750 kVA STEP UP TRANSFORMER. SEE DWG NO. CO3 FOR 22Q CONTINUATION. TO SWITCHBOARD FOR POWER TO EG MOUNTED BLOCK HEATER. L/ CONDUIT AND CONDUCTORS TO THE EXISTING CITY OWNED PAD -MOUNT SERVICE TRANSFORMER. CONDUIT AND CONDUCTORS FOR ATS START AND FAIL SIGNALS. ATS START AND FAIL SIGNALS FROM WELLS 1, 2 & 3 TRANSFER SWITCH. SEE DWG NO.'S CO3, C04, C05 AND C06 FOR CONTINUATION. 11 PROVIDE AUTOMATIC PUSHBUTTON OVERHEAD DOOR OPERATORS FOR EACH OVERHEAD DOOR. INSTALL AT 4' FROM THE FINISHED FLOOR. LOCATE DOOR OPERATORS IN WALL SPACE BETWEEN OVERHEAD DOORS. SEE TYPICAL OVERHEAD DOOR MOTOR ACTUATOR CONTROL LOGIC DETAIL ON DWG NO, E06 FOR MORE INFORMATION. �2 PORTABLE BATTERY CHARGER CABLE. ROUTE THROUGH CABLE TROUGH. h 3 PORTABLE GENERATOR SIGNAL CABLE. ROUTE CABLE THROUGH CABLE TROUGH TO SIGNAL CABINET FOR REMOTE INDICATION AND CONTROL OF THE FOLLOWING: - EG SET RUN - EG SET FUEL LEAK - EG SET FAIL - START SIGNAL (FROM ATS TO EG) - EG SET TROUBLE- EG SET LOW FUEL - VENTILATION CALL (FROM EG TO VENTILATION PANEL VIA THE SIGNAL CABINET. l/ PORTABLE GENERATOR CABLES. ROUTE FROM GENERATOR TO PROPOSED POST-LOK RECEPTACLES VIA THE CABLE TROUGH. PORTABLE CABLE FOR GENERATOR BLOCK HEATER. ROUTE THROUGH CABLE TROUGH TO DEDICATED EG BLOCK HEATER RECEPTACLE. PROPOSED DEDICATED PORTABLE GENERATOR BATTERY CHARGER RECEPTACLE. CONTRACTOR SHALL ROUTE CONDUIT AND WIRING (200) FROM THE RECEPTACLE TO THE LIGHTING PANEL. SEE DWG NO, E10 FOR DETAIL. PROPOSED DEDICATED RECEPTACLE FOR THE BLOCK HEATER. CONTRACTOR SHALL ROUTE CONDUIT AND MOTORIZED WIRING (102) FROM THE RECEPTACLE TO THE SWITCHBOARD. SEE DWG NO. E10 FOR DETAIL. OVERHEAD 1. PROVIDE DISCONNECT SWITCH WITH WEATHERPROOF FLIP UP STYLE COVER, OZ-GEDNEY MODEL NO. WCT1 DOOR, 120 l OR EQUAL. PROVIDE A PHENOLIC ENGRAVED SIGN ABOVE DISCONNECT TO "READ MOTOR DISCONNECT VAC, SINGLE PHASE. SWITCH." SIGN SHALL BE WHITE BACKGROUND WITH 1/2" HIGH BLACK LETTERING. ELECTRICAL EQUIPMENT LEGEND DESCRIPTION MANUFACTURER PART NO. ELECTRICAL HEATER WITH UNIVERSAL MOUNTING BRACKET - 15 KW, 48OV, DAYTON (GRAINGER) 3UF90 O 3-PHASE, WITH 24 VOLT LOW VOLTAGE CONTROL CIRCUIT OR EQUAL. MOUNT BOTTOM OF HEATER 7'-0" FROM FINISHED FLOOR. PHOTO ELECTRIC SMOKE DETECTOR - 12 VDC, WITH LOCAL AUDIBLE ALARM SIGNAL SYSTEMS SENSORS 4WT-B NO © AND CONTACTS FOR REMOTE ANNUNCIATION THROUGH TWO WIRE CONNECTION TO SUBSTITUTIONS TELEMETRY. INSTALL AT HIGHEST POINT. WIRE PER MANUFACTURER'S INSTRUCTIONS. PROVIDE ACCESSORIES AS NECESSARY TO COMPLETE A FUNCTIONAL CIRCUIT. O INTRUSION ALARM SWITCH - HEAVY DUTY INTRUSION ALARM SWITCH. CONTRACTOR SQUARE D TYPE C, CLASS TO SELECT PLUNGER STYLE ACTUATOR. SEE DWG NO. E08 FOR DETAIL. 9007 OR EQUAL ® WALL -MOUNTED HEATING THERMOSTAT - 24 VOLT, SPST, RANGE 40'-100'F, SET DAYTON (GRAINGER) 3UH19 AT 60'F, INTRUSION ALARM SWITCH - HEAVY DUTY INTRUSION ALARM SWITCH (TYPICAL OF SQUARE D TYPE C, CLASS O 4). CONTRACTOR SHALL SELECT ROCKER STYLE LEVER ARM. CONTRACTOR SHALL 9007 OR EQUAL INSTALL TWO (2) SWITCHES FOR INTRUSION AND DOOR FULLY OPEN INDICATION. SEE DWG NO. E08 FOR DETAIL. © TEMPERATURE THERMISTOR. MOUNT THERMIS?OR 4'-0" FROM FINISHED FLOOR. OMEGA EWS-TCT PANIC BUTTON - HEAVY DUTY TYPE, NORMALLY OPEN, CLASS 9001. FURNISH SQUARE D KR9R21H6 OR ® PERMANENTLY MOUNTED "PANIC ALARM - PUSH TO ALARM" SIGN ABOVE EACH EQUAL BUTTON. SIGN TO BE RED WITH 1/4" HIGH WHITE LETTERING. MOUNT PANIC BUTTON S-0" FROM FINISHED FLOOR. I ® KEYED -SWITCH BOX. SEE SPECIFICATIONS & DETAIL ON DWG NO. E08 FOR MORE INFORMATION. ALARM ANNUNCIATION HORN. 24 VDC. UNIT SHALL PRODUCE 99 dB VIBRATONE FEDERAL SIGNAL 450 OR EQUAL SOUND BLAST AT 10- FEET. THE UNIT SHALL BE RATED FOR OUTDOOR USE. STANDARD CONDUCTOR/CONDUIT SCHEDULE MARK CONDUCTORS GROUND CONDUIT MARK CONDUCTORS GROUND CONDUIT MARK CONDUCTORS CONDUIT, 200 (2)-#12 (1)-#12 1/2" 220 (2)-#14 (1)-#14 1/2" 240 (1)-2-CONDUCTOR SHIELDED CABLE 3/4" 201 (3)-#12 (1)-#12 1/2" 221 (4)-#14 (1)-#14 1/2" 241 (2)-2-CONDUCTOR SHIELDED CABLE 3/4" 202 (2)-#10 (1)-#10 1/2" 222 (6)-#14 (1)-#14 1/2" 242 (3)-2-CONDUCTOR SHIELDED CABLE 3/4" 203 (3)-#10 (1)-#10 3/4" 223 (8)-#14 (1)-#14 3/4" 243 (4)-2-CONDUCTOR SHIELDED CABLE 3/4" 204 (2)-#8 (1)-#10 3/4" 224 (10)-#14 (1)-#14 3/4" 244 (5)-2-CONDUCTOR SHIELDED CABLE 1" 205 (3)-#8 (1)-#10 3/4" 224 (12)-#14 (i)-#14 3/4" 245 (6)-2-CONDUCTOR SHIELDED CABLE 1 1 /4" �� (2)-#6 (i)-#10 1" 226) (14)-#14 (1)-#14 1" 246 (7)-2-CONDUCTOR SHIELDED CABLE 1 1/2" 207 (3}-#6 (1)-#10 1" 227 (16)-#14 (1)-#14 1" 7 (8)-2-CONDUCTOR SHIELDED CABLE 1 1/2" 208 (6)-#12 (1)-#12 1 /2" 228 (50)-#14 (1)-#14 1 1 /2"tl*1(9)-2-CONDUCTOR SHIELDED CABLE 2" ! REVISED TO CONFORM TO CONSTRUCTION RECORDS REVISED PER BUILDING PERMIT NCB. REVISION EXPIRES 3 19 2008I SIGNED.- 07128106 4C;4Jx; �rorrni. � EXPIRES 5 14 2008 SIGNED: 07128106 �Y O I 1� T r O J a cc U W i W C) Z I � M Z m � J � O a a Ir W we, J " -RING, INC. mailbox@rh2.com 1.800.720,8052 BELLINGHAM OFFICE 360.676.0836 454 West Horton Rood l L OFFICE 12100 NE 195th Street, Suite 100 !I I CHEE OFFIC 5C, -- 300 Simon Street, Suite 5 PORT ORCHARD OFFICE 360.876.7960 j 600 Kitsap Street, Suite 101 REN CMR MLM 11/01/07 RPC MLM 08/17/06 JOBNa.: 105-079 33 BY REVIEW DATE FILENAME. GEN-D-E04 y N );w-323111