Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WTR2703239.28
MOTORIZED INTAKE LOUVER, 120 VAC. SINGLE PHASE. [�Pt Z:I:1 � 1 �> ■ �I�I�I :� WALL MOUNTED 2 GANG BOX. HQA LIGHT SWITCH (TYPICAL). SEE LIGHTING CIRCUIT LOGIC DETAIL ON DWG NO. E08 FOR MORE INFORMATION_ ENTRANCE DOORWAY "- PROPOSED UTILITY METER. TO P.S.E. SERVICE TRANSFORMER FOR TERMINATION BY P.S.E. SEE DWG NO'S. E03 AND C08 FOR MORE INFORMATION. STANDARD CONDUCTOR/CONDUIT SCHEDULE MARK CONDUCTORS GROUND CONDUIT MARK CONDUCTORS GROUND CONDUIT MARK CONDUCTORS CONDUIT 200 (2)-#12 (1)-#12 1 /2" 220 (2)-#14 (1)-114 1 /2" 240 (1)-2-CONDUCTOR SHIELDED CABLE 3/4" 201 (3)-#12 (1)-#12 1 /2" 221 (4)-#14 (1)-#14 1 /2" 241 (2)-2-CONDUCTOR SHIELDED CABLE 3/4- (2) - #10 (1)-#10 1 /2" 222 (6)-#14 (1)-#14 1 /2" 242 (3)- 2- CONDUCTOR SHIELDED CABLE 3/4- (3) - #10 (1)-#10 3/4" 223 (8)-#14 (1)-#14 3/4" 243 (4)-2-CONDUCTOR SHIELDED CABLE 3/4" 204 (2)-#8 (1)-#10 3/4" 224 (10)-#14 (1)-#14 3/4" 244 (5)-2-CONDUCTOR SHIELDED CABLE 1" 205 (3)-#8 (1)-#10 3/4" 225 (12)-#14 (1)-#14 3/4" 245 (6)-2-CONDUCTOR SHIELDED CABLE 1 1 /4" 206 (2)-#6 (1)-#10 1" 226 (14)-#14 (1)-#14 1" 246 (7)-2-CONDUCTOR SHIELDED CABLE 1 1/2" 207 (3)-#6 (1)-#10 1" 227 (16)-#14 (1)-#14 1" 27 I(8)-2-CONDUCTOR SHIELDED CABLE 1 1/2" 208 (2)-#6 (1)-#8 1" 228 (18)-#14 (1)-#14 1" 248 (9)-2-CONDUCTOR SHIELDED CABLE 2" 209 (3)-#6 (1)-#8 1" 229 (20)-#14 (1)-#14 1" 249 (10)-2-CONDUCTOR SHIELDED CABLE 2" 210 (3)-#4 (1)-#8 1 1 /4" 230 (24)-#14 (1)-#14 1 1 /4" 250 (1)-3-CONDUCTOR SHIELDED CABLE 1" 211 (3)-#3 (1)-#8 1 1 /4" 231 (25)-#14 (1)-#14 1 1 /4" 251 (1)-4-CONDUCTOR SHIELDED CABLE 1" 212 (3)-#2 (1)-#6 1 1 /2" 232 (30)-#14 (1)-#14 1 1 /4" 252 MANUFACTURER'S CABLE 1 /2" 213 (3)-#1 (1)-#6 1 1 /2" 233 (32)-#14 (1)-#14 1 1 /4" 253 TELEPHONE CABLE (1-PAIR) 1 /2" 214 (4)-#12 l(l)-#12 1 /2" 234 (36)-#14 (1)-#14 1 1 /4" 254 TELEPHONE CABLE (2-PAIR) 1/2- (1) 3/8" NYLON PULL CORD 1 /2" 235 (40)-#14 (1)-#14 1 1 /4" 255 TELEPHONE CABLE (4 PAIR) 3/4" 216 (1) 3/8" NYLON PULL CORD 1" 236 (42)-#14 (1)-#14 1 1/2" 256 TELEPHONE CABLE (6-PAIR) 1" 217 MANUFACTURER'S CABLE 1" 237 (48)-#14 (i)-#14 1 1/2" 257 NETWORK CABLE 1" nX DENOTES CONDUCTORS SHARING A SINGLE CONDUIT. CONTRACTOR SHALL UPSIZE CONDUIT IF NECESSARY. I� SEE DWG NO. C08 FOR CONTINUATION. ELECTRICAL PLAN 1" — 2'— On TO EXISTING NEW ELECTRICAL RESTROOM BUILDING SERVICE TO RESTROOM ADDED PER COP NO. 13 204 "Ax VAC, SINGLE PHASE. W*323142b TO NORTH TALBQT BOOSTER PUMP STATION. SEE DWG NO. C08 FOR CONTINUATION. 102 PROPOSED SWITCHBOARD. SEE I % DWG NO. E07 FOR DETAIL. 5' 6" j GROUND ROD PER N.E.C. (TYPICAL). USE EXOTHERMIC WELD CONNECTION AT THE GROUND ROD. LOCATE GROUND RODS 2' MINIMUM FROM BUILDING FOUNDATION. SEE DWG NO. E08 FOR MORE INFORMATION. REVISED TO CONFORM TO CONSTRUCTION RECORDS 1101 / / 2007 RH2 ENGINEERING INC. DATE NOT ELECTRICAL EQUIPMENT LEGEND DESCRIPTION MANUFACTURER PART NO. ELECTRICAL HEATER WITH UNIVERSAL DAYTON (GRAINGER) 3UF87 MOUNTING BRACKET - 10 KW, 48OV, © 3-PHASE, WITH 24 VOLT LOW VOLTAGE CONTROL CIRCUIT OR EQUAL. MOUNT BOTTOM OF HEATER 7'-0" FROM FINISHED FLOOR. PHOTO ELECTRIC SMOKE DETECTOR - 12 SYSTEM SENSORS 4WT-B NO VDC, WITH LOCAL AUDIBLE ALARM SIGNAL SUBSTITUTIONS AND CONTACTS FOR REMOTE ANNUNCIATION Q THROUGH TWO WIRE CONNECTION TO TELEMETRY. INSTALL AT HIGHEST POINT. WIRE PER MANUFACTURER'S INSTRUCTIONS. PROVIDE ACCESSORIES AS NECESSARY TO COMPLETE A FUNCTIONAL CIRCUIT. INTRUSION ALARM SWITCH - HEAVY DUTY SQUARE D TYPE C, CLASS INTRUSION ALARM SWITCH. CONTRACTOR TO 9007 OR EQUAL O SELECT PLUNGER STYLE ACTUATOR. SEE DWG NO. E08 FOR DETAIL. WIRE IN SERIES WITH OVERHEAD DOOR INTRUSION SWITCHES. WALL -MOUNTED HEATING THERMOSTAT - 24 DAYTON (GRAINGER) 3UH19 © VOLT, SPST, RANGE: 40'-100'F, SET AT 60'F. INTRUSION ALARM SWITCH - HEAVY DUTY SQUARE D TYPE C, CLASS INTRUSION ALARM SWITCH. CONTRACTOR 9007 OR EQUAL O SHALL SELECT ACTUATOR LEVER ARM BEST SUITED FOR MOUNTING CONFIGURATION. SEE DWG NO. E08 FOR DETAIL. WIRE IN SERIES WITH OVERHEAD DOOR INTRUSION SWITCH. O TEMPERATURE THERMISTOR. MOUNT OMEGA EWS-TCT OR THERMISTOR 4'-0" FROM FINISHED FLOOR. EQUAL PANIC BUTTON - HEAVY DUTY TYPE, SQUARE D KR9R21H6 OR NORMALLY OPEN, CLASS 9001. FURNISH EQUAL PERMANENTLY MOUNTED "PANIC ALARM - © PUSH TO ALARM" SIGN ABOVE EACH BUTTON. SIGN TO BE RED WITH 1/4" HIGH WHITE LETTERING. MOUNT PANIC BUTTON S-0" FROM FINISHED FLOOR. KEYED -SWITCH BOX. SEE SPECIFICATIONS O AND DETAIL ON DWG NO. E08 FOR MORE INFORMATION. ALARM ANNUNCIATION HORN. 24 VDC. FEDERAL SIGNAL 450 OR EQUAL O UNIT SHALL PRODUCE 99 dB VIBRATONE SOUND BLAST AT 10- FEET. THE UNIT SHALL BE RATED FOR OUTDOOR USE. I ELECTRICAL NOTES INTRUSION WIRING. WIRE INTRUSION SWITCHES IN SERIES. ROUTE INTRUSION WIRING TO SIGNAL CABINET. WIRING FROM THE AUTOMATIC TRANSFER SWITCH TO THE SIGNAL CABINET FOR GENERATOR START AND ATS FAIL SIGNALS. 3 TO BPS TELEMETRY PANEL FOR REMOTE INDICATION OF THE FOLLOWING SIGNALS: - EG SET RUN - EG SET FUEL LEAK - INTRUSION ALARM - EG SET FAIL - INTRUSION DISABLE - EG SET TROUBLE - SMOKE DETECTOR - PANIC ALARM - EG SET LOW FUEL - ATS FAIL ALARM - VENTILATION CALL - 6 SPARE WIRES - BUILDING TEMPERATURE (4-20 mA) - 12VDC POWER FOR SMOKE DETECTOR 4 PROVIDE AUTOMATIC PUSHBUTTON OVERHEAD DOOR OPERATOR FOR THE OVERHEAD DOOR. INSTALL 4'-0" FROM THE FINISHED FLOOR, LOCATE DOOR OPERATOR TO LEFT OF OVERHEAD DOOR. 5 EG MOUNTED PORTABLE CABLE FOR POWER TO THE GENERATOR LIGHTING. ROUTE THROUGH CABLE TROUGH TO DEDICATED RECEPTACLES. 6 PORTABLE GENERATOR SIGNAL CABLE. ROUTE CABLE THROUGH CABLE TROUGH TO SIGNAL CABINET FOR REMOTE INDICATION AND CONTROL OF THE FOLLOWING: - EG SET RUN - EG SET FUEL LEAK - EG SET FAIL - EG SET LOW FUEL - EG SET TROUBLE - START SIGNAL (FROM ATS TO EG) - VENTILATION CALL (FROM EG TO VENTILATION PANEL VIA THE SIGNAL CABINET). 7 PORTABLE GENERATOR POWER CABLES. ROUTE FROM GENERATOR TO PROPOSED POST-LOK RECEPTACLES VIA THE CABLE TROUGH. 8 EG MOUNTED PORTABLE CABLE FOR POWER TO THE PORTABLE BATTERY CHARGER. ROUTE THROUGH CABLE TROUGH TO DEDICATED RECEPTACLES. 9 EG MOUNTED PORTABLE CABLE FOR POWER TO THE EG BLOCK HEATER. ROUTE THROUGH CABLE TROUGH TO DEDICATED RECEPTACLES. PROPOSED DEDICATED ENGINE GENERATOR LIGHTING RECEPTACLE, CONTRACTOR SHALL ROUTE CONDUIT AND WIRING (200) FROM THE RECEPTACLE TO THE LIGHTING PANEL. SEE DWG NO. E10 FOR DETAIL. 11 PROPOSED DEDICATED PORTABLE GENERATOR BATTERY CHARGER RECEPTACLE. CONTRACTOR SHALL ROUTE CONDUIT AND WIRING (200 } FROM THE RECEPTACLE TO THE LIGHTING PANEL. SEE DWG NO. E10 FOR DETAIL. PROPOSED DEDICATED RECEPTACLE FOR THE BLOCK HEATER. CONTRACTOR SHALL ROUTE CONDUIT AND WIRING (202) FROM THE RECEPTACLE TO THE SWITCHBOARD. SEE DWG NO. E10 FOR DETAIL. 3 PROVIDE DISCONNECT SWITCH WITH WEATHERPROOF FLIP UP STYLE COVER, OZ-GEDNEY MODEL NO. WCT1 OR EQUAL. PROVIDE A PHENOLIC ENGRAVED SIGN ABOVE DISCONNECT TO "READ MOTOR DISCONNECT SWITCH." SIGN SHALL BE WHITE BACKGROUND WITH 1/2" HIGH BLACK LETTERING. NOTE: ALL CONDUIT SHALL BE SURFACE MOUNTED WITH THE EXCEPTION OF LIGHTING AND RECEPTACLE CIRCUITS WHICH SHALL BE CONCEALED IN WALLS AND THE CEILING. REVISED TO CONFORM TO CONSTRUCTION RECORDS CMR MLM REVISED PER BUILDING PERMIT RPC MLM REVISION BY REVIEW SIGNED. 07128106 EXPIRES 5 14 20086 SIGNED. • 07128106 voolt 2�a Rl,- , IV 1 � www.❑. ,.., r7,ailbox®rh2.com 1.800.720.8052 f`lcf_ 360.676.0836 454 West Horton Road __L OFFICE 425.951.5400 12100 NE 195th Street, Suite 100 FAST WENATCHEE OFFICE 509.886.2900 300 Simon Street, Suite 5 PORT ORCHARD OFFICE 360.876.7960 600 Kitsap Street, Suite 101 SCALE: SHOWN t TO SCALE F BAR IS NOT 2" LONG PLOT 24 DWG NO, E05 ENGINEER: DJB REVIEWED: MM DATE: NOV 9, 2007 SHEET No. 33 11 /01 /07 CJENT. REN 08/17/06 doe NO.: 105-079 DATE I 'LENAME: GEN-D-EO5 N 1 W N W