HomeMy WebLinkAboutWTR2703239.29CEI H --o 0--- 120 P N— — — — — — — — — HAND —AUTO SWITCH 1 2 3 4 CR2 CR4 HAND / AUTO 15A BUILDING INTAKE LOUVER ----------------- 15A — —� l r BUILDING EXHAUST -- — -0 — ` T --�— M FAN - - - - - - - - - - - - - - - --- 15A _ GENERATOR INTAKE LOUVER ----------------J 15A GENERATOR EXHAUST LOUVER 120 VAC VENTILATION CALL 3 CR1 CR1 CR2 CR1 �,. � PORTABLE EG AUXILIARY CONTACT CR3 STATIONARY EG AUXILIARY CONTACT CR3 CR4 NOTES: 1. THE MT. OLIVET GENERATOR BUILDING HAS TWO OVERHEAD DOORS THAT SHALL OPEN WHEN EITHER GENERATOR IS CALLED TO I START FROM A SIGNAL FROM THE GENERATORS. 2. LOUVERS ARE POWERED CLOSED. _ V OVERHEAD CR5-1 DOOR #1 i INTAKE/EXHAUST — MOTOR START YJ OVERHEAD VENTILATION CALL CR5-2 DOOR #2 FROM TELEMETRY L— VENTILATION START v BUILDING EXHAUST FAN REQUIRED GENERATOR RUNNING GENERATOR LOUVER CALL OVERHEAD DOOR OPEN CALL TR1 TIME DELAY RELAY, SET AT 5 SECONDS. / 9 W GENERATOR VENTILATION SYSTEM REQUIRED OVERHEAD DOOR NO.1 OVERHEAD DOOR NO. 2 TR1 FULLY OPEN FULLY OPEN 10 CR5 PROGRAMMABLE ONE SHOT RELAY (TRIGGER = POWER ON) WHEN TR1 IS ENERGIZED AND THE OVERHEAD DOORS ARE CLOSED, RELAY CR4 SHALL BE MOMENTARILY ENERGIZED FOR A USER ADJUSTABLE TIME INITIALLY SET TO 0.5 SECONDS TO OPEN THE OVERHEAD DOOR. i MT. OLIVET VENTILATION & AUTOMATIC DOOR CONTROL LOGIC TYPICA 5 6 7 8 CR4 NO SCALE 24 V POWER SOURCE FROM OVERHEAD DOOR ACTUATOR WALL MOUNTED OPEN/CLOSE PUSHBUTTON CR5-1 RTU DOOR CLO`. 0 OVERHEAD DOOR MOTOR ACTUATOR j I E: LABEL CR5 CONTACT AS FOLLOWS: CR5-1 FOR OVERHEAD DOOR #1 CR5-2 FOR OVERHEAD DOOR #2 CALL FROM TELEMETRY TO CLOSE DOOR L MT. OLIVET OVERHEAD DOOR MOTOR ACTUATOR CONTROL LOGIC L NO SCALE ON 120V HAND SWITCH OFF — — — AUTO PHOTO CELL CONTROL LIGHTING CIRCUIT LOGIC DETAIL NO SCALE A2 N SEE PLANS FOR NUMBER OF OUTDOOR LIGHTS. a CB H--1. -- 120 P N— — — — — — — — — N— — — — — — — — — 120 P CB H ---0 0--- HAND —AUTO SWITCH 14 2 3 4 CR2 CR3 HAND / AUTO 15A BUILDING INTAKE LOUVER - - - - - - - - - - - - - - - - 'J 15A __(::BUILDING EXHAUST FAN 15_ A GENERATOR INTAKE LOUVER ----------------J 120 VAC 24 VAC VENTILATION CALL 3, 5 CR1 INTAKE/EXHAUST MOTOR START VENTILATION CALL FROM TELEMETRY CR1 I CR2 --� MOTOR START CR1 ' W BUILDING EXHAUST FAN REQUIRED j PORTABLE EG AUXILIARY CONTACT 5 ---— CIR3 INTAKE LOUVER CALL CR3 GENERATOR VENTILATION A SYSTEM REQUIRED . TALBOT VENTILATION CONTROL LOGIC *. NO SCALE NO 1: THE NORTH TALBOT GENERATOR BUILDING HAS ONE OVERHEAD DOOR AND ONE ENGINE GENERATOR INTAKE LOUVER, THE OVERHEAD DOOR AT THE NORTH TALBOT GENERATOR BUILDING WILL NOT BE WIRED TO OPEN WHEN THE GENERATOR IS CALLED TO START. SIZE PANEL AS NECESSARY VENTILATION CONTROL TO CONTAIN VENTILATION PANEL LABEL, I_AQEL PER CONTROL LOGIC DEVICES. SPECIFICATIONS. VENTILA11ON & AUTOMATIC OVERHEAD DOOR I I CONTROL PANEL i HAND —AUTO SWITCH (TYPICAL). HAND AUTO SWITCH BUILDING EXHAUST FAN REQUIRED 0 GENERATOR VENTILATION SYSTEM REQUIRED 0 VENTILATION CONTROL PANEL FRONT VIEW NOT TO SCALE NORTH TALBOT LABEL SHALL READ VENTILATION CONTROL PANEL. W-323929 REVISED TO CONFORM TO CONSTRUCTION RECORDS ' // 11 /01 /2007 RH2 ENGINEERING INC. DATE 1 REVISED TO CONFORM TO CONSTRUCTION RECORDS REVISED PER SUBMITTAL NO. 18 REVIEW COMMENTS NO. REVISION EXPIRES 3719 2008 SIGNED: 07128106 EXPIRES 5/14/2008 SIGNED. 071281106 Q �,' � R 1 1A;t 7.rv0 0 0 z 0 V a � V 0 C)c 0 z W W �I i i SING, it4 I mailbox®rr. 1.800.720.8052 BELLINGHAM OFFICE 360.676.0836 ^54 West Horton Rood 12100 NE 195th Street, Suite 100 WE NATCHEE OFFIC -�86.2900 300 Simon Street, Suite 5 PORT ORCHARD OFFIC 360.876.7960 600 Kitsap Street, Suite 101 SCALE: SHOWN 0 i" 21' DRAWING IS NOT TO SCALE IF BAR IS NOT 2" LONG PLOT: 1 DWG NO ENGINEER: DJB E06 REVEWED: MM DATE: NOV 2, 2007E=, `' CMR MLM 11 /01 /07 : REN 29 CMR MLM 11 /21 /06 jOB NO.: 105-079 7 33 BY REVIEW DATE FILENAME: GEN—D—E06 Au W , '�231201