HomeMy WebLinkAboutWTR2703239.30I NOTE: CONTRACTOR SHALL PROVIDE A TOTAL OF 2 SIGNAL CABINETS. CABINETS SHALL BE LOCATED AT THE FOLLOWING LOCATIONS- - PROPOSED MT. OLIVET GENERATOR BUILDING. - PROPOSED NORTH TALBOT GENERATOR BUILDING. SEE SPECIFICATIONS FOR MORE INFORMATION. CONTRACTOR SHALL INSTALL TERMINAL BLOCKS IN PROPOSED SIGNAL CABINET FOR CONNECTION OF FIELD DEVICES TO THE EXISTING TELEMETRY PANEL. TB1 CONDUIT TO FIELD DEVICES (TYPICAL). CONDUIT TO EXISTING TELEMETRY PANEL. NEMA 12 TYPE ENCLOSURE WITH BA.CKPAN, MOUNT ENCLOSURE 6'-0" FROM FINISHED FLOOR. SIZE PANEL AS NECESSARY TO CONTAIN ALL CONTROL SIGNALS. TYPICAL SIGNAL CABINET INTERIOR VIEW NOT TO SCALE ------------ MT. OLIVET GENERATORBUILDING SIGNAL CABINET KEY LOCK HANDLE. PIN, 7 WIRE PANEL MOUNTED RECEPTACLE FOR SIGNALIZATION TO PORTABLE GENERATOR. SEE - SPECIFICATIONS AND SIGNAL CABINET TERMINAL BLOCK SET SCREW ASSIGNMENT TABLES THIS SHEET FOR RECEPTACLE SOCKET ASSIGNMENTS. TYPICAL SIGNAL CABINET EXTERIOR VIEW NOT TO SCALE SCREW ASSIGNMENTS REVISED PER RFI-042RO03 RECEPTACLE REVISED l� FROM 10 PIN TO 7 PIN PER RFI-042. MT. OLIVET SIGNAL CABINET TERMINAL BLOCK SET SCREW ASSIGNMENTS SIGNAL ORIGIN SIGNAL DESCRIPTION SIGNAL CABINET I SIGNAL DESTINATION ! RECEPTACLE SOCKET TB TERMINATION POINT WELLS 1, 2 & 3 ATS ' ATS START TB §1 - SET SCREWS 1 & 2 STATIONARY EG SET WELLS 1, 2 & 3 ATS ATS FAIL TB #1 - SET SCREWS 3 & 4 MT. OLIVET BPS TELEMETRY PANEL MT. OLIVET ATS ATS START #3 & TB #1 - SET SCREWS 5 & 6 SIGNAL CABINET RECEPTACLE PLUG SOCKET MT. OLIVET ATS ATS FAIL TB #1 - SET SCREWS 7 & 8 MT. OLIVET BPS TELEMETRY PANEL STATIONARY EG EG RUN TB 1 - SET SCREWS 9 & 10 MT. OLIVET BPS TELEMETRY PANEL STATIONARY EG EG FAIL TB #1 - SET SCREWS 11 & 12 MT. OLIVET BPS TELEMETRY PANEL STATIONARY EG EG TROUBLE TB #1 - SET SCREWS 13 & 14 MT. OLIVET BPS TELEMETRY PANEL STATIONARY EG EG LOW FUEL TB #1 - SET SCREWS 15 & 16 MT. OLIVET BPS TELEMETRY PANEL STATIONARY EG EG FUEL LEAK TB #1 - SET SCREWS 17 & 18 MT. OLIVET BPS TELEMETRY PANEL STATIONARY EG VENTILATION CALL I TB #1 -SET SCREWS 19 & 20 VENTILATION CON TROL PANEL 1 PORTABLE EG EG RUN #4 TB #1 - SET SCREWS 21 & 22 MT. OLIVET BPS TELEMETRY PANEL PORTABLE EG EG FAIL #2 TB #1 - SET SCREWS 23 & 24 MT. OLIVET BPS TELEMETRY PANEL PORTABLE EG EG TROUBLE #2 TB J1 - SET SCREWS 25 & 26 MT. OLIVET BPS TELEMETRY PANEL PORTABLE EG EG LOW FUEL 2 TB 11 - SET SCREWS 27 & 28 MT, OLIVET BPS TELEMETRY PANEL PORTABLE EG EG FUEL LEAK #2 TB #1 - SET SCREWS 29 & 30 MT. OLIVET BPS TELEMETRY PANEL PORTABLE EG VENTILATION CALL #5 & #7 TB #2 - SET SCREWS 1 & 2 VENTILATION CONTROL PANEL SMOKE DETECTOR SMOKE ALARM TB #2 - SET SCREWS 3 & 4 MT. OLIVET BPS TELEMETRY PANEL MT. OLIVET BPS TELEMETRY PANEL 12 VDC POWER TB #2 - SET SCREWS 5 & 6 SMOKE DETECTOR OVERHEAD DOOR #1 INTRUSION SWITCH INTRUSION TB #2 - SET SCREWS 7 & 8 MT. OLIVET BPS TELEMETRY PANEL OVERHEAD DOOR #1 LIMIT SWITCH DOOR FULLY OPEN INDICATION TB #2 - SET SCREWS 9 & 10 MT. OLIVET BPS TELEMETRY PANEL OVERHEAD DOOR #2 INTRUSION SWITCH INTRUSION TB #2 - SET SCREWS 11 & 12 MT. OLIVET BPS TELEMETRY PANEL OVERHEAD DOOR #2 LIMIT SWITCH DOOR FULLY OPEN INDICATION TB #2 - SET SCREWS 13 & 14 MT. OLIVET BPS TELEMETRY PANEL MAN DOOR INTRUSION SWITCH INTRUSION TB #2 - SET SCREWS 15 & 16 MT. OLIVET BPS TELEMETRY PANEL PANIC BUTTON PANIC ALARM TB 2 - SET SCREWS 17 & 18 MT. OLIVET BPS TELEMETRY PANEL MT. OLIVET BPS TELEMETRY PANEL VENTILATION CALL TB #2 - SET SCREWS 19 & 20 MT. OLIVET VENTILATION PANEL INTRUSION DISABLE KEYED SWITCH BOX INTRUSION DISABLE TB #2 - SET SCREWS 21 & 22 MT, OLIVET BPS TELEMETRY PANEL BUILDING TEMPERATURE THERMISTOR BUILDING TEMP 4-20 MA TB 2 - SET SCREWS 23 & 24 MT. OLIVET BPS TELEMETRY PANEL SPARE TB #2 - SET SCREWS 25 & 26 SPARE ITB #2 - SET SCREWS 27 & 281 SPARE JTB #2 - SET SCREWS 29 & 30 NORTH TALBOT SIGNAL CABINET TERMINAL BLOCK SET SCREW ASSIGNMENTS ORIGIN SIGNAL DESCRIPTION SIGNAL CABINET DESTINATION RECEPTACLE SOCKET # TB TERMINATION POINT NORTH TALBOT ATS ATS START #3 & #6 TB #1 - SET SCREWS 1 & 2 SIGNAL CABINET RECEPTACLE PLUG SOCKET NORTH TALBOT ATS ATS FAIL TB #1 - SET SCREWS 3 & 4 NORTH TALBOT BPS ELEME7Y PANEL PORTABLE EG EG RUN #4 TB #1 - SET SCREWS 5 & 6 NORTH TALBOT BPS TELEMETRY PANEL PORTABLE EG EG FAIL #2 TB #1 - SET SCREWS 7 & 8 NORTH TALBOT BPS TELEMETRY PANEL PORTABLE EG EG TROUBLE #2 TB #1 - SET SCREWS 9 & 10 NORTH TALBOT BPS TELEMETRY PANEL PORTABLE EG EG LOW FUEL 12 TB #1 - SET SCREWS 11 & 12 NORTH TALBOT BPS TELEMETRY PANEL PORTABLE EG EG FUEL LEAK #2 TB #1 - SET SCREWS 13 & 14 NORTH TALBOT BPS TELEMETRY PANEL PORTABLE EG VENTILATION CALL 15 & #7 TB #1 - SET SCREWS 15 & 16 NORTH TALBOT BPS TELEMETRY PANEL SMOKE DETECTOR SMOKE ALARM TB #1 - SET SCREWS 17 & 18 NORTH TALBOT BPS TELEMETRY PANEL NORTH TALBOT BPS TELEMETRY PANEL 12 VDC POWER TB #2 - SET SCREWS 1 & 2 SMOKE DETECTOR FOR POWER TO DETECTOR DOOR INTRUSION SWITCHES INTRUSION TB #2 - SET SCREWS 3 & 4 NORTH TALBOT BPS TELEMETRY PANEL PANIC BUTTON PANIC ALARM TB #2 - SET SCREWS 5 & 6 NORTH TALBOI BPS TELEMETRY PANEL NORTH TALBOT BPS TELEMETRY PANEL VENTILATION CALL TB #2 - SET SCREWS 7 & 8 VENTILATION CONTROL PANEL INTRUSION DISABLE KEYED SWITCH BOX INTRUSION DISABLE TB #2 - SET SCREWS 9 & 10 NORTH TALBOT BPS TELEMETRY PANEL BUILDING TEMPERATURE THERMISTOR BUILDING TEMP 4-20 mA TB #2 - SET SCREWS 11 & 12 NORTH TALBOT BPS TELEMETRY PANEL SPARE TB #2 - SET SCREWS 13 & 14 SPARE TB #2 - SET SCREWS 15 & 16 SPARE ITB #2 - SET SCREWS 17 & 18 SCREW ASSIGNMENTS REVISED PER RFI-042RO03 A MT. OLIVET GENERATOR BUILDING PANEL SCHEDULE LOCATION: LIGHTING PANEL SERVING: GENERATOR BUILDING AB I ! 1 I 2 3 4 5 6 7 8 9 10 1 i `�12 13 14 15 16 17 18 120/240 60 AMP VOLTS 3 WIRE MAIN CIRCUIT DESCRIPTION KVA AMP�60A AMP KVA CIRCUIT DESCRIPTION GFI RECP CKT. #1, 120V 0.5 20 20 0.$ INTERIOR LIGHTING, 120V GFI RECP CKT. #2, 120V 0.5 20 20 1 0.3 EXTERIOR LIGHT, 120V VENTILATION PANEL, (MOTOR PWR) 0.5 20 20 0.5 WALL MOUNTED BATTERY CHARGER, 120V VENTILATION PANEL, (CTRL LOGIC) 0.2 20 20 0.5 BATTERY CHARGER RECEPTACLE, 120V OVERHEAD DOORS CKT 11, 120V 1.75 20 20 1.75 OVERHEAD DOORS, CKT #2, 120V I REMOTE FILL STATION 120V 0.2 20 20 1 - SPARE SPARE - 1 20 20 - SPARE SPARE - 20 - - SPACE I SPACE , - I - - - SPACE CONNECTION LOAD: DEMAND: LIGHTING & MISC. LOAD DEMAND LOAD: 7.5 KVA 31.25 AMPS 7.5 KVA 31.25 AMPS i NORTH TALBOT GENERATOR BUILDING PANEL SCHEDULE LOCA T ION: SWITCHBOARD SERVING: GENERATOR BUILDING SECTION 3 AB 60A 1 2 3 -r' 4 5 6 7 6 9 -10 11 12 13 j 4 15 16 17 1 S 120/240 100 VOLTS 3 WIRE AMP MAIN CIRCUIT DESCRIPTION KVA AMP AMP KVA CIRCUIT DESCRIPTION IINTERIOR LIGHTING, 120V 0.6 20 20 0.3 EXTERIOR LIGHT, 120V GFI RECP CKT. #1, 120V 0.5 20 20 0.5 GFI RECP CKT. #2, 120V I VENTILATION PANEL, (MOTOR PWR) 0.4 20 20 0.2 EG LIGHTING RECEPTACLE I VENTILATION PANEL, (CTRL LOGIC) 0.2 20 30 2.5 DEDICATED EG BLOCK HEATER CKT 1OVERHEAD DOOR ' 0.8 20 20 0.5 DEDICATED BATTERY CHARGER CKT ARE - 20 20 - SPARE SPARE 20 20 - SPARE ;SPACE - - - I - SPACE j !SPACE - - - - SPACE CONNECTION LOAD: DEMAND: LIGHTING LOAD DEMAND LOAD: L7 3 KVA 30.4 AMPS 7.3 KVA 30.4 AMPS FACILITY LIGHTING FIXTURE SCHEDULE MANUFACTURER * LAMP TYPE DESCRIPTION NAME CATALOG NO. QTY. CATALOG NO, REMARKS Al FLUORESCENT LIGHT FIXTURE, 120 VAC, 4' LONG, HIGH -IMPACT ACRYLIC LENS, MOLDED FIBERGLASS REINFORCED POLYESTER HOUSING, (2)-32W LAMPS, ENERGY SAVING BALLAST, CEILING MOUNTED, U.L. ( LITHONIA VRI 2 32 ARDP 120 CW 2 32WT8 32 WATT I LISTED FOR DAMP LOCATIONS. FLUORESCENT OUTDOOR AREA LIGHT - 42W, 12OV BALLAST, A2 DIE-CAST ALUMINUM HOUSING, POLYCARBONATE LENS, U.L. LISTED FOR WET LOCATIONS. MOUNT TOP OF FIXTURE 8'-6" FROM FINISHED LiTHONIA = TWH 2/42 120 PE LPI 1 I 42 WATT PHOTOCELL CONTROL GRADE. i w 41P 313430 REVISED TO CONFORM TO CONSTRUCTION RECORDS � � s 11 /01 /2007 RH2 ENGINEERING INC. DATE REVISED TO CONFORM TO CONSTRUCTION RECORDS CMR MLM N0. REVISION BY REVIEW 11/01/07 DATE SIGNED: 07128106 EXPIRES 5 14/2008 SIGNED.- 07,/28/06 Y i � AT J Q 14.0 U_ U O W J W cn O ZZ Ill ,J W W J U m C)c 2 W Z z m � Q J Q Z 0 U) lvw kill 0 wu RH2 ENGIK:i:, _'RING. INC. http: //www.rh2.com mailbox0rh2.com 1, 800.720.8052 BELLINGHAM OFFICE 360.676.0836 454 West Horton Road 425.95 .5400 12100 NE 195th Street, Suite 100 FAST WENATCHEE OFFIC 509.886.2900 300 Simon Street, Suite 5 PORT ORCHARD OFFICE 360.876.7960 600 Kitsap Street, Suite 101 C ■ OT I 65*�vw*R*R DRAWING -7 O SCALE IF BAR IS NOT 2" i ONG PLOT: I ENGINEER: DJB E 10 REVIEWS : MM DATE: NOV 2, 2007 cuE . REN 30 jai NO.: 105-079 T!LENAME: GEN-D-E10 b CD CD W 0 0 W N 0 W N W