HomeMy WebLinkAboutWTR2703239.32�vir'n\In -MAklf r-nnk ir-n NOTE: 1. TRANSFORMER DOORS NOT SHOWN THIS DETAIL FOR CLARII 2. TRANSFORMER AT MT. OLIVE; SITE MAY DIFFER FROM TYPE 01 TRANSFORMER SHOWN IN THIS DETAIL. EXISTING PRIMARY CONDUCTORS. EXISTING PRIMARY CONDUIT. PROPOSED SECONDARY CONDUCTORS. SEE DWG NO. E02 FOR CONDUCTOR SIZING. PROPOSED SECONDARY CONDUITS. EXISTING CONDUIT TO SWITCHGEAR. SEE AND CONDUCTORS DWG NO, CO3 FOR TO PSE. CONTINUATION. TRANSFORMER CONNECTION DETAIL NOT TO SCALE 2'-6" EXISTING CONDUIT FROM THE EXISTING MT. OLIVET BOOSTER PUMP STATION TRANSFORMER (TYPICAL). CONTRACTOR SHALL INTERCEPT EXISTING CONDUITS IN ORDER TO REUSE EXISTING SERVICE ENTRANCE CONDUITS AND CONDUCTORS TO SUPPLY POWER TO THE EXISTING MT. OLIVET BOOSTER PUMP STATION. 2'-6" PROPOSED UTILITY VAULT MODEL NO. 3030-1-A OR EQUAL. PROPOSED CONDUIT AND CONDUCTORS TO THE MT, OLIVET GENERATOR BUILDING (TYPICAL). n EXISTING CONDUIT TO BE REMOVED. EXISTING CONDUIT AND CONDUCTORS TO THE EXISTING MT. OLIVET BOOSTER PUMP STATION. PROPOSED CONDUCTORS. SEE DWG NO. E02 FOR CONDUCTOR SIZING. CONDUIT INTERCEPTION DETAIL NOT TO SCALE 8"W x 6"H x 1 /4" D SS. PLATE. ATTACH PLATE TO C CHANNEL USING 1 /4" SS STEEL HARDWARE. SECURE IN A MINIMUM OF TWO LOCATIONS. CONDUIT TO RECEPTACLI (TYPICAL; BEARING PLATE. SECURE TO FLOOR USING (4) 1/4" SS CONCRETE ANCHORS, RECEPTACLE FOR PORTABLE GENERATOR POWER (TYPICAL). MOUNT TOP OF RECEPTACLE 3'-0" ABOVE FINISHED FLOOR. SECURE TO SS PLATE USING 1/4" SS HARDWARE. SECURE IN A MINIMUM OF TWO LOCATIONS. 2" GALVANIZED CHANNEL. PORTABLE GENERATOR RECEPTACLE MOUNTING DETAIL REMOTE FILL STATION DETAIL NOT TO SCALE 3" BRASS BALL VALVE. ITE FUEL FILL STATION. SPECIFICATIONS FOR INFORMATION. ABOVE GRADE CARRIER PIPE ELIMINATED AND REPLACED WITH A 14 GA. GALVANIZED STEEL SHROUD TO ENCLOSE CONTAINMENT PIPE PER RFI-066. SCHEDULE 80 R PIPE FOR I )ARY CONTAINMENT 3" FUEL LINE. ORS ADDEC REMOTE FILL RMS PER W 323932 TO EG FUEL TANK. 3" DIAMETER FUEL LINE, ENVIRON GEOFLEX D DOUBLE WALL PIPING OR EQUAL. PROVIDE WITH 6" PVC SCH. 80 CARRIER PIPE. / SHUTOFF VALVE AND ROUTE PRo\AnF I INK ';FAI AT Al l �' THROUGH CARRIER PIPE. CONCRETE PENETRATIONS. ENGINE GENERATOR. CONCRETE FLOOR. 1/2" OR LARGER FOAM CORE PADDING FOR VIBRATION PROTECTION. INSTALL BELOW LINK SEAL. FINISH WITH CMU CUT AT 45'. MORTAR TO TOP OF WALL. FULLY GROUTED CMU BLOCK WALL #5 VERT TYP EACH END UNDISTURBED NATIVE EARTH REMOTE FILL STATIO BLAN A MII INTERIC PROPOSED 60C ENGINE GENERA DUAL WALL SUB —BASE FUEL TANK. SEE SPECIFICATIONS . •a ' . FOR DETAILS. +• :. ' 3" DIA, GEOFLEX D DOUBLE ' WALL FUEL PIPING OR EQUAL. INSTALL FROM REMOTE FUEL TANK TO STATIONARY ENGINE #4 @ 12" O.C., EW, TOP AND BOTTOM 3" TYP NATIVE OR STRUCTURAL FILL �- COMPACTED TO 97% STANDARD MIN 4" DEPTH OF CRUSHED SURFACING COMPACTED TO 97% STANDARD PROCTOR. N SECTION PROPOSED ALUMINIZED STEEL RAIN CAP WITH STAINLESS STEEL MOUNTING .A :NT 'IPE D TO FROM TINTS. JLESS ST BE EARY EXPIRES 3 19/2008 SIGNED: 07128106 EXPIRES 5 14 2008 SIGNED: 071281106 0 N r Z O Uj W CA fmn4w ZW J � W (0PLO U V ~z � Va w W J � W W -�H2 ENGINv EKING. INC. http://www.rh2.com mailbox0rh2.com 1.800.720.8052 BELLINGHAM OFFICE 360.676.0836 454 West Horton Road BOTHELL OFFICE 425.951.5400 12100 NE 195th Street, Suite 100 EAST WENATCHEE OFFIC 509.886.2900 300 Simon Street, Suite 5 PORT ORCHARD OFFICE 360.876.7960 600 Kitsap Street, Suite 101 REVISED TO CONFORM FOR FUEL LINES. PROVIDE LINK SEAL TO CONSTRUCTION RECORDS ENGINEER: DAB E09 AT GENERATOR BUILDING FLOOR PENETRATION. SEE DETAIL THIS SHEET.��� RENEWED: MM ��� �� 11 /01 /2007 DATE: NOV 2, 2007 1EEr Na. STATIONARY ENGINE GENERATOR OBLIQUE 32 NOT TO SCALE RH2 ENGINEERING INC. DATE "CLIENT: REN REVISED TO CONFORM TO CONSTRUCTION RECORDS :MR MLM 11/01/07 joB No.: 105-079 1 33 NO. REVISION BY REVIEW DATE E'' ENAME: GEN—D—EO9 NOT TO SCALE 1" - 1'-0" Az)' w --'? 3`l3?