POLE SCHEDULE
LUM.
POLE NO.
WH1TWQALPL NE
STATION
POLE
OFFSET
MOUNTING
HEIGHT
ARM
LENGTH
CIRCUIT
WATTAGE
PHOTOMETRICS
COMMENTS
CITY OF RENTON
LUMINAIRE ID #
1
BREMERTON AVENUE NE
23+27.0
23.0' LT
25'
6
1
100W
FLAT LENS
M-C-111
3932B
2
BREMERTON AVENUE NE
21 +29.5
23.0' LT
25'
6'
1
100W
FLAT LENS
M-C-Ill
3934B
3
BREMERTON AVENUE NE
19+97.5
23.0' LT
25'
6'
1
100W
FLAT LENS
M-C-111
39368
4
NE 2ND LN
10+ 19.0
22.5' LT
25'
6'
1
1 OOW
FLAT LENS
M-C-Ili
3938B
5
NE 2ND LN
1 1 +91.0
22.5' RT
25'
6'
1
l 0QW
FLAT LENS
M-C-Ill
3933B
6
NE 2ND LN
13+99.5
22.5' LT
25'
6'
2
100W
FLAT LENS
M-C-111
3940E
7
WHITMAN PL NE
15+70.5
22.5' RT
25'
6'
2
100W
FLAT LENS
M-C-111
INSTALL PHOTOCELL
3939B
8
WHITMAN PL NE
17+53.0
22.5' LT
25'
6'
2
1 ooW
FLAT LENS
M-C-Ill
3942B
9
NE 2ND CT
18+53.5
22.5' RT
25'
6'
2
100W
F IA TCLENS
39448
10
NE 2ND CT
20+ 1 1.0
22.5' LT
25'
6'
2
100W
FLAT LENS
M-C-III
3943B
11
NE 2ND CT
21 +24.5
23.5' RT
25'
6'
2
l 00W
FLAT LENS
M-C-Ill
3946B
12
NE 2ND CT
22+83.0
22.5' RT
25'
6'
1
l ooW
FLAT LENS
M-C-Ill
3948B
13
ANACORTES PL NE
30+26.0
23.0' LT
25'
6'
2
l00W
FLAT LENS
M-C-Ill
39509
14
ANACORTES PL NE
31 +57.5
22.5' RT
25'
6'
2
1 ooW
FLAT LENS
M-C-Ill
3949B
15
ANACORTES PL NE
33+ 15.5
22.5' LT
25'
6'
2
1 ooW
FLAT LENS
M-C-/ll
39528
WIRING DIAGRAM
v �vvL CABINET ID = 0091
GENERAL NOTES
1. ALL WORK MATERIALS SHALL BE IN CONFORMANCE WITH THE
STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON UTILITY
DEPARTMENT AND THE LATEST EDITION OF THE WSDOT%APWA
STANDARDS AND SPECIFICATIONS. A SET OF APPROVED PLANS SHALL
BE KEPT ON -SITE AT ALL TIMES DURING CONSTRUCTION.
2. THE HOURS OF WORK IN THE STREET RIGHT-OF-WAY SHALL BE
LIMITED TO 8:30 AM TO 3:30 P.M. ON WEEKDAYS UNLESS OTHERWISE
APPROVED IN WRITING BY THE DEPARTMENT OF PUBLIC WORKS AT
235-2635. ALL STREET CLOSURES, PARTIAL OR FULL, SHALL BE
APPROVED BY THE DEPARTMENT OF PUBLIC WORKS 24 HOURS IN
ADVANCE. THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911
SHALL BE NOTIFIED 24 HOURS IN ADVANCE.
3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE
AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY
THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR
DISTURBANCE. FOR UTILITY LOCATE CALL 48-HOUR LOCATORS,
1-800-424-5555.
4. A PRECONSTRUCTION CONFERENCE AND A 24 HOUR NOTICE SHALL BE
REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. IT SHALL BE
THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY
PERMITS PRIOR TO STARTING CONSTRUCTION. (INSPECTION WILL BE
ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON). IT
SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE
UTILITY DEPARTMENT 24 HOURS IN ADVANCE OF BACKFILLING ALL
CONSTRUCTION.
5. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND
SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND
OTHERS ON THE CONSTRUCTION SITE.
6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN
STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO ANY
CONSTRUCTION.
7. PLANS APPROVED BY THE DIRECTOR OF PUBLIC WORKS SHALL TAKE
PRECEDENCE OVER ALL OTHER PLANS.
8. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE
WHENEVER CONSTRUCTION IS IN PROGRESS.
9. ALL UTILITY TRENCHES SHALL BE BACKFILLED AND COMPACTED TO
955Y. MAXIMUM DRY DENSITY MODIFIED PROCTOR.
10. THE CONTRACTOR SHALL PROVIDE MATERIALS SUBMITTALS AND POLE
SHOP DRAWINGS TO THE CITY OF RENTON FOR APPROVAL AT THE
EARLIEST POSSIBLE DATE.
CONSTRUCTION NOTES
INSTALL COBRA HEAD LUMINAIRE ON LUMINAIRE POLE PER THE POLE SCHEDULE THIS SHEET, AND
CITY OF RENTON STANDARD PLANS, SHEETS IL5 AND IL6. TOP OF FOUNDATION SHALL BE FLUSH
WITH TOP OF SIDEWALK. THE POLE SHALL MEET ALL REQUIREMENTS OF A CITY OF RENTON
STANDARD ALUMINUM DAVIT POLE.
(1 EXTEND CONDUIT TO PROJECT LIMIT AND INSTALL JUNCTION BOX.
OINSTALL CITY OF RENTON STANDARD SERVICE CABINET, PER CITY OF RENTON STANDARDS (SEE
SHEET IL5). CABINET ID #0091.
1201240V POWER SOURCE TO BE PROVIDED BY PUGET SOUND ENERGY. TRENCH AND PROVIDE
CONDUIT AND CONDUCTORS TO PUGET SOUND ENERGY POWER SOURCE. LOCATION SHOWN IS
APPROXIMATE, ACTUAL POWER SOURCE LOCATION MAY VARY. THE CONTRACTOR SHALL COORDINATE
POWER SOURCE LOCATION WITH PSE.
U TYPE 2 JUNCTION BOX. rqb 324,604
TRANSPORTATION ENGINEERING NORTHWEST, LLC
PO BOX 65254
SEATTLE, WA 98155
(425) 806 9236
(360) 668 1133