Loading...
HomeMy WebLinkAboutWTR2703246.3REVISIONS 00 Q M M M 0 o o M CD o U Z mW Q w a a _ co Z 0 VJ R co J Q Cn W Q W J WZ 1 Q W W I.- 0 C)L - N O LL Z 00O 0 F- � Z Q .a LLi 1 V � \a �C C C �E , E .� �I oT - HIV C o � a-C.D LL1 r = J 'UZ Z x azo v O z `'' O w - U Z C) Q � o ate¢ a N LOLO U U J Q Q J Q U' a 0 o W 0 w > 0 3 s > v Q' v) a W 0- V) 0 V Q � J d Li J �- Q CV H I Q LQ Q O in 0 I- Z LLI O C) Z O F- Z LLJ (ifO_ LL Ln O 5 LLI 0' U Of LLI De 0 W 0 w cr 2" OPEN PATTERN, RETURN BEND - 180• 2" GALVANIZED IRON PIPE FIELD LOCATE 2" 90' ELBOW CUT OPENING AS REQUIRED, AFTER INSTALLATION, GROUT AROUND PIPE. 2" BEEHIVE STRAINER 2" UNION SHORT NIPPLE' 2" CLOSE NIPPLE 2"x2"x2" TEE-\ 2" UNION 17"x30" PLASTIC METER BOX EQUAL TO MID STATES PLASTIC, BCF SERIES 1730-18 WITH 2" THICK DUCTILE 1 IRON DIAMOND PLATE. 18"x31" MSCBC 1730R 2" BRONZE GATE VALVE, SCREWED EQUAL TO RED -WHITE VALVE CORP. FIG NO. 280 2" RESILIENT SEAT GATE VALVE 2" 90• BEND WITH CLOSE NIPPL WITH THREADED ENDS BETWEEN BEND AND TEE 2-2" BRASS 90' BENDS WITH 2" GALVANIZED IRON PIPE TO FIT CLOSE NIPPLE BETWEEN BENDS apO� CLOSE NIPPLE ° 0 00 0 0 00 ° o°O o 12 I MIN. / �°p °°� oo°O o0 o Qo°o o /- 2" CORPORATION STOP 90' BEND, °o I.P. THREAD TO COPPER, EQUAL / 2" TYPE K SOFT 21 TO FORD FB 500. 2" GALVANIZED IRON J COPPER TUBING TO FIT PIPE 18" LONG DOUDLE STRAP SERVICE CLAMP WITH 2" 2" CAP WITH 1/8" IPS TAP TO FIT, EQUAL TO MUELLER CO. HOLE FOR DRAIN, 2" 90' ELBOW DOUDLE STRAP SERVICE CLAMP WITH 2" IPS TAP TO FIT, EQUAL TO MUELLER CO. WASHED GRAVEL, PASSING 1-1/2" AND AIR AND VACUUM VALVE 2" ASSEMBLY RETAINED ON 1/4" MESH FOR DRAIN APCO NO. 1452C OR EQUAL. NOTES AIR AND VACUUM RELEASE VALVE ASSEMBLY SHALL BE INSTALLED AT HIGHEST POINT OF LINE. IF HIGH POINT FALLS IN A LOCATION WHERE ASSEMBLY CANNOT BE INSTALLED, PROVIDE ADDITIONAL DEPTH OF LINE TO CREATE A HIGH POINT AT A LOCATION WHERE ASSEMBLY CAN BE INSTALLED. LOCATE AIR VACUUM METER BOX OUTSIDE OF TRAFFIC AREAS, IN PLAN77NG STRIPS, BEHIND CURB AND SIDEWALK. Y ADOPTED CITY OF RENTON N Standard plans LST DATE: 04/04 2" AIR & VACUUM RELEASE VALVE ASSEMBLY DWG. NAME : BR51 SP PAGE : 8095 CONCRETE BLOCKING SIZING PROCEDURE A. GENERAL The amount of concrete required to anchor horizontal bends, tees, and dead ends depends on the strength of the soil. The methods of placing concrete to keep the joint accessible is shown in Figure 1. The area in square feet of concrete which must bear against the side of the trench is found by dividing the thrust in pounds shown in Table 1 by the safe bearing load of the soil as shown in Table 2. B. 1. The sizing procedure is for horizontal or downward thrust only. 2. Height of the thrust block must be equal to or less than 1/2 the depth from the ground surface to the block base. 3. The thrust block bearing face is approximately rectangular. 4. The concrete blocking shall be as per APWA SYMgOLScification 74-2.14. C. d = Outside Diameter of Pipe in Feet T = Thrust in Pounds at the Fitting (Table 1) SBL = Safe Bearing Load in Pounds/Sq. Ft. (Table 2) h = Depth of Trench in Feet W = Width of Trench in Feet A = Area of Concrete which must bear against the Side of the Trench in Sq. Ft. Hm = Maximum Height of the Thrust Block in feet Dc = Depth of the Concrete Thrust Block to Bearing Surface in Feet Lm Maximum Length of the Thrust Block in Feet GROUND SUFACE h `fF r d ' HMI 2 + BLOCK BASE m �Dc W D. CALCULATION EQUATIONS 1. Area of Concrete (A) = Thrust (In Pounds = T Safe Bearing Load (In Pounds/Sq. Ft.) SBL 2. Maximum Height of Thrust Block (Hm) Depth of Trench in Feet _ h 2 - 2 Width of Trench in Feet) - 3. Depth of Concrete Thrust Block = Outside Diameter of Pipe in Feet) _ W-d 2 2 Area 4. Maximum Length of Thrust Block (Lm) = _ Maximum Concrete q mum Height HM 5. Required Amount of Concrete (Cu. Yd.) _ (Height x Depth x Length) x 0,03704 (Hm x Lm x Dc) x 0.03704 E. EXAMPLE 1. Problem: Calculation of the amount of concrete required to block a 90' bend in an 8" C.I. water main; the normal operating pressure in the pipe will be 65 psi and the soil condition in the area indicates sand and gravel. 2. Solution: - Maximum testing pressure (See Table 1) = 300 ppsi. = 0,75 ft. - Outside diameter of 8 pipe = 9.05 in. = 9.05/12 - Go to Table 1: The testing pressure of 300 psi, we see that the thrust on a 90' bend is 21,360 pounds. SEC. 15, TWP. 23 N., RNG. 5 E., W.M. - Go to Table 2: Table 2 gives the safe bearing load for sand and gravel: 3,000 lbs./sq, ft, - Go to Figure 1: figure 1 indicates the position of the concrete for blocking the 90' bend. - Go to the specifications of the project and find depth of trench h = 4 feet - Width of trench = 3 feet With the above assembled information, we proceed to the final calculations: Thrust 21,360 - Area of Concrete (A) _ - _ = 7.12 sq ft. Safe Bearing Load 3,000 - Maximum Height of Thrust Block (Hm) = Depth of Trench in Feet 2 = h 4 = 2.0 ft. 2 2 - Depth of Concrete Thrust Block (Dc) Width of Trench in Feet (W) - Outside Diameter of Pipe (d) v 2 = 3 - 0.75 = 1.13 ft. 2 - Maximum Length of Thrust Block (Lm) = Area of Concrete Height of Concrete ® A 7,12 Hm = 2.0.0 = 3.56 ft. - Required Amount of Concrete = (Height x Depth x Length) x 0,03704 = (Hm x Lm x Dc) x 0.03704 - (2.0 x 3.56 x 1.13) x 0.03704 = 0.30 cu. yd. TABLE 1 Size Pressure PSI Thrust at Fittings in Pounds Tees 90, 45` 22-1 /2 11-1 /4' Dead Ends Bend Bend Bend Bend 3" 300 2,120 3,000 1,630 830 430 4" 300 3,780 5,370 2,910 1,470 750 6" 300 8,500 12,000 6,510 3,320 1,700 8" 300 15,100 21,360 11,550 5,880 3,020 10" 275 21,620 30,570 16,540 8,430 4,330 12" 250 33,930 48,000 25,950 13,260 6,780 14" 250 46,200 65,370 35,340 18,030 9,240 16" 225 45,250 64,000 34,620 17,650 9,050 18" 200 50,900 72,000 38,940 19,860 10,180 20" 200 62,840 88,900 48,080 24,520 12,560 24" 200 90,480 127,980 69,200 35,320 18.100 30" 200 141,370 199,960 108,150 55,140 28,280 36"1 200 1203,580 1287,9501155,7401 79,400 140,720 TABLE 2 Safe Bearing Loads in Lb./Sp. Ft. The safe bearing loads given in the following table are for horizontal thrusts when the depth of cover over the pipe exceeds 2 feet. Safe Bearing Load .0 L Lb. per ag, Ft. *Muck, peat, etc. 0 Soft Cloy 1,000 Sand 2,000 Sand and Gravel 3,000 Sand and Gravel Cemented with Clay 4,000 Hard Shale 10,000 *In muck or peat, all thrusts shall be restrained by piles or tie rods to solid foundations or by removal of muck or peat and replacement with ballast of sufficient stability to resist thrusts, TEE 22-1/20 0 45BEND FIGURE 1 90 BEND NOTE: FOR CONVEX VERTICAL BENDS BLOCKING SEE APWA STANDARD PLAN NO. 73. *N1 ADOPTED CITY OF RENTON Standard plans LST DATE: 12/96 CONCRETE BLOCKING SIZING PROCEDURE DWG. NAME : BR26 SP PAGE : B085 FIRE HYDRANT SHALL BE COREY-TYPE EQUAL TO IOWA F-5110 OR COMPRESSION TYPE SUCH AS CLOW MEDALLION; M & H 929, MUELLER SUPER CENTURION 200, AND WATEROUS PACER WITH 6" MECHANICAL JOINT INLET WITH LUGS, 5-1/4" MAIN VALVE OPENING, TWO 2-1/2" HOSE CONNECTIONS NATIONAL STANDARD THREADS. 4" PUMPER CONNECTION CITY OF SEATTLE THREADS WITH A STORZ ADAPTOR, 4.875" SEATTLE THREAD X 5" STORZ, ATTACHED WITH 1/8" STAINLESS STEEL CABLE. 1-1/4" PENTAGON OPERATING NUT. FIRE HYDRANT TO BE PAINTED WITH TWO COATS OF PAINT. KELLY-MOORS/PRESERVATIVE PAINT No, 5780-563 DIM ACRYLIC GLOSS, SAFETY YELLOW OR APPROVED EQUAL, PUMPER CONNECTION TO FACE ROADWAY OR AS DIRECTED BY RENTON FIRE DEPARTMENT, FIRE HYDRANT EXTENSION TO BE USED IF REQUIRED. ----18" TO 20" BEHIND BACK OF CURB OR 12" BEHIND BACK OF SIDEWALK THAT IS ADJACENT TO CURB TWO-PIECE CAST IRON VALVE BOX WITH LUG TYPE COVER. EQUAL TO OLYMPIC FOUNDRY CO. STANDARD 8" TOP SECTION 4.875" x 5" STORZ WITH REGULAR BASE SEC77ON LENGTH TO FIT. VALVE NUT o EXTENSION AS REQUIRED (SEE DWG BR46 / PAGE 8090). MAX 4" RAISED PAVEMENT MARKER TYPE 88 MIN 2" A8 STIMSONITE TWO-WAY BLUE. 4CONCRETE 8URYN c BLOCKING U \�MAIN LINE TEE. WITH 6" FLANGE SIDE OUTLET. '6" GATE VALVE (FL X MJ) AWWA C-509, RESILIENT SEAT 6" DUCTILE IRON PIPE, CLASS 52 CEMENT LINED, LENGTH TO FIT 16" x 8" x 4" 2-3/4" COR-TENSTEEL TIE RODS, SEE STD DETAIL FOR TIE RODS. MININUM CONCRETE BLOCK UNDER HYDRANT 1/2 YARD WASHED DRAIN ROCK (3-TO 3/8") MIN. 1' ABOVE BOOT FLANGE. PLACE 8 MIL POLYETHYLENE FILM AROUND TOP AND SIDES OF GRAVEL. FIRE HYDRANT ASSEMBLY LEVEL ALL GROUND MIN 3' RADIUS 1 `\ 4.875" x 5" 6 1 STORZ ONE MAN ROCK- 1 6 �I LEVEL ALL GROUND MIN �3' RADIUS o, FILL CUT HYDRANT LOCATION IN CUT OR FILL " • Y ADOPTED + > CITY OF RENTON ow,N T Standard plans LST DATE: 04104 FIRE HYDRANT ASSEMBLY DETAIL DWG. NAME : BR24 SP PAGE : B102 N , • ,4S,w BU/L;r %AdP324b V i CHECKED FOR COMPLIANCE TO CITY STANDARDS Date Date Date RECOMMENDED FOR APPROVAL BY. BY: a F.� L 6 L 3�05 EXPIRES: MAY 6, 2007 LO 00 W0) 0 T 00 \ / \ Q 0000 00 pI I TWO Lo 70N W N U5Z 0200kofU W III 1< N W < Iq 11 � � LL a- hn U wd 0 cct .� ^ WJ C) W Q w •� U a 3 Z 0 0W WrnIt N m d0' W 1 (10 D N N V♦ � LL N X O O Z J a° D W J 00 N W ON C) - �2111� J T- WT 12; WtnQQ 0 MNW= R LL Jrn(1)IL PROJECT NO.: 02054 DRAWN BY: AA/JGC ISSUE DATE: 03-07-05 SHEET REV.; i 06-13-05 WATER DETAILS 02054DT05C33A C33A W?*-:p-I&uJ6 . �I, nol 43 -1 W SCMWED OCT 2 8 ZOOS