HomeMy WebLinkAboutWTR2703246.3REVISIONS
00
Q
M
M
M
0
o
o
M
CD
o
U
Z
mW
Q
w
a
a
_
co
Z
0
VJ
R
co
J
Q
Cn
W
Q
W
J
WZ
1
Q
W
W
I.-
0
C)L -
N O
LL
Z
00O
0
F-
�
Z
Q
.a LLi
1
V
�
\a
�C
C
C
�E
, E
.�
�I
oT -
HIV
C
o �
a-C.D
LL1
r
= J
'UZ
Z
x
azo
v
O
z
`'' O
w
-
U
Z
C)
Q
� o
ate¢
a
N
LOLO
U
U
J
Q
Q
J
Q
U'
a
0
o
W
0
w
>
0
3
s
>
v
Q'
v)
a
W
0-
V)
0
V
Q
�
J
d
Li
J
�-
Q
CV
H
I
Q
LQ
Q
O
in
0
I-
Z
LLI
O
C)
Z
O
F-
Z
LLJ (ifO_
LL Ln
O 5
LLI
0'
U
Of
LLI
De
0
W
0
w
cr
2" OPEN PATTERN, RETURN BEND - 180•
2" GALVANIZED IRON PIPE FIELD LOCATE
2" 90' ELBOW
CUT OPENING AS REQUIRED, AFTER INSTALLATION,
GROUT AROUND PIPE.
2" BEEHIVE STRAINER 2" UNION
SHORT NIPPLE'
2" CLOSE NIPPLE
2"x2"x2" TEE-\ 2" UNION
17"x30" PLASTIC METER BOX EQUAL TO MID STATES
PLASTIC, BCF SERIES 1730-18 WITH 2" THICK DUCTILE
1 IRON DIAMOND PLATE. 18"x31" MSCBC 1730R
2" BRONZE GATE VALVE, SCREWED EQUAL TO
RED -WHITE VALVE CORP. FIG NO. 280
2" RESILIENT SEAT GATE VALVE
2" 90• BEND WITH CLOSE NIPPL WITH THREADED ENDS
BETWEEN BEND AND TEE 2-2" BRASS 90' BENDS WITH
2" GALVANIZED IRON PIPE TO FIT CLOSE NIPPLE BETWEEN BENDS
apO� CLOSE NIPPLE
° 0 00 0 0 00 ° o°O o
12 I MIN. / �°p °°� oo°O o0 o Qo°o o /- 2" CORPORATION STOP 90' BEND,
°o I.P. THREAD TO COPPER, EQUAL
/ 2" TYPE K SOFT 21 TO FORD FB 500.
2" GALVANIZED IRON J COPPER TUBING TO FIT
PIPE 18" LONG DOUDLE STRAP SERVICE CLAMP WITH 2"
2" CAP WITH 1/8" IPS TAP TO FIT, EQUAL TO MUELLER CO.
HOLE FOR DRAIN, 2" 90' ELBOW DOUDLE STRAP SERVICE CLAMP WITH 2"
IPS TAP TO FIT, EQUAL TO MUELLER CO.
WASHED GRAVEL, PASSING 1-1/2" AND AIR AND VACUUM VALVE 2" ASSEMBLY
RETAINED ON 1/4" MESH FOR DRAIN APCO NO. 1452C OR EQUAL.
NOTES
AIR AND VACUUM RELEASE VALVE ASSEMBLY SHALL BE INSTALLED AT HIGHEST POINT OF
LINE. IF HIGH POINT FALLS IN A LOCATION WHERE ASSEMBLY CANNOT BE INSTALLED, PROVIDE
ADDITIONAL DEPTH OF LINE TO CREATE A HIGH POINT AT A LOCATION WHERE ASSEMBLY CAN
BE INSTALLED.
LOCATE AIR VACUUM METER BOX OUTSIDE OF TRAFFIC AREAS, IN PLAN77NG STRIPS, BEHIND
CURB AND SIDEWALK.
Y ADOPTED
CITY OF RENTON
N Standard plans
LST DATE: 04/04
2" AIR & VACUUM RELEASE
VALVE ASSEMBLY
DWG. NAME : BR51 SP PAGE : 8095
CONCRETE BLOCKING SIZING PROCEDURE
A. GENERAL
The amount of concrete required to anchor horizontal
bends, tees, and dead ends depends on the strength
of the soil. The methods of placing concrete to keep
the joint accessible is shown in Figure 1. The area
in square feet of concrete which must bear against
the side of the trench is found by dividing the
thrust in pounds shown in Table 1 by the safe
bearing load of the soil as shown in Table 2.
B.
1. The sizing procedure is for horizontal or
downward thrust only.
2. Height of the thrust block must be equal
to or less than 1/2 the depth from the ground
surface to the block base.
3. The thrust block bearing face is approximately
rectangular.
4. The concrete blocking shall be as per APWA
SYMgOLScification 74-2.14.
C.
d = Outside Diameter of Pipe in Feet
T = Thrust in Pounds at the Fitting (Table 1)
SBL = Safe Bearing Load in Pounds/Sq. Ft. (Table 2)
h = Depth of Trench in Feet
W = Width of Trench in Feet
A = Area of Concrete which must bear against the
Side of the Trench in Sq. Ft.
Hm = Maximum Height of the Thrust Block in feet
Dc = Depth of the Concrete Thrust Block
to Bearing Surface in Feet
Lm Maximum Length of the Thrust Block in Feet
GROUND SUFACE
h `fF r
d '
HMI 2 +
BLOCK BASE m
�Dc
W
D. CALCULATION EQUATIONS
1. Area of Concrete (A) = Thrust (In Pounds = T
Safe Bearing Load (In Pounds/Sq. Ft.) SBL
2. Maximum Height of Thrust Block (Hm) Depth of Trench in Feet _ h
2 - 2
Width of Trench in Feet) -
3. Depth of Concrete Thrust Block = Outside Diameter of Pipe in Feet) _ W-d
2 2
Area
4. Maximum Length of Thrust Block (Lm) = _
Maximum
Concrete q
mum Height HM
5. Required Amount of Concrete (Cu. Yd.) _ (Height x Depth x Length) x 0,03704
(Hm x Lm x Dc) x 0.03704
E. EXAMPLE
1. Problem:
Calculation of the amount of concrete required to block a 90' bend in an 8"
C.I. water main; the normal operating pressure in the pipe will be 65 psi and the soil
condition in the area indicates sand and gravel.
2. Solution:
- Maximum testing pressure (See Table 1) = 300 ppsi. = 0,75 ft.
- Outside diameter of 8 pipe = 9.05 in. = 9.05/12
- Go to Table 1: The testing pressure of 300 psi, we see
that the thrust on a 90' bend is 21,360 pounds.
SEC. 15, TWP. 23 N., RNG. 5 E., W.M.
- Go to Table 2: Table 2 gives the safe bearing load for
sand and gravel: 3,000 lbs./sq, ft,
- Go to Figure 1: figure 1 indicates the position
of the concrete for blocking the 90' bend.
- Go to the specifications of the project and find
depth of trench h = 4 feet
- Width of trench = 3 feet
With the above assembled information,
we proceed to the final calculations:
Thrust 21,360
- Area of Concrete (A) _ - _ = 7.12 sq ft.
Safe Bearing Load 3,000
- Maximum Height of Thrust Block (Hm) = Depth of Trench in Feet
2
= h 4 = 2.0 ft.
2 2
- Depth of Concrete Thrust Block (Dc)
Width of Trench in Feet (W) - Outside Diameter of Pipe (d)
v 2
= 3 - 0.75 = 1.13 ft.
2
- Maximum Length of Thrust Block (Lm) = Area of Concrete
Height of Concrete
® A 7,12
Hm = 2.0.0 = 3.56 ft.
- Required Amount of Concrete = (Height x Depth x Length) x 0,03704
= (Hm x Lm x Dc) x 0.03704
- (2.0 x 3.56 x 1.13) x 0.03704
= 0.30 cu. yd.
TABLE 1
Size
Pressure PSI
Thrust at Fittings in Pounds
Tees
90,
45`
22-1 /2
11-1 /4'
Dead Ends
Bend
Bend
Bend
Bend
3"
300
2,120
3,000
1,630
830
430
4"
300
3,780
5,370
2,910
1,470
750
6"
300
8,500
12,000
6,510
3,320
1,700
8"
300
15,100
21,360
11,550
5,880
3,020
10"
275
21,620
30,570
16,540
8,430
4,330
12"
250
33,930
48,000
25,950
13,260
6,780
14"
250
46,200
65,370
35,340
18,030
9,240
16"
225
45,250
64,000
34,620
17,650
9,050
18"
200
50,900
72,000
38,940
19,860
10,180
20"
200
62,840
88,900
48,080
24,520
12,560
24"
200
90,480
127,980
69,200
35,320
18.100
30"
200
141,370
199,960
108,150
55,140
28,280
36"1
200
1203,580
1287,9501155,7401
79,400
140,720
TABLE 2
Safe Bearing Loads in Lb./Sp. Ft.
The safe bearing loads given in the following table are for
horizontal thrusts when the depth of cover over the pipe
exceeds 2 feet.
Safe Bearing Load
.0 L Lb. per ag, Ft.
*Muck, peat, etc. 0
Soft Cloy 1,000
Sand 2,000
Sand and Gravel 3,000
Sand and Gravel Cemented with Clay 4,000
Hard Shale 10,000
*In muck or peat, all thrusts shall be restrained by piles or
tie rods to solid foundations or by removal of muck
or peat and replacement with ballast of sufficient
stability to resist thrusts,
TEE
22-1/20
0
45BEND
FIGURE 1
90 BEND
NOTE: FOR CONVEX VERTICAL BENDS BLOCKING
SEE APWA STANDARD PLAN NO. 73.
*N1
ADOPTED
CITY OF RENTON
Standard plans
LST DATE: 12/96
CONCRETE BLOCKING SIZING PROCEDURE
DWG. NAME : BR26 SP PAGE : B085
FIRE HYDRANT SHALL BE COREY-TYPE EQUAL TO IOWA F-5110 OR
COMPRESSION TYPE SUCH AS CLOW MEDALLION; M & H 929, MUELLER
SUPER CENTURION 200, AND WATEROUS PACER WITH 6" MECHANICAL
JOINT INLET WITH LUGS, 5-1/4" MAIN VALVE OPENING, TWO 2-1/2"
HOSE CONNECTIONS NATIONAL STANDARD THREADS. 4" PUMPER
CONNECTION CITY OF SEATTLE THREADS WITH A STORZ ADAPTOR,
4.875" SEATTLE THREAD X 5" STORZ, ATTACHED WITH 1/8" STAINLESS
STEEL CABLE. 1-1/4" PENTAGON OPERATING NUT. FIRE HYDRANT TO
BE PAINTED WITH TWO COATS OF PAINT. KELLY-MOORS/PRESERVATIVE
PAINT No, 5780-563 DIM ACRYLIC GLOSS, SAFETY YELLOW OR
APPROVED EQUAL, PUMPER CONNECTION TO FACE ROADWAY OR AS
DIRECTED BY RENTON FIRE DEPARTMENT, FIRE HYDRANT EXTENSION TO
BE USED IF REQUIRED.
----18" TO 20" BEHIND BACK OF
CURB OR 12" BEHIND BACK OF
SIDEWALK THAT IS ADJACENT TO
CURB
TWO-PIECE CAST IRON VALVE BOX WITH LUG TYPE COVER.
EQUAL TO OLYMPIC FOUNDRY CO. STANDARD 8" TOP SECTION
4.875" x 5" STORZ WITH REGULAR BASE SEC77ON LENGTH TO FIT. VALVE NUT
o EXTENSION AS REQUIRED (SEE DWG BR46 / PAGE 8090).
MAX 4" RAISED PAVEMENT MARKER TYPE 88
MIN 2" A8 STIMSONITE TWO-WAY BLUE.
4CONCRETE
8URYN c BLOCKING
U
\�MAIN LINE TEE. WITH 6" FLANGE SIDE OUTLET.
'6" GATE VALVE (FL X MJ) AWWA C-509, RESILIENT SEAT
6" DUCTILE IRON PIPE, CLASS 52 CEMENT LINED, LENGTH TO FIT
16" x 8" x 4" 2-3/4" COR-TENSTEEL TIE RODS, SEE STD DETAIL FOR TIE RODS.
MININUM CONCRETE
BLOCK UNDER
HYDRANT 1/2 YARD WASHED DRAIN ROCK (3-TO 3/8") MIN.
1' ABOVE BOOT FLANGE. PLACE 8 MIL
POLYETHYLENE FILM AROUND TOP AND SIDES OF
GRAVEL.
FIRE HYDRANT ASSEMBLY
LEVEL ALL GROUND
MIN 3' RADIUS
1 `\ 4.875" x 5"
6 1 STORZ
ONE MAN ROCK-
1
6 �I
LEVEL ALL GROUND MIN
�3' RADIUS
o,
FILL
CUT
HYDRANT LOCATION IN CUT OR FILL " •
Y ADOPTED
+ > CITY OF RENTON
ow,N T Standard plans
LST DATE: 04104
FIRE HYDRANT ASSEMBLY DETAIL
DWG. NAME : BR24 SP PAGE : B102
N , •
,4S,w BU/L;r
%AdP324b V i
CHECKED FOR COMPLIANCE
TO CITY STANDARDS
Date
Date
Date
RECOMMENDED
FOR APPROVAL
BY.
BY:
a
F.� L 6 L 3�05
EXPIRES: MAY 6, 2007
LO
00
W0) 0
T 00
\
/ \
Q 0000 00
pI I TWO
Lo
70N
W N
U5Z
0200kofU
W III 1< N
W
<
Iq 11 � � LL
a-
hn U
wd
0
cct
.�
^ WJ
C)
W
Q
w
•�
U
a
3
Z
0
0W
WrnIt
N
m d0'
W 1
(10
D N
N
V♦ �
LL
N
X
O
O
Z J a°
D W J 00 N
W ON
C)
- �2111�
J T-
WT 12; WtnQQ
0 MNW=
R LL Jrn(1)IL
PROJECT NO.:
02054
DRAWN BY:
AA/JGC
ISSUE DATE:
03-07-05
SHEET REV.;
i
06-13-05
WATER
DETAILS
02054DT05C33A
C33A
W?*-:p-I&uJ6
. �I, nol
43 -1 W SCMWED OCT 2 8 ZOOS