HomeMy WebLinkAboutWTR2703250.1SURFACE WATER DRAINAGE NOTES & SPECIFICATIONS
1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING MUST BE HELD WITH THE CITY OF
RENTON PLAN REVIEWER.
2. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE "1994 STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL
CONSTRUCTION" PREPARED BY W.S.D.O.T., AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA), AS AMENDED BY THE CITY OF
RENTON DEPARTMENT OF PUBLIC WORKS.
3. NOT USED.
4. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS.
5. DATUM SHALL BE NAVD 88. UNLESS OTHERWISE APPROVED BY CITY OF RENTON DEPARTMENT OF PUBLIC WORKS. REFERENCE
BENCHMARK AND ELEVATION ARE NOTED ON THE PLANS.
6. ALL SEDIMENTATION/EROSION FACILITIES MUST BE IN OPERATION PRIOR TO CLEARING AND BUILDING CONSTRUCTION, AND THEY MUST
BE SATISFACTORILY MAINTAINED UNTIL CONSTRUCTION IS COMPLETED AND THE POTENTIAL FOR ON -SITE EROSION HAS PASSED.
7. NOT USED.
8. GRASS SEED MAY BE APPLIED BY HYDROSEEDING. THE GRASS SEED MIXTURE, OTHER THAN CITY OF RENTON APPROVED STANDARD
MIXES, SHALL BE SUBMITTED BY A LANDSCAPE ARCHITECT AND APPROVED BY THE DEPARTMENT OF PUBLIC WORKS, SURFACE WATER
UTILITY.
9. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH SECTION 7-02.3(1)
OF THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE
NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL AS WELL AS PLACEMENT AND COMPACTION
OF REQUIRED BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY
DENSE UNYIELDING BASE. ALL PIPE BEDDING SHALL BE APWA CLASS "C', WITH THE EXCEPTION OF PVC PIPE. ALL TRENCH BACKFILL
SHALL BE COMPACTED TO MINIMUM 95% FOR PAVEMENT AND STRUCTURAL FILL AND 90% OTHERWISE PER ASTM D-1557-70. PEA
GRAVEL BEDDING SHALL BE 6" OVER AND UNDER P.V.C. PIPE.
10. NOT USED.
11. STRUCTURES SHALL NOT BE PERMITTED WITHIN 10 FEET OF THE SPRING LINE OF ANY STORM DRAINAGE PIPE, OR 15 FEET FROM
THE TOP OF ANY CHANNEL BANK.
12. NOT USED.
13. OPEN CUT ROAD CROSSINGS THROUGH EXISTING PUBLIC RIGHT OF WAY WILL NOT BE ALLOWED UNLESS SPECIFICALLY APPROVED BY
THE CITY OF RENTON ADMINISTRATOR, DEPARTMENT OF PLANNING/BUILDING/PUBLIC WORKS.
14. ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A
DEPTH OF I FOOT AND MUST MEET THE FOLLOWING SPECIFICATIONS: 4"-8"/407.-707. PASSING; 2"-4" ROCK/30%-40% PASSING; AND
-2- ROCK/10%-20% PASSING.
16. ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMIT BY THE CITY OF RENTON DOES NOT RELIEVE THE OWNER OF THE
CONTINUING LEGAL OBLIGATION AND/OR LIABILITY CONNECTED WITH STORM SURFACE WATER DISPOSITION. FURTHER, THE CITY OF
RENTON DOES NOT ACCEPTANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE SYSTEM PROVIDED DURING
CONSTRUCTION.
17. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARD, SAFETY DEVICES, PROTECTIVE EQUIPMENT,
FLAGGERS, AND ANY OTHER NEEDED ACTIONS TO PROTECT THE LIFE, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY
IN CONNECTION WITH THE PERFORMANCE OF WORK COVERED BY THE CONTRACT. ANY WORK WITHIN THE 'TRAVELED RIGHT OF WAY THAT
MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE AN APPROVED TRAFFIC CONTROL PLAN BY THE TRAFFIC ENGINEERING DIVISION
OF THE DEPARTMENT OF PUBLIC WORKS. ALL SECTIONS OF THE W.S.D.03. STANDARD SPECIFICATIONS 1-07-23, TRAFFIC CONTROL,
SHALL ArPLY.
18. SPECIAL DRAINAGE MEASURES WILL BE REQUIRED IF THE PROJECT LOCATION IS WITHIN THE AQUIFER PROTECTION AREA (APA).
1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING MUST BE HELD WITH THE CITY OF
RENTON DEPARTMENT OF PUBLIC WORKS, DESIGN ENGINEER.
2. ALL LIMITS OF CLEARING AND AREAS OF VEGETATION PRESERVATION AS PRESCRIBED ON THE PLAN SHALL BE CLEARLY FLAGGED IN
THE FIELD AND OBSERVED DURING CONSTRUCTION.
3. ALL REQUIRED SEDIMENTATION/EROSION CONTROL FACILITIES MUST BE CONSTRUCTED AND IN OPERATION PRIOR TO LAND CLEARING
AND/OR OTHER CONSTRUCTION TO INSURE THAT SEDIMENT LADEN WATER DOES NOT ENTER THE NATURAL DRAINAGE SYSTEM. ALL
EROSION AND SEDIMENT FACILITIES SHALL BE MAINTAINED IN A SATISFACTORY CONDITION UNTIL SUCH TIME THAT CLEARING AND/OR
CONSTRUCTION 1` COMPLETED AND POTENTIAL FOR ON -SITE EROSION HAS PASSED. THE IMPLEMENTATION, MAINTENANCE, REPLACEMENT
AND ADDITIONS TO EROSION/SEDIMFNTATION CONTROL SYSTEMS SHALL BE THE RESPONSIBILITY OF THE PERMITTEE,
4. THE EROSION AND SEDIMENTATION CONTROL SYSTEMS DEPICTED ON THIS DRAWING ARE INTENDED TO BE MINIMUM REQUIREMENTS TO
MEET ANTICIPATED SITE CONDITIONS. AS CONSTRUCTION PROGRESSES AND UNEXPECTED OR SEASONAL CONDITIONS DICTATE, THE
PERMITTEE SHALL ANTICIPATE, THAT MORE EROSION AND SEDIMENTATION CONTROL FACILITIES WILL BE NECESSARY TO INSURE COMPLETE
SILTATION CONTROL ON THE PROPOSED SITE. DURING THE COURSE OF CONSTRUCTION, IT SHALL BE THE OBLIGATION AND
RESPONSIBILITY OF T14L PERMITTEE TO ADDRESS ANY NEW CONDITIONS THAT MAY BE CREATED BY HIS ACTIVITIES AND TO PROVIDE
ADDITIONAL FACILITIES, OVER AND ABOVE MINIMUM REQUIREMENTS, AS MAY BE NEEDED TO PROTECT ADJACENT PROPERTIES AND WATER
QUALITY OF THE RECEIVING DRAINAGrE SYSTEM.
5. APPROVAL OF THIS PLAN IS FOR EROSION/SEDIMENTATION CONTROL ONLY. IT DOES NOT CONSTITUTE AN APPROVAL OF STORM
DRAINAGE DESIGN, SIZE NOR LOCATION OF PIPES, RESTRICTORS, CHANNELS, OR RETENTION FACILITIES.
6. DURING THE TIME PERIOD OF NOVEMBER 1 THROI "^!! MARCH 31, ALL PROJECT DISTURBED SOIL AREAS GREATER THAN 5,000
SQUARE FEET, THAT ARE TO BE LEFT UNWORKED FOR MORE THAN TWELVE (12) HOURS, SHALL BE COVERED BY MULCH, SODDING, OR
PLASTIC COVERING,
7. IN ANY AREA WHICH HAS BEEN STRIPPED OF VEGETATION AND WHERE NO FURTHER WORK IS ANTICIPATED FOR A PERIOD OF 30
DAYS OR MORE, ALL DISTURBED AREAS MUST BE IMMEDIATELY STABILIZED WITH MULCHING, GRASS PLANTING OR OTHER APPROVED
EROSION CONTROL TREATMENT APPLICABLE TO THE TIME OF YEAR IN QUESTION. GRASS SEEDING ALONE WILL BE ACCEPTABLE ONLY
DURING THE MONTHS OF APRIL THROUGH SEPTEMBER INCLUSIVE. SEEDING MAY PROCEED, HOWEVER, WHENEVER IT IS IN THE INTEREST
OF THE PERMITTEE, BUT MUST BE AUGMENTED WITH MULCHING, NETTING, OR OTHER TREATMENT APPROVED BY THE CITY OF RENTON,
OUTSIDE THE SPECIFIED TIME PERIOD.
10 ID 0 11
TACOMA S E A T T L E
2215 North 30th Street, Suite 300, Tacoma, WA 98403
316 Occidental Avenue South, Suite 320, Seattle, WA 98104
Civil Engineers
EXISTING DESCRIPTION PROPOSED
POWER/TELE. POLE
GUY WIRE
CATCH BASIN
STORM DRAIN MH
SANITARY SEWER MH
SIGN
HYDRANT
CONTOURS
-------- WATER LINE _w
CHAIN LINK FENCE -X-X-X-X-
SPOT ELEVATION XXX.XX_
ALTERNATE 1
SIDEWALK AND PLANTER STRIP
(TYP)
ALTERNATE 2
A
A
LEGEND
DESCRIPTION
STANDARD DUTY A/C PAVING ....... .........
CONCRETE PAVING
NEW GRASS
FIRE LANE MARKING
Q>
C
A
DRIVEWAY OR ALLEY
SEE ZONING CODE FOR
FOR MAX & MIN WIDTHS
10" COMMERCIAL ZONE
6" RESIDENTIAL ZONE
SIDEWALK NEXT TO CURB
L 10" COMMERCIAL ZONE
(NO PLANTER STRIP) 6"
RESIDENTIAL ZONE
THICKENED
BASE OF CURB & GUTTER
TO
MATCH APPROACH THICKNESS
ON
COMMERCIAL APPROACHES. (TYP)
NOTES:
1,
DUMMY JOINTS SHALL BE PLACED NOT TO EXCEED 15' C/C NOR LESS THAN
10- C/C. THEY SHALL
NOT BE LESS THAN 3/16" IN THICKNESS AND SHALL BE 2-1/4" DEEP.
2.
1/2" THRU JOINTS SHALL BE PLACED AT BACK, SIDES AND FRONT (BEHIND
CURB) OF APPROACH,
AND IN CURB/GUTTER TO DUMMY JOINTS.
3.
CEMENT CONCRETE SHALL BE CLASS 3000 AIR ENTRAINED,
4.
ALL JOINTS SHALL BE CLEANED AND EDGED.
5.
APPROACH SHALL NOT BE POURED INTEGRAL WITH CURB AND GUTTER, BUT
MAY BE POURED
INTEGRAL WITH STANDARD CURB (SEE DETAIL "A").
6.
SUBGRADE COMPACTION SHALL BE 95% MODIFIED PROCTOR.
7.
APPROACH CENTERLINE TO MATCH THE DRIVEWAY/ALLEY CENTERLINE.
THE APPROACH WIDTH WILL BE 10' WIDER THAN THE DRIVEWAY/
ALLEY WIDTH.
Structural Engineers 0
NIX
Landswe Architects S.
OF A'S
Communitv Planners
Land Surveyors JL 1-yr
Neighbors
IONAL
253.383.2422 TEL
:
206,267.2425 TEL FXPIRES
NO.
REVISION
SURVEYOR
AHBL
2215 NORTH 30TH STREET
TACOMA, WA 98403
PHONE: 253-383-2422
FAX: 253-383 2572
CONTACT: JOHN BECKER, PILS
CIVIL ENGINEER
AHBL
2215 NORTH 30TH STREET
TACOMA, WA 98403
PHONE: 253-383-2422
FAX: 253-383-2572
CONTACT: CAROL HURST, P.E.
CURB AND GUTTER SHOWN
HOWEVER, OTHER CURBS
MAY BE USED.
(SEE STANDARD PLANS)
10/22/96
hics, text. Added note
Edited graphics,
BY I DATE I APPR I
SURNT TD
DUSIGNTD.
CN111
DRAXN_11
CN11 I
CHECKM
DGT
SCALE,
L-L
<
LL
Cc
6' MIN
LL_
0 <
0
2 (TYP) 0-1
a-
< o-
<
SEE DETAIL "A"
SECTION A -A
-6
JOINT - 3 16" SCORE LINE
-1811
m
0
w
CEMENT CONCETE APPROACH
FOR DRIVEWAYS AND ALLEYS
00 0
y ADOPTED
CITY OF RENTON
+
�/ STANDARD PLANS
lip T7
Y � *X�
)",� 1� LST DATE: 12'06
DWG. NAME: 1' RO IN
VER FICAL NAVD 11118
NOTED
",IZ RONTAL T) 19 NA83;1�-)]
I
f DATUM
ONE INCI I I
AI FULL SCALE
II NOT ONT, TN( F
SC.kLF. ACCORDrNG] V
` Y MAIP
V �C' MT
NTS
SP PAGE: F006
�i-325oc
t" R CITY OF
ML
RENTON
Plaiiniiig/Btiildillg,/]'LlbliC Works Dept.
TRENCH NOTE
IF WORKERS ENTER ANY TRENCH OR OTHER EXCAVATION FOUR OR MORE FEET IN DEPTH
THAT DOES NOT MEET THE OPEN PIT REQUIREMENTS OF WSDOT SECTION 2-09.3(3)lj, IT
SHALL BE SHORED AND CRIBBED. THE CONTRACTOR ALONE SHALL BE RESPONSIBLE' FOR
WORKER SAFETY AND AHBL ASSUMES NO RESPONSIBILITY. ALL TRENCH SAFETY SYSTEMS
SHALL MEET THE REQUIREMENTS OF THE WASHINGTON INDUSTRIAL SAFETY AND HEALTH
ACT, CHAPTER 49.17 RCW. CHAPTER 49.17 RCW.
UTILITY NOTE
THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE APPROXIMATE ONLY AND HAVE
NOT BEEN INDEPENDENTLY VERIFIED BY THE OWNED OR ITS REPRESENTATIVE. THE
CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE
COMMENCING WORK AND AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES
THAT HAPPEN DUE TO THE CONTRACTOR'S FAILURE TO LOCATE EXACTLY AND PRESERVE
ANY AND ALL UNDERGROUND UTILITIES. AHBL ASSUMES NO LIABILITY FOR THE LOCATION
OF UNDERGROUND UTILITIES,
TOPOGRAPHIC NOTE
THE EXISTING CULTURAL AND TOPOGRAPHIC DATA SHOWN ON THESE DRAWINGS HAS BEEN
PREPARED, IN PART, BASED UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS
INFORMATION IS BELIEVED TO BE RELIABLE, AHBL CANNOT ENSURE ACCURACY AND THUS
IS NOT RESPONSIBLE FOR THE ACCURACY OF THAT INFORMATION OR FOR ANY ERRORS OR
OMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO THESE DRAWINGS AS A RESULT.
FILL SPECIFICATION
FILL MATERIAL SHALL NOT CONTAIN PETROLEUM PRODUCTS, OR SUBSTANCES WHICH ARE
HAZARDOUS, DANGEROUS, TOXIC, OR WHICH OTHERWISE VIOLATE ANY STATE, FEDERAL, OR
LOCAL LAW, ORDINANCE, CODE, REGULATION, RULE, ORDER, OR STANDARD,
SHEET
INDEX
SHEET NO.
SHEET TITLE
C1.0
COVER SHEET
C2.1
UTILITY AND PAVING PLAN
C2.2
DETAILS AND NOTES
CHECKED FOR COMPLIANCE
TO CITY STANDARDS
Date
Date
Date
DAIL
HILLCREST ELEMENTARY SCHOOL 5/23/05
PORTABLE CLASSROOMS 2005
RENTON SCHOOL DITRICT NO 405 Didvv
C1.0
OF
COVER SHEET
SO-500
9 W05