Loading...
HomeMy WebLinkAboutWWP2703254.20 �0o Y a O U O Z m ow< o a I n- ca J Q 0 Q w� r O Z W = Ill co Z 0 w U Q) v o w Q a O O O E W _DW v� v' v vE Q S E \ E o � v'N c �I c � d L m o � 0 oz Q U Q 0 jN o 0 W Z 3 o w a Z z a to o w Q w a- Q mI z O cn Ln_ cn z z �It w � U U O w Lim o_ 0- o 0 ii o I~,INI�I z CITY OF RENTON SANITARY SEWER NOTES AND SPECIFICATIONS 1. ALL WORK MATERIALS SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON UTILITY DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS. 2. THE HOURS OF WORK IN THE STREET RIGHT-OF-WAY SHALL BE LIMITED TO 8:30 A.M. TO 3:30 P.M. ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE DEPARTMENT OF PUBLIC WORKS AT 235-2620. ALL STREET CLOSURES, PARTIAL OR FULL, SHALL BE APPROVED BY THE DEPARTMENT OF PUBLIC WORKS 24 HOURS IN ADVANCE. THE POLICE DEPARTMENT, FIRE DEPARTMENT AND 911 SHALL BE NOTIFIED 24 HOURS IN ADVANCE. 3. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH "STANDARD SPECIFICATIONS FOR MUNICIPAL PUBLIC WORKS CONSTRUCTION" PREPARED BY WASHINGTON STATE CHAPTER AMERICAN PUBLIC WORKS ASSOCIATION, LATEST EDITION (APWA) AND CITY OF RENTON STANDARD SPECIFICATIONS. 4. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. 5. A PRECONSTRUCTION CONFERENCE AND A 24-HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. (INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON). IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE UTILITY DEPARTMENT 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. 6. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE. 7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO ANY CONSTRUCTION. 8. PLANS APPROVED BY THE CITY OF RENTON, PUBLIC WORKS DEPARTMENT SHALL TAKE PRECEDENCE OVER ALL OTHER PLANS. 9. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 10. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN AS -BUILT DRAWING OF THE SANITARY SEWER SYSTEM WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER OR LICENSED PROFESSIONAL SURVEYOR. 11. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A LOOSE AVERAGE DEPTH OF 6 INCHES, MAXIMUM DEPTH OF 8 INCHES, THOROUGHLY TAMPING EACH LAYER TO 95 PERCENT OF MAXIMUM DENSITY. THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR TO THE SIDE OF THE TRENCH. MATERIALS TO COMPLETE THE FILL OVER PIPE SHALL BE THE SAME AS DESCRIBED. 12. DATUM SHALL BE CITY OF RENTON, U.S.C. AND G.S. 13. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED TO THE SATISFACTION OF THE DEPARTMENT FOR THE PREVENTION OF ON -SITE EROSION AFTER THE COMPLETION OF CONSTRUCTION. 14. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH SECTION 7-02.3(1) OF THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE UNYIELDING BASE. PIPE BEDDING SHALL BE PEA GRAVEL 6 INCHES ABOVE AND BELOW THE PIPE. 15. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER GASKETED ASTM D 3034, SDR 35, OR DUCTILE IRON CLASS 50. 16. IN UNIMPROVED AREAS, MANHOLE TO EXTEND MINIMUM 6 INCHES AND MAXIMUM 18 INCHES ABOVE FINISHED GRADE. IN PAVED AREA, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING. 1 /2" WEB 8 PL. FRAME (NON -LOCKING RAISE- 1/2" WIDE BORDER SANITARY SEWER NOTES AND DETAILS H'I 0 3/4"- . .1 WINDSTOAFE II A PORTION OF THE SE 1/4 OF SEC. 31 T. 237 R. 5E, W.M., KING COUNTY, WASHINGTON 3/4" SQUARES SPACED - 3/4" AS INDICATED - HT. 1 /8" r-1 /2" 5/8" ,2 7 8 4' �7:- 813/4" 8' 15" CAST IRON RING AND COVER PIPE MATERIAL AS BY THE ENGINEER 12 "/ C FIBEF PACK 45' (1 /8) PLUG TO BE SEALED IN SAME MANNER AS MAIN SEWER JOINTS. 6" OR 8* CLEAN -OUT DETAIL NOT TO SCALE 'tox 3" x 3/8" NON-SKID ERN CAST INTEGRAL ON TOP COVER (NON -LOCKING) FOR 5/8"-11 N.C. x 1-1/4" B S.S. SOC. HD. CAP SCREW (3 REQ D.) TYP. TYP. NON-SKID PATTERN 0 D�Q o °o° _o B TAP 5/8"-11 N.C. ON 23" B.C.(TYP. 3 PL.) FRAME (LOCKING) IJJ-1/4 - SECTION A -A 13/8" 5/8" 3/8" 11- 2" 1 SEAT- I- II -1 I-2-1 /2" 25" 2" RAISED LETTERS AS REQ'D. SEE NOTE No.3 BELOW SECTION B-B UNDERSIDE SHOWN FOR CLARITY 3/4" CORE (TYP.) ON 23" B.C. 1-1/2" CORE(TYP.) (LOCKING) COVER NOTES: 1. FOR NON -LOCKING USE OLYMPIC FOUNDRY No. MH 30 OR EQUAL. 2. FOR LOCKING LID USE OLYMPIC FOUNDR CIFY "DRAIN" Y No. MH 30 D/T OR EQUAL. 3 SANITARY (SPECIFY "SEWER") USE FRAME AND COVER FOR SR ORWATER(SPECIFY "WA R' )OVER), MANHOLE FRAME AND COVER DETAIL NOT TO SCALE CONCRETE CLASS 3000 BACKFILL MATERIAL (SEE NOTE 5) CONCRETE CLASS C (SEE NOTE 8) FOUNDATION LEVEL BACKFILL MATERIAL (SEE NOTE 5) - BEDDING MATERIAL FOR RIGID PIPE (SEE NOTE 6) - FOUNDATION LEVEL BEDDING MATERIAL FOR FLEXIBLE PIPE (SEE NOTE 7) - FOUNDATION LEVEL (SEE NOTE 4 17 (CLASS A DESIGN) (SEE NOTE 4 LIMITS OF PIPE ZONE LIMITS OF PIPE ZONE (CLASS B, C, D, DESIGN) BEDDING FOR RIGID PIPE rW (SEE NOTE 4) LIMITS OF PIPE ZONE 11 0" NOTES: 1. PROVIDE UNIFORM SUPPORT UNDER BARREL. 2. HAND TAMP UNDER HAUNCHES. 3. COMPACT BEDDING MATERIAL TO 95% MAX. DENSITY EXCEPT DIRECTLY OVER PIPE, HAND TAMP ONLY. 4. SEE "EXCAVATION AND PREPARATION OF TRENCH" IN THE WITARY SEWERS SECTION OF THE STANDARD SPECIFICTATIONS FOR TRENCH WIDTH `W ' AND TRENCHING OPTIONS. THE PIPE ZONE WILL BE THE ACTAUL TRENCH WIDTH, EXCEPT FOR CLASS A BEDDING. THE MINIMUM CONCRETE WIDTH SHALL BE 1-1/2 I.D. + 18". 5. TRENCH BACKFILL SHALL CONFORM TO "BACKFILLING SEWER TRENCHES" IN THE SANITARY SEWERS SECTION QF THE STANDARD SPECIFICATIONS, EXCEPT THAT ROCKS OR LUMPS LARGER THAN 1' PER FOOT OF PIPE DIAMETER SHALL NOT BE USED IN THE BACKFILL MATERIAL. 6. SEE "BEDDING MATERIAL FOR RIGID PIPE" IN THE AGGREGATES SECTION OF THE STANDARD SPECIFICATIONS FOR THE MATERIAL SPECIFICATIONS. 7. SEE "BEDDING MATERIAL FOR FLEXIBLE PIPE" IN THE AGGREGATES SECTION OF STANDARD SPECIFICATION FOR THE MATERIAL SPECIFICATIONS. 8. PIPE MUST BE ANCHORED IN SUCH A MANER AS TO ENSURE FLOW LINE IS MAINTAINED. BEDDING CLASS DESIGN DIMENSION CLASS A CLASS B CLASS C CLASS D CLASS F A 4" MIN. 1 /4 I.D. 1 MAX. * * ZERO B 1/4 O.D. 1/2 O.D. 1/8 O.D. ZERO O.D. C 3/4 O.D. 1/2 O.D. 1/8 O.D. O.D. - * A = 4" MIN. 27" I.D. AND UNDER 6" MIN. OVER 27" I.D. (CLASS F DESIGN) BEDDING FOR FLEXIBLE PIPE PIPE BEDDING FOR SANITARY SEWERS NOT TO SCALE PROPERTY LINE 3'-0" MIN. ; 6'-0" FUTURE 6" BUILDING SEWER PIPE BUILDING SEWER Im Z ` 2"x 4" STUD SERVICE MARKER PAINT UPPER TEE WITH 6" SIDE OUTLET PORTION WHITE ANS STENCIL ON SIDE Of RDING HIGH BLACKS 6" SIDE AND #6 WIREWERWRA PIED AROUND THE STU AND3" SEWER AND BUILDING SEWER o i EXTENDED TO THE TOP OF THE STUD. ate' UNLESS OTHERWISE APPROVED BY THE CITY MAKE TAP THROUGH CAST IRON SADDLE SECURED TO SEWER MAIN WITH STAINLESS STEEL BANDS WHEN CONNECTING NEW SIDE SEWERS TO EXISTING MAIN. VITRIFIED CLAY, PLAIN AND REINFORCED CONCRETE, D1 PIPE AND Cl PIPE SEWER MAINS ARE TO BE CORE DRILLED 60" ALLOWABLE MAX. FOR CAST IRON PIPE OR DUCTILE IRON PIPE. 1:3:5 MIX - CONCRETE BLOCKING 6" SIDE OUTLET TEE 6" MIN. SEWER MAIN CONCRETE BLOCKING ANGLE OF TEE AT MAIN OVER 25 MP NGR� G� 2% MIN SL HORIZONTAL SEWER MAIN TYPICAL SIDE SEWER ELEVATION PE ELEVATION NOTE: UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 5' COVER AT PROPERTY LINE OR 3-5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER. STANDARD SIDE SEWER INSTALLATION 1 1/4" HDPE (SEWER MAIN TO PROPERTY LINE) PRESSURE LINE (TYP.) NOT TO SCALE 6" PVC 1 1/4" HDPE A 1 1/4" HDPE a SEWER MAIN PRESSURE PRESSURE LINE (TYP.) LINE (TYP.) 6" SIDE 6"x 1 1 /4" 6" SIDE 6"x 1 1/4" 6" SIDE 6"x 1 1 /4" 6" SIDE 6"x 1 1 /4" SEWER WYE SEWER WYE SEWER WYE SEWER WYE PLAN VIEW A4 SIDE SEWER FORCEMAIN CONNECTION DETAIL NOT TO SCALE 3-J25404 SECTION A -A 6" SANITARY SEWER CLEANOUT By: Date: By: Date: By: Date By: Date -32'�40t CD W Z - z O Z > 0 O Q z loo- F a) Q z r s I Z N Z O r Ill � z f-- U 0 J Z 0 0 Q 0 0 rn O W ZIL O m O O � U Z 2 EL OD V Q x z 0 J W = g O M W J m O r W m _ a U Q CD 0 = ca C)E z> z� g U) w z Q o_ J a Lu Q h7 N Ll N QZ L c� o m ® 0 z- z� CD w CN Q I eI Lu z Ln N .... Ln N C7 Z z- w 00 Y�� > FjV) o Q a�2 J 0 Q 0 i _ -- z �►-LuQ) ft� _ L qg/ P�1 SADR �E W A S111 ti 24661 /STE��G\��� O AL EXPIRES 6 11 �.s m