��g��QO�m PORTION OF THE N.E. 1/4,, OF SEC. 15, TWN 23 N., RGE 5 E., W.M.
CITY OF RENTON, WASHINGTON
J
ry w
D 0
O o
U z
Q
W
z w
O
ry
Q w
w
or
L
W
03
0
V
�
W
Y
y
O
U
3
3
3
<
Q
o
W
�o0
o
uiuiI?
L_
U_
>_
m
_
a
Lp
r�
to
0
0
01
(U
cu
O
rn
3:
c_n
w
w
z
->
->
�
W
W
o
o
Q
U
U
tU
Q_
w
m
Li
a
W
a
3
D
(0
N
z
z
0
0
0
o
Q
T
Ln
}
`�
w
w
of
a
(`M
N
i
0
0
MORTAR
FILLET
101
MANHOLE FRAME AND COVER
SEE DRAWING BR29
ADJUSTMENT (4" MIN.)
CONE
RUBBER GASKETED JOINTS
IN ACCORDANCE WITH ASTM C-443
STEPS - 3/4" DEFORMED BAR
STEPS SHALL BE INCLUDED
CONCRETE RISER BY PIPE INC.,
OR APPROVED EQUAL.
MAX. PIPE SIZE - 21" I.D.
LADDER -STD. ALUMINUM
OR GALVANIZED STEEL
CONCRETE SHELF
PRECAST BASE SECTION
OR CAST IN SHELF,
SANITARY MANHOLE TYPICAL DETAIL
NOT TO SCALE
6" BUILDING SEWER PIPE
TEE WITH 6" SIDE OUTLET
6" SIDE SEWER AND BUILDING SEWER
60" ALLOWABLE MAX.
FOR CAST IRON PIPE
OR DUCTILE IRON PIPE.
1:3:5 MIX tx�
CONCRETE -�-
BLOCKING
r—� M
6" SIDE OUTLET TEE
SEWER MAIN
6" MIN.
CONCRETE BLOCKING ANGLE
OF TEE AT MAIN OVER 25
ELEVATION
SEWER MAIN
Z_
0
1
n
NOTES:
1. STEPS TO BE 3/4" 0 DEFORMED BAR GALVANIZED SAFETY
STEPS OR EQUAL.
2. STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS
ARE INSTALLED.
3. CASTING TO BE PER DRAWING BR29.
4. MANHOLE SECTIONS TO BE OF REINFORCED PRECAST
CONCRETE.
5. ALL JOINTS SHALL BE GROUTED.
6. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR
SURFACES, INCLUDING CHANNELING, COATED (SEALED)
WITH A HIGH SOLIDS URETHANE COATING;
WASSER MC-CONSEAL OR APPROVED EQUAL;
COLOR OF COATING SHALL BE WHITE.
7. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE
WITH ASTM C-443.
8. CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 THE INSIDE
DIAMETER OF THE LARGEST PIPE.
9. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK
ADAPTOR, KOR-N-SEAL BOOTS OR APPROVED EQUAL.
PROPERTY LINE
6'- 0"
FUTURE
BUILDING SEWER
n
py
Ld
z 2 x 4 STUD SERVICE MARKER PAINT UPPER
PORTION WHITE ANS STENCIL ON SIDE
WORDING "SEWER" WITH 3" HIGH BLACK LETTERS.
w AND #6 WIRE WRAPPED AROUND THE STUD AND
Q- EXTENDED TO THE TOP OF THE STUD.
af
UNLESS OTHERWISE APPROVED BY THE CITY, MAKE TAP THROUGH CAST
IRON SADDLE SECURED TO SEWER MAIN WITH STAINLESS STEEL BANDS
WHEN CONNECTING NEW SIDE SEWERS TO EXISTING MAIN.
VITRIFIED CLAY, PLAIN AND REINFORCED CONCRETE, D1 PIPE AND C1
PIPE SEWER MAINS ARE TO BE CORE DRILLED
OU
GO 2% MIN SLOPE -
HORIZONTAL
TYPICAL SIDE SEWER ELEVATION
NOTE:
UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2.5' COVER AT PROPERTY
LINE OR 3-5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER.
STANDARD SIDE SEWER INSTALLATION DETAIL
NOT TO SCALE
5-�27'�AS
10"
9„
8-3/4"
1-1/4" 1/2" 2"
SQUARES SPACED - 3/4"
NDICATED - HT. 1 /8"
1/2"
RAISE-1/2"
WIDE BORDER
5 /8„
2-7/8"
CAST IRON RING AND COVER
NOTE:
IN UNIMPROVED AREAS POUR 1'-0" THICK
2'-0" SQUARE CONCRETE, CLASS 3000, PAD AROUND
RING AND COVER.
IN ASPHALT ROADWAYS RESTORE AROUND CLEANOUT RING
AND COVER AS REQUIRED BY STANDARD DETAIL DRAWING BR36.
FIBER
PACKIf
45- (1 /8)
PIPE MATERIAL AS SPECIFIED
BY THE ENGINEER
2'-0"
PLUG TO BE SEALED
IN SAME MANNER AS
MAIN SEWER JOINTS.
SANITARY SEWER CLEANOUT DETAIL
NOT TO SCALE
CONCRETE
CLASS 3000
3/4"
SANITARY SEWER NOTES AND SPECInCAI)ONS
1. ALL WORK MATERIALS SHALL BE IN CONFORMANCE WITH THE
STANDARDS AND SPECIFICATION OF THE CITY OF RENTON UTILITY
DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA
STANDARDS AND SPECIFICATIONS.
2. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH STANDARD
SPECIFICATIONS FOR MUNICIPAL PUBLIC WORKS CONSTRUCTION'
PREPARED BY WASHINGTON STATE CHAPTER AMERICAN PUBLIC
WORKS ASSOCIATION, LATEST EDITION (APWA) AND CITY OF
RENTON STANDARD SPECIFICATIONS
J. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE
APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S
RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO
AS TO AVOID DAMAGE OR DISTURBANCE.
4. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS,
METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE
SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION S1 TE.
5. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO
OBTAIN STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO
ANY CONSTRUCTION.
6. PLANS APPROVED BY THE CITY OF RENTON, PUBLIC WORKS
DEPARTMENT SHALL TAKE PRECEDENCE OVER ALL OTHER PLANS.
7. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB
SITE WHENEVER CONSTRUCTION IS IN PROGRESS
8. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH
AN AS-BUIL T DRAWING OF THE SANITARY SEWER SYSTEM, WHICH
HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL
ENGINEER OR LICENSED PROFESSIONAL SURVEYOR.
9. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE
PIPE IN LAYERS WITH A LOOSE AVERAGE DEPTH OF 6 INCHES,
MAXIMUM DEPTH OF 8 INCHES, THOROUGHLY TAMPING EACH LAYER
TO 95 PERCENT OF MAXIMUM DENSITY. THESE COMPACTED
LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF
THE PIPE OR TO THE SIDE OF THE TRENCH. MATERIALS TO
COMPLETE THE FILL OVER PIPE SHALL BE THE SAME AS
DESCRIBED,
10, OPEN CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON
EXISTING TRAVELED ROADWAY SHALL BE BACKFILLED WITH
CRUSHED ROCK AND MECHANICALLY COMPACTED. CUTS INTO THE
EXISTING ASPHALT SHALL BE NEATLINE CUT WITH SAW IN A
CONTINUOUS LINE. A TEMPORARY MIX PATCH MUST BE PLACED
IMMEDIATELY AFTER BACKFILL AND COMPACTION A PERMANENT
HOT MIX PATCH SHALL BE PLACED WITHIN 10 DAYS AND SHALL BE
PER CITY OF RENTON CURRENT STANDARDS.
11. DATUM SHALL BE CITY OF RENTON, 1988 NAVD.
12. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR
OTHERWISE STABILIZED TO THE SATISFACTION OF THE DEPARTMENT
FOR THE PREVENTION OF ON -SITE EROSION AFTER THE
COMPLETION OF CONSTRUCTION.
13. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A
PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH SECTION
7 OF THE CURRENT STATE OF WASHINGTON STANDARD
SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION. THIS
SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR
THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT
AND COMPACTION OF REQUIRED BEDDING MATERIAL, TO UNIFORM
GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE
SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. PIPE
BEDDING SHALL BE PEA GRAVEL 6 INCHES ABOVE AND BELOW THE
PIPE.
14, SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC)
RUBBER GASKETED ASTM D 3034, SDR 35, OR DUCTILE IRON
CLASS 50.
15, IN UNIMPROVED AREAS, MANHOLE TO EXTEND MINIMUM 6
INCHES AND MAXIMUM 12 INCHES ABOVE FINISHED GRADE IN
PAVED AREA, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH
PAVING.
RECOMMENDED
FOR APPROVAL
BY
EXPIRES 11/30/06
BY
CallBY
before you CHECKED FOR COMPLIANCE
Dj g. Tp CITY STANDARDS
1-800-424-5555 DAM
UNDERGROUND SERVICE (USA) DINE
AVOID CUTTING UNDERGROUND
UTILITY LINES. ITS COSTLY DATE
NOTE:
EXISTING UTILITY LOCATIONS SHOWN HEREON ARE APPROXIMATE ONLY.
IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE
EXACT VERTICAL AND HORIZONTAL LOCATION OF ALL EXISTING UNDER-
GROUND UTILITIES PRIOR TO COMMENCING CONSTRUCTION. NO
REPRESENTATION IS MADE THAT ALL EXISTING UTILITIES ARE SHOWN
HEREON. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR UTILITIES
NOT SHOWN OR UTILITIES NOT SHOWN IN THEIR PROPER LOCATION.
CALL BEFORE YOU DIG: 1-800-424-5555.
" SCANNED MAY 0 12006