WWP2703278.4
JB A, Fa ©LS L F CH IL i/2SP c v LS 1 L� GFI SUMP PUMP ONLY NOTES 0 DEDICATED RECEPTACLE FOR SUMP PUMP --LABEL AS INDICATED. (N❑ GFI.) 0 ALL ELECTRICAL EQUIPMENT WITHIN WETWELL AND HANDH❑LES TO BE RATED EXPL❑SI❑N-PROOF CLASS I, DIV, L 0 UNDERGROUND SCH 40 PVC CONDUIT (RGS TO 5' FROM STRUCTURES. WRAP HALF -LAPPED WITH 10mL TAPE,) HANDHOLE UTILITY VAULT MODEL N❑, 233LA W/ GALVANIZED COVER MARKED POWER OR CONTROL, POUR TOPPING SLAB ON BASE SLAB TO PROVIDE POSITIVE DRAINAGE TO WETWELL. THREE-WAY SWITCH (2) TO ACTIVATE MCC INTERIOR LIGHTS, RESURFACE BOTTOM SLAB TO PROVIDE DRAINAGE THROUGH 2" PASSAGE PORT TO WETWELL. © INTRUSION LIMIT SWITCH: SIEMENS MODEL NO, 3SE03ARI (INTRUSION), THREE REQUIRED, FLOOD ALARM SWITCH: MADISON CO, MODEL NO, 4YM31-1, MOUNT 2" ABOVE VAULT FLOOR, ZL CHECK VALVE LIMIT SWITCH (2): SIEMENS MODEL NO, 3SE03ARL (PUMP FAIL) Q 1/2 HP SUMP PUMP PACE] MODEL NO. PIP701C WITH INTEGRAL LEVEL CONTROL FLOAT, A EXPLOSION -PROOF LIGHT FIXTURE: APPLETON MODEL NO, AAU15N, 20OW LAMP, SIEMENS MA63100/5000 MAGNETIC FLOWMETER WITH DISPLAY UNIT MOUNTED ADJACENT TO RTU, KPSI WETWELL LEVEL TRANSMITTER MODEL 720-140-00010-009 WITH UNSPLICED CABLE TO HH2, CABLE HANGAR, LIGHTNING PROTECTION, AND VAPOR BARRIER WITH ANEROID BELLOWS MODEL 815, BELLOWS MOUNTED IN MCC, A POLE -MOUNTED YARD LIGHT, (HIGH PRESSURE SODIUM LIGHT WITH BRONZE FINISH, LITHONIA MODEL NO, AS1-150S-SR3-TB-RPA-LPI-DDB, POLE LITHONIA MODEL NO. RSA-12-4C-DM19-AS-DDBJ LEVEL CONTROL FLOATS FOR, TRANSFER PUMP (3), 3/4" SPARE TO VAULT PIPING ' XGR 3/4" CONTROL CABINET VALVE VAULT 612-1 A 4 41A 1 414G 1 SIGNAL CABLE 3/4" RTU PNL L 4 #12 1 #12G PSE TRANSFORMER 480/277 4W SERV }150A 3P SUSE - U/L 100A 7JAW KwH METER BASE M 30, 4W 150A KIRK KEY 3P INTERLOCK Q ONLY LOAD SIDE TO BUSSES I 5A FU VS VM 3P 1 A FU 3,0 3P -- AM 0 MON 50A PUMP 1 (25 HP) SEE SHT 12 NOTE 1 50A 1 3P 480x120 26'0 WETWEL & OVERFLOW STORAGE STRUCTURE MOUNTED ON EAST END OF MCCT ATYP, FS REWSM 100A GEN RE( APP ADR1034 4W W/ GRD 100A KIRK KEY 3P INTERLOCK Q ONLY LOAD SIDE TO BUSSES fc>—� AM 50A PUMP 2 (25 HP) 50A 3P 480x 120 sSRVS MINI- pp SSRVS MINI - CAS 1 OT CAS �OT To/L SFIL 1 To/L SFIL 1 1MR SFTP T SF LMR SFTP T SF MOIL i ETM (SIZE OL l ESTO FOR 25HP) HH2 LEGEND O EXPLOSION -PROOF JUNCTION BOX X 5/8 x 8' GROUND ROD EYS SEAL • CONDUIT STUB -UP 0 RECEPTACLE FAS FLOOD SWITCH FS FLOAT SWITCH MS MOTOR STARTER SP SUMP PUMP FM MAGNETIC FLOW METER 3, LIGHT #6 CU GRD TO DI FM IN VAULT MCC HEAT TAPE 1/2 HOTBOX ;�A 2#12,1#12G #2 GENERATOR GROUNDING ROD BUSS 1 'r LS© 3 #2 CU TO PSE 480V TRANSFORMER 0 6 #14, 1 #1415 KS2 FS,NF QO HH1 N G� 1" � PB1ss4$4 ��� 1 " �s 01 3 #8, 1 #815, 2 #14 SENSOR --EACH CONDUIT FE-XP3 1 #8G, 2 #14 SENSOR --EACH CONDUIT;RES 2" SCH 80 PVC FOR PUMP CORDS "CR-DESIGRINC, NTS "°"a',r•'11116 CITY OF WEDGEWOOD_.LIFT STATION 9-1-06 ss LP 9-1-06 cw EM-�A5 RENTON LP 8-1-05 cw ass Hs 5401 _NE _10TH-ST, "r LP 5-25-05 GW aee� DEM s s Ews ,;,� ; Plannk,g/Buridtng/PueQe Works Dept. 1 412 E P t IT DIAGRAM l HH1 1/2" �[ J 1/2" PNL L 2 #12, 1 #126 HH2A C C '-' �D 2" 1 N (Z 9Y DATE APPR 1"1112z src;Ne;RINc;,Nc. LEC._ WR_&_SIGNAL_COND) _ 6 ONE —LINE DIAGRAM T MOIL ( ETM l OC SIZE OL ESTO SIZE 1 (SIZE OL FOR 25HP) F HH2 FOR 2.2 25 ) ( 25 LEGEND S/N 0 CONNECTION POINT NEUTRAL BYMCC MFR GENERATOR SFIL SEAL FAIL INDICATOR LIGHT SFTP SEAL FAIL / TEMPERATURE PROBE MOIL MOTOR OVERLOAD INDICATOR LIGHT 10' MAT ETM HOUR METER REBAR #4 5/8x8' #6 MIN. OC START COUNTER 5/8x8' 5/8x8' HH1 ELECTRICAL HANDHOLE G/R G/R 6" DI PIPE FM IN VALVE VAULT 30A 3P AM c1 T- VV g O 10A 2O jog tP 30A p o 2P CIRCUIT PUMP-T (2.2 HP) 0 BREAKER 't' � kJ� NOTE 1EE SHT 12 1 10A 131 ss �4 l 3P� s�i"EG� 5KVA TRANSFORMER aNAL 480 x 120/240 1�S 480x120 EXPIRES MINI — CAS Tor - � o/L _ SFIL T SF _LMR SFTP T MOIL 30A j ETM 2P l ESTO VAULT RECPT 0 20A 20A 0 VAULT SUMP PUMP HH2 WETWELL LTS � 20A 20A � MCC ENCLOSURE LTS TELEM RTU � 15A 15A � FLOW METER 15A 15A MCC RECPT HOTBOX FREEZE PROTECT. MCC PANEL HTR � 20A 20A � GFI RECPT ® MCC SPARE � 2QA 20A SPARE 2.2 PANEL L ' R`ESIGNJNC. _' ^ Nis ' CITY OF nIEDGEWOOD_LIFT STATION 9-1-0e �- -06 GW 'raw-'YsiEMs RENTON 5401_NE -10TH ST.�- -05 Gw a o-,7srEus ,� a Pynning/BuHd"/Public Works Dept. 412 REvlsla�l IBY I DATE�PPR ,r.e� �,,oe,� ONE LINE DIAGRAM 1315 ^n-H2cNGINEERING,INC. --- ANTENNAPUMP SECTION DOOR LAYOUT YARD LIGHT TRANSFER PUMP PUMP 1 20" 20" 20" 20-1 PUMP 1 0 - HOUR METER HOUR METER 12" - VOLT METER - PHASE MONITOR — �ACKPAN�THIS TION RTU START COUNTER START COUNTER NORMAL POWER (NO BUSSES) } } TRANSFORMER ® � G AM NOTE O DISCONNECT aG -' 100 FLOWMETER RUN 0-20A RUN 0-50A 72" MODULE KWH METER °� SURGE RTU �p 2 NOTE ® KK PROTECTO NOTE ® (24x24x8) PUMP 2 OFF�3 ^'� NOTE Q'� NOTE1 SEAL FAIL SEAL FAIL 90" NOTE 0 _ GENPOWER R 100 NOTE ® o}2P30 NOTE (I NOTE ® Y�`C H �A� °�' Yt�FR OVER TEMP OVER TEMP °Q $P NOTE &) KK 120/240 QD ® O O NOTE ® RECPT NOTE Q ® PACE 1 PH QD GF1 HOTBOX ® RESET ESTOP RESET ESTOP U NON - SERVICE °150 3P PNLBD PANEL L GFl PUMP 2 DI SWITCH CT °pt� USE 5KVA Fe N XFMR e HEAT TAPE HOUR METER GND NOTE 6" lb-f AWV� ® o.� �. START COUNTER pO 5/8" x 8' G/R ® �` 4t G AM #2 ® RUN 0-50A SLAB 1'-0 THICK x 4':- ,/ #5 REBAR ® 12" E.W. LENGTH AS RE D J CONC f'c= 3 KSI SEAL FAIL # 4 5/8 X ' G/RTYP �s QNt� l:iC 8' MIN. SPACING OVER TEMP 6 6" DI PIPE FM EXPIRES NOTES RESET ESTOP Q KIRK KEY INTERLOCK. NORMAL POWER X GENERATOR. ® PROVIDE 20OW EXPLOSION -PROOF WETWELL Q KEY SWITCH, SEWER INTRUSION --CITY STANDARD. INTERLOCK CIRCUIT BREAKERS IN THIS SECTION LIGHT FIXTURE, APPLETON MODEL NO. AAU 15N BEST ACCESS SYSTEMS IN WEATHERPROOF ENCLOSURE. TO PERMIT ONLY ONE BREAKER TO BE ENERGIZED. SWITCH FROM MCC FRONT 6?KIRK KEY ONLY. MCC EXTERIOR ENCLOSURE DOORS EQUIPPED WITH � ® PROVIDE DUAL LAMP FLUORESCENT FIXTURE FOR MCC INTRUSION SWITCHES - SIEMENS 3SE03AR1. I� RTM Q ENCLOSURE. MOUNT INSIDE ENCLOSURE TYPICAL RTU -FURNISHED BY CITY OF RENTON -DUPLEX UNIT ® PROVIDE SPACE HEATERS AND THERMOSTAT. WITH PROVISIONS FOR ADDITIONAL SENSING OF OVERFLOW OF TWO. OPERATE FROM THREE-WAY SWITCHES. e AND TRANSFER PUMP RUNNING. © 1-30" DOOR & 1-10" DOOR. START COUNTER ® PROVIDE LABELS AS SHOWN TO INDICATE EQUIPMENT IN EACH SECTION OF MCC AND ® SEE SHT 4 NOTE 25. DEDICATED RECPT & HEAT TAPE. ® MCP, (SSRVS--Pt & P2; SIZE 1 MOTOR STARTER--) FOR DEVICES MOUNTED ON DOORSO/L RESET BUTTON. j P LAYOUT BELOW, CONTROL WIRING POSITION AS REQUIRED BY iR/WSFER )• SEE DOOR . 6? LINE SIDE CONNECTIONS (TOP) FROM SERVICE BREAKER LOCATION OF MOTOR 0/L. DIAGRAM, AND ONE -LINE DIAGRAM @ MOUNT 3 PHASE VOLT METER AND SELECTOR - BY CONTRACTOR. LOAD SIDE TO BUSSES - BY MFR. ® PSE KWH METER - 200 AMP, 48OV, 3 PH, 4W, 7 JAW SWITCH ON DOOR OF THIS COMPARTMENT. E MOUNT BASE ®MIN. 5-6" ABOVE GRADE TO CENTER PHASE MONITOR - SIEMENS MODEL 3UG3013-18R60. ® LINE SIDE CONNECTIONS (TOP) FROM GENERATOR RECPT O E-STOP OF METER. - BY CONTRACTOR. LOAD SIDE CONNECTIONS TO BUSSES Q SURGE PROTECTION DEVICE - - BY MFR. ® GENERATOR RECPT - IOOA, 480V SIEMENS MODEL TPS-MCCE-1600C. (APPLETON MODEL ADR1034 WITH ® MOUNT FLOWMETER MODULE IN THIS SPACE. ® LABEL DEVICES AS INDICATED ON ENCLOSURE DOOR. APPLETON MODEL AJA100 ANGLE ADAPTER). DOOR -MOUNT IF POSSIBLE. ® GROUND ROD FOR GENERATOR W/ FOGTITE #37 BOX & ® COORDINATE WITH CITY OF RENTON UTILTTIES FOR #17 COVER. CORRECT PHASING OF GENERATOR RECEPTACLE PROVIDE ENCLOSURE FOR MCC. SIZE PER RECEPTACLE CONNECTIONS. FURNAS STT ANDARD. 15" DEEP MCC. ® SEE SHT 3 NOTE 7. -- -- - "'oEncN,Nc. N� e�63"�+.11�f�— CITY OF WEDGEWOODLIFT_STATION 9-1-06 z �s-eultT LP 9-1-06 cw - BAS - RENTON 5401 NE 10TH_ST. 1 DESIGN REdIE'N _ LP 8-9-05 GW 0 ORIGINAL ISSUE LP 5-25-05 GW o4 sYsras Ptanning/Building/Public Works Dept1412 �,o FURNAS OUTDOOR ELECTRICAL_ ENCLOSURE 1.�- 6-i (�. REVISION � DATE APPR '� �Z�INEEilING.NC. I — - I a 0 Of z w w w 54632V76 II I �. REVlstort aI N N LO o�'G"•'"G cw � �s cw " o,_s s as Gw es sr;TEus APPR �.r RH?�?IGINEERINC.INC, Nls -II �3m6SS.tAI. CITY OF RENTON TON Pt°nnl 8u4dktg/Pub4c works Dept _`— __ ` PE'DGE-WOOD LIFT STATION — 5401 NE 10TH ST. .-. PUMP1 ELECTRICAL SCHEMATIC - LP s-1-o6 w 8-24-Os lP 5-25-OS .� --- BY oNW 9-1-06 60— oft- 1412 '__ -0