MORTAR
FILLET
SE 132ND STREET • PUBLIC SANITARY SEWER EXTENSION
A PORTION OF THE SE 1/4 OF THE NW 1/4 OF SEC. 14, TWP 23N., RGE. 5E., W.M.
CITY OF RENTON, KING COUNTY, WASHINGTON
MANHOLE FRAME AND COVER
SEE DRAWING BR29
ADJUSTMENT (4" MIN.)
CONE
RUBBER GASKETED JOINTS
IN ACCORDANCE WITH ASTM C-443
STEPS - 3/4" DEFORMED BAR
STEPS SHALL BE INCLUDED
CONCRETE RISER BY PIPE INC.,
OR APPROVED EQUAL.
MAX. PIPE SIZE - 'E'
LADDER -STD. ALUMINUM
OR GALVANIZED STEEL
CONCRETE SHELF
PRECAST BASE SECTION
OR CAST IN SHELF.
SANITARY MANHOLE TYPICAL DETAIL_
NOT TO SCALE
NOTES:
1. STEPS TO BE 3/4" 0 DEFORMED BAR GALVANIZED SAFETY
STEPS OR EQUAL.
2. STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS
ARE INSTALLED.
J. CASTING TO BE PER DRAWING BR29.
4. MANHOLE SECTIONS TO BE OF REINFORCED PRECAST
CONCRETE.
5. ALL JOINTS SHALL BE GROUTED.
6. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR
SURFACES, INCLUDING CHANNELING, COATED (SEALED)
WITH A HIGH SOLIDS URETHANE COATING;
WASSER MC-CONSEAL OR APPROVED EQUAL;
COLOR OF COATING SHALL BE WHITE.
7. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE
WITH ASTM C-443.
8. CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 THE INSIDE
DIAMETER OF THE LARGEST PIPE.
9. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK
ADAPTOR, KOR-N-SEAL BOOTS OR APPROVED EQUAL.
A'
'B'
,C,
,D,
48" MH
48"
6" MIN.
5"MIN
24" MIN.
21 " I.D.
54„ MH
54„
8„ MIN.
5.5„ MIN.
24„ MIN.
24„ I.D.
60" MH
60"
8" MIN.
6" MIN.
42" MIN.
30" I.D.
SANITARY MANHOLE TYPICAL DETAIL
Y 0 ADOPTED
��� CITY OF RENTON
STANDARD PLANS
N LST DATE: 12/96
DWG. NAME: BR28 SP PAGE: B071
PROPERTY LINE
z
o FUTURE
6" BUILDING SEWER PIPE I BUILDING SEWER
r�
Li � „
z 2 x 4 STUD SERVICE MARKER PAINT UPPER
TEE WITH 6" SIDE OUTLET -' PORTION WHITE ANS STENCIL ON SIDE
WORDING "SEWER" WITH 3'' HIGH BLACK LETTERS.
AND #6 WIRE WRAPPED AROUND THE STUD AND
6" SIDE SEWER AND BUILDING SEWER a EXTENDED TO THE TOP OF THE STUD.
0
UNLESS OTHERWISE APPROVED BY THE CITY, MAKE TAP THROUGH CAST
IRON SADDLE SECURED TO SEWER MAIN WITH STAINLESS STEEL BANDS
WHEN CONNECTING NEW SIDE SEWERS TO EXISTING MAIN.
60" ALLOWABLE MAX. VITRIFIED CLAY, PLAIN AND REINFORCED CONCRETE, D1 PIPE AND C1
FOR CAST IRON PIPE PIPE SEWER MAINS ARE TO BE CORE DRILLED
OR DUCTILE IRON PIPE.
1 : 3 : 5 MIX tK
CONCRETE
BLOCKING
/ 00 2% _MIN SLOPE
cc
HORIZONTAL
6 SIDE OUTLET TEE
f SEWER MAIN
6" MIN. SEWER MAIN
CONCRETE BLOCKING ANGLE
OF TEE AT MAIN OVER 25 TYPICAL SIDE SEWER ELEVATION
ELEVATION STANDARD SIDE SEWER INSTALLATION
(SEWER MAIN TO PROPERTY LINE)
NOTE: \A Y O ADOPTED
UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2.5' COVER AT PROPERTY �'j` CITY OF RENTON
LINE OR 3-5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER.
STANDARD PLANS
N LST DATE: 12/96
10/17/9 Edited note. DCV I AG
DATE REVISION BY APPR'D DWG. NAME: BR39 SP PAGE: B078
AS-BUILTS
ADAPTER SKIRT
GEOTEXTILE
FABRIC(MIRAFI 70OX U
OR APPROVED EQUAL
SCHEMATIC DETAIL
RETRIEVAL STRAP
OVERFLOW
(TO BYPASS PEAK
FLOWS)
SEDIMENT
ACCUMULATOR
PROVIDE CB INSERT "STREAMGUARD FOR SEDIMENT" OR APPROVED EQUAL
MANUFACTURER'S NAME: FOSS ENVIRONMENTAL
ADDRESS: 200 SW MICHIGAN STREET SEATTLE, WA 98106
TELEPHONE: FOR INFORMATION: (800) 909-3677
CB SEDIMENT PROTECTION
NOT TO SCALE
5-327907
VERTICAL DATUM
NAVD-88
NORTH AMERICAN VERTICAL DATUM OF 1988
PER KING COUNTY DEPARTMENT OF PUBLIC
WORKS
BENCHMARK
THE ELEVATIONS AND CONTOURS SHOWN HEREON
ARE BASED UPON A PROJECT SPECIFIC ASSUMED
DATUM, AND ARE NOT RELATED TO ANY
PUBLISHED VERTICAL CONTROL NETWORK.
SET AN ONSITE TEMPORARY BENCHMARK: NAIL
IN W. SIDE OF PP NEAR NE PROP. CORNER.
ELEVATION = 122.32
FEET.
EQUATION FOR THE CITY OF RENTON DATUM IS
THE RIM OF THE EXISTING SSMH AT 152ND
AVENUE SE & SE 132ND STREET ELEV=458.72
EQUALS 105.98 (CRONES RELATIVE DATUM)
CONTOUR INTERVAL: 2 FEET.
CALL 48 HOURS
BEFORE YOU DIG
1-800-424-5555
SANITARY SEWER NOTES AND SPECIFICATIONS
1. ALL WORK MATERIALS SHALL BE IN CONFORMANCE WITH THE STANDARDS AND
SPECIFICATIONS OF THE CITY OF RENTON UTILITY DEPARTMENT AND THE LATEST EDITION
OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS.
2. THE HOURS OF WORK IN THE STREET RIGHT OF WAY SHALL BE LIMITED TO 8:30
A.M. TO 3:30 P.M. ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE
PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AT 235-2620. ALL STREET CLOSURES,
PARTIAL OR FULL, SHALL BE APPROVED BY THE PLANNING/BUILDING/PUBLIC WORKS
DEPARTMENT 72 HOURS IN ADVANCE. THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND
911 SHALL BE NOTIFIED 24 HOURS IN ADVANCE OF ANY WORK IN THE RIGHT OF WAY.
3. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH "STANDARD SPECIFICATIONS
FOR MUNICIPAL PUBLIC WORKS CONSTRUCTION" PREPARED BY WASHINGTON STATE
CHAPTER AMERICAN PUBLIC WORKS ASSOCIATION, LATEST EDITION (APWA) AND CITY OF
RENTON STANDARD SPECIFICATIONS.
4. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE
THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS
TO AVOID DAMAGE OR DISTURBANCE.
5. A PRECONSTRUCTION CONFERENCE AND A 24 HOUR NOTICE SHALL BE REQUIRED
PRIOR TO STARTING NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S
RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION.
(INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON.) IT
SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE UTILITY DEPARTMENT 24
HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION.
6. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES
OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE
CONSTRUCTION SITE.
7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND
ANY OTHER RELATED PERMITS PRIOR TO ANY CONSTRUCTION.
8. PLANS APPROVED BY THE CITY OF RENTON, PUBLIC WORKS DEPARTMENT, SHALL
TAKE PRECEDENCE OVER ALL OTHER PLANS.
9, A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER
CONSTRUCTION IS IN PROGRESS.
10. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN AS -BUILT
DRAWING OF THE SANITARY SEWER SYSTEM WHICH HAS BEEN STAMPED AND SIGNED BY A
LICENSED PROFESSIONAL ENGINEER OR LICENSED PROFESSIONAL SURVEYOR.
11. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH
A LOOSE AVERAGE DEPTH OF 6 INCHES, MAXIMUM DEPTH OF 8 INCHES, THOROUGHLY
TAMPING EACH LAYER TO 95 PERCENT OF MAXIMUM DENSITY. THESE COMPACTED LAYERS
MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR TO THE SIDE OF
THE TRENCH. MATERIALS TO COMPLETE THE FILL OVER PIPE SHALL BE THE SAME AS
DESCRIBED.
12. OPEN CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXISTING TRAVELED
ROADWAY SHALL BE BACKFILLED WITH CRUSHED ROCK AND MECHANICALLY COMPACTED.
CUTS INTO THE EXISTING ASPHALT SHALL BE NEATLINE CUT WITH SAW IN A CONTINUOUS
LINE. A TEMPORARY MIX PATCH MUST BE PLACED IMMEDIATELY AFTER BACKFILL AND
COMPACTION. A PERMANENT HOT MIX PATCH SHALL BE PLACED WITHIN 10 DAYS AND
SHALL BE PER CITY OF RENTON CURRENT STANDARDS.
13. DATUM SHALL BE CITY OF RENTON, U.S.C. AND G.S.
14. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED
TO THE SATISFACTION OF THE DEPARTMENT FOR THE PREVENTION OF ON -SITE EROSION
AFTER THE COMPLETION OF CONSTRUCTION.
15. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED
FOUNDATION IN ACCORDANCE WITH SECTION 7-02.3(1) OF THE CURRENT STATE OF
WASHINGTON STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION. THIS
SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE
FOUNDATION MATERIAL AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING
MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE
SUPPORTED ON A UNIFORMLY DENSE UNYIELDING BASE. PIPE BEDDING SHALL BE PEA
GRAVEL 6" ABOVE AND BELOW THE PIPE.
16. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER GASKETED
ASTM D 3034, SDR 35, OR DUCTILE IRON CLASS 50.
17. IN UNIMPROVED AREAS, MANHOLE TO EXTEND MINIMUM 6 INCH AND MAXIMUM 18
INCH ABOVE FINISHED GRADE. IN PAVED AREA, COVER MUST SLOPE IN ALL DIRECTIONS
TO MATCH PAVING.
CHECKED FOR COMPLIANCE
TO CITY STANDARDS
Date l0-7_6
Date
Date
I
SCHWEDCL &
� A' scASSOCIATES, PLLC
�F WASH
, ,
t J5p
1
ZONAL
IEXPIRES 09/20/06 1
CIVIL ENGINEERING & PROJECT MANAGEMENT
1945 SOUTH 375TH STREET Bus: (253) 815-1700
FEDERAL WAY, WA 98003 Fax: (253) 815-1701
bsch weiki@comcast.net
ICI-INi,NIN N,AIA
SCANNED OCT 2 7 2006