Loading...
HomeMy WebLinkAboutWWP2703292.1NE 1/4 OF THE NW 1/4 SEC 15 TWN 23 N., RG 5 E. WM Il ••' _ 1�►: LOT STORM SANITARY DRAIN SEWER 1 410.0 404.0 2 410,0 405.5 3 410.0 405.5 4 410.0 405.0 5 410.0 405.0 6 410.0 404.5 S 1/4 SEC 15-23-5 T 1 OF KSCSP �c2�G REC NO. �303160c22 LEGEND LL I t"3 '. 1, 4, v�Q P I FH FIRE HYDRANT nc® Arnecc .�-� I a 8o I I �° Q�� i WV WATER VALVE EXISTING TREE (SIZE & TYPE AS NOTED) EXISTING TREE TO BE REMOVED (SIZE & TYPE AS NOTED) TREE TYPE: A = ALDER C = COTTONWOOD D = DECIDIOUS F = FIR M = MAPLE CR MON #1851 SURFACE '" ® s ..`T;i`t ; ' ' ` ® '-s R BRASS MON WITH °°X�� 9 --— — — — — — ® 93.08 a J l __ — — — _ — --- .3W \ ♦ / l ' 4'] E =` .`� 1~ I I ST'A, 0+5fi 20_—FiT ao i> wi a`r'/ ( % ; fey SAw"s R MH 2 i 402 � , � '; �� � �� I `� J, "RIM 410.00 IE �99.115 N'",,. I — I ! c _! ' I IE=399.5 I' Q �¢ i I �' s `- STA 0+32a 5; RT pper' I SAN SEWER aifl�.,. 1 /� ', '' RIM — ..:08.$0 I U7 ,✓^"� 5 !r%,+, �. ,r '/.,���V 't z'�"i '`� ty,`'/ t.24E'''� t ai cm 00 ww �„ <v b i i .,^; \� y: ' \fit n z vR_._a/T .3- 63/0 w A Q / en m _ e I t / / -. i ..ri..�Sa q 4 - . EN 7:7 'OM dCM k UF 4 i / - .i CD 0.. j / s e Z II t 4^ .,\% e- /, " 4 s r✓ "p p Q _ o B O E 86. "5' " - > e / a .H �, e NO GE PAVEMENT AVEWENT oo W �iwv 2" WADER 'PAIN o tea; , REUSE 8t MATCH EX 35 LF o STORM DRAIN ' — — — — _ �' �- —. — ---- -- —. — _ � — _.... z� �8" PVC SS 0 1.00% (FIELD VERIFY) '� oil Pa 12 WATER MAIN .........— — — ..— ®..d.._ — ...... — . 0+50 +00 N00"38 01 "E 1 +50 2+00 — — "0+o STA 0+00 — CENTER EASEMENT + -± ..... ® STA 0+92.65 - DUVALL AVE NE ...J .....237 LF � 8" PVC SAN SEWER 8" SAN SEWER � i NW COR SEC 15-23-5 r'� DUVALL AVENUE NE ® " SD CR M O N #1503 FOUND mF-�.�...-�--.�.�._,,........;�, �...._�....�..,�.��,..M..�.,�.,._.�µ_„._...w�,..�......�,...�.....�._......���.,. 1/4" PIN IN CONIC MON�— U FFi r WITH CASE (2/17/05) _SAN SEWER i .. .. CB SAN SEWER Rig - t 7,9 L�07 3 Off KSCOP C�77��C0 - IE = 398,66 (S,E) RIM = 407.11 RIM = 405.9 REC NO. 77810M032 IE = 403.3— 12" (S) IE = 395.02N(N.S,W) IE = 403.40 — 12" (E) EXISTING UTILITY LOCATIONS SHOWN HEREON ARE APPROXIMATE ONLY. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE EXACT VERTICAL AND HORIZONTAL LOCATION OF ALL EXISTING UNDERGROUND i UTILITIES PRIOR TO COMMENCING CONSTRUCTION. NO REPRESENTATION IS MADE THAT ALL EXISTING UTILITIES ARE SHOWN HEREON, THE ENGINEER ASSUMES NO RESPONSIBILITY FOR UTILITIES NOT SHOWN OR UTILITIES NOT SHOWN IN THEIR PROPER LOCATION. ;am I k AXA111 Ll I � - - m LY-1 - Civil Engineering and Consulting John J. Pfttman, P.E. 12819 SE 38th Street, #169 Betlevue, WA 9111006 (426) 662-7226 m 10JST ION 44. EXPIRES: 10/14/06 I BASISBASIS OF BEARINGS ' OF NW 1/4 OBENCHMARK F SEC 15-23-05 INTERSECTION NE 4TH STREETOF RENTON MON #1851 SURFACE BRASS • •: Ar •: • 1 REVISED PER CITY COMMENTS JJP 12-6-05 JJP g D' BOYD 5mqL horn 1" = 2 vent 1" = 5' 2 REVISED PER CITY COMMENTS JJP 01-13-06 JJP J,1P 3 REVISED PER CITY COMMENTS JJP 02-21 —06 JJPMIMI TLR ONE INCH CHEMMDo JJP AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY NO. REVISION BY DATE APPR ArPw4 : VERTICAL.' NAVD 1988 HORIZONTAL- NAD 1983/1991 DATUM '\\�F i� ,z CITY OF mJL RENTON Planning/Building/Public Works Dept. nglTogy"ig 1 FOR APPRO BY I BY BY CHECKED FOR COMPLIANCE TO CITY STANDARDS _ a Date r� , Date' MB SHORT PLAT 278 DUVALL AVENUE NE SEWER PLAN 12-2-05 SCANNED MAY i 1 Z006