Loading...
HomeMy WebLinkAboutSWP2703296.7X X X X X X X X X SCALE 20 0 10 20 40 ( FEET ) N Cn 2090 CB TYPE 2 RIM ELEV=296.49 IE 12" CMP (TOP OF FILTER) (N)=292.8 IE 12" CMP (TOP OF FILTER) (SW)=291.7 RESTORE CURB, WALK TO MATCH EXISTING RESTORE MONUMENT TO SURVEYED LOCATION 4' P- CB-1 W J� N 89' 14S" E _ A/C S S 3 NE 23RD ST 0 N R/W 2092 CB TYPE 1 RIM ELEV=292.77 IE 12" CMP (NE)=289.3 IE 12" CMP (W)=289.2 g BHC Consultants, LLC 720 Third Avenue, Suite 1200 Seattle, Washington 98104-1820 m 206.505.3400 YA 206.505.3406 (fax) L rll;t www.bhcconsultants.com x V V) 2093 SSMH RIM ELEV=294.92 IE CENTER=288.5 NE 1 /4, S. 5, T. 23 N., R. 5 E, W.M., 1904 SSMH KING COUNTY, WASHINGTON I I CENTER3 E306.5 i i W 30' F> MIC4 Li z � W Q25' ROW ( R/W SWIMMING POOL PUMP HOUSE RECONSTRUCT, SEE DWG C-5 REPAIR EX ROCKERY BUILD NEW ROCKERY SEE DWG C-5 jfLLLJ � �ty' J A�XY �xrx PLANTER / 4 INSTALL NEW TREES PER e OT 18 BID ITEM, LOCATIONS MAY e 1'f HI( BE ADJUSTED BY CITY RAILROAD r- � SSM RIM ELEV=304. IE CENTER=289. X 3T6" 15' PRIVATE UTILITY ESMT CB-9 FIR RESTORE CRUSHED GRAVEL PAD INSTALL ROLLED ASPHALT CURB APPRX 3" HIGH, MATCH AND TIE INTO EXISTING CURB RECOMMENDED FOR APPROVAL BY -17lGn C±±tZ-2 S•• D8 BY 1906 CB TYPE 1 RIM ELEV=312.12 IE 12" CONC (S)= 1907 YD LID ELEV=306.63 OVERHEAD POWER IE 4" PLASTIC AND TELEPHONE - (SE)=305.9 —� ASPHALT BERM, APPROX 4" HIGH --\ (2)RESTORE EX ASPHALT DITCH — 8ti J0�'• I RESTORE CONC WALK TO MATCH EXISTING 1—STORY HOUSE II #2217 POWER TO PUMP I STEP HOUSE FROM If CORNER OF 1 HOME -- Pone nPAiN —INSTALL NEW TREE .- z i i Ltd i i I 1905 CB TYPE 1 RIM ELEV=314.60 / V) Q w I IE 12" CONC (N)=313.2 L i IE 12" CONC (S)=312.8 0 N z o 4"W STEEL 0 0 ABANDONED z SEE W-3078 Qco 12" CONC t ' 3og A/C CB-6A j IE=305.0 6 MIC7 cn CB-6 7 E 9 ~ 306 \ STA, 0 lw/C 3s\ 1—STORY WOOD HOUSE #2324 6' CHLK ��-1 '— HKzH—RR—T-E S �Psp . A' g2 01 E P0. 0 ID. OPR J0\- CB-8 ASPHALT BERM, APPROX 4" HIGH G 7 RESTORE EX ASPHALT DITCH IE 4" SQUARE PVC=305.3 12" CONC IE=305.1 s !7' o _ A/C ' _ W ' 6 CB-7 CB-7A -- 4"SS, 5.5' Deep ?' Records Show Not Connected �— 2172 SS4H RIM ELEV 304.54 IE CENTER=296.3 15' Utility �smt 'Sewer) STOCKPILE SALVAGED ROCKS AS DIRECTED 41 • Q Q a J 3 F 0 EP �oM6 N E 22 N D ST i — -- -- o W(� p I A/C "DEAD AINTED UTILITY LINE, 1 CB-10�__p UNIDENTIFIED ENS„ t 8"W G STO RUN—OFF P LS IN THIS AREA REMOVE EX PAVEMENT AND GRADE TO DRAIN TO CB SURVEYED SCALE KPG DEMM 1 "=20' /DC oRAr� PLS ONE NM CHECKM JK/DC xr mLsmE F Nor ONE R=4 BY DATE APPR S� ACCOF N LY "0N oc N 89' 13'02" E 1730 SSMH RIM ELEV=309.54 IE CENTER=302.5 GENERAL NOTES: 1. DISTURBED AREAS NOT SHOWN ON PLANS TO BE SEEDED WITH EROSION CONTROL SEEDING OR AS DIRECTED. 2. PROVIDE A MINIMUM OF 12" DEPTH TOPSOIL IN ALL SEEDING AND PLANTING BEDS. 3. ALL SHRUB PLANTING BEDS TO RECEIVE 2" DEPTH BARK MULCH, MINIMUM. CONSTRUCTION NOTES Q1 INSTALL NEW WOOD FENCE TO MATCH EXISTING. 02 RESTORE GATE (WITH SALVAGED EXISTING GATE OR NEW). Q3 PLANT NEW OR SALVAGED TREES, SHRUBS, PLANTS TO MATCH EXISTING LANDSCAPING. RESTORE ALL PLANTING BEDS, TOPSOIL, BEAUTY BARK, ETC. 04 INSTALL NEW SOD OVER ALL DISTURBED GRASS AREAS ON PROPERTY, AND AS DIRECTED BY THE CITY, QS RESTORE GROUND TO MATCH EXISTING SURFACE BY PLACING SILTY SANDY SOIL AND RAKING. 06 RE—ESTABLISH EXISTING GRADE AND FLOW PATTERNS. RESTORE PAVEMENT AS NECESSARY IN ACCORDANCE WITH CITY STANDARD DETAIL H032-1. CITY MAY ADJUST THE EXTENT OF RESTORATION IN THE FIELD. Q7 GRADE TO DRAIN. MA NAw,m ,C1 TY OF NORaoNrN.. NAD ses/,sa, �► RENTON DATUM Planning/Building/Public Works Dept. D-329607 S 72 O �GIST�* T E ssiONAL� � ssl A EXPIRES 10"61 po CALL 3 WORKING DAYS BEFORE YOU DIG 1— 800— 424— 5555 Wm. CITY OF RENTON 07-25-08 DAYTO N AVE NE/NE 22 N D ST FRIONM DRAINAGE IMPROVEMENT PROJECT ORJgMiiO N0: LANDSCAPING/RESTORATION PLAN C-4 ".. 7 ' 8