HomeMy WebLinkAboutTED4003310.3CCERA L A/ 0 TES CD 0 0 1, BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A Y 6 `D PRE -CONSTRUCTION MEETING MUST BE HELD WITH THE CITY OF 8 3 o W RENTON PUBLIC WORKS, DESIGN ENGINEER. o Q a 000 N 2. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST EDITION a z OF STANDARD SPECIFICA TIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION PREPARED BY WS.D.0 T., AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA), AS AMENDED BY THE CITY OF RENTON DEPARTMENT OF PUBLIC WORKS. (� Lj Q 3, THE STORM DRAIN SYSTEM SHALL BE �nfYc RUCTED ACCORDING THE APPROVED PLANS WHICH ARE ON FILE IN THE DEPARTMENT OF PUBLIC L, WORKS ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE WRITTEN APPROVAL FROM THE CITY OF RENTON DEPARTMENT OF _T Z P/ /B/ /C ,wnwS nESIGAI EIVGINEEP OF, STORM WA TE,R UTILITY ❑ Q 4. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE C:) WHENEVER CONSTRUCTION IS IN PROGRESS Fes-- f - - c"� 5. DA TUM SHALL BE U. S G. S. UNLESS OTHERWISE APPROVED BY THE CITY OF RENTON DEPARTMENT OF PUBLIC WORKS REFERENCE BENCHMARK O AND ELEVA TIONS ARE NOTED ON THE PLANS 6. ALL SEDIMENTA TION/EROSION FA CILI TIES MUST BE IN OPERA TION O Z PRIOR TO CLEARING AND BUILDING CONSTRUCTION, AND THEY MUST W BE SA TISFACTORIL Y MAINTAINED UNTIL CONSTRUCTION IS COMPLETED AND THE POTENTIAL FOR ONSITE EROSION HAS PASSED. i 7 ALL RETENTION/DETENTION FACILITIES MUST BE INSTALLED AND IN 0 OPERATION PRIOR TO OR IN CONJUNCTION WITH ALL CONSTRUCTION z ACTIVITY UNLESS OTHERWISE APPROVED BY THE DEPARTMENT OF w PUBLIC WORKS, STORM WA TER UTILITY Q 3. GRASS SEED MAY" BE APPLIED BY HYDROSEEDING THE GRASS SEED MIXTURE, OTHER THAN CITY OF REN TON APPROVED STANDARD MIXES, Z N SHALL BE SUBMITTED BY A LANDSCAPE ARCHITECT AND APPROVED BY THE DEPARTMENT OF PUBLIC WORKS, STORM WATER UTILITY: W W 9ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY Q v RRLID 1RE0 I UU1vinATiu1vl I/v' ACCORDA/v'CE rvIllf SELi%l/ON 7 02.3(1� OF Z u, THE CURRENT S TA TE OF WASHING TON STANDARD SPECIFICATION FOR J ROAD AND BRIDGE CONSTRUCTION THIS SHALL INCLUDE NECESSARY fl LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION N AA4 TERIAL AS WELL AS THE PLACEMENT AND COMPACTION OF REQUIRED z N BEDDING MA TERIAL TO UNIFORM GRADE SO THA T THE ENTIRE LENGTH z , OF THE PIPE WILL BE SUPPORTED ON A UNIFORML Y" DENSE UNYIELDING a BASE. ALL PIPE BEDDING SHALL BE APWA CLASS "C', WITH THE EXCEPTION OF PVC PIPE. ALL TRENCH BACKFILL SHALL BE COMPACTED TO MIN. 959 FOR PA VEMENT AND STRUCTURAL FILL AND 907, OTHERWISE PER ASTM D-1557-70. PEA GRA VEL BEDDING SHALL McoBE 6" UNDER AND OVER P. V. C. PIPE00 I", � o> z = Q 0 U O 0 10. GAL VANIZED STEEL AND ALUMINIUMIZED STEEL PIPE FOR ALL DRAINAGE FACILITIES SHALL HA VE ASPHAL T TREA TMENT #I OR BETTER INSIDE AND OUTSIDE. ? 1. STRUCTURES SHALL NOT BE PERMITTED WITHIN 10' FEET OF THE SPRING LINE OF ANY STORM DRAINAGE PIPE, OR 15' FEET FROM THE TOP OF ANY CHANNEL BANK. 12. ALL CA TCH BASIN GRA TES SHALL BE DEPRESSED 0. 10' FEET BELOW PA VEMENT LEVEL. 13. OPEN CUT ROAD CROSSINGS THROUGH EXISTING PUBLIC RIGHT-OF-WAY WILL NOT BE ALLOWED UNLESS SPECIFICALLY APPROVED BY THE CITY' OF RENTON DEPARTMENT OF PUBLIC WORKS, DESIGN ENGINEER. 14, ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A DEPTH OF I' FOOT AND MUST MEET THE FOLLOWING SPECIFICA TIONS.- Q"_R'� an%7n% PASSinI� ?"_4" RnCw/3n%4n7 PAcSIAir-- AAln _y' ROCK/109-209 PASSING. 15. ALL BUILDING DOWNSPOUTS AND FOOTING DRAINS SHALL BE CONNECTED TO THE STORM DRAINAGE SYSTEM, UNL FSS APPROVED BY THE DEPARTMENT OF PUBLIC WORKS, DESIGN ENGINEER OR STORM WA TER UTILI TY AN ACCURA TEL Y DIMENSIONED CERTIFIED "AS -BUILT" DRAWING OF THIS DRAINAGE SYSTEM WILL BE SUBMITTED TO THE CITY OF RENTON UPON COMPLETION. 16. ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMIT BY THE CITY OF RENTON DOES NOT RELIEVE THE OWNER OF THE CONTINUING LEGAL OBLIGATION AND/OR LIABILITY CONNECTED WITH STORM SURFACE WA TER DISPOSITION FURTHER, THE CITY OF RENTON DOES NOT ACCEPT ANY OBLIGA TION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE SYSTEM PROVIDED DURING CONSTRUCTION. 17. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARD, SAFETY DEVICES, PROTECTIVE EQUIPMENT FLAGGERS, AND AN Y 0 THER NEEDED A C TIONS TO PRO TEC T THE LIFE HEAL TH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION Wi TH THE PERFORMANCE OF WORK COVERED BY THE CONTRACT ANY WORK WI THIN THE IRA VELED RIGHT -OF- WA Y THA T MA Y INTERRUP T NORMAL TRAFFIC FLOW SHALL REQUIRE AN APPROVED TRAFFIC CONTROL PLAN BY THE TRAFFIC ENGINEERING DI V OF THE DEPAR IME,N T OF PUBLIC WORKS. ALL SECTIONS OF THE W. S D. O. T STANDARD SPECIFICATIONS 1-07-23, TRAFFIC CONTROL, SHALL APPL Y 18. SPECIAL DR #V4GE MEASURES WILL BE REQUIRED IF THE PROJECT LOCATION IS WITHIN THE AQUIFER PROTECTION AREA. 0 FRAME AND GRATE 0 0 W W � 2 3 W Y w O 0 O asa V) U Q a Q W 0 z 0 w ry I - #3 BAR HO 5 s�. 2 S -- 5 � OP 6" 2 - #3 BAR HOOP ,' 0 Ik BAR EACH CORNET #3 BAR EACH SIDi I #3 BAR EACH WA Y _ CATCH BA SIN zl 4" MIN CL A * 2" CLA OR 6" RISER SECTION NO TES. 1. CATCH BASIN TO BE CONSTRUCTED IN ACCORDANCE WITH ASTM C 478 (AASHTO M 199) & ASTM C 890 UNLESS OTHERWISE SHOWN ON PLANS OR NOTED IN THE STANDARD SPECIFICATIONS 2 AS AN ACCEPTED ALTERNATE TO REBAR, WELDED WIRE FABRIC HAVING A MINIMUM AREA OF 0. 12 SQUARE INCHES PER FOOT MAY BE USED, WELDED WIRE FABRIC SHALL COMPLY TO ASTM A 497 (AASHTO M 221), WIRE FABRIC SHALL NOT BE PLACE IN THE KNOCKOUTS. 12 " RISER SECTION 3, THE BO T TOM OF THE PRECAST BASE SECTION MAY BE ROUNDED. 4, PRECAST BASES SHALL BE FURNISHED WITH CUTOUTS OR KNOCKOUTS. KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM. 5_ KNOCKOUTS MAY BE ON ALL 4 SIDES WITH MAXIMUM DIAMETER OF 20''- KNOCKOUTS MAY BE EITHER ROUND OR ' D " SHAPE. PIPE TO BE INSTALLED /N FACTORY SUPPLIED KNOCKOUTS. 6, KAIn KOflTS OR l;fITOILT HOLE .SIZE IS EQl/AL TQ P/PE OIJTER DIAMETER PLUS CATCH BASIN WALL THICKNESS. 7 THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO THE PIPE INVERT IS 5'- 0'° 8. THE TAPER ON THE SIDES OF THE PRECAST BASE SECTION AND RISER SECTION SHALL NOT EXCEED 1/2"/FT PRECAST BASE SECTION (MEASUREMENT AT THE TOP 9 CATCH BASIN FRAME AND GRATE SHALL BE IN ACCORDANCE WITH OF THE BASE) STANDARD SPECIFICATIONS AND MEET THE STRENGTH REQUIREMENTS OF FEDERAL SPECIFICATION RR-F-621D. MATING SURFACES SHALL BE FINISHED TO ASSURE NON -ROCKING FIT 10. FRAME AND GRATE MAY BE INSTALLED WITH FLANGE DOWN OR CAST INTO ,RISER,. T YPE I — 6.5' MIN. - I 2.5' ,'I. Mlk j. k� 6.5' MIN, —� I 1 1 2.5' I+N MIN /,*/N ?F CURB OR >F PA VEMEN T 2" CLASS B' *ACP CLASS 'E' OR B' 6" CRUSHED SURFACING TOP COURSE 'ER LINE OR CRUSHED ROCK, LINE FLOWABLE FILL, OR AS REQUIRED BY ENGINEER. I 0.5 M//V. " 2 " DEP TH OF GRIND OR SA WCU T AND REMOVE TYPICAL PA TCH FOR FLEXIBLE PA VEMEN T WHEN PERPENDICULAR TO ROAD WA Y CEN TER LINE DWG. #HR-23 SEE OVERLAY DETAIL FOR MIN PAVING STANDARDS, OR RENTON DWG# HR-05 FOR MIN. STANDARDS. RIGHT OF WAY PA VING 12" & LARGER STORM PIPES PER PLAN. w CATCH BASIN W W v (5' SIDEWALK IWHERE SPEC- IFIED ON PLAN L. f'L �! lV VIE VV N. T S. RIGHT OF WAY z ti _2MIN W CO VER v O 6 " TEE 6" PVC - CURB LANE Jr MARKING OR FOG lNE H. cl o SSIONAL �� "AS -BUILT" NOTE. IEXPIRES 6/22/07 "AS -BUILT" IS BASED ON A ACTUAL FIELD SURVEY BY TOLIMA ENGINEERS AND INFORMATION SUPPLIED BY CONTRACTOR. // I' I' Ir E' OR B' * L2" CLASS "B" MIN. 2" SAWCUT AND REMOVE OR GRIND, SEAL WI TH AR400OW Q v i SAW CUT AND REMOVE /_ EXISTING A. C. PA VING. MIN. 6" CR[1 SHED SURFACING TOP COURSE EDGE PA VEMEN T, EDGE CURB & GU TTER, 3— i-. re rr — 3— r e rn r UK ULIV ILn Ur LANL L11VL MIN. *MINIMUM ACP CLASS 'E' SHALL BE. CRUSHED ROCK, FLOWABLE FILL **PRINCIPAL/,"/"^JOR� OR A S DIRECTED B Y ENGINEER CVLLEI�TVR ARTERIAL STREETS & INDUSTRIAL ACCESS STREETS - 6" ACP CLASS 'E' OR 'B' RESIDETIAL ACCESS STREET - 2" ACP CLASS 'E' OR 'B' NOTE. UPON REQUEST OF ENGINEER, NEW ROADWAY PAVEMENT SECTION MAY BE DESIGNED USING AN APPROVED METHOD FOR DWG. #HR-05 DETERMINING PAVEMENT THICKNESS. L A NE WI D TH 0 VERL A Y I OR FLEXIBLE PA VEMEN T NOTE: / , FINISHED GRADE ALL 6" & 8" ADS (OR RIGID PVC) PIPE SHALL BE PLACED A T A MIN. SL OPE OF 1. 0% OR GREATER & INCLUDE A BURIAL LOCH TOR WIRE. CONTRACTOR HAS OPTION OF USING 6" CAP W/THREADED EITHER ADS OR PVC PIPE PER K. C.R. S. 7.04 PLUG 6" PVC LENGTH REQUIRED 10' OR AS OTHERWISE 118" BEND (6") SHOWN ON PLAN, 6" PVC- 10' - C Loln �6" PVC COLLECTOR PIPE (OR 8 " P VC IF SPECIFIED ON PLAN",) EL E VA Tl ON VIE W NTS. 2 X 4 STAKE MARKED /c-MIDAd no nDA/A0 (.)ivivvi vn 1_1n,'lf1vj __CAP 6" ADS & SECURE TO STAKE WITH 16 ga. COPPER WIRE _SWEEP FLEXIBLE ADS PIPE TO SURFA CE. INVERT ELEVATION AS SPECIFIED ON PLAN. ROOF & FOOTING DRAIN DETArL NO SCALE 2"x4" POST MARKED "DRAIN" EXTENSION OF6"PVC OR CAP END `6"X6"WYE TYPICAL CLEANOUT DETAIL N.TS. FOR IOT DRAINAGE TO BE TIED TO STORM DRAIN SYSTEM. PLACE CLEANOUTS BY FRONT LOT CORNERS AND "Y 'S" IN THE PIPES. H. EX6/22/07 1 RECOMMENDED FUR APPROVAL BY DATE�� BY" DATE BY DATE BY DATE BY DATE oPAMW NO:. 898001 SITE. DWG SHEET ` OF; 4 T�Fl RM Ag : 3�U3 07