Loading...
HomeMy WebLinkAboutWWP2703340.80 U 0 z m 0 In w 2 z' a a w x x w J U- n n n V W W ry U Cn J Zo = Z O W o N 3' MIN. 6" BUILDING SEWER PIPE Z TEE WITH 6" SIDE OUTLET J W O a 6" SIDE SEWER AND BUILDING SEWER PROPERTY LINE 6' FUTURE BUILDING SEWER k 4" STUD SERVICE 'HINT UPPER PORT70N WHITE ;NS STENCIL ON SIDE WORDING SEWER" WITH 3" HIGH BLACK ETTERS. AND 16 WIRE WRAPPED ;ROUND THE STUD AND EXTENDED '_0 THE TOP OF THE STUD. UNLESS OTHERWISE APPROVED BY THE CITY, MAKE TAP THROUGH CAST IRON SADDLE SECURED TO SEWER MAIN WITH STAINLESS STEEL BANDS WHEN CONNECTING NEW SIDE SEWERS TO EXIS77NG MAIN. VITRIFIED CLAY, PLAIN AND REINFORCED CONCRETE D1 PIPE AND Cl PIPE SEWER MAINS ARE TO BE CORE DRILLED 60" ALLOWABLE MAX. uj UNLESS OTHERWISE SHOWN ON PLAN, SIDE FOR CAST IRON PIPE 1: J. 5 MIX CONCRETE SEWER SEWER SHALL HAVE A MINIMUM 2.5' COVER �! OR DUCTILE IRON PIPE. ��E QGK AT PROPERTY LINE OR 3-5' LOWER THAN �THE BLOCKING LOWEST HOUSE ELEVA770N, WHICHEVER r6"SIDE MPNGRE !S LOWER. CO 2X MIN SLOPE OUTLET TEEHORIZONTAL6" MIN. SEWER MAIN MAIN CONCRETE BLOCKING ANGLE TYPICAL SIDE SEWER ELEVATION H A OF TEE AT MAIN OVER 25 ELEVATION Nd STANDARD SIDE SEWER INSTALLATION DETAIL 0 NOT TO SCALE CITY OF RENTON DWG. NAME: BR39 SP PAGE. B078 U P. CAS77NG INLAND FDRY OR EQUAL. PT1714 z SEE DETAIL 5.1.4. 6" ADJUSTMENT (4" MIN.) 25" 12" MAX. TCONE z O O U < ry n n 4 0 3 �f b m � Q Q � ro o r m 3 b 0 in bl b h .J a Q a 3 O Z O r) o > W ry w 0 4 w g 4 0 N 0 0 0 �Q o ��^ O J o Z 21 " I MORTAR JOINTS " MIN. 6-1/2" 7' MIN. 48" OR APPROVED EQUAL. 12" (TYP) MAX. PIPE SIZE - 21 " I.D. LADDER -STD. ALUMINUM OR GALVANIZED STEEL MORTAR s FILLET De CONCRETE SHELF a " PRECAST BASE SECTION OR CAST IN SHELF. 6" MIN. � DP I D -- 6" MIN. NOTE, SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES, INCLUDING CHANNELING, COATED (SEALED) WITH A HIGH SOLIDS URETHANE COA77NG; WASSER MC-CONSEAL OR APPROVED EQUAL; COLOR OF COATING SHALL BE WHITE SANITARY MANHOLE TYPICAL DETAIL NOT TO SCALE CITY OF RENTON DWG. NAME. • BR28 SP PAGE. B071 PORTION OF SW 1/4, NE 1/4 SEC. 15, TWP. 23 N., RGE. 5 E., W.M. J�4" SQUARES SPACED - 3 4" AS /ND/CATED -HT 1/8" ❑ El �1/2" 2' ❑❑❑❑❑ _ ❑ } cnnlr.RFTF RA/SE- WlDE B! SANITARY SEWER CLEANOUT DETAIL NOT TO SCALE CITY OF RENTON DWG. NAME: BW18B SP PAGE. B076 1/2" DIA BLIND FLANGE AS DAM 2 8" DI TEE (MJ) NEW 8" (IN) EX. SSMH 8858 KOR-N-SEAL CONNECTOR CORE DRILLED NOTE.' N MJ TEE AND BEND Z JSHALL OINTS HAVE RESTRAINT ¢ 5/8" ANCHOR BOLTS 1�__RELINPEIR STAINLESS STEEL A -+ CLAMNG BRACKETS OR AP EX. 12" !E 390.07 (OUT) p Z 8" DI 4" MAX. 8"x90' BEND MJxPE ENCASE IN CONCRETE a ° s CHANNELIZE SHELF MIN. 2" DEEP oO o o a o� c� eca 8" IE 390.82 0 000 0 o O Oo NOTES• 1. DROP TEE TO BE INSTALLED M/NIMUM OF 3' BELOW CONE SECTION 2. INSIDE DROP MANHOLE SHALL BE INSTALLED ONLY WHERE APPROVED BY 7HE CITY J. INSIDE DROP /S ONLY ALLOWED ON EXISTING MANHOLES. 4. CORE DRILL OPENINGS FOR NEW PIPE. 5. RECHANNEL BASE Wl7H 3000 PSI CONCRETE HEIGHT OF CHANNELS SHALL BE NO LESS THAN 3/4 OF PIPE DIAMETERS. 6. RELINER STAINLESS STEEL ADJUSTABLE CLAMPING BRACKETS OR APPROVED EQUAL SHALL BE INSTALLED WITHIN 6" OF B077-1 BELL AND SPIGOT ENDS OF EACH DROP PIPE. IF DROP PIPE LENGTH EXCEEDS 5 FEET THEN CENTER STRAPS SHALL BE INSTALLED KITH A MINIMUM SPACING OF 4 FEET ON CENTER. BRACKETS SHALL BE ATTACHED UTILIZING STAINLESS STEEL EXPANSION BOLTS, MIN. 2 EACH AT CONNECTI0N POINTS INSIDE DROP SANITARY MANHOLE DETAIL SANI TAR Y SEWER NO TES AND SPECIFICATIONS: 1. ALL WORK MATERIALS SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON AND THE LATEST EDI77ON OF THE WSDOT/APWA STANDARDS AND SPECIFICA T70NS. 2. THE HOURS OF WORK IN THE STREET RIGHT-OF-WAY SHALL BE LIMITED TO 8:30 AM TO 3.•30 PM ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE TRANSPORTATI0N DIVISION AT 277-6222. ALL STREET CLOSURES, PAR77AL OR FULL, SHALL BE APPROVED BY THE TRANSPORTATION DIVISION 24 HOURS IN ADVANCE THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911 SHALL BE N077FIED 24 HOURS IN ADVANCE. J. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE "STANDARD SPECIFICATIONS FOR MUNICIPAL PUBLIC WORKS CONSTRUCTION" PREPARED BY WASHINGTON STATE CHAPTER AMERICAN PUBLIC WORKS ASSOCIATION, LATEST EDIT70N (APWA) AND CITY OF RENTON STANDARD SPECIFICATIONS. 4. ALL LOCAT70NS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCAT70N SO AS TO AVOID DAMAGE OR DISTURBANCE. 5. A PRECONSTRUCT70N CONFERENCE AND A 24-HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONS7RUCTION. (INSPECTION WILL BE ACCOMPLISHED BY A REPRESEN TA T7 VE OF THE CITY OF RENTON.) IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO N077FY THE CITY INSPECTOR 24 HOURS IN ADVANCE OF BACKFILLING ALL CONS77?UC770N. 6. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCT70N AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE NOT TO SCALE 7 IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO ANY CONSTRUCTION. 8. PLANS APPROVED BY THE CITY OF RENTON, DEVELOPMENT SERVICES DIVISION, SHALL TAKE PRECEDENCE OVER ALL 07HER PLANS 9. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTI0N IS IN PROGRESS. 10. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN AS -BUILT DRAWING OF THE SANITARY SEWER SYSTEM WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER OR LICENSED PROFESSIONAL SURVEYOR. 11, BACKFILL SHALL BE PLACED EQUALLY ON 807H SIDES OF THE PIPE IN LAYERS WITH A LOOSE AVERAGE DEP774 OF 5 INCHES, MAXIMUM DEPTH OF 8 INCHES, THOROUGHLY TAMPING EACH LAYER TO 95 PERCENT OF MAXIMUM DENSITY. THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR TO THE SIDE OF THE TRENCH. MATERIALS TO COMPLETE THE FILL OVER PIPE SHALL BE THE SAME AS DESCRIBED. 12. OPEN CUT ROAD CROSSINGS FOR U77LITY TRENCHES ON EXIS77NG TRAVELED ROADWAY SHALL BE BACKFILLED WITH CRUSHED ROCK AND MECHANICALLY COMPACTED. CUTS INTO THE EXIS77NG ASPHALT SHALL BE NEATLINE CUT WITH SAW IN A CONTINUOUS LINE. A TEMPORARY MIX PATCH MUST BE PLACED IMMEDIATELY AFTER BACKFILL AND COMPACTION. A PERMANENT HOT MIX PATCH SHALL BE PLACED WITHIN 10 DAYS AND SHALL BE PER CITY OF RENTON CURRENT STANDARDS. 1/2" WEB 8 PL. 1 2" x 3" x 3 8" NON-SKID PATTERN CAST INTEGRAL ON TOP 1 " SEAT SECT/ON A -A FRAME (NON -LOCKING) COVER (NON -LOCKING) FOR 5/8"-11 N.C. x 1-1/4" 5/8" 3/8" A B S.S. SOC. HD. CAP SCREW (3 REQD.) 1/2" (TYP) TYPICAL NON-SKID 1-7 8' 0 PATTERN o) ` (i TYP) (0 14 J Li J o B 25" SECTION B-B � �- UNDERSIDE SHOWN FOR CLARITY CORE (TYP.) ON 23" B.C. AND TAP 5/8 "-11 N.C. 1-1/2" CORE(TYP.) (LOCKING) ON 23" B.C. (TYP. 3 PL.) NOTES. • FRAME (LOCKING) COVER 1. FOR NON -LOCKING USE OLYMPIC FOUNDRY No. MH 30 OR EQUAL. 2. FOR LOCKING LID USE OLYMPIC FOUNDRY No. MH 30 D/T OR EQUAL. J. USE FRAME AND COVER FOR STORM (SPECIFY "DRAIN" ON COVER), SANITARY (SPECIFY ` SEWER' ), OR WATER (SPECIFY "WATER"). MANHOLE FRAME AND COVER DETAIL NOT TO SCALE CITY OF RENTON DWG. NAME: BR29 W (SEE NOTE 4 LIMITS OF PIPE ZONE BACKFILL MATERIAL i (SEE NOTE 5) 6" CONCRETE CLASS C BEDDING MATERIAL (SEE NOTE 8) C FLEXIBLEFOR PIPE FOUNDATION LEVEL 1 i (SEE NO 7) ° -�- °e �A 8 FOUNDA T70N LEVEL (CLASS A DESIGN) W (SEE NO1E 4J� LIMITS OF PIPE ZONE BACKFILL MATERIAL TABLE (SEE NOTE 5) 6„ ED EQUAL BEDDING MATERIAL SP PAGE: B074 W (SEE NOTE 4) LIMITS OF PIPE ZONE I 1' B A (CLASS F DES/ BEDDING FOR FLEXIBLE PIPE FOR RIGID PIPE C NOTES, (SEE NOTE 6) 1. PROVIDE UNIFORM SUPPORT UNDER BARREL. FOUNDATION LEVEL 2 HAND TAMP UNDER HAUNCHES TA B 3. COMPACT BEDDING MATERIAL TO 95% MAX. DENSITY EXCEPT DIRECTLY OVER PIPE. HAND TAMP ONL Y. (CLASS B. C. D, DES/GN! 4. SEE 'EXCAVAT70N AND PREPARAT70N OF TRENCH" 1N THE SANITARY SEWERS SECT70N BEDDING FOR RIGID PIPE OF THE STANDARD SPECIFICTA77ONS FOR TRENCH WDTH "W" AND TRENCHING OPTIONS. 774E PIPE ZONE WILL BE THE ACTUAL TRENCH WIDTH, EXCEPT FOR CLASS A BEDDING THE MINIMUM CONCRETE WIDTH SHALL BE 1-1/2 / D + 18" BEDDING CLASS DESIGN DIMENSION CLASS A CLASS B CLASS C CLASS D CLASS F A 4" MIN, 1/41.D. 12" MAX. • • ZERO • B 1/4 O.D. 1/2 O.D. 1/8 O.D. ZERO O.D. C 3/4 O.D. 1/2 O.O. 1/8 O.D. O.D. - 5. TRENCH BACKFILL SHALL CONFORM TO "BACKFILLING SEWER 7RENCHES" IN THE SANITARY SEWERS SECTION OF THE STANDARD SPEC/F/CAPONS, EXCEPT THAT ROCKS OR LUMPS LARGER THAN 1" PER FOOT OF PIPE DIAMETER SHALL NOT BE USED IN THE BACKFILL MATERIAL. 6. SEE "BEDDING MATERIAL FOR RIGID PIPE" IN 7HE AGGREGATES SEC77ON OF 7HE STANDARD SPECIFICA 77ONS FOR THE MATERIAL SPECIFICA TONS. 7. SEE BEDDING MATERIAL FOR FLEXIBLE PIPE" IN THE AGGREGATES SECT70N OF STANDARD SPECIFICAT70N FOR THE MATERIAL SPECIFICATIONS 8. PIPE MUST BE ANCHORED /N SUCH A MANER AS TO ENSURE FLOW LINE IS MAINTAINED. * A = 4" MIN. 27" I.D. AND UNDER 6" MIN. OVER 27" I.D. PIPE BEDDING FOR SANITARY SEWERS NOT TO SCALE CITY OF RENTON DWG. NAME: BW18C SP PAGE.B077 13. DATUM SHALL BE CITY OF RENTON, NAD 198311991 & NAVD 1988. 14. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED TO THE SATISFACTION OF THE DEPARTMENT FOR 774E PREV/ENT70N OF ON -SITE EROSION AFTER THE COMPLET70N OF CONSTRUCTION. 15. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERTY PREPARED FOUNDATION IN ACCORDANCE WITH SECT70N 7-02.3(1) OF THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR 7HE TOP OF THE OF 77-IE FOUNDATI0N MATERIAL AS WELL AS PLACEMENT AND COMPACTI0N OF REQUIRED BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE EN77RE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE UNYIELDING BASE. PIPE BEDDING SHALL BE PEA GRAVEL 6 INCHES ABOVE AND BELOW THE PIPE. 16. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER GASKETED ASTM D 3034, SDR 35, OR DUCTILE IRON CLASS 50. 1 Z IN UNIMPROVED AREAS, MANHOLE TO EXTEND MINIMUM 6 INCHES AND MAXIMUM 18 INCHES ABOVE FINISHED GRADE. IN PAVED AREAS, COVER MUST SLOPE IN ALL DIREC77ONS TO MATCH PAVING. s•�oia AS -CONSTRUCTED PLANS (SEE SHEET 1 FOR STATEMENT) Checked for Compliance to City Standards ®2007 TRIAD ASSOCIATES Ab.5-334DIb Umm ar"ur TRIAD ASSOCIATES 12112 115th Ave. NE Kirkland, WA 98034-6923 425.821.8448 425.821.3481fax 800.488.0756 toll free www.triadassoc.com Z Q Z v p v < M < 2 o m ~ 0 A a � O Z � a v V O U ?__ h U PQ a Q A � a co z MICHAEL L. MATHESON, PE PROJECT MANAGER NICK A. PINCER, PLS PROJECT SURVEYOR MICHAEL A. MOODY, PE PROJECT ENGINEER UFFREY L. COY, ASLA PROJECT LANDSCAPE ARCHITECT FIRST SUBMITTAL DATE: 7119106 SCALE: HORIZ.: N/A VERT.:N/A 41843IST �s IONALR���~ EXPIRES: 3/19/ STAMP NOT VALID UNLESS SIGNED AND DATED JOB N0. 03_ 185 5riL'EI r4u. 34 OF 36