HomeMy WebLinkAboutWWP2703358.5m i. o co CQ � W V.I -4 C� C-5 � I I Q J � � I w � � I I, W �T4 � I L +; a� a� v ® p E Q V W �W _ \c 5 E m W: WIN C � tL 0 d Q w Q z 0 w x O z SANITARY SEWER NOTES 1, ALL WORK MATERIALS SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATION OF THE CITY OF RENTON UTILITY DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, 2. ALL CONSTRUCTION SHALL BE ACCORDANCE WITH "STANDARD SPECIFICATIONS FOR MUNICIPAL PUBLIC WORKS CONSTRUCTION" PREPARED BY WASHINGTON STATE CHAPTER AMERICAN PUBLIC WORKS ASSOCIATION, LATEST EDITION (APWA) AND CITY OF RENTON STANDARD SPECIFICATIONS. 3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. 4. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE. 5. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO ANY CONSTRUCTION. 6. PLANS APPROVED BY THE CITY OF RENTON, PUBLIC WORKS DEPARTMENT SHALL TAKE PRECEDENCE OVER ALL OTHER PLANS. 7. A COPY OF THESE PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 8. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN AS -BUILT DRAWING OF THE SANITARY SEWER SYSTEM WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER OR LICENSED PROFESSIONAL SURVEYOR, 9. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A LOOSE AVERAGE DEPTH OF 6 INCHES, MAXIMUM DEPTH OF 8 INCHES, THOROUGHLY TAMPING EACH LAYER TO 95 PERCENT OF MAXIMUM DENSITY. THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR TO THE SIDE OF THE TRENCH. MATERIALS TO COMPLETE THE FILL OVER PIPE SHALL BE THE SAME AS DESCRIBED. 10. OPEN CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXISTING TRAVELED ROADWAY SHALL BE BACKFILLED WITH CRUSHED ROCK AND MECHANICALLY COMPACTED, CUTS INTO THE EXISTING ASPHALT SHALL BE NEAT LINE CUT WITH SAW IN A CONTINUOUS LINE, A TEMPORARY MIX PATCH MUST BE PLACED IMMEDIATELY AFTER BACKFILL AND COMPACTION, A PERMANENT HOT MIX PATCH SHALL BE PLACED WITHIN 10 DAYS AND SHALL BE PER CITY OF RENTON CURRENT STANDARDS. 11. DATUM SHALL BE CITY OF RENTON, 1988 NAVD. 12. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED TO THE SATISFACTION OF THE DEPARTMENT FOR THE PREVENTION OF ON -SITE EROSION AFTER THE COMPLETION OF CONSTRUCTION. 13. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH SECTION 7 OF THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE UNYIELDING BASE. PIPE BEDDING SHALL BE PEA GRAVEL 6 INCHES ABOVE AND BELOW THE PIPE. 14. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER GASKETED ASTM D 3034, SDR 35, OR DUCTILE IRON CLASS 50. 15. IN UNIMPROVED AREAS, MANHOLE TO EXTEND TO MINIMUM 6 INCHES AND MAXIMUM 12 INCHES ABOVE FINISHED GRADE. IN PAVED AREA, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING. MORTAR FILLET MANHOLE FRAME AND COVER SEE DRAWING BR29 NOTES: ADJUSTMENT (4" MIN.) 1. STEPS TO BE 3/4" 4 DEFORMED BAR GALVANIZED SAFETY STEPS OR EQUAL CONE 2. STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS ARE INSTALLED. 3. CASTING TO BE PER DRAWING BR29. RUBBER GASKETED JOINTS 4. MANHOLE SECTIONS TO BE OF REINFORCED PRE -CAST IN ACCORDANCE WITH ASTM C-443 CONCRETE. 5. ALL JOINTS SHALL BE GROUTED. STEPS - 3/4" DEFORMED BAR 6. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR STEPS SHALL BE INCLUDED SURFACES, INCLUDING CHANNELING, COATED (SEALED) WITH A HIGH SOLIDS URETHANE COATING; CONCRETE RISER BY PIPE INC., WASSER MC-CONSEAL OR APPROVED EQUAL; OR APPROVED EQUAL. COLOR OF COATING SHALL BE WHITE. 7. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE WITH ASTM C-443. 8. CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 THE INSIDE DIAMETER OF THE LARGEST PIPE. MAX. PIPE SIZE - 21" I.D. 9. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK ADAPTER, KOR-N-SEAL BOOTS OR APPROVED EQUAL. LADDER -STD. ALUMINUM OR GALVANIZED STEEL CONCRETE SHELF PRE -CAST BASE SECTION OR CAST IN SHELF. SANITARY MANHOLE TYPICAL DETAIL NOT TO SCALE NOTE: A "FALL RESTRAINT" DEVICE IS REQUIRED ON ALL MANHOLES GREATER THAN 20 FEET IN DEPTH. TYPE "SURETRACK" LADDER CLIMBING SYSTEM OR APPROVED EQUAL. SANITARY MANHOLE TYPICAL DETAIL Y_ ADOPTED DCv AG 'n CITY OF RENTON - - - DCV AG BY APPR'D STANDARD PLANS LST DATE:12/96 DWG. NAME: BR28 SP PAGE: B071 10/17/96 EDITED TEXT 3/8/95 ADDED NOTE, EDIT TEXT DATE REVISION 24"x 6" FRAME AND LIP PER DRAWING BR29. IN 4" MIN. TO 12" MAX. 00 24'' �¢ E 12" o C\2 F, a. 1• 4 4 54 y4 v ­4 •s " :. e. :. :•.. 6AL h- 6"- so's515601T NOTES: 1. STEPS TO BE 3/4" 0 DEFORMED BAR GALVANIZED SAFETY STEPS OR EQUAL. 2. STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS ARE INSTALLED. 3. CASTING TO BE PER DRAWING BR29 4. MANHOLE SECTIONS TO BE OF REINFORCED PRECAST CONCRETE. 5. OPENING SHOULD BE ON DOWNSTREAM SIDE. 6. ALL JOINTS SHALL BE GROUTED. 7. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES, INCLUDING CHANNELING, COATED (SEALED) WITH A HIGH SOLIDS URETHANE COATING; WASSER MC-CONSEAL OR APPROVED EQUAL; COLOR OF COATING SHALL BE WHITE. 8. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE WITH ASTM C-443. 9, CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 THE INSIDE DIAMETER OF THE LARGEST PIPE. 10, CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK ADAPTOR, KOR-N-SEAL BOOTS OR APPROVED EQUAL. EDITED NOTES DCV AG 3/8/95 EDITED NOTES DCV AG DATE REVISION BY APPR'D SANITARY SHALLOW MANHOLE TYPE B ADOPTED . /_ � ♦ CITY OF RENTON STANDARD PLANS LST DATE: 12/96 DWG. NAME:BR37 SP PAGE:13072 CHECKED FOR COMPLIANCE TO CITY STANDARDS P I �STF�r NA [ �F, [EXPIRES Da/v8 /o STAMP N.:i ti =D GID -5.33� c�5 Date 2 Date Date RECOMMENDED FOR APPROVAL DALEY-MORROW-POBLETE, INC. 726 AUBURN WAY N. AUBURN, WASHINGTON 98002 HONE: (253) 333-2200; FAX: (253) 333-2206 ENGINEERING - SURVEYING LAND PLANNING incorporcot�-:: i . � 17