HomeMy WebLinkAboutWWP2703399.240
30
20
10
- 1-----
- ---- - - --- - - - - -
_ — — — — — — — — — — — — — — — — — — — —
* STA. 24+_1 G; fi3.0' LT. — — — \
1_ 1 %12" TEE (MJ X FL)
1 — 12" GV (FL X MJ)
±20 LF 12" 0 D.I.
1 - 12" CAP (MJ) W/ TEMP. 2„
BLOW -OFF ASSEMBLY
4-3/4" RODS
THRUST BLOCKS
_
40
w
M
p
30
APPROXIMATE
FINISHED GRADE
ii
EXISTING GRADE
AT CENTERLINE
o + CD
AT CENTERLINE
Ww
__--------------
z
20
TO LOT 31 TO FIRE HYDRANT
108 LF 12"0
DI INK
I I
00
140 LF
82 LF 8"0 PVC SEWER-�
MAIN AT 0.5% TO LOT
31 `
259 LF 8 0 PVC SEWER
MAIN AT 0 5(Y.
Ln
o
Ln
Lf)
N
00
o
co
N
o
0
0
�;
N
N
N
N
N
N
N
N
N
N
23+00
23+50 24+00
•lji% : as •� 31 «f « I r t rs a�
• «�•� ��« a r� •a.. �a 41321a a t aa� ra: «a•
AVA Mac
• r a a «a• eat « a 1N a• •A Pa ai • a• • •
Designed By:
Issue Date:
MPJ
07/07/08
Drawn By
MPJ/WLG
RECORD. DRAWINGS
Checked By:
Project No.
WED
30950005
24+50
g, L S. 711-3lo8
�C pF WASyIN
o���CIS
926
0 TER�� `�44
�SSIONAL Ee�� 606 Columbia St. N.W., Suite 106 T (360) 786-9500
EXPIRES 6/01/09 Olympia, WA 98501 F (360) 786-5267
25+00
www. PAcLAND.COM
25+50
26+00
GRAPHIC SCALE
20 0 10 20 40
( IN FEET )
I inch = 20 ft~
LEGEND
24+00
--I--- - CENTER LINE
- - RIGHT OF WAY LINE
PROPERTY LINE
- - - - - EASEMENT LINE
SS SEWER LINE
SEWER LINE STUB WITH PLUG
SEWER MANHOLE
W WATER LINE
►E WATER LINE STUB
FIRE HYDRANT 4
W-3.
►N GATE VALVE 3
W-3.
►i� THRUST BLOCKING
AIR / VACUUM
RELIEF VALVE
0B0 BLOWOFF ASSEMBLY
UTILITY NOTES:
1. ALL SANITARY SEWER PIPES TO BE 8"0 PVC SDR 35.
2. ALL WATER PIPES TO BE POLYWRAPPED 12"0 DUCTILE
IRON CLASS 52.
3. ALL SEWER, STORM AND WATER STUBS TO BE CAPPED
AND MARKED PER CITY OF RENTON STANDARDS.
*INSTALL 12" MJ CAP WITH 2" TEMPORARY BLOW -OFF
ASSEMBLY FOR ALL WATER STUBS TO INDIVIDUAL LOTS.
SHACKLE END CAPS TO VALVE AT MAIN LINE.
NOTE
THE MAXIMUM AVAILABLE FIRE FLOW FROM THE NEW 12-INCH WATER MAIN IS LIMITED TO Z800
GALLONS PER WNUTE (GPM). ANY DEVELOPMENT WITHIN THE BOEING LONGACRES PARK THAT
HAS A FLOW FLOW DEMAND OVER 2,800 GPM WILL BE REQUIRED TO INSTALL ADDITIONAL
OFF -SITE AND ON -SITE WATER MAIN IMPROVEMENTS, WHICH WILL INCLUDE, BUT NOT BE LIMITED
TO, A SECOND 12-INCH WATER LINE IN SW 27TH STREET FROM THE EXISTING 12-INCH WATER
LINE IN OAKESDALE AVENUE SW AND THE NEW 12-INCH LINE SHALL EXTEND TO THE WEST,
AND/OR AS REQUIRED TO PROVIDE THE REQUIRED FIRE FLOW DEMAND FOR THE PROPOSED
DEVELOPMENTS, IN CONFORMANCE WITH THE CITY OF RENTON'S DEVELOPMENT REGULATIONS.
BOEING LONGACRES PARK
NACRES AVE SW
RENTON, WA
80
S=339907
SANITARY SEWER AND WATER � SW-3.1
PLAN AND PROFILE
V i