Loading...
HomeMy WebLinkAboutWWP2703399.3SEC 257 T 23 N, R 4 E, W.M. ' * STA. 28+56 3.4' ILT. 1 — 12%12" TEE�MJ X FL) I STA. 28+54 30' LT*STA. 27+21, 12.1' LT. 1 — 12" GV FL XMJ I „ 1 — 12 x12 TEE MJ X FL � n( ' ) 12 WATER LINE STUB* f25 L.F. 12 D.I. 1 — 12" GV FL X MJ , � „ � LOT 28 *STA. 28+71, 5.3' LT. i ) , 1 — 12 CAP (MJ)I W/ 2 TEMP. I 1 — 12%12" TEE (MJ X FL) STA. 7+ I, 30 LT. STA. 28+67 30' LT. ., f25 L.F. 12"� D.I. BLOW —OFF ASSEMBLY I 1 — 12 GV (FL X MJ) „ " LINE STUB* ' �� 1 - 12 CAP (MJ) W/ 2 TEMP.: 12 WATER , 4 - 3 4 RODS ' 12" WATER LINE STUB* �. SOT 29 � / , I LOT 27 t25 L.F. 12 0 D.I. BLOW -OFF ASSEMBLY THRUST BLOCKS STA. 26+16, 27' LT. " , � '. 1 - 12 CAP (MJ) W/ 2" TEMP. BLOW -OFF ASSEMBLY GRAPHIC SCALE SANITARY SEWER STUB IE = 12.27 4 - 3/4 RODS STA. 28+,42, 28.45 LT. THRUST BLOCKS SANITARY, SEWER L 4 3/4-1" RODS a ,o 20 40 LOT 29 i , STUB IE i 11.11 I I THRUST BLOCKS CC W CLEANOUT - CATCH LINE (T'�P�.); � LOT 28 ( ! I STA. 28+91, 32' LT. x W/CLEANOUT I SANITARY SEWER ( I FEET ) 30 h „ 1 inch 20 ft. N N ti� MH 7 35.5 LF 8 PVC 0.5� L L - STUB IE = 10.48 # -----� _ — — — — — LOT 27 W/CLEANOUT 31 LF 8 0 P VC - 25.5 LF 8 0 PVC @-8.5% 5% 0 --__ I %� - i . o w / /, W / — w LF 12 LF .-� n - _ - - ,- 128 �12 D1 W 15 L - -I cry - -- - O 6 LF W W rap ,,, W F W W -- -- __ — — ►� — U 00 - -- - - - - - -_L 27+ 223 LF 8 0 PVC S - 1 3+00 _ _-- LEGEND _ _ _ I— cn -- - - - -- SS - sS S= Z S 1 J 1 _ - -fl0 0j 07 dd - -- - - - - _— ___. -- 1� t_ 29 �y 24+00 D Q S D I c, - —+ _ �____ 13 " CENTER LINE .. - . __ _ EX. 12 W — RIGHT OF WAY LINE _ ----_ _ _ `,I1 —�_ 2+00— LINE — — — PROPERTY =7;=�7 _— — — — --- �— —1 — — — — --EASEMENT LINE X— X-- X-- X-- X-- X-- X-- X— X X-= X-- X-- X-- — STA. 28+50 25 RT. FI E, HYDRANT ASSEMBLY INTERCEPT EXISTING SEWER LINE WITH NEW W�6 HYDRANT BARREL T - PIPE. AS FIRST ORDER OF WORK, �- SEWER LINE STUB WITH PLUG MH# 6 " I SIDEWALK (TYP.) PC 28+75.19 I / CONTRACTOR SHALL VERIFY HORIZONTAL - -EX. 12 W - - - - -� / I STA. f28+90, f11 RT. I '�-� � - - - - - - - - - - AND VERTICAL LOCATION OF SEWER SEWER MANHOLE PT - 26+83.41 � STA. 28+82.5, 7.5' LT. / I ZVE. NECT NEW WATER MAIN TQ EXISTING W TERM � �- -_ CONNECTION POINT AND NOTIFY ENGINEER W-3. I - PRIOR TO WORKI CONITRACTOIP TO VERIFIY r1 - 12" 45' BEND iIMMEDIATELY IF LOCATION IS NOT AS THRUST BLOCKS HORIZONTAL AND VERTICXL LOCATION IOF WIATER i �� SHOWN. W WATER LINE LINE CONNECTION. SEE RENTON STANDARD STA. 28+87, 4.5 LT. DETAIL B116. 1 1 I ►— WATER LINE STUB 1 — 12" 45' BEND I I I STA. 28+75.19 BACK = FIRE HYDRANT 4 THRUST BLOCKS STA. 3+36.37 AHEAD W-3. I N GATE VALVE 3 W-3. ►�d THRUST BLOCKING 0 AIR / VACUUM 40 40 RELIEF VALVE THE MAXIMUM AVAILABLE FIRE FLOW FROM THE NEW 12-INCH WATER MAIN IS LIMITED TO Z8W sB0 BLOWOFF ASSEMBLY GALLONS PER MMIUTE (GPM). ANY DEVELOPMENT WITHIN THE BOEING LONGACRES PARK THAT HAS A FLOW FLOW DEMAND OVER 2,800 GPM WILL BE REQUIRED TO INSTALL ADDITIONAL UTILITY NOTES: APPROXIMATE OFF SITE AND ON .SITE WATER MAIN IMPROVEMENTS, WHICH WILL INCLUDE, BUT NOT BE LIMITED 1. ALL SANITARY SEWER. PIPES TO BE 8 0 PVC SDR 35. .EXISTING GRADE TO, A SECOND 12-INCH WATER LINE IN SW 27TH STREET FROM THE EXISTING 12-INCH WATER AT CENTERLINE LINE IN OAKESDALE AVENUE SW AND THE NEW 12-INCH LINE SHALL EXTEND TO THE WEST, 2. ALL WATER PIPES TO BE POLYWRAPPED 12"0 DUCTILE AND/OR AS REQUIRED TO PROVIDE THE REQUIRED FIRE FLOW DEMAND FOR THE PROPOSED IRON CLASS 52. O (� ,�, o N 30 v DEVELOPMENTS IN CONFORMANCE WITH THE CITY OF RENTON, S DEVELOPMENT REGULATIONS. N �i _ - � - `�' �' ; =--N 30 3. ALL SEWER, STORM AND WATER STUBS TO BE CAPPED o J o AND MARKED PER CITY OF RENTON STANDARDS. o �in �-o N o� 'x - �L� �-� " Cn r, N * INSTALL 12" MJ CAP NTH 2 TEMPORARY BLOW —OFF pc� II II �O II Z o z z ASSEMBLY FOR ALL WATER STUBS TO INDIVIDUAL LOTS. w '.. w-z HACKLE END CAP _it,S S TO VALVE AT MAIN LINE. 20 10 26+00 26+50 27+00 27+50 11 fill I Is 1 ell M It IN01XXX' 8`1 v loll31 •1 Designed By: Issue Date: MPJ 07/07/08 Drawn By: RECORD DRAWINGS MPJ Checked By: Project No. WED 20(005.00 28+00 .� O Ls a, -71I$( 28+50 606 Columbia St. N.W., Suite 106 T (360) 786-9500 EXPIRES 6 /Ol /61 Olympia, WA 98501 F (360) 786-5267 www. PACLAND.COM 29+00 NG LONGACRES PARK NACHES AVE SW RENTON, WA W I S=339908 SANITARY SEWER AND WATER 2 PLAN AND PROFILE SW-3.