HomeMy WebLinkAboutWWP2703399.3SEC 257 T 23 N, R 4 E, W.M.
' * STA. 28+56 3.4' ILT.
1 — 12%12" TEE�MJ X FL) I STA. 28+54 30' LT*STA. 27+21, 12.1' LT. 1 — 12" GV FL XMJ I „
1 — 12 x12 TEE MJ X FL � n( ' ) 12 WATER LINE STUB*
f25 L.F. 12 D.I.
1 — 12" GV FL X MJ , � „ � LOT 28 *STA. 28+71, 5.3' LT.
i ) , 1 — 12 CAP (MJ)I W/ 2 TEMP. I 1 — 12%12" TEE (MJ X FL)
STA. 7+ I, 30 LT. STA. 28+67 30' LT. .,
f25 L.F. 12"� D.I. BLOW —OFF ASSEMBLY
I 1 — 12 GV (FL X MJ)
„ " LINE STUB* ' ��
1 - 12 CAP (MJ) W/ 2 TEMP.: 12 WATER , 4 - 3 4 RODS ' 12" WATER LINE STUB* �.
SOT 29 � / , I LOT 27 t25 L.F. 12 0 D.I.
BLOW -OFF ASSEMBLY THRUST BLOCKS
STA. 26+16, 27' LT. " , � '. 1 - 12 CAP (MJ) W/ 2" TEMP. BLOW -OFF ASSEMBLY GRAPHIC SCALE
SANITARY SEWER STUB IE = 12.27 4 - 3/4 RODS STA. 28+,42, 28.45 LT.
THRUST BLOCKS SANITARY, SEWER L 4 3/4-1" RODS a ,o 20 40
LOT 29 i , STUB IE i 11.11 I I THRUST BLOCKS
CC W CLEANOUT - CATCH LINE (T'�P�.); � LOT 28 ( ! I STA. 28+91, 32' LT. x
W/CLEANOUT I SANITARY SEWER ( I FEET )
30 h „ 1 inch 20 ft.
N N ti� MH 7 35.5 LF 8 PVC 0.5� L L - STUB IE = 10.48
# -----� _
— — — — — LOT 27 W/CLEANOUT
31 LF 8 0 P VC - 25.5 LF 8 0 PVC @-8.5% 5%
0
--__ I
%� - i . o
w / /,
W / —
w LF
12 LF .-� n - _
- - ,- 128 �12 D1 W 15 L -
-I cry - -- - O 6 LF
W W rap ,,, W F W W
-- -- __ — —
►� —
U 00 - -- - - - - - -_L 27+ 223 LF 8 0 PVC S - 1 3+00 _ _-- LEGEND
_ _ _
I— cn -- - - - -- SS - sS S= Z S 1 J 1 _
- -fl0 0j 07 dd - -- - - - - _— ___. -- 1� t_ 29 �y 24+00
D Q S D I c, - —+ _
�____ 13 " CENTER LINE
.. -
. __ _ EX. 12 W
— RIGHT OF WAY LINE
_ ----_ _ _ `,I1 —�_ 2+00— LINE
— — — PROPERTY
=7;=�7 _— — — — --- �— —1 — — — — --EASEMENT LINE
X— X-- X-- X-- X-- X-- X-- X— X X-= X-- X-- X-- —
STA. 28+50 25 RT.
FI E, HYDRANT ASSEMBLY INTERCEPT EXISTING SEWER LINE WITH NEW
W�6 HYDRANT BARREL T - PIPE. AS FIRST ORDER OF WORK, �- SEWER LINE STUB WITH PLUG
MH# 6 " I SIDEWALK (TYP.) PC 28+75.19 I / CONTRACTOR SHALL VERIFY HORIZONTAL
- -EX. 12 W - - - - -� / I STA. f28+90, f11 RT. I '�-� �
- - - - - - - - - - AND VERTICAL LOCATION OF SEWER SEWER MANHOLE
PT - 26+83.41 � STA. 28+82.5, 7.5' LT. / I ZVE.
NECT NEW WATER MAIN TQ EXISTING W TERM � �- -_ CONNECTION POINT AND NOTIFY ENGINEER W-3.
I - PRIOR TO WORKI CONITRACTOIP TO VERIFIY r1 - 12" 45' BEND iIMMEDIATELY IF LOCATION IS NOT AS
THRUST BLOCKS HORIZONTAL AND VERTICXL LOCATION IOF WIATER i �� SHOWN. W WATER LINE
LINE CONNECTION. SEE RENTON STANDARD
STA. 28+87, 4.5 LT. DETAIL B116. 1 1 I ►— WATER LINE STUB
1 — 12" 45' BEND I I I
STA. 28+75.19 BACK = FIRE HYDRANT 4
THRUST BLOCKS STA. 3+36.37 AHEAD W-3.
I
N GATE VALVE 3
W-3.
►�d THRUST BLOCKING
0 AIR / VACUUM
40 40 RELIEF VALVE
THE MAXIMUM AVAILABLE FIRE FLOW FROM THE NEW 12-INCH WATER MAIN IS LIMITED TO Z8W sB0 BLOWOFF ASSEMBLY
GALLONS PER MMIUTE (GPM). ANY DEVELOPMENT WITHIN THE BOEING LONGACRES PARK THAT
HAS A FLOW FLOW DEMAND OVER 2,800 GPM WILL BE REQUIRED TO INSTALL ADDITIONAL UTILITY NOTES:
APPROXIMATE OFF SITE AND ON .SITE WATER MAIN IMPROVEMENTS, WHICH WILL INCLUDE, BUT NOT BE LIMITED 1. ALL SANITARY SEWER. PIPES TO BE 8 0 PVC SDR 35.
.EXISTING GRADE
TO, A SECOND 12-INCH WATER LINE IN SW 27TH STREET FROM THE EXISTING 12-INCH WATER
AT CENTERLINE LINE IN OAKESDALE AVENUE SW AND THE NEW 12-INCH LINE SHALL EXTEND TO THE WEST, 2. ALL WATER PIPES TO BE POLYWRAPPED 12"0 DUCTILE
AND/OR AS REQUIRED TO PROVIDE THE REQUIRED FIRE FLOW DEMAND FOR THE PROPOSED IRON CLASS 52.
O (�
,�, o N
30 v DEVELOPMENTS IN CONFORMANCE WITH THE CITY OF RENTON, S DEVELOPMENT REGULATIONS.
N �i _
- � - `�' �' ; =--N 30 3. ALL SEWER, STORM AND WATER STUBS TO BE CAPPED
o J o AND MARKED PER CITY OF RENTON STANDARDS.
o
�in �-o N o� 'x - �L� �-� "
Cn r, N
* INSTALL 12" MJ CAP NTH 2 TEMPORARY BLOW —OFF
pc� II II �O II Z
o z z ASSEMBLY FOR ALL WATER STUBS TO INDIVIDUAL LOTS.
w '.. w-z HACKLE END CAP _it,S S TO VALVE AT MAIN LINE.
20
10
26+00 26+50 27+00 27+50
11
fill I Is
1 ell M It
IN01XXX' 8`1 v loll31 •1
Designed By:
Issue Date:
MPJ
07/07/08
Drawn By:
RECORD DRAWINGS
MPJ
Checked By:
Project No.
WED
20(005.00
28+00
.� O Ls a, -71I$(
28+50
606 Columbia St. N.W., Suite 106 T (360) 786-9500
EXPIRES 6
/Ol /61 Olympia, WA 98501 F (360) 786-5267
www. PACLAND.COM
29+00
NG LONGACRES PARK
NACHES AVE SW
RENTON, WA
W I
S=339908
SANITARY SEWER AND WATER
2
PLAN AND PROFILE SW-3.