Loading...
HomeMy WebLinkAboutWWP2703400.100 c0 o \ N O ,o ap 0 o Ln ;0 � Z,\ �� a o N Its � N C m 0z.0 m W'R N o 0 Ad 0 Q'+O I an N 0 W E W z -- ��oa zo Wa m� �m o� �g sx Z W0 >ir 0 x PORTION OF THE N.E. 1/49 OF SEC. 15, TWN 23 N., RGE 5 E., W.M. CITY OF RENTONWASHINGTON SANITARY SEWER NOTES AND SPECIFICATIONS d ( ( 1. ALL WORK MATERIALS SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATION OF THE CITY OF RENTON UTILITY DEPARTMENT AND THE EX. CB LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS. RIM=436.31 / d INV=432.56 ("ADS-N) ti a \ / ' 2. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH "STANDARD INV 432.65 (12"ADS-S) / I I \ i I h SPECIFICATIONS FOR MUNICIPAL PUBLIC WORKS CONSTRUCTION" PREPARED I EX. CB INV=432.65 (12"ADS-Wj / - - - - - - - - - - - - - - - - -__ - Cl BY WASHINGTON STATE CHAPTER AMERICAN PUBLIC WORKS ASSOCIATION, RIM=437.23 H __ --- -3 - _-_ - ` LATEST EDITION (APWA) AND CITY OF RENTON STANDARD SPECIFICATIONS. - - - - - - - - - - - - I I INV=430.58 (12"ADS-E) _ _ - _ 3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT ------------ INV=430.58 - ADS �- EX. SSMH e o - - - - - - sD RIM=436.61 I SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND - - � SD LSD-� 3 _ \ ti D ; INV=431.11 (8"PVC-N) L ti -- - - - - - - - - - - - - - _ CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. EX. CB INV=431.11 (8"PVC-W) N EX. 8" WATER Cl sb - Sn - SD - RIM-�3b:8-7 n w W - w - x4 eTr (g W w -w w -w -w - w _w w - w w w w EX. SSMH - W 4. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND EX. SSMH INVr433-22 12"ADS-N) y y RIM=43�e -� SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND H tz INV=430.51 (8"PVC-N) OTHERS ON THE CONSTRUCTION SITE. - w - w - w RIM=437.90 I w W __ L ND ON MENT, TYP. I a INV=430.51 (8"PVC-E) IN�%3-1rS j8"P�YC - w -� -- w w W - W s S - sMATdH5. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN INV=433.10 (8"PVC-E) O I s __ S s s s d CURB/GUTTER s - S _ S - S _ S - s �- S - S - S INV=430.46 (8"PVC-W) STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO ANY INV=430.46 (8"PVC-S) 0 s s -- s & SIDEWALK N s s S s s 3 s s- s CONSTRUCTION. -s _s MATCH EX. N.E. 3RD S T ti s s s -• <.- . <EX.-SOEWALK ' < �' '' r_� 6. PLANS APPROVED BY THE CITY OF RENTON, PUBLIC WORKS DEPARTMENT CURB/GUTTER -- s ' s °�^ `� SHALL TAKE PRECEDENCE OVER ALL OTHER PLANS. . < �• o- S � •� & SIDEWALK k��6� oe �--------------- _`• ° -- ,L 8. �/ "�_-__ _ 36� `� -. T BE ON THE JOB SITE EX. NO, WALK F WHENEVER CONSTRUCTION IS IN PROGRESS. i 9� 88*22 I N 3 � .40' 16" \ Q I 8 THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN 300 -- _- - 2 S 37'43"W 64 82' (; ® H / AS -BUILT DRAWING OF THE SANITARY SEWER SYSTEM, WHICH HAS BEEN 4' ,WOOD 95.1� 0 6" 36' Q ' ' � STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER OR LICENSED FEN£€ - - TREES TO BE RETAINED (� / EX. CB PROFESSIONAL SURVEYOR. ��j� ' STREET DEDICATION TREES TO BE RETAINED STRUCT ORANGE SAFETY I RIM=438.48 -CONSTRUCT ORANGE � AROUND TREES THROUGHOUT r� i e a INV=433.63 (12"ADS-N) 9. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN CE AROUND TREES TH GHOUT 10" ROAD/UTILITY AND/OR INV=433.63 (12"ADS-S) LAYERS WITH A LOOSE AVERAGE DEPTH OF 6 INCHES, MAXIMUM DEPTH OF 8 / » ftAD/UTlIUTY CONSTRUCTION OR HOUSE STRUCTION I I h DENSITY. THESE COMPACTEDHLY GEACH LAYERSLMUST EXO95 TENDPFORENT OF ONE PIPE DIMUM AMETER » 24 ti s ;� 8, 20" � 2 ° � I ! � I I ON EACH SIDE OF THE PIPE OR TO THE SIDE OF THE TRENCH. MATERIALS v TO COMPLETE THE FILL OVER PIPE SHALL BE THE SAME AS DESCRIBED. pr V » � � � y 3 � 0 5 10 20 10. OPEN CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXISTING 8" / : 14 I TRAVELED ROADWAY SHALL BE BACKFILLED WITH CRUSHED ROCK AND 6' WOOD MECHANICALLY COMPACTED. CUTS INTO THE EXISTING ASPHALT SHALL BE FENCE ` \ 8" g" rn ° 3 SCALE - 20 NEATLINE CUT WITH SAW IN A CONTINUOUS LINE. A TEMPORARY MIX PATCH 0' I I I MUST BE PLACED IMMEDIATELY AFTER BACKFILL AND COMPACTION. A n PERMANENT HOT MIX PATCH SHALL BE PLACED WITHIN 10 DAYS AND SHALL 16• 10" in �` " ° a I BE PER CITY OF RENTON CURRENT STANDARDS. 20" 1 � \ I 2" - MIN. FF= 1fi" g" o ° I , i 11. DATUM SHALL BE CITY OF RENTON, 1988 NAVD. 22 ACCESS & » QMIN. 437.0 \,_ o ° i EX. CB N U11UTIEs 48 437.0 12 $ 18 » " " � » o 10 00 � � I � a I RIM=437.33 12. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE EASEMENT » - 8 v I- `C _ N I 18 » " ° ( I INV 432.18 (12"ADS N) STABILIZED TO THE SATISFACTION OF THE DEPARTMENT FOR THE PREVENTION 8 I INV=432.18 (12"ADS-S) OF ON -SITE EROSION AFTER THE COMPLETION OF CONSTRUCTION. 8 p 3 I 36" 0 12" I I " I 1 ALL I AN APPURTENANCES HALL LAIDN A PROPERLY o 24" - - - - - - - - - - - - - - - - - - - PREPARED FOUNDATION IN ACCORDANCE WITH SECTION 7 OF THE CURRENT -- --- 4 6" I y s STATE OF WASHINGTON STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE 12" 16" 1 » I C O - - N88'21-'O9"W a I I CONSTRUCTTOM OR ON. THIS SHALL TOP OF THE INCLUDE FO NDAT NECESSARY MATERIAL,LEVELING OL AS E TRENCH 1 I 140.36' S._ - _ _ PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL, TO UNIFORM 8» N I EX. CB GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A RIM=437.15 UNIFORMLY DENSE, UNYIELDING BASE. PIPE BEDDING SHALL BE PEA GRAVEL 160.04' 1 C.O. U j • N INV=434.55 (12"ADS-W) % \ I 6" N 0 3 I 6 INCHES ABOVE AND BELOW THE PIPE. TREES TO BE8�A711�ED 6 " TREES TO TAINED m SD - SD -CONSTRUCT ORANGE SAFETY 6'' 106" 15' PRIVATE ?CONSTRUCT ORANGE SAFETY I I 14. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER FENCE AROUND TREES THROUGHOU 4 10' PRIVATE, ( SEWER/STORM FENCE;' AROUND TREES THROUGHOUT ti aw I GASKETED ASTM D 3034, SDR 35, OR DUCTILE IRON CLASS 50. ROAD/IJTIUIY AND/OR SEWER- I EASEMENT 8" ROAD/UTIUTY AND/OR, < ; / HOUSE CONSTRUCTION EASEMENT HOUSE CONSTRUCTION i - I3 I 15. IN UNIMPROVED AREAS, MANHOLE TO EXTEND MINIMUM 6 INCHES AND 18» 6 G \ \ MAXIMUM 12 INCHES ABOVE FINISHED GRADE. IN PAVED AREA, COVER MUST O 10» o ° roQCC MA)� SLOPE IN ALL DIRECTIONS TO MATCH PAVING. O O I » X 0 8 10" or- - I I ,,, I SSMH# 2, TYPE B-547 RIM=434:50•�'��+'� � MIN. �" 14" 12" 4, � ti W a 0 _ INV=*1 23 (6M) 21 I / 36" 436.0 PVC SIDE ° II Z I---------------- SHUPE k o MIN N. FF INV=429:06- (.8 ) 428 5 �r 6» SEWER 02% MIN., TYP. y W 3 I v �oF wAsypc � o =Nos 434.0 I 6" PVC SIDE Z 14" TREES TO BE RETAIL I I 36" -II o z 16=CONSTRUCT ORANGE SAFETY ( SEWER ® 2% MIN., TYP. ti Z s I ` ' ,` . c , - t,' w - - - - - - - - - - - - AD/UT�IUTTYN AND/OR I 116 " IE=429.1 f 16" 6" IE= I W I I >=K • cg'! �F,b,RCE � ,� ,p 11 �j Jcy N " HOUSE CONSTRUCTION - 2.5 OIL 428.5f ( 3 I M R 1I�f 12 N88'21'091, » r c C 1 Q I € �, AL LANO 10' PRIVATE ` 140.36' C�/ DRAWAG G I h - n SE +7;5�-8" PVC ® W 3 I THESE PLANS ARE "AS -BUILT" 1 " 0 I - I AND THE INFORMATION SHOWN �-� - -- so. 4 - - - - - - - - I ACCURATELY REFLECTS EXISTING = 3 _ 1 » 0 2" 18 I fib PUBLIC , 012- 8" 8" SEWER I 1 J FIELD CONDITIONS AS OF THIS cKUPE W~ o� W `� I I ----- 0 O 10 i► �/ EASEMENT SSMH# 1 \ I' H I I - - - - - - - - - - - - - DATE: -I/13/20! I of WA Z x 00 N o I _ 12" RIM=4 t (MATCH PAVING) w a 0 y o oa. o �, 8" " 10» --__ 0" NEW INV--428:26 �27 I I WILLIAM SHUPE HOLMBERG PLS 11332 N 14 EX V=42 .4 (VERIFY) I 1 '� r" 88 22 17 H E TREES TO BE RETAINED 7 6" O:f_ _ _ _ -CONSTRUCT ORANGE SAFETY � 3 � 2'- 12" SD O . I 14" � \ AROUND TREES THROUGHOUT Q - - ROAD/UTIUTY AND/OR 7- v 10 ` HOUSE CONSTRUCTION 0 ­445 -S3 O I 0 < �, e O qj � \ 3 3 12" N » N I _ 8O l - - 36 00 \U- - mof I V' I - - - - - - - - - - - - 37 MIN. FF= M.N. FF=» m a, `36 3 434.0 16" 0435. 0 L 1 J Lo B s-- 8. 8" 16 o �� " P I \ N 18" 8 I - Call ---- cr_lil> 1before you z s z _ D1g• 79.02' -800-424-5555 18" S8 27E 300.40' 900r of Q� UNDERGROUND SERVICE (USA)w o0 6" » s I AVOID TILITYCUTTING LINES. IT'S UNDERGROUND �o 1 8" 8 I R �7_ M EX. SSMH I » y \ RIM=434.03 a I I EX. CB P INV=425.83 RIM=433.38 I (8"PVC-N) ( m 3 I INV=425.73 (8"PVC-S) I INV=430.28 (12"ADS-W) JLn z » 2 s I I c g o I EX. CB I - - - - ,n Ed> 'I' - - - - - - - - RIM=433.57 I s INV=429.47 (12"ADS-N)tj i I INV=429.47 (12"ADS-E) I I (� N O SD SD � I INV=429.47 (12"ADS-S) I / 3D z :� LID 11332 ,,cv SIORAL EXPIRES 11/30/08 RECOMMENDED FOR APPROVAL BY BY CHECKED FOR COMPLIANCE TO CITY STANDARDS DATE .otf 0 W. a >s1�1 DATE DATE NOTE: EXISTING UTILITY LOCATIONS SHOWN HEREON ARE APPROXIMATE ONLY. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE EXACT VERTICAL AND HORIZONTAL LOCATION OF ALL EXISTING UNDER- GROUND UTILITIES PRIOR TO COMMENCING CONSTRUCTION. NO REPRESENTATION IS MADE THAT ALL EXISTING UTILITIES ARE SHOWN HEREON. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR UTILITIES NOT SHOWN OR UTILITIES NOT SHOWN IN THEIR PROPER LOCATION. CALL BEFORE YOU DIG: 1-800-424-5555. p �' - l 1 _'; 3 C b .5 -'34UD0 1