Loading...
HomeMy WebLinkAboutTED4003425.3SCALE: 1" = 20' 0 10 20 40 oa 20, CURB _ RADIUS a 5' SIDEWALK a° PUBLIC SIDEWALK28.69 ° EASEMENT TYP a e o s a FL 28.47 GRADE BREA 28.79 E o ° CEMENT CONCRETE a ° FL 28.54 - TRAFFIC CURB PER CITY OF RENTON q STD. DTL. F001 a 2' W/DE CONCR TE GUTTER TO CONVEY DRAINAGE MATCH EX. COAC. GUTTER N \FL 28.41 v, 8' SIDEWALK ISOUTH I Q OF GARAGE &NTRANCE 1 a 20' CURB RADIUS ° a C8 18 TOP 28.1 6" 1E 26.57 CB f 7352 TOP 28. 23 6"GONG IE26,53 (OUT-E) IN—W) i a 28.94 a ° 8.26 / 15, CURB RADIUS EX. FIRE HYDRA 7LL - I ' (GARDEN AVE. N) L OA DING ZONE DE TA IL 1 "=2O' NW 1/4 SEC 8, TWP 23 N, RGE 5, W.M. DR/ VEWA Y 5' 0.5' 2.8$ ` ( 2% MAX 0.5, " EXPANSION JOINT TYP SIDEWALK STD. PLAN F-3 SECTION E 5' M1N FOR SEE CONTR 0.62.1 0.5' SECTION F CEMENT CONCRETE DR/ VE WA Y DE TA IL NOT TO SCALE a Q Q. Q a a AND GUTTER (SEE NO TE 3) 5' T 6" CONCRETE (P. C. C. CLASS 4000, 3-DAY) (10" WITHIN R-O-W) 2" CRUSHED ROCK BASE (314" MINUS) OR COMPACTED SUBGRADE COMPACT TO 95X PER ASTM D1557 MODIFIED PROCTOR, MINIMUM 1' DEPTH. REFER TO THE GEOTECHN/CAL REPORT DATED JUNE 15, 2006 PREPARED BY GEOTECH CONSULTANTS, INC. FOR FURTHER DETAIL. CEMENT CONCRETE PA VEMEN T SECTION NOT TO SCALE 5' 4' CEMENT CONC. SIDEWALK 0.5, 2% _ (SECTION A T 5' SIDEWALK) SEC T/ON A -A NOT TO SCALE 61' 11' 4' CEMENT CONCRETE SIDEWALK -� 0, 5' 2%- VARIES 2% TO J. 5% _ 2% (SECTION AT 8' SIDEWALK) SEC T/ON B-B NOT TO SCALE 12' 11' 1.5, 8. 5' 2' PHASE 2 W 1' 2 2%, 2% o 4'' e ° _ /� a w.777 �� � ......�w����� ° CEMENT CONCRETE /�✓��/i�/ice � DR/ VEWA Y DEPRESSED CURB SECTION CEMENT CONCRETE TRAFFIC CURB AND GUTTER (SEE NOTE 3) I Y ENTRANCE DEPRESSED CURB AND ' GUTTER �EE N07E 3 a -- ISOMETRIC VIEW CEMENT CONCRETE DRI VEWA Y DETAIL NOT TO SCALE NOTES: 1. When the driveway width exceeds 15 feet, construct o full depth expansion joint (see Standard Plan F-3) with 3/8" joint filler along the driveway centerline. 2. Construct expansion joints parallel with the centerline as required at 15' maximum spacing when driveway widths exceed 30'. See Std. Pion F-3 for sidewalk details. 3. Curb and gutter shown, see the Contract. Plans for the curb design specified. See Std. Plan F-1 for curb details. 4. Avoid placing drainage structures, junction boxes or other obstructions in front of driveway entrances. 5. When driveway approaches are constructed in a commercial zone, the concrete driveway entrance shall be thickened from 6 inches to 10 inches. This includes concrete approach Types 1-4, sidewalks constructed behind the driveway apron, and the curb and gutter associated with each driveway approach. 9/3/2006 J Addition of Nate 5 Note an detoik I DCv I JF I (SECTION AT GARAGE DRI VEWA Y) SECTION C-C CEMENT CONCRETE DRIVEWAY ENTRANCE TYPES 1, 2, 3, & 4 Sheet 1 OF 6 Y 0 ADOPTED � CITY OF RENTON STANDARD PLANS L' ly LST DATE: 04/04 DWG. NAME: F004 SP PAGE: F00z NOT TO SCALE i 4' 4' REMOVE EX. CURB AND GU' �1. EX. FLOW LINE MATCH EX. CE! I_C�ONCRTTF PAL CEMENT CONCRETE PA VEMENT 2' CEMENT CONCRETE e 1W (L V� 1.1jgT a Uri 1' FACE OF CURB �Q4�6 t �''A 1B^ R 1' FL TCH RROOADV AY SLOPE TOP OF r. >b 1rr R. ROADV AYof Sf 'a 'ELaxAf 6 i ExPRE5 MAY 16.2003 CEMENT CONCRETE CEMENT CONCRETE CURBS TRAFFIC CURB AND GUTTER STANDARD PLAN Ill SHUT I OF 1 8NEFr A66PtEo CITY OF RENTON + ArAft + STANDARD PLANS LAST DATE: 12/17/2002 SP PAGE FO01 CITY OF RENTON i Approved by: J' Date: Approved by: Date: Approved by: Date: Approved by: Date: I TRIAD ASSOCIATES 12112 115th Ave. NE Kirkland, WA 98034-6929 425.821.8448 425.821.3481 fax 800.488.0756 toll free www.triadassoc.com I Z 3 J �.1 LU Q Z N o J O Q J UJ 4 � cc LL W It o V N N V W U A � o a tmu m 0 ,Q � V ^zz2 O N pJ pJ Ct k pJ RI Ct O z z N DAWD ROBERTSM, PLS PROJECT MANAGER ROBERT WALLS PLS PROJECT SURVEYOR SHERI MURA TA, PE PROJECT ENGINEER DENISE LIFTIN, ASLA PROJECT LANDSCAPE ARCHITECT FIRST SUBMITTAL DATE: 4118107 SCALE: HORIZ.: 1 "-20' VERT.: N/A EXPIRES: 11/12/CCI STAMP NOT VALID UNLESS SIGNED AND DATED JOB NO. 06-225 SHEET N0. 70F 7 Y t� t7 m .ti Y ' �n tri o z b �C N V1 C0 R-�4ZSOb Q 2008 TRIAD ASSOCIATES