Loading...
HomeMy WebLinkAboutWWP2703425.1NW 1/4 SEC 8, TWP 23 N, RGE 5, W.M. WE,IqT _. A TER PL A N "=10r Z D CAUTI-0 VALVE BOX SHOULD NOT REST ON PIPE. LATER COMPACTION IN AREA OF VALVE BOX COULD CAUSE THE BREAKAGE OF THE SERVICE. z 1-1/2" AND 2" WATER SERVICE DETAIL MATERIAL LIST FOR a" SERVICE WITH MEJEJ3 LOCATED IN RIGHT-OF-WAY BEHIND SIDEWALK L 2' tapped tee on new water meter. 2. 4" long X 2" brass nipple with threaded ends (MIPT). 3. 2" resilient seat valve with threaded ends, square operating nut and wive nut extension if required (dwg BR41/page 8090). 4. Two piece cast Iron valve box. Standard 8' top section with regular base section, length to fit, 'lug" type cover. 5. 2' brass bushing (MIPT x FIPT) 2 each 2" brass or bronze nipples 6" length, threaded ends 2 each 2"-90' brass or bronze elbows (FIPT x FIPT) 6. 2' (MIPT) x compression fitting, Ford C84-66 or equal. 7. 2' soft copper type K or brass nipples, length to fit. 8. 2" threaded brass 90' ell. 9. 2" Customsetter with by-pass Ford VSH 85-128-11-77 (17-3/16") or McDonald brass 3OB715WOFF775. with flanged angle ball valve and padlock wings on inlet, and angle check valve outlet, ball valve on bypass with padlock wings. Customsetter shall have vertical inlet and outlet. 10. Rigid meter spreader to be supplied and Installed in meter setter by contractor. 11. Water meter shall be supplied and installed by City of Renton upon payment of all related water meter fee and satisfactory pressure and purity tests. 12, 17"x30" equal to Mid -States Plastics, Inc. BCF Series MSBCF 1730-18 with 2' thick Ductile iron damond plate cover 18'x3l" equal to Mid -States Plastics, Inc. MSCBC-1730-R with 1-5/8" drilled hole for touchread pit lid, and meter read lid. 13. 2' coupling (compression x F)PT) with 2' plug (MIPT), Ford C-14-66 or equal. The property owner is responsible for any necessary adaptation or extension of water service. PRIVATE PLUMBING SHALL CONNECT HERE I' BRASS PLUG THREADED) S NOT ALLOYED CATION METERS DRILL 1-5/8' DIA. HOLE FOR A - A TOUCHREAD DEVICE TYPICAL. RIB 2-1/2' MIN. FROM NEAREST AND FRONT EDGE OF PIT LID MATERIAL. LIST FOR 1-1f2" SERVICE WITH METER LOCATED IN RIGHT -Of -WAY BEHIND SIDEWALK 1. 2' tapped tee on new water main 2. 4' long X 2" brass nipple with threaded ends (MIPT). 3. 2" resilient seat valve with threaded ends, square operating nut and valve nut extension if required (dwg BR46/poge 8090). 4. Two piece cast iron valve box_ Standard 8" top section with regular base section, length to fit, "lug' type cover. 5. 2' X 1-1/2" hex brass bushing (MIPT x FIPT) 2 each 1-1/2' brass or bronze nipples 6' length, threaded ends 2 each 1-1/2"- 90' brass or bronze elbows (FIPT x FIPT) 6. 1-1/2" (MIPT) x compression fitting, Ford C84-66 or equal. 7. 1-1/2' soft copper type K or brass nipples, length to fit. 8. 1-1/2" pack -pint 90' ell, for Ford L44-77 or equal. 9. .1-1/2" Customsetter with by-pass Ford VBH 66-12B x 13-3/16" or McDonald brass, with flanged angle ball volve and padlock wings on inlet, and angle check valve outlet, ball valve on bypass with padlock wings. Customsetter shall have vertical inlet and outlet, 10. Rigid meter spreader to be supplied and installed in meter setter by contractor. 11. Water meter shalt be supplied and installed by City of Renton upon payment of ali related water meter fee and satisfactory pressure and purity tests. 12. 17"x30" equal to Mid -States Plastics, Inc. BCF Series MSBCF 1730-18 with 2" thick Ductile Iron damond plate cover 18"x31" equal to Mid -States Plastics, Inc. MSCBC-1730-R with 1-5/8" drilled hole for touchread pit lid and meter read lid. 13. 1-1/2" coupling (compression x FIPT) with 1-1/2" plug (MIPT), Ford C-14-66 or equal. The 1-1/2" & 2„ WATER SERVICE DETAIL property owner is responsible for any necessary adaptation or extension of water service. LOCATED IN RIGHT-OF-WAY DOTE: BEHIND SIDEWALK SEE BR41-TR ON METER BOX IN DRIVEWAYS ti O ADOPTED CrrY OF RENTON STANDARD PLANS nr 1� 1ST DATE: O4/04 I -Wort-ac�nclnn� --"� -_� ❑v nor;o n i1VAG NANE: 8107.2 SP PAGE: 31,07.2 IRRI GA TION SERVICE 4" POST INDICATOR VALVE (MJXMJ) PAINTED BLUE 4' 90- BEND (MI) 2-3/4" SHACKLE RODS PER CITY OF RENTON SPECIFICATIONS 13 LF 4' D.I. 4' 90' BEND (MJ) z 6 TE VALVE (FLE (MJXFL) �MIJ) a 1?• 4" FLxMJ ADAPTOR ¢ 4" FLxMJ ADAPTOR LADDER WITH + SUPPORT BARS • 2'-4" I 4' or 6" O.IL PER OSHA _+ TO BUILDING �--- EPDXY NON-SHR!t4K OW GROUT ' 2'-4' - f [ 4' TEE (MJxFL) - / -- 1}I WELDED STEEL COLLAR TOUCH READ PIT LID SENSOR MOUNTED ON STEEL PLATE COVER THROUGH 1-5/8" DIA, DRILLED HOLE IN COVER, PRECAST CONCRETE VAULT WITH 2 3'x3' HINGED STEEL PLATE COVER. OUTSIDE DFMEN90NS 4'-8'x7'-O'. (EQUAL TO PIPE INC., OR UTILITY VAULT WlYH 57-7L-B, 2 3'x3' DIAMOND PLATE DOORS) 6',4' OR 3' GATE VALVE (FLxFL) NON -RISING STEM WITH HAND WHEEL ECLAL TO MUE'LLER CO.A-2380-6. 6" OR 4" (FLxPE) CEMENT LINED DUCTILE IRON PIPE CLASS 52 3'-6' LONG WITH COLLAR 20' FROM P.E. EQUAL TO THOSE SUPPLIED BY PACIFIC (- WATER WORKS CO. INC.3 y 4' FLOW- , 2' cm PravATE PERRC PptNG DEADMAN BLOCK ( TEEJ REQUIRED WITH (FL) SHACKLING TO TEE TOUCHREAD PITLID SENSOR MOUNTED ON STEE1_ PLATE COVER TWO PIECE CAST IRON VALVE BOX EQUAL TO OLYMPIC FOUNDRY CO. / STANDARD 8' TOP SECTION, WITH REGULAR BASE SECTION LENGTH TO FIT. 6'.4" OR 3' COMPOUND WATER METER (FL) J EQUAL TO SENSUS SRH COMPOUND METER WITH / TOUCHREAD PITiJD REGISTER dk SENSOR WITH 4 WHEEL HIGH RESOLUTION (1DO CUBIC FEET) L ADJUSTABLE STEEL REGISTER. FOR 3' METER, REDUCE AT METER PIPE SUPPORT WITH 4"X3" FLxFL CONCENTRIC REDUCER, STANCHION BOLTED TO FLOOR GENERAL NOTES ALL METERS AND BACKFLOW PREVENTION DEVICE COMBINATIONS ARE NOT SHOWN OR INCLUDED IN THE STANDARD DETAIL DRAWINGS. IF YOUR PARTICULAR COMBINATION IS NOT SHOWN, AN APPROVED DRAWING WILL BE REQUIRED BY THE UTILITY ENGINEERING DEPT. FOR ITS INSTALLATION. THE PRINCIPAL REQUIREMENTS REGARDING VAULT SIZING ARE THE LENGTH OF FITTINGS OR THEIR CLEARANCE FROM THE VAULT WALLS, (WHICH CLEARANCE SHALL BE A MINIMUM OF 12' FROM THE ENDS AND THE SIDE CLEARANCE SHOULD BE AS TYPICALLY SHOWN ON THE VARIOUS STANDARD DETAILS). NOTE- DEADMAN BLOCK SHALL BE DESIGNED AND INSTALLED SO IT BEARS AGAINST SUFFICIENT UNDISTURBED EARTH SO AS TO SUPPORT THE DESIGNED THRUST. VALVE NUT EXTENSION IF REQUIRED (DWG BR46/PAG'E 8090) 6', 4' OR 3" GATE VALVE (FLFMJ) EQUAL TO MUELLER CO. A-2380-20, TO BUILDING -T C�,T-- PRIVATE PIPING 6" OR 4' PEXPE CEMENT LINED DUCTILE IRON PIPE CLASS 52. LENGTH TO FIT. 6" OR 4' FLEXIBLE FLANGED COUPLING ADAPTOR, ROMAC OR APPROVED EQUAL. 3". 4" & 6" COMPOUND METER SERVICE Y ADOPTED CITY OF RENTON STANDARD PLANS LST DATE: 04/04 DWG NAME: 810E SP PAGE:8108 DOMES TIC WA TER SERVICE EAST WATER PL A N ill-10' SCALE: 1" = 10' 0 5 10 20 %44*3+21502 CITY OF RENTON Approved by: 1ir,���G-=' - Date: l Approved by: Approved by: Date: Date: TRIAD ASSOCIATES 12112 115th Ave. NE Kirkland, WA 98034-6929 425.821.8448 425.821.3481 fax 800.488.0756 toll free wwwAriadassoc.Gom co Z Q a Z Q V 2 O UEr Q � Of Q � U) to V) to wwh E-� A Q W m Z Y CIO 2� U W O Z ry =+' Q� O a l\ O O z DAWD ROBERTSON, PLS PROJECT MANAGER ROBERT WALLIS, PLS PROJECT SURVEYOR SHERI MURATA, PE PROJECT ENGINEER DENISE LIF71N, ASLA PROJECT LANDSCAPE ARCHITECT FIRST SUBMITTAL DATE: 4118107 SCALE: Holm.: 1 "=10' VBRT.: N/A EXPIRES: 11/12/Q9 STAMP NOT VALID UNLESS SIGNED AND DATED JOB NO. 06-225 O Approved by: cu W- 2,42��,DI Date: ©2008 TRIAD ASSOCIATES SHEET N0. 60F