Loading...
HomeMy WebLinkAboutTED4003426.44M O 0 Cn U i Cn m i co 0 U v C_ Cn 0 c� z W z c� Cn w 0 i Q Iz 0 n cn Q Iz 0 0 f) r) N I 0 06 N Q Q) Cn z I 00 12" LED RED FLASHING WARNING LIGHTS r--F"O PANInPnl 1 as NIIPPI P- I nrATInNI** 12" LED RED FLASHING WARNING LIGHTS SEE ST05 FOR NEMA 3R TERMINAL CABINET DETAILS ----HANDHOLE SACRIFICIAL BEAM ELEVATION YELLOW TYPE B JUNCTION BOX 2" PVC CONDUIT * CONTRACTOR TO VERIFY NIPPLE LOCATION, PRIOR TO SIGN STRUCTURE FABRICATION. NO FIELD WELDING & DRILLING SHALL BE PERMITTED. ** HANDHOLD IS ONLY REQUIRED IF NIPPLE LOCATION IS GREATER THAN 1'-6" FROM ANOTHER HANDHOLE LOCATION. FOR DETAIL OF HAND HOLE, SEE WSDOT STD. SIGN BRIDGE 10.1—A2-2. NOTES: 1. INSTALL 2—#12 AWG AND 1—#12 AWG GROUND FROM WARNING LIGHT CONDUCTORS IN JUNCTION BOX TO FLASHING CONTACTOR IN NEMA-3R TERMINAL CABINET ON TOP OF BEAM. 2. INSTALL 2—#12 AWG AND 1—#12 AWG GROUND FROM FLASHING CONTACTOR TO 12" LED RED FLASHING WARNING LIGHTS. RECORD DRAWINGS SEPTEMBER 2010 BASED ON CONTRACTOR'S RECORDS DMJM HARRIS AECOM 10900 NE 8TH STREET, SUITE 750 BELLEVUE, WASHINGTON 88004 PHONE: (425) 454-5600 FAX: (425) 454-0220 R. G' r7 0 0029998 R 342644 APPROVED FOR CONSTRUCTION CITY OF RENTON DATE l UNIT ;EEN WHITE GREEN LIVE N G FLASHINGTO ` =F.01. 120V BEACONS SOURCE WIRING DIAGRAM LF:—. FL—ASHING BEACON CONTROL ASSEMBLY B N 2— 3/4„ 10� MOUNTING PLATE FOR SIDE MOUNTING �— STRUCTURAL COLUMN OR PLATE SECTION A —A REVISION 1 /2" 0 STANDARD BOLT (-Al \iiN17p-n 1 /2" 0 LO WASHER CABLE GU 1 /2" 0 NUT SURVEYED: DESIGNED: D.BELLUOMINI DRAWN: Y.DARMAWAN `'IECKED: J. KIM APPROVED: R.MEYER SECTION B—B KEY 0LOCK NIPPLE O2 NIPPLE O3 NOT USED GGASKET AND WASHER O 12" LED WARNING LIGHT WITH BACK PLATE O6 MOUNTING PLATE (SEE DETAIL BELOW) DRILL HOLES AND ATTACH MOUNTING SHELF TO PROT TEE WITH (2) — 1 /2" BOL_ LOCK WASHERS AND NUTS POLE PLATE FOR WARNING LIGHTS 7/16" THICK PLATE -LAT WASHER 1-1/2" NPS PIPE THREAD FRUCTURAL DLUMN OR _ATE SCALE: N.T.S. VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY r•- i i �............... .—.—.—._ 5 12 LED WARNING LIGHT MOUNTING DETAIL MOUNTING SHELF FOR WARNING LIGHTS ATTACHED TO PROTECTIVE TEE ON BRIDGE (PLATE, NUTS AND BOLTS ARE GALVANIZED) • CITY OF �R RENTON Public Works Dept. FED AID NO.: ARRA-0167(044) 12" LED WARNING LIGHT WITH STANDARD 30R AND 5" BACKr:_"']'E RAINIER AVE S (SR 167) UAI t: IMPROVEMENTS PROJECT FIELD, P HAS E 1 PAGE: SHATTUCK AVE S STORMWATER BYPASS DRAW SACRIFICIAL BEAM, TS03 LED FLASHING BEACON CONTROL ASSEMBLY SHEET.43 OF:48 Ot� *, k-1 I D273426 Ua C/� t7i r rD 1 �m W �y N �a h