HomeMy WebLinkAboutTRO4103430.153IRRIGATION SCHFnIII F n ter` N 0 N �r N 0 0 Ln Ln Q0 0 U i AN,, 0 Ln Ln CO O z W c) 0 w 0 SYMBOL MANUFACTURER MODEL NO. DESCRIPTION RAINBIRD BUBBLER SERIES-1402 FULL —CIRCLE FLOOD BUBBLER — INSTALL PER DETAIL SHEET 293. EST SST RAINBIRD 1800-15 STRIP SERIES SHRUB HEAD — 6" PLASTIC POP—UP. 5'x15', 5'x30' AT 30 PSI. SIDE & END STRIP NOZZLE, INSTALL ON FLEXIBLE RISER ® 0 RAINBIRD 1800-15 STRIP SERIES LAWN HEAD — 6" PLASTIC POP—UP. 5'x15', 5'x3O' AT 30 PSI. SIDE & END STRIP NOZZLE, INSTALL ON FLEXIBLE RISER 8Q 8H RAINBIRD 8 SERIES MPR SHRUB HEAD — 6" PLASTIC POP—UP. ADJ TO 8' RADIUS AT 30 PSI. INSTALL ON FLEXIBLE RISER k' m m RAINBIRD 12 SERIES MPR LAWN HEAD — 6" PLASTIC POP—UP. ADJ TO 12' RADIUS AT 30 PSI. INSTALL ON FLEXIBLE RISER 12Q 12H 12F ® � 12Q 12H RAINBIRD 12 SERIES MPR SHRUB HEAD — 6" PLASTIC POP—UP. ADJ TO 12' RADIUS AT 30 PSI. INSTALL ON FLEXIBLE RISER C RAINBIRD 15 SERIES MPR SHRUB HEAD — 6" PLASTIC POP—UP. 15' RADIUS AT 30 PSI. INSTALL ON FLEXIBLE RISER 5Q 15 , ; :F ra 6L 9 ! 15 SERIES MPR LAWN HEAD — 6" PLASTIC POP—UP. 15' RADIUS AT 30 PSI. INSTALL ON FLEXIBLE RISER I5Q 15H 15FJ�INBIRD s SENTINEL SATILLITE (2) 24—STATION OUTDOOR CONTROLLERS (A & B), STAINLESS STEEL PEDESTAL MOUNTED WITH CONCRETE IR (I TORO A—SSAK24PS16NS1 FOUNDATION. SEE SIGNAL PLANS FOR ELECTRICAL SERVICE. PROVIDE 3 SPARE WIRES (RED) FROM CONTROLLER B—SSAK24PS16NS1 THROUGH EACH CONTROL VALVE BOX, TO FURTHEST VALVE BOX FROM CONTROLLER. PROVIDE TELEPHONE LINE TO I CONTROLLERS FOR TELEPHONE MODEM. ® WEATHERMATIC 2100 AUTOMATIC CONTROL VALVE — SIZE AS NOTED ON PLAN. POC—A POINT OF CONNECTION EQUIPMENT, APPROX. STA 26+65, 50' RT. SEE DETAILS THIS SHEET AND SHEET 293. D4 FEBCO 850 1 1/2" DOUBLE CHECK VALVE. WEATHERMATIC 2100 1 1/2" MASTER SHUTOFF VALVE AND TORO TFS FLOW SENSOR QO RAINBIRD 44—LRC 1" BRASS QUICK COUPLER VALVE WITH LOCKING VINYL COVER. INSTALL PER DETAIL. INSTALL ONE AT DOUBLE CHECK VALVE ASSEMBLY. E 1 1/2" IRRIGATION METER. SEE WATER PLANS FOR MORE INFORMATION. POC—B POINT OF CONNECTION EQUIPMENT, APPROX. STA 35+82, 44' LT. SEE DETAILS THIS SHEET AND SHEET 293. D4 FEBCO 850 1 1/2" DOUBLE CHECK VALVE. WEATHERMATIC 2100 1 1/2" MASTER SHUTOFF VALVE AND TORO TFS FLOW SENSOR i RAINBIRD 44—LRC 1" BRASS QUICK COUPLER VALVE WITH LOCKING VINYL COVER. INSTALL PER DETAIL. INSTALL ONE AT DOUBLE CHECK I VALVE ASSEMBLY. 1 1/2" IRRIGATION METER. SEE WATER PLANS FOR MORE INFORMATION. — — PVC SCH 40, IRRIGATION MAIN LINE — 24" MIN COVER PVC SCH 40, LATERAL SUPPLY LINE— 18" MIN. COVER — SIZE AS NOTED. — — SLEEVING, PVC SCHEDULE 40, SIZE TWICE INSERT PIPE DIA. 1S 1F A INDICATES VALVE & CONTROLLER # "A" OR "B" INDICATES CONTROLLER A OR B 10.5 INDICATES APPROX. GPM "is" INDICATES VALVES FOR STREETSCAPE PLANTER ZONES. INDICATES VALVE SIZE "1F" INDICATES VALVES FOR FILTERRA/TREE GRATE ZONES. DOUBLE CHECK VALVE PRESSURE REDUCING VALVE POC VALVE BOX IRRIGATION GENERAL NOT' - QUICK COUPLER (2) STAINLESS STEEL CLAMPS TO STAKE P.V.C. NIPPLE 3' #4 REBAR STAKE 360' PVC TRIPLE SWING JOINT P.V.C. PRESSURE MAIN PVC TEE OR ELBOW WITH SIDE ELEVATION THREADED OUTLET QUICK COUPLER OR SPRINKLER BODY 360' PVC TRIPLE SWING JOINT PVC THREADED TEE AT MAINLINE SECTION THROUGH MAIN LINE QUICK C011PLINC.. VAI VF/ TRIPI F SWIN[...ICIINT NOTE: ALL THE FITTINGS AND PIPE TO BE SAME DIA. AS IPS FEMALE CONNECTION OF QUICK COUPLER/ SPRINKLER HEAD INSTALL IN DCVA BOX QUICK COUPLING VALVE, SEE DETAIL THIS SHEET ALL FITTINGS PVC COORDINATE INSTALLATION OF IRRIGATION SYSTEM WITH INSTALLATION OF OTHER UTILITIES, INCLUDING JOINT TRENCH AND FILTERRA UNITS. LOCATE AND PROTECT ALL UNDERGROUND UTILITIES DURING INSTALLATION OF IRRIGATION SYSTEM. IRRIGATION SYSTEM SHALL BE INSTALLED, TESTED, MAINTAINED AND GUARANTEED AS PER SPECIFICATIONS. IRRIGATION SYSTEM IS DESIGNED TO OPERATE FROM 30 PSI. CONTRACTOR SHALL FIELD CHECK EXISTING WATER PRESSURE, ADJUSTING PRV AS NECESSARY TO PROVIDE OPTIMUM PERFORMANCE. LOCATIONS OF IRRIGATION MAIN LINE, LATERALS, SLEEVING AND VALVES INDICATED ON DRAWINGS ARE. SCHEMATIC ONLY. ADJUST LOCATIONS AS NECESSARY. DO NOT OVERSPRAY ONTO PAVED SURFACES. IRRIGATION MAIN LINE LOCATION IS DIAGRAMMATIC LINE SHALL BE PLACED IN PLANTING AREAS V? ?E EVER POSS191 F MAIN LINE SHALL BE BURIED TO A DEPTH OF 24" BELOW FINISH C' A -DE, LATERAL LINE FOR SPRAY ZONES SHALL BE BURIED TO A 01EPTH OF 18" BELOW FINISH GRADE. LATERAL LINE FOR BUBBLER ZONES SHALL BE BURIED TO A DEPTH OF 12" BELOW FINISH GRADE. SLEEVE UNDER ALL PAVED SURFACES, CONCRETE SIDEWALK AND BETWEEN FILTERRA UNITS AND SIDEWALK. SEE IRRIGATION PLANS FOR LOCATION OF PVC SLEEVING, SLEEVING SHALL BE 2 TIMES THE DIAMETER OF THE INSERT PIPE AND WIRES. CONTROLLER WIRES SHALL BE TAPED TOGETHER IN A BUNDLE AT 10' INTERVALS. SNAKE WIRE IN BOTTOM OF PIPE TRENCH WHERE POSSIBLE. WHERE PIPE TRENCH IS UNAVAILABLE WIRES SHALL BE PLACED IN SLEEVING. WIRES TO CONTROLLER SHALL BE PLACED IN 1" / 1.5" SLEEVE, USE 3M DBY SPLICE KITS. ALL EQUIPMENT SHALL BE AS SPECIFIED OR APPROVED EQUAL BY CITY OF RENTON. SYSTEM IS SPECIFICALLY DESIGNED FOR IRRIGATION EQUIPMENT SHOWN ON PLANS AND SUBSTITUTION WILL REQUIRE REDESIGN AND RECALCULATION OF IRRIGATION ZONES. NO GALVANIZED FITTINGS. ONLY BRASS OR SCH 40 PVC SHALL BE USED. IRRIGATION TRENCHING NEAR ANY TREES TO REMAIN SHALL BE DONE WITH THE MINIMUM AMOUNT OF DISTURBANCE POSSIBLE. TRIM AND CUT CLEAN ANY EXPOSED OR DAMAGED ROOTS. STACKED METER BOXES PER CITY OF RENTON STANDARDS. SIZE TO FIT EQUIPMENT. --i �-- COMPACT BACKFILL APPROVED DOUBLE CHECK VALVE, INSTALL I —I i PER CITY OF RENTON STANDARDS. PRESSURE REDUCING VALVE SHUT OFF VALVE AND FLOW SHUT OFF VALVE �- IN SEPARATE VALVE BOX PVC IRRIGATION MAIN , RIGATION METER ° ° o a ° a° o°° °o° °� ° o ° ° s o04 0..O0 O°o:00 °° . 0 °° °°�O 'o.o: o.0 0 .o .°° ° �0 . °0 0 0 O ° o 0 0 • ° ° ° Lz TO PRESSURE MAIN ° ° ° ° 0 ° Q° ° 0 °0 8" MIN DEPTH PEA ° ° .0 ° ° ° GRAVEL, WITH FILTER NOTE: — — � � �III � FABRIC CONNECTION TO PRESSURE MAIN SHALL NOT BE MADE UNTIL IRRIGATION MAIN LINE IS PRESSURE Iy 1" QUICK COUPLER VALVE TESTED. INSTALL ASSEMBLY IN ACCORDANCE WITH CITY OF RENTON STANDARD PLAN - 340.8. SEE POINT OF CONNECTION ASSEMBLY, THIS SHEET. TYPIrAL POINT OF r' NNE+ TION ASSEMBLY N 1 ..) - - NUMBER REVISION nFTAII nni ]R1 F ('.HF['.K VAI VF ASSFMRI V PRESSURE MAIN CONNECT TO MASTER SHUT OFF VALVE (INSTALLED IN SEPARATE BOX) T=3430232 V� t�O�U o Z Q Cn-�W ' N 5 �3�v�i o Q J 11-14-11 0 °vl_ ~ a Q~ of U SURVEYED: KPG DRAWN BY: EM DESIGN BY: EM CHECK BY: EG PROJ MGR: JF FILE:0655DIRR01.dwg Kp� R 753 9th Avenue N 2502 Jefferson Avenue "' I D Seattle, WA 98109 Tacoma, WA 98402 (206)286-1640 (253)627-0720 DOCUMENTS www.kpg.com �'- CITY OF R +NTON �, — Public Works Department APP VED FOR CONSTRUCTION BY: DATE;/ /-1i RAINIER AVENUE S (SR 167) S GRADY WAY TO S 2ND ST IRRIGATION SCHEDULE AND DETAILS DRAWING NO. 292 PROJECT NO. TED403430 FED AID NO.-CM0167(048) DATE: NOV 2011 SHEET NO. 292 OF 304 APP. DATE 11F