WALL 4
#5@12
®#5@12
ROADWAY
SLAB -- 7'F/#5@12 --`
JOINT f
3 L!R
ROADWAY
SLAB �--,
2" CLR TYP
#5@12 EW
#5@12 EW
21-021 5-41f
OR4 —4"�
SECTION A
SCALE: 1 /2" = 1'-0" —
u ! 1'
ffilIN,
00
w
ry
a
#4 @18
21-61) `/)
NOTE:
FOR WALL AND FTG SIZE
AND REINF SEE A/ —
SECTION C
SCALE: 1 /2" = 1'-0" —
VARIES
Lij
#4@18 EW AT
MID DEPTH
SECTION
SCALE: 1 /2" = 1'-0"
J
•
~ NUMBER REVISION DESCRIPTION
•
5"
MIN
#4@12 EW
PIPE SEE CIVIL
DRAWINGS
1'_(1" %inoicc
5'-4"
AT BRIDGE PIER
SECTION g
SCALE: 1 /2" = 1'-0"
#4@18 EW AT
MID DEPTH —
i
SECTION p
SCALE: 1 /2" = 1'-0"
OPTIO
z
JOINT
0
I
PIP AT FOOTING
DETAIL
SCALE: 1" = 1'-0" TYP
s
Iv
SURVEYED:
KPG
DRAWN BY:
E.THOE
DESIGN BY:
P.HEATHCO'
CHECK BY:
&BRIGHT
PROJ MGR:
JF
FILE: 36.dwg
ivi u v
TYP
EXIST BRIDGE
PIER
�a DENSITY
POLYSTYRENE
ADD # 4 3'-0
EA FLUTE
BACKFILL
10" MIN
WALL 5 PERMANENT
SHEET PILE WALL
PZ22 BY SKYLINE
STEEL OR ACCEPTABLE
EQUIVALENT
MIN TIP EL 12.0
GENERAL STRUCTURAL NOTES
DESIGN CRITERIA
APPLICABLE BUILDING NOTES AND CODES
INTERNATIONAL BUILDING CODE, IBC 2009 EDITION, EXCEPT WHERE OTHER CODES ARE MORE
RESTRICTIVE,
FOUNDATION
PER GEOTECHNICAL REPORT PREPARED BY JACOBS ASSOCIATES DATED FEBRUARY 10, 2010 AND
SUBSEQUENT LETTER REPORTS.
DESIGN SOIL BEARING PRESSURES
SPREAD FOOTING............................................................................2000psf
ALL SLABS ON GRADE AND FOOTINGS SHALL BEAR ON COMPACTED GRANULAR FILL AS
SPECIFIED, MINIMUM THICKNESS 6 INCHES.
DEPTH OF FOOTING BELOW FINISHED GRADE — 18 INCHES MINIMUM.
DESIGN SOIL LATERAL PRESSURES
YIELDING WALL (ACTIVE PRESSURES)
DRAINED CONDITION........................................................................39H pcf
UNDRAINED CONDITION....................................................................93H pcf
SEISMIC CONDITION.......................................................................12.5H psf
PASSIVE PRESSURE
UNDRAINED CONDITION....................................................................510D pcf
COEFFICIENT OF BASE FRICTION.........................................................0.45
CONCRETE
ALL DETAILING, FABRICATION AND ERECTION OF REINFORCING BARS, UNLESS OTHERWISE NOTED,
SHALL BE IN ACCORDANCE WITH MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED
CONCRETE STRUCTURES ACI 315, LATEST EDITION. CONCRETE CONSTRUCTION SHALL CONFORM TO
ACI 318 BUILDING CODE, LATEST EDITION.
DESIGN STRENGTH
CAST —IN —PLACE CONCRETE UNLESS OTHERWISE NOTED
f'c = 4000 psi AT 28 DAYS (4000 CLASS A)
REINFORCING STEEL SHALL BE IN ACCORDANCE WITH ASTM A615, GRADE 60.
CONCRETE COVER
CONCRETE COVER FOR REINFORCING BARS SHALL BE AS FOLLOWS,
BUT NOT BE LESS THAN ONE BAR DIAMETER.
FOOTINGS "
CONCRETE IN CONTACT WITH SOIL OR WEATHER...................................2'
EXTRA ACCESSORY BARS
RIGIDLY SUPPORT BARS ON CONCRETE BLOCK OR APPROVED ACCESSORIES.
IN ADDITION, PROVIDE #5 RAISER BARS AT 36" ON CENTERS MAXIMUM TO SUPPORT TOP
REINFORCING STEEL IN SLABS.
DOWELS AND CORNER BARS
ALL HORIZONTAL BARS SHALL BE CONTINUOUS AROUND CORNERS. PROVIDE DOWELS AND
CORNER BARS FOR ALL WALL REINFORCEMENT, AT LEAST THE SAME SIZE AND SPACING AS
BARS WITH WHICH THEY ARE LAPPED. LAP SPLICES AND EMBEDMENT SHALL BE PER ACI 318,
OR AS NOTED.
PROVIDE TWO #5 VERTICAL BARS AT ALL WALL INTERSECTIONS AND AT ALL WALL ENDS.
BAR SPLICES
LAP REINFORCING STEEL BAR AS SHOWN ON PLANS. ALL LAP SPLICES NOT DIMENSIONED ON
THE PLANS SHALL BE 50 BAR DIAMETER. THE LENGTH OF LAP SPLICE OF BARS OF DIFFERENT
DIAMETER SHALL BE BASED ON THE SMALLER DIAMETER.
IN CASES WHERE REINFORCING BARS CANNOT BE EXTENDED AS FAR AS REQUIRED DUE TO THE
LIMITED EXTENT OF THE ADJACENT CONCRETE STRUCTURE, THE BARS SHALL EXTEND AS FAR
AS POSSIBLE AND END IN STANDARD HOOKS.
STEEL SHEET PILE
MATERIAL
ALL SHEET PILES SHALL CONFORM TO ASTM A328, fy=39ksi. CORNERS AND PILE CONNECTORS
SHALL CONFORM TO ASTM A572, GRADE 50.
PROVIDE CORNERS AND PILE CONNECTORS AS REQUIRED. SWING SHEET PILE AND/OR PRE —BEND
SHEETS AS REQUIRED AT RADIUSED WALL SEGMENT.
SECTION PROPERTIES
SECTION MODULUS, SMIN=18.OIN3
DEPTH, HMAx=101N
SPECIAL INSPECTION
THE FOLLOWING ITEMS REQUIRE SPECIAL INSPECTION PER IBC SECTION 1704.
CONCRETE CONCRETE WHICH IS PART OF THE STRUCTURE.
REINFORCING STEEL PLACEMENT OF REINFORCING STEEL
PILING SEE SPECIFICATONS FOR INSPECTING AND
TESTING PROCEDURES
SPECIAL GRADING, EXCAVATION * FOUNDATION EXCAVATIONS AND BEARING AND
FILLING STRATA.
* BACKFILL BEHIND STRUCTURAL WALLS OR
SUPPORTING SLAB —ON —GRADE.
BRIGHT ENGINEERING, INC.
STRUCTURAL & CIVIL ENGINEERING
1809 7TH AVENUE
SUITE 1100
SEATTLE, WA 98101
(206)625-3777
FAX: (206) 625-1851
BID
DOCUMENTS
CITY OF RENTON
�Jl
o Public Works Department
APPROVED FOR CONSTRUCTION /
/lla
BY: XX DATE: XX -
MISCELLANEOUS
REFER TO CIVIL DRAWINGS FOR SIZE AND LOCATION OF OPENINGS, PIPING, CONDUITS, EQUIPMENT
LOCATION AND ANCHORAGES, ETC., NOT SHOWN.
COORDINATE AND VERIFY ALL DIMENSIONS WITH CIVIL DRAWINGS AND VERIFY ALL. DIMENSIONS AND
CONDITIONS AT THE PROJECT SITE PRIOR TO STARTING WORK AND NOTIFY THE ENGINES;
IMMEDIATELY OF ANY DISCREPANCIES.
SUBMIT ALL REQUIRED SHOP DRAWINGS AND RECEIVE THEIR SATISFACTORY REVIEW FROM THE
ENGINEER, PRIOR TO FABRICATION.
STRUCTURAL SYSTEM HAS BEEN DESIGNED FOR OPERATIONAL LOADS ON THE COMPLETED
STRUCTURE. PROVIDE TEMPORARY ERECTION BRACING AND SHORING AS REQUIRED FOR STABILITY
OF THE STRUCTURE AND ADJACENT STRUCTURES, DURING ALL PHASES OF CONSTRUCTION.
REFER TO SPECIFICATIONS FOR INFORMATION NOT CONTAINED IN THESE GENERAL NOTES.
ABBREVIATIONS LOC LOCATION
LONGIT LONGITUDINAL
@ AT LP LOW POINT
NE EPDXY COATED BARS MAX MAXIMUM
BOT BOTTOM MIN MINIMUM
BRIG BEARING MISC MISCELLANEOUS
CJ CONSTRUCTION JOINT N/A NOT APPLICABLE
CL, CENTER LINE NF NEAR FACE
CLR CLEAR NTS NOT TO SCALE
CONIC CONCRETE
CONT CONTINUOUS OC ON CENTER, CENTERS
OD OUTSIDE DIAMETER
DIA DIAMETER OF OUTSIDE FACE
DWG DRAWING OPNG OPENING
OPP OPPOSITE
FA EACH
TIFF EACH FACE PSF POUNDS PER SQUARE FOOT
L ELEVATION PSI POUNDS PER SQUARE INCH
S EACH SIDE
W EACH WAY R RADIUS
EXIST EXISTING REBAR REINFORCEMENT BAR
REF REFER TO / REFERENCE
FDN FOUNDATION REINF REINFORCEMENT OR REINFORCING
FT FEET OR FOOT REQD REQUIRED
FTG FOOTING
SECT SECTION
HORIZ HORIZONTAL. SHT SHEET
HP HIGH POINT SIM SIMILAR
SPCG SPACING
ID INSIDE DIAMETER STD STANDARD
IE INVERT ELEVATION
IF INSIDE FACE TYP TYPICAL
IN INCH
INFO INFORMATION UNO UNLESS NOTED OTHERWISE
JT JOINT VERT VERTICAL
KSI KIPS PER SQUARE INCH ws/ VOTH
WP WORK POINT
L LENGTH OR ANGLE WSDOT WASHINGTON STATE
LB POUND DEPT OF TRANSPORTATION
T 343036
LEGEN D
DESIGNATION
SECTIONrx
(LETTER)
SCALE: x
DRAWING NUMBER OF SHEE-
WHERE THE SECTION IS SHC
(DASH IF ON SAME SHEET) DESIGNATION
DETAILa
(LETTER)
DETAIL
DESIGNATION
(NUMBER)--
t 1I
SCALE: x x DRAWING NUMBER OF SHEET
DRAWING NUMBER OF SHEE-
WHERE THE DETAIL IS SHOO
(DASH IF ON SAME SHEET)
WHERE THE SECTION IS SHOWN
(DASH IF ON SAME SHEET) --
DRAWING NUMBER OF SHEET
WHERE THE SECTION IS SHOWN
(DASH IF ON SAME SHEET)
X/XX
SECTION
DESIGNATION
(LETTER) SECTION C U T
RAINIER AVENUE S (SR 167)
S G RA DY WAY TO S 2 N D ST
STRUCTURAL NOTES, ABBREVIATIONS, LEGEND
AND CONCRETE WALL DETAILS
c
D
C .
D G D
a �.
CONCRETE
..
e `' 1 a r/r t R I H
GROUT
36__
DRAWING NO.
PROJECT NO.
TED403430
FED AID NO.
-CM0167(048)
DATE:
NOV 2011
SHEET NO. 36 OF 304