Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
TRO4103430.89
LEGEND 6 CD 0 LH N 0 N �r N 0 J 0 Ln Ln 0 T Cn i 0 0 I 0 w / Cn U O w Cn Cn U 0 0 CD I EXISTING NEW DENOTES EX. O is POLE DECAL# xxxx __co DESCRIPTION SIGNAL POLE WITH MAST ARM TYPE I OR PS POLE EXISTING LUMINAIRE DECORATIVE PEDESTRIAN LUMINAIRE DECORATIVE ROADWAY LUMINAIRE DECORATIVE PEDESTRIAN/ROADWAY LUMINAIRE SIGNAL CONTROLLER CABINET ELECTRICAL SERVICE CABINET ITS CABINET JUNCTION BOX TYPE 1, 2, 8 25-TA VAULT CONDUIT WIRE NOTE CONSTRUCTION NOTE G� 4 � 4 � � 1 SR167 10 3590C GENERAL NOTES 9 1. ALL WORK SHALL BE DONE WITH WSDOT STANDARD PLANS & SPECIFICATIONS AND THE LATEST AMENDMENTS, APWA STANDARDS, THE 13 10 7 8 10 CITY DEVELOPMENTAL GUIDELINES AND THESE PLANS. 2. UTILITY LOCATION (DIAL -A -DIG) PRIOR TO CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. CONFLICTS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION. 3. CONTRACTOR SHALL COORDINATE WITH POWER COMPANY REGARDING THE ELECTRICAL SERVICE CONNECTION. CONTRACTOR SHALL MEET WITH 13 17 11 4 4 10 5 PUGET SOUND ENERGY REPRESENTATIVE SHERI CLARKE AT (425) 456-2701 PRIOR TO INSTALLATION OF METER BASE. 4. THE LOCATION OF' A! L FEATURES TO BE INSTALLED BY THE CONTRACTOR / SHALL BE VERIFIED IN FIELD BY THE ENGINEER PRIOR TO INSTALLATION. 5. ALL NEW JUNCTION BOXES INSTALLED IN SIDEWALKS SHALL HAVE SKID _ _ = 13 \ 13� 2 � 13 RESISTANT LIDS. ALL JUNCTION BOXES SHALL HAVE LOCKING LIDS PER — — COR STD PLAN #127.,� 6. CONDUIT LOCATIONS ARE SHOWN FOR REFERENCE ONLY. FINAL TO EXISTING WSDOT LOCATIONS SHALL BE DETERMINED BY THE CONTRACTOR AND APPROVED 7 LIGHTING POWER SOURCE BY THE ENGINEER IN THE FIELD. 7. NUMBER OF CONDUIT BENDS BETWEEN PULL POINTS SHALL NOT BE MORE / THAN THE EQUIVALENT OF FOUR QUARTER BENDS (360 DEGREES TOTAL). IF NUMBER OF BENDS EXCEEDS 360 DEGREES, THE CONTRACTOR SHALL INSTALL ADDITIONAL JUNCTION BOXES, AS REQUIRED. 8. ILLUMINATION SHALL BE MAINTAINED DURING CONSTRUCTION IN ACCORDANCE WITH SECTION 8-20.3(1)A OF THE SPECIFICATIONS. THE CONTRACTOR IS ALSO RESPONSIBLE FOR MAINTAINING 10' CLEARANCE ZONE AROUND EXISTING AERIAL PRIMARY POWER LINES DURING THE /P CONSTRUCTION. COORDINATE WORK WITH THE POWER COMPANY REPRESENTATIVE. 9. FOR LOCATIONS OF PRIVATE LUMINAIRES TO BE REMOVED, SEE SITE 1 PREPARATION PLANS. GRIND DOWN EXISTING FOUNDATION TO 2' BELOW PROPOSED GRADE AND CAP AND ABANDON EXISTING UNUSED CONDUIT. SPLICE EXISTING WIRING IF NECESSARY TO MAINTAIN CONNECTIONS TO EXISTING PRIVATE LUMINAIRES TO REMAIN. BACKFILL AND COMPACT ALL VOIDS PER SPECIAL PROVISIONS. LUMINAIRE SCHEDULE (ELECTRICAL SERVICE CABINET "S1" - FOR CIRCUIT AND PANEL SCHEDULES SEE SHEET 238) 129H RAINIER AVE S R/W 2r • N L.J W co 6131 0 0 N Q r� 1 Lj z U Q WIRE NOTES ®I RACEWAY/I CONDUIT SIZE CONDUCTORS COMMENTS 1 2" 2#8 SEE NOTES BELOW 2 2" 4#8 SEE NOTES BELOW 3 2" 6#8 SEE NOTES BELOW 4 4" SPARE 5 6 4" 2" 1-96 SMFO - -- - --- -- - - ---; SEE SEE NOTES NOTES BELOW BELOW 7 EX. SEE NOTES BELOW 8 4" EX. 1-48 SMFO RE-ROUITE NOTES: 1. ALL CONDUIT CONTAINING CONDUCTORS SHALL HAVE MIN 1-#8 GROUND WIRE (UNLESS GROUND WIRE SIZE IS SPECIFIED IN THE WIRE SCHEDULE OTHERWISE). SPARE CONDUIT SHALL CONTAIN BULL -LINE TAPE AND LABELED "CITY OF RENTON". 2. ALL SIGNAL AND LIGHTING CONDUIT SHALL BE RIGID PVC SCH 40, EXCEPT UNDER ROADWAY USE RIGID PVC SCH 80. ALL FIBER CONDUIT AND SPARE 4" CONDUIT SHALL BE RIGID PVC SCH 80 WITH FLEXIBLE FABRIC INNERDUCT INSTALLED PER SPECIFICATIONS. \ 10 \ 6 1 2 5 1 3 1 3 14 ' 13 A3 5 3 s. 25-TA 3 — 0 5 10 20 40 60 .001 �- 1 SCALE IN FEET � � 3 SER CE "S —' —' SEE SIGNAL PLAN 10 ° 13 FOR DETAILS T=3430168 9 0 CONSTRUCTION NOTES 13 , O CONSTRUCT LUMINAIRE POLE FOUNDATION PER ILLUMINATION DETAILS SHEET 239. FURNISH AND INSTALL DECORATIVE LUMINAIRE, / 1 POLE, ARM, CONDUIT/WIRING ALL ASSOCIATED EQUIPMENT AND APPLY DECAL NUMBERING TO LUMINAIRE POLES. FOR ADDITIONAL /L4— / INSTALLATION DETAILS SEE ILLUMINATION SHEET 239, COR STANDARD DRAWINGS J007, J008, J009, J013, J015 AND SPECIAL PROVISIONS. {, O REMOVE EXISTING LUMINAIRE POLE, LUMINAIRE, JUNCTION BOX, WIRING AND CAP AND ABANDON EXISTING UNUSED CONDUIT. GRIND 1 DOWN EXISTING FOUNDATION 2' BELOW PROPOSED GRADE. BACKFILL AND COMPACT ALL VOIDS PER SPECIAL PROVISIONS. ( / SALVAGE CITY OWNED POLE AND LUMINAIRE PER SPECIAL PROVISIONS. OCONSTRUCT FOUNDATION PER DETAILS ON SHEET 263 AND FURNISH AND INSTALL ELECTRICAL SERVICE CABINET PER COR STD DWGS J010 AND J011 WITH BACK-TO-BACK BATTERY BACKUP SYSTEM PER SPECIAL PROVISIONS. FOR LOCATION AND PANEL Q` SCHEDULE, SEE ILLUMINATION CIRCUIT DIAGRAM AND DETAILS SHEET 238. COORDINATE CONNECTION DETAILS TO THE POWER 17 / SOURCE WITH THE POWER COMPANY REPRESENTATIVE PRIOR TO INSTALLATION OF FOUNDATION. SEE SPECIAL PROVISIONS. 10 0 EXISTING LUMINAIRE TO REMAIN. MAINTAIN CIRCUIT CONTINUITY DURING CONSTRUCTION. 999G 4 13 10 4 N TO EXISTING CITY LIGHTING POWER SOURCE �i 70 EXISTING SIGNAL POLE MOUNTED LUMINAIRE. FOR REMOVAL NOTES SEE SIGNAL PLANS. ® SEE SIGNAL PLANS FOR CONSTRUCTION NOTES REGARDING INSTALLATION OF ADDITIONAL SIGNAL SYSTEM EQUIPMENT. O9 FOR REMOVAL/RELOCATION OF ADDITIONAL SIGNAL SYSTEM EQUIPMENT SEE SIGNAL PLANS. 10 FOR EXISTING JUNCTION BOX REMOVAL/MODIFICATION CONSTRUCTION NOTES SEE SIGNAL PLANS. 11 EXISTING JUNCTION BOX TO REMAIN. PROTECT EXISTING WIRING DURING CONSTRUCTION. 13 SEE WIRE SCHEDULE ON SIGNAL PLANS FOR CONDUIT CONTAINING SIGNAL WIRING. INSTALL 1" GRS CONDUIT FROM JUNCTION BOX TO BUS SHELTER FOOTING. REFER TO METRO STANDARDS FOR CONSTRUCTION OF 14 TRANSIT PASSENGER FACILITIES AND DETAILS, SHEET 27 FOR CONDUIT STUB LOCATION. 17 INSTALL NEW TYPE 8 TRAFFIC RATED JUNCTION BOX. LID SHALL BE LABELED "ITS". ©0 SEE URBAN DESIGN PLAN SHEETS FOR CONTINUATION OF ARCHITECTURAL LIGHTING. BID DOCUMENTS ADDENDUM #2, REVISED PULL BOX LOCATION JJA JF 12-16-11 Fq 11-14-11 SURVEYED: KPG K]PIC11�- CITY OF RENTON RAINIER AVENUES (SR 167) DRAWING No. 228 -yam DRAWN BY: JM S GRADY WAY TO S 2ND ST PROJECT NO. TED403430 0��' DESIGN BY: JF Public Works Department F E H R �z PEERS 753 9th Ave N 2502 Jefferson Ave FED AID NO. CM0167(048) TRANSPORTATION CONSULTANTS WA98402 ILLUMINATION AND INTERCONNECT PLAN CHECK BY: JF Seattle WA 98109 Tacoma APPR FOR CONSTRUCTION DATE: NOV 2011 Walnut Ge�c. CA ° Orflrige Casty. CA 46 4 �, 10014th Avenue, ° Roee 11 CA ° Los "' as h. CA (206) 286-1640 (253) 627-0720 01 TERF���1�v PROJMGR: TN Suite4120 �snFflncIsaAo.cA osacoegaCA -- T Ssi N� Seattle. WA 98154 oSaar ento.CA °Rero.NV www,kpg,com BY: DATE: STA 8+98 TC STA 12+00 SHEET NO. 228 OF 304 NUMBER REVISION DESCRIPTION BY APP. DATE oNAuE g (206)576-4220 °Seattle. WA °De ar.CO L�� f2' FILE: 0655DILL01.dw LUMINAIRE # STATION OFFSET LUMINAIRE TYPE LUMINAIRE ARM MOUNTING HEIGHT POLE TYPE CIRCUIT # DECAL # COMMENTS Al * �, DECORATIVE 135W LED (M-II-FC) 240V _ A 7697N SEE SIGNAL PLANS FOR INFORMATION NOT SHOWN A2 _ _ _ * _ "DECORATIVE" 135W LED (M-II-FC) 240V * * * A 7696N * SEE SIGNAL PLANS FOR INFORMATION NOT SHOWN A3 * * ! "DECORATIVE" 135W LED (M-II-FC) 240V W/ PHOTOCELL * * * A 7699N * SEE SIGNAL PLANS FOR INFORMATION NOT SHOWN 1 RAINIER AVE S, STA 10+33 51.5' LT "DECORATIVE" 135W LED (M-II-FC) 240V 6' 35' 40' A 7698N SERVICE #S1 1 A RAINIER AVE S, STA 9+50 64.2' LT "DECORATIVE" 135W LED (M-II-FC) 240V 6' 35' 40' A - SERVICE #S1 1 B RAINIER AVE S, STA 10+61 62.8' RT "DECORATIVE" 80W LED (S-IV-FC) 240V 6' 35' 40' A - SERVICE #S1 2 RAINIER AVE S, STA 10+80 56.0' LT "DECORATIVE" 135W LED (M-III-FC) 240V 6' 35' 40' B 770ONL SERVICE #S1 3 RAINIER AVE S, STA 11+71 53.5' RT "DECORATIVE" 135W LED (M-II-FC) 240V 6' 35' 40' B 7701NL SERVICE #S1 P1 SHARED POLE "DECORATIVE" 60W LED (S-III-FC) 240V 4' 14' 40' D 770ONL SERVICE #S1 P2 RAINIER AVE S, STA 11+42 51.5' LT "DECORATIVE" 60W LED (S-III-FC) 240V 4' 14' 18' D 7702L SERVICE #S1 P3 SHARED POLE "DECORATIVE" 60W LED (S-III-FC) 240V 4' 14' 40' D 7701 NL SERVICE #S1