Loading...
HomeMy WebLinkAboutTRO4103430.91LL 0 Li� N O N cll_� Z_ 0 0 Ln Ln QD 0 / 0 U E / CD 0 i Cn CD w Cf) U Q� 0 CL II cn Cn U a� 0 n 0 CD L_ulrlll14nll.L_ STATION OFFSET LUMINAIRE TYPE LuI�RMRULL Ic 'V'HEIGHTV TYPE vlf`\J" v COMMENTS 10 RAINIER AVE S, STA 15+70 53.5' LT "DECORATIVE" 135W LED (M-11-FC) 240V 12 35' 40' B 7714NL SERVICE #S1 11 RAINIER AVE S, STA 16+60 53.5' RT "DECORATIVE" 135W LED (M-11-FC) 240V 6' 35' 40' B 7715NL SERVICE #S1 12 RAINIER AVE S, STA 16+58 47.0' LT "DECORATIVE" 135W LED (M-11-FC) 240V 6' 35' 40' C 7716NL SERVICE #S1 P14 SHARED POLE "DECORATIVE" 60W LED (S-111-FC) 240V 4' 14' 40' D 7714NL SERVICE _ #S1 P15 RAINIER AVE S, STA 15+93 53.5' RT "DECORATIVE" 60W LED (S-111-FC) 240V 4' 14' 18' D 7717NL SERVICE #S1 P16 SHARED POLE "DECORATIVE" 60W LED (S-111-FC) 240V 4' 14' 40' D 7716NL SERVICE #S1 P17 SHARED POLE "DECORATIVE" 60W LED (S-111-FC) 240V 4' 14' 40' D 7715NL SERVICE #S1 13 RAINIER AVE S, STA 17+52 48.5' LT "DECORATIVE" 135W LED (M-11-FC) 240V _ 6' 35' _ 40' B 7718NL SERVICE #S2 _ 14 RAINIER AVE S, STA 18+17 57.5' RT "DECORATIVE" 135W LED (M-11-FC) 240V 12' 35' 40' C 7719N SERVICE #S2 _ 15 RAINIER AVE__ S, STA 18+93 53.0' LT "DECORATIVE" 135W LED(M-II-FC) 240V 6' 35' 40' C 7720NL SERVICE #S2 16 RAINIER AVE S, STA 19+66 57.0' RT "DECORATIVE" 135W LED (M-11-FC) 240V 12' 35' 40' B 7721 N SERVICE #S2 P18 SHARED POLE "DECORATIVE" 60W LED (S-111-FC) 240V 4' 14' 40' D 7718NL SERVICE #S2 P19 RAINIER AVE S, STA 17+37 53.3' RT "DECORATIVE" 60W LED (S-111-FC) 240V 4' 14' 18' D 7723L SERVICE #S2 P20 RAINIER AVE S, STA 18+21 51.0' LT "DECORATIVE" 60W LED (S-111-FC) 240V 4' 14' 18' D 7724L SERVICE #S2 P21 SHARED POLE "DECORATIVE" 60W LED (S-111-FC) 240V 4' 14' 40' D 7720NL SERVICE _ #S2 P22 RAINIER AVE S, STA 19+90 153.51 LT ff DECORATIVEff 60W LED S-III-FC 240V 41 14' 181 D 7726L SERVICE - #S2 CONSTRUCTIONCON,STRUCTION NOTES O CONSTRUCT LUMINAIRE POLE FOUNDATION PER ILLUMINATION DETAILS SHEET 239. FURNISH AND INSTALL DECORATIVE LUMINAIRE, POLE, ARM, CONDUIT/WIRING ALL ASSOCIATED EQUIPMENT AND APPLY DECAL NUMBERING TO LUMINAIRE POLES. FOR ADDITIONAL INSTALLATION DETAILS SEE ILLUMINATION SHEET 239, COR STANDARD DRAWINGS J007, J0081 J0091 J013, J015 AND SPECIAL PROVISIONS. ® REMOVE EXISTING LUMINAIRE POLE, LUMINAIRE, JUNCTION BOX, WIRING AND CAP AND ABANDON EXISTING UNUSED CONDUIT. GRIND 2 DOWN EXISTING FOUNDATION 2' BELOW PROPOSED GRADE. BACKFILL AND COMPACT ALL VOIDS PER SPECIAL PROVISIONS. SALVAGE CITY OWNED POLE AND LUMINAIRE PER SPECIAL PROVISIONS. <D EXISTING LUMINAIRE TO REMAIN. MAINTAIN CIRCUIT CONTINUITY DURING CONSTRUCTION. < > 1 �8 SEE SIGNAL PLANS FOR CONSTRUCTION NOTES REGARDING INSTALLATION OF ADDITIONAL SIGNAL SYSTEM EQUIPMENT. 12 REMOVE EXISTING JUNCTION BOX AND COMPACT AND BACKFILL VOID PER SPECIAL PROVISIONS. REMOVE EXISTING UNUSED WIRING AND CAP AND ABANDON EXISTING UNUSED CONDUIT. 13 SEE WIRE SCHEDULE ON SIGNAL PLANS FOR CONDUIT CONTAINING SIGNAL WIRING. 14 INSTALL 1" GRS CONDUIT FROM JUNCTION BOX TO BUS SHELTER FOOTING. REFER TO METRO STANDARDS FOR CONSTRUCTION OF TRANSIT PASSENGER FACILITIES AND DETAILS, SHEET 27 FOR CONDUIT STUB LOCATION. 17 INSTALL NEW TYPE 8 TRAFFIC RATED JUNCTION BOX. LID SHALL BE LABELED "ITS". ADDENDUM #2, REMOVED PRIVATE POLE REMOVAL NOTES JJA JF 12-16-11 11-14-11 pF • WA Sy� S I NUMBER I REVISION DESCRIPTION -O 46 4 /�FG 1 T F_ AS/ENG\ BY APP. DATE SoNAL SURVEYED: KPG DRAWN BY: JM DESIGN BY: JF CHECK BY: JF PROJ MGR: TN FILE: 0655DILL01.dwg f? FEHR & PEERS TRANSPORTATION CONSULTANTS 1001 4th Avenue, o Walnut Creek CA - Orange County. CA o Roseville. CA ❑ Los Arles County, CA Suite 4120 - San Jose. CA - San Dlego, CA Seattle, WA 98154 ° San Francisco. CA a Salt Lake City, UT (206) 576-4220 - Sacramento. CA o Reno. NV Seattle, WA - Denver. CO WIRE NOTES iRACEWAY/ CONDUIT SILL CONDUCTORS 2#8 SEE COMMENTS NOTES BELOW , 1 2" 2 2" 4#8 SEE NOTES BELOW 3 4 2" 4ff 6#8 ! SEE NOTES Sa AR 4: BELl 5 4ff 1-96 SMFO °SEE NO E ; BELOW 6 2" SEE NOTES BELOW 7 EX. SEE NOTES BELOW 8 4" EX. 1-48 SMFO RE—ROUTE NOTES: 1. ALL CONDUIT CONTAINING CONDUCTORS SHALL HAVE MIN 1—#8 GROUND WIRE (UNLESS GROUND WIRE SIZE IS SPECIFIED IN THE WIRE SCHEDULE OTHERWISE). SPARE CONDUIT SHALL CONTAIN BULL —LINE TAPE AND LABELED "CITY OF RENTON". 2. ALL SIGNAL AND LIGHTING CONDUIT SHALL BE RIGID PVC SCH 40, EXCEPT UNDER ROADWAY USE RIGID PVC SCH 80. =. FIBER C0NDt)IT, AND SPARE 4" CONDUIT SHALL BE RIGID PVC SUCH 80 WITH FLEXIBLE FABRIC INNERDUCT INSTALLED PER SPECIFICATIONS. 3430170 GENERAL NOTES 1. ALL WORK SHALL BE DONE WITH WSDOT STANDARD PLANS & SPECIFICATIONS AND THE LATEST AMENDMENTS, APWA STANDARDS, THE LEGEND CITY DEVELOPMENTAL GUIDELINES AND THESE PLANS. EXISTING NEW DESCRIPTION 2. UTILITY LOCATION (DIAL -A -DIG) PRIOR TO CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. CONFLICTS SHALL BE BROUGHT =- SIGNAL POLE WITH MAST ARM TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION. 3. CONTRACTOR SHALL COORDINATE WITH POWER COMPANY REGARDING THE DENo'rEs Ex. ����� ® TYPE I OR PS POLE ELECTRICAL SERVICE CONNECTION. CONTRACTOR SHALL MEET WITH PALE DECAL # xxxx PUGET SOUND ENERGY REPRESENTATIVE SHERI CLARKE AT (425) o EXISTING LUMINAIRE 456 2701 PRIOR TO INSTALLATION OF METER BASE. DECORATIVE PEDESTRIAN LUMINAIRE 4. THE LOCATION OF ALL FEATURES TO BE INSTALLED BY THE CONTRACTOR SHALL BE VERIFIED IN FIELD BY THE ENGINEER PRIOR TO INSTALLATION. 5. ALL NEW JUNCTION BOXES INSTALLED IN SIDEWALKS SHALL HAVE SKID &_0 DECORATIVE ROADWAY LUMINAIRE RESISTANT LIDS. ALL JUNCTION BOXES SHALL HAVE LOCKING LIDS PER 0__E�_o DECORATIVE PEDESTRIAN/ROADWAY LUMINAIRE COR STD PLAN ,127. 6. CONDUIT LOCATIONS ARE SHOWN FOR REFERENCE ONLY. FINAL m SIGNAL CONTROLLER CABINET LOCATIONS SHALL BE DETERMINED BY THE CONTRACTOR AND APPROVED BY THE ENGINEER IN THE FIELD. ® ELECTRICAL SERVICE CABINET 7. NUMBER OF CONDUIT BENDS BETWEEN PULL POINTS SHALL NOT BE MORE THAN THE EQUIVALENT OF FOUR QUARTER BENDS (360 DEGREES TOTAL). OEM ITS CABINET IF NUMBER OF BENDS EXCEEDS 360 DEGREES, THE CONTRACTOR SHALL INSTALL ADDITIONAL JUNCTION BOXES, AS REQUIRED. m ®� JUNCTION BOX TYPE 1, 2, 8 8. ILLUMINATION SHALL BE MAINTAINED DURING CONSTRUCTION IN 25—TA 25—TA VAULT ACCORDANCE WITH SECTION 8---20.3(1)A OF .I HE SPEC IFICA �yIONS. THE %CONTRACTOR IS ALSO RESPONSIBLE FOR MAINTAINING 10' CLEARANCE ®- - — CONDUIT ZONE AROUND EXISTING AERIAL PRIMARY POWER LINES DURING THE CONSTRUCTION. COORDINATE WORK WITH THE POWER COMPANY WIRE NOTE REPRESENTATIVE. o CONSTRUCTION NOTE 9. FOR LOCATIONS OF PRIVATE LUMINAIRES TO BE REMOVED, SEE SITE 1 PREPARATION PLANS. GRIND DOWN EXISTING FOUNDATION TO 2, BELOW PROPOSED GRADE AND CAP AND ABANDON EXISTING UNUSED CONDUIT. SPLICE EXISTING WIRING IF NECESSARY TO MAINTAIN CONNECTIONS TO EXISTING PRIVATE LUMINAIRES TO REMAIN. BACKFILL AND COMPACT ALL VOIDS PER SPECIAL PROVISIONS. /5 10 20 40 .! SCALE IN FEET BID DOCUMENTS CITY OF RENTON RAINIER AVENUE S (SR 167) DRAWING No. 230 S G RADY WAY TO S 2N D ST PROJECT NO. TED403430 753 9th Ave N 2502 Jefferson Ave Public Works D e p a r t m e n t FED AID NO. CM0167(04p) Seattle, WA 98109 Tacoma, WA 98402 ILLUMINATION AND INTERCONNECT PLAN (206) 286-1640 (253) 627-0720 APPROVES? FOR CONSTRUCTION DATE; _ NOV 2'_,01 1_ www.kpg.com BY: / DATE /lip ��r STA 1 5+50 TO STA 20+00 � SHEET NO. 230 _ OF _ 0 fy ,