HomeMy WebLinkAboutTRO4103430.91LL
0
Li�
N
O
N
cll_�
Z_
0
0
Ln
Ln
QD
0
/
0
U
E
/
CD
0
i
Cn
CD
w
Cf)
U
Q�
0
CL
II
cn
Cn
U
a�
0
n
0
CD
L_ulrlll14nll.L_
STATION
OFFSET
LUMINAIRE TYPE
LuI�RMRULL
Ic
'V'HEIGHTV
TYPE
vlf`\J" v
COMMENTS
10
RAINIER AVE S,
STA
15+70
53.5'
LT
"DECORATIVE"
135W
LED
(M-11-FC)
240V
12
35'
40'
B
7714NL
SERVICE
#S1
11
RAINIER AVE S,
STA
16+60
53.5'
RT
"DECORATIVE"
135W
LED
(M-11-FC)
240V
6'
35'
40'
B
7715NL
SERVICE
#S1
12
RAINIER AVE S,
STA
16+58
47.0'
LT
"DECORATIVE"
135W
LED
(M-11-FC)
240V
6'
35'
40'
C
7716NL
SERVICE
#S1
P14
SHARED
POLE
"DECORATIVE"
60W
LED
(S-111-FC)
240V
4'
14'
40'
D
7714NL
SERVICE
_
#S1
P15
RAINIER AVE S,
STA
15+93
53.5'
RT
"DECORATIVE"
60W
LED
(S-111-FC)
240V
4'
14'
18'
D
7717NL
SERVICE
#S1
P16
SHARED
POLE
"DECORATIVE"
60W
LED
(S-111-FC)
240V
4'
14'
40'
D
7716NL
SERVICE
#S1
P17
SHARED
POLE
"DECORATIVE"
60W
LED
(S-111-FC)
240V
4'
14'
40'
D
7715NL
SERVICE
#S1
13
RAINIER AVE S,
STA
17+52
48.5'
LT
"DECORATIVE"
135W
LED
(M-11-FC)
240V
_ 6'
35'
_
40'
B
7718NL
SERVICE
#S2
_
14
RAINIER AVE S,
STA
18+17
57.5'
RT
"DECORATIVE"
135W
LED
(M-11-FC)
240V
12'
35'
40'
C
7719N
SERVICE
#S2
_
15
RAINIER AVE__ S,
STA
18+93
53.0'
LT
"DECORATIVE"
135W
LED(M-II-FC)
240V
6'
35'
40'
C
7720NL
SERVICE
#S2
16
RAINIER AVE S,
STA
19+66
57.0'
RT
"DECORATIVE"
135W
LED
(M-11-FC)
240V
12'
35'
40'
B
7721 N
SERVICE
#S2
P18
SHARED
POLE
"DECORATIVE"
60W
LED
(S-111-FC)
240V
4'
14'
40'
D
7718NL
SERVICE
#S2
P19
RAINIER AVE S,
STA
17+37
53.3'
RT
"DECORATIVE"
60W
LED
(S-111-FC)
240V
4'
14'
18'
D
7723L
SERVICE
#S2
P20
RAINIER AVE S,
STA
18+21
51.0'
LT
"DECORATIVE"
60W
LED
(S-111-FC)
240V
4'
14'
18'
D
7724L
SERVICE
#S2
P21
SHARED
POLE
"DECORATIVE"
60W
LED
(S-111-FC)
240V
4'
14'
40'
D
7720NL
SERVICE
_
#S2
P22
RAINIER AVE S,
STA
19+90
153.51
LT
ff DECORATIVEff
60W
LED
S-III-FC
240V
41
14'
181
D
7726L
SERVICE
-
#S2
CONSTRUCTIONCON,STRUCTION NOTES
O CONSTRUCT LUMINAIRE POLE FOUNDATION PER ILLUMINATION DETAILS SHEET 239. FURNISH AND INSTALL DECORATIVE LUMINAIRE,
POLE, ARM, CONDUIT/WIRING ALL ASSOCIATED EQUIPMENT AND APPLY DECAL NUMBERING TO LUMINAIRE POLES. FOR ADDITIONAL
INSTALLATION DETAILS SEE ILLUMINATION SHEET 239, COR STANDARD DRAWINGS J007, J0081 J0091 J013, J015 AND SPECIAL
PROVISIONS.
® REMOVE EXISTING LUMINAIRE POLE, LUMINAIRE, JUNCTION BOX, WIRING AND CAP AND ABANDON EXISTING UNUSED CONDUIT. GRIND
2
DOWN EXISTING FOUNDATION 2' BELOW PROPOSED GRADE. BACKFILL AND COMPACT ALL VOIDS PER SPECIAL PROVISIONS.
SALVAGE CITY OWNED POLE AND LUMINAIRE PER SPECIAL PROVISIONS.
<D EXISTING LUMINAIRE TO REMAIN. MAINTAIN CIRCUIT CONTINUITY DURING CONSTRUCTION.
< >
1
�8 SEE SIGNAL PLANS FOR CONSTRUCTION NOTES REGARDING INSTALLATION OF ADDITIONAL SIGNAL SYSTEM EQUIPMENT.
12 REMOVE EXISTING JUNCTION BOX AND COMPACT AND BACKFILL VOID PER SPECIAL PROVISIONS. REMOVE EXISTING UNUSED WIRING
AND CAP AND ABANDON EXISTING UNUSED CONDUIT.
13 SEE WIRE SCHEDULE ON SIGNAL PLANS FOR CONDUIT CONTAINING SIGNAL WIRING.
14 INSTALL 1" GRS CONDUIT FROM JUNCTION BOX TO BUS SHELTER FOOTING. REFER TO METRO STANDARDS FOR CONSTRUCTION OF
TRANSIT PASSENGER FACILITIES AND DETAILS, SHEET 27 FOR CONDUIT STUB LOCATION.
17 INSTALL NEW TYPE 8 TRAFFIC RATED JUNCTION BOX. LID SHALL BE LABELED "ITS".
ADDENDUM #2, REMOVED PRIVATE POLE REMOVAL NOTES JJA JF 12-16-11 11-14-11
pF • WA Sy� S
I NUMBER I REVISION DESCRIPTION
-O 46 4
/�FG 1 T F_
AS/ENG\
BY APP. DATE SoNAL
SURVEYED:
KPG
DRAWN BY:
JM
DESIGN BY:
JF
CHECK BY:
JF
PROJ MGR:
TN
FILE: 0655DILL01.dwg
f?
FEHR
& PEERS
TRANSPORTATION CONSULTANTS
1001 4th Avenue,
o Walnut Creek CA - Orange County. CA
o Roseville. CA ❑ Los Arles County, CA
Suite 4120
- San Jose. CA - San Dlego, CA
Seattle, WA 98154
° San Francisco. CA a Salt Lake City, UT
(206) 576-4220
- Sacramento. CA o Reno. NV
Seattle, WA - Denver. CO
WIRE NOTES
iRACEWAY/
CONDUIT
SILL
CONDUCTORS
2#8
SEE
COMMENTS
NOTES
BELOW ,
1
2"
2
2"
4#8
SEE
NOTES
BELOW
3
4
2"
4ff
6#8
! SEE NOTES
Sa AR 4:
BELl
5
4ff
1-96 SMFO
°SEE
NO E ;
BELOW
6
2"
SEE
NOTES
BELOW
7
EX.
SEE
NOTES
BELOW
8
4"
EX. 1-48 SMFO
RE—ROUTE
NOTES:
1. ALL CONDUIT CONTAINING CONDUCTORS SHALL HAVE MIN 1—#8
GROUND WIRE (UNLESS GROUND WIRE SIZE IS SPECIFIED IN THE WIRE
SCHEDULE OTHERWISE). SPARE CONDUIT SHALL CONTAIN BULL —LINE
TAPE AND LABELED "CITY OF RENTON".
2. ALL SIGNAL AND LIGHTING CONDUIT SHALL BE RIGID PVC SCH 40,
EXCEPT UNDER ROADWAY USE RIGID PVC SCH 80. =. FIBER C0NDt)IT,
AND SPARE 4" CONDUIT SHALL BE RIGID PVC SUCH 80 WITH FLEXIBLE
FABRIC INNERDUCT INSTALLED PER SPECIFICATIONS.
3430170
GENERAL NOTES
1.
ALL WORK SHALL BE DONE WITH WSDOT STANDARD PLANS &
SPECIFICATIONS AND THE LATEST AMENDMENTS, APWA STANDARDS, THE
LEGEND
CITY DEVELOPMENTAL GUIDELINES AND THESE PLANS.
EXISTING
NEW
DESCRIPTION
2.
UTILITY LOCATION (DIAL -A -DIG) PRIOR TO CONSTRUCTION SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR. CONFLICTS SHALL BE BROUGHT
=-
SIGNAL POLE WITH MAST ARM
TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION.
3.
CONTRACTOR SHALL COORDINATE WITH POWER COMPANY REGARDING THE
DENo'rEs Ex. �����
®
TYPE I OR PS POLE
ELECTRICAL SERVICE CONNECTION. CONTRACTOR SHALL MEET WITH
PALE DECAL #
xxxx
PUGET SOUND ENERGY REPRESENTATIVE SHERI CLARKE AT (425)
o
EXISTING LUMINAIRE
456 2701 PRIOR TO INSTALLATION OF METER BASE.
DECORATIVE PEDESTRIAN LUMINAIRE
4.
THE LOCATION OF ALL FEATURES TO BE INSTALLED BY THE CONTRACTOR
SHALL BE VERIFIED IN FIELD BY THE ENGINEER PRIOR TO INSTALLATION.
5.
ALL NEW JUNCTION BOXES INSTALLED IN SIDEWALKS SHALL HAVE SKID
&_0
DECORATIVE ROADWAY LUMINAIRE
RESISTANT LIDS. ALL JUNCTION BOXES SHALL HAVE LOCKING LIDS PER
0__E�_o
DECORATIVE PEDESTRIAN/ROADWAY LUMINAIRE
COR STD PLAN ,127.
6.
CONDUIT LOCATIONS ARE SHOWN FOR REFERENCE ONLY. FINAL
m
SIGNAL CONTROLLER CABINET
LOCATIONS SHALL BE DETERMINED BY THE CONTRACTOR AND APPROVED
BY THE ENGINEER IN THE FIELD.
®
ELECTRICAL SERVICE CABINET
7.
NUMBER OF CONDUIT BENDS BETWEEN PULL POINTS SHALL NOT BE MORE
THAN THE EQUIVALENT OF FOUR QUARTER BENDS (360 DEGREES TOTAL).
OEM
ITS CABINET
IF NUMBER OF BENDS EXCEEDS 360 DEGREES, THE CONTRACTOR SHALL
INSTALL ADDITIONAL JUNCTION BOXES, AS REQUIRED.
m
®�
JUNCTION BOX TYPE 1, 2, 8
8.
ILLUMINATION SHALL BE MAINTAINED DURING CONSTRUCTION IN
25—TA
25—TA VAULT
ACCORDANCE WITH SECTION 8---20.3(1)A OF .I HE SPEC IFICA �yIONS. THE
%CONTRACTOR
IS ALSO RESPONSIBLE FOR MAINTAINING 10' CLEARANCE
®- - —
CONDUIT
ZONE AROUND EXISTING AERIAL PRIMARY POWER LINES DURING THE
CONSTRUCTION. COORDINATE WORK WITH THE POWER COMPANY
WIRE NOTE
REPRESENTATIVE.
o
CONSTRUCTION NOTE
9.
FOR LOCATIONS OF PRIVATE LUMINAIRES TO BE REMOVED, SEE SITE 1
PREPARATION PLANS. GRIND DOWN EXISTING FOUNDATION TO 2, BELOW
PROPOSED GRADE AND CAP AND ABANDON EXISTING UNUSED CONDUIT.
SPLICE EXISTING WIRING IF NECESSARY TO MAINTAIN CONNECTIONS TO
EXISTING PRIVATE LUMINAIRES TO REMAIN. BACKFILL AND COMPACT ALL
VOIDS PER SPECIAL PROVISIONS.
/5 10 20 40 .!
SCALE IN FEET BID
DOCUMENTS
CITY OF RENTON
RAINIER AVENUE S (SR 167)
DRAWING No. 230
S G RADY WAY TO S 2N D ST
PROJECT NO. TED403430
753 9th Ave N 2502 Jefferson Ave
Public Works D e p a r t m e n t
FED AID NO. CM0167(04p)
Seattle, WA 98109 Tacoma, WA 98402
ILLUMINATION AND INTERCONNECT PLAN
(206) 286-1640 (253) 627-0720
APPROVES? FOR CONSTRUCTION
DATE; _ NOV 2'_,01 1_
www.kpg.com
BY:
/
DATE /lip ��r
STA 1 5+50 TO STA 20+00
�
SHEET NO. 230 _ OF _ 0
fy
,