HomeMy WebLinkAboutTRO4103430.93LEGEND
GENERAL NOTES
1. ALL WORK SHALL BE DONE WITH WSDOT STANDARD PLANS &
SPECIFICATIONS AND THE LATEST AMENDMENTS, APWA STANDARDS, THE
CITY DEVELOPMENTAL GUIDELINES AND THESE PLANS.
2. UTILITY LOCATION (DIAL -A -DIG) PRIOR TO CONSTRUCTION SHALL BE THE
RESPONS-AB" ITY OF TIDE CONTRACTOR. CONFLICTS SHALL BE BROUGHT
CDT J THE ATTENTION OF THE ENGINEER FOR RESOLUTION.
3. CONTRACTOR SHALL COORDINATE WITH POWER COMPANY REGARDING THE
"'
ELECTRICAL SERVICE CONNECTION. CONTRACTOR SHALL MEET WITH
CD
PUGET SOUND ENERGY REPRESENTATIVE SHERI CLARKE AT (425)
450W'L 101 PRIOR s INS I A► LATION OF METER BASE.
4. THE LOCATION: Or A-r_ FEATURES I.� B� INSTALLED BY THE CONTRACTOR
SHAD.. BE 'VERIFIED IN I~ IELD BY THE ENGINEER PRIOR TO INSTALLATION.
7D
5. ALL NEW JUNCTION BOXES INSTALLED IN SIDEWALKS SHALL HAVE SKID
o
RESISTANT LIDS. ALL JUNCTION BOXES SHALL HAVE LOCKING LIDS PER
COR STD PLAN #127.
Ln
6. CONDUIT LOCATIONS ARE SHOWN FOR REFERENCE ONLY. FINAL
Q0
LOCATIONS
SHALL BE DETERMINED BY THE CONTRACTOR AND APPROVED
0
BY THE ENGINEER IN THE FIELD.
0
0
7. NUMBER OF CONDUIT BENDS BETWEEN PULL POINTS SHALL NOT BE MORE
THAN THE EQUIVALENT OF FOUR QUARTER BENDS (360 DEGREES TOTAL).
IF NUMBER OF BENDS EXCEEDS 360 DEGREES, THE CONTRACTOR SHALL
INSTALL ADDITIONAL JUNCTION BOXES, AS REQUIRED.
8. ILLUMINATION SHALL BE MAINTAINED DURING CONSTRUCTION IN
U,
ACCORDANCE WITH SECTION 8-20.3(1)A OF THE SPECIFICATIONS. THE
CONTRACTOR IS ALSO RESPONSIBLE FOR MAINTAINING 10' CLEARANCE
ZONE AROUND EXISTING AERIAL PRIMARY POWER LINES DURING THE
CONSTRUCTION. COORDINATE WORK WITH THE POWER COMPANY
o
REPRESENTATIVE.
`D
i
9. FOR
LOCATIONS OF PRIVATE LUMINAIRES TO BE REMOVED, SEE SITE
o
PREPARATION PLANS. GRIND DOWN EXISTING FOUNDATION TO 2' BELOW
LLJ
PROPOSED GRADE AND CAP AND ABANDON EXISTING UNUSED CONDUIT.
i
SPLICE EXISTING WIRING IF NECESSARY TO MAINTAIN CONNECTIONS TO
EXISTING
PRIVATE LUMINAIRES REMAIN. BACKFILL AND COMPACT ALL
�
_TO
VOIDS PER SPECIAL PROVISIONS.
LLJ
/�1
J
1
ADDENDUM #2, REMOVED PRIVATE POLE REMOVAL NOTES
Cn
O
n_
U)
C
z
NUMBER
REVISION DESCRIPTION
LUMINAIRE SCHEDULE (ELECTRICAL SERVICE CABINET "S2" — SEE CIRCUIT AND PANEL SCHEDULES SHEET 238)
LUMINAIRE
#
STATION
OFFSET
LUMINAIRE TYPE
LUMINAIRE'';
ARM
MOUNTING
HEIGHT
�,, POLE
TYPE
CIRCUIT
#
� DECAL
#
COMMENTS
21
RAINIER AVE S,
STA
24+77
53.5'
LT
"DECORATIVE"
135W
LED
(M-11—FC)
240V
6
35'
40'
B
7738NL
SERVICE
#S2
22
RAINIER AVE S,
STA
24+84
53.5'
RT
"DECORATIVE"
135W
LED
(M-11—FC)
240V
6'
35'
40'
C
7735NL
SERVICE
#S2
23
RAINIER AVE S,
STA
26+08
53.3'
RT
"DECORATIVE"
135W
LED
(M-11—FC)
240V
6'
35'
40'
B
7737NL
SERVICE
#S2
_
24
RAINIER AVE S,
STA
26+33
54.3'
LT
"DECORATIVE"
135W
LED
(M-11—FC)
240V
6'
35'
40'
C
7740NL
SERVICE
#S2
25
RAINIER AVE S,
STA
27+66
52.0'
RT
"DECORATIVE"
135W
LED
(M-11—FC)
240V
6
L 35'
40'
C
7739NL
SERVICE
#S2
26
RAINIER AVE S,
STA
27+85
54.3'
LT
"DECORATIVE"
135W
LED
(M-11—FC)
240V
6'
35'
40'
B
7742NL
SERVICE
#S2
e 27
RAINIER AVE S,
STA
28+66
50.0'
RT'
"DECORATIVE"
135W
LED
(M-11—FC)
240V
6'
35'
40'
B
7741 NL
SERVICE
#S2
P29
SHARED
POLE
"DECORATIVE"
60W
LED
(S-111—FC)
240V
4'
14'
40'
D
7738NL
SERVICE
#S2
P30
SHARED
POLE
"DECORATIVE"
60W
LED
(S-111—FC)
240V
4'
14'
40'
D
7735NL
SERVICE
#S2
P31
RAINIER AVE S,
STA
25+53
53.5'
RT
"DECORATIVE"
60W
LED
(S-111—FC)
240V
4'
14'
18'
D
7743L
SERVICE
#S2
P32
RAINIER AVE S,
STA
25+66
53.5'
LT
"DECORATIVE"
60W
LED
(S-111—FC)
240V
4'
14'
18'
D
7744L
SERVICE
#S2
P33
SHARED
POLE
"DECORATIVE"
60W
LED
(S-111—FC)
240V
4'
14'
! 40'
D
7737NL
SERVICE
#S2
P34
SHARED
POLE
"DECORATIVE"
60W
LED
(S-111—FC)
240V
4'
14'
40'
D
7740NL
SERVICE
#S2
P35
RAINIER AVE S,
STA
26+86
53.0'
RT
"DECORATIVE"
60W
LED
(S-111—FC)
240V
! 4'
14
18
D
! 7745L
SERVICE
#S2
P36
RAINIER AVE S,
STA
27+12
54.5'
LT
"DECORATIVE"
60W
LED
(S-111--FC)
240V
4'
14'
18'
D
7746L
SERVICE
#S2
P37
SHARED
POLE
"DECORATIVE"
60W
LED
(S-111—FC)
240V
4'
14'
40'
D
7739NL
SERVICE
#S2
P38
SHARED
POLE
"DECORATIVE"
60W
LED
(S-111—FC)
240V
4'
14'
40'
D
7742NL
SERVICE
#S2
P39
RAINIER AVE S,
STA
28+27
51.5
RT
"DECORATIVE"
60W
LED
(S-111—FC)
240V
4'
14'
18'
D
j 7747L
SERVICE
#S2
P40
RAINIER AVE S,
STA
28+56
53.5'
LT
"DECORATIVE"
60W
LED
(S-111—FC)
240V
4'
14'
18'
D
7748L
SERVICE
#S2
P41
SHARED
POLE
"DECORATIVE"
60W
LED
(S-111—FC)
240V
4'
14'
40'
D
7741 NL
SERVICE
#S2
40
JJA
JF
12-16-11
11-14-11
F
0 • WAsy�S
�P O
�FSFOf6TER��v�
RL EN
SURVEYED: KPG
-
DRAWN BY: JM
DESIGN BY: JF
CHECK BY: JF
PROJ MGR: TN
FILE:0655DILL01.dwg
BY
APP.
DATE
0 5 10 20 40 60
SCALE IN FEET
FEHR
&, PEERS
TRANSPORTATION CONSULTANTS
1001 4th Avenue.
Walnut Creek CA - Orange Canty. CA
. Roseville. CA o Las Angeles Canty, CA
Suite 4120
° San Jose, CA ° San Diego, CA
Seattle. WA 98154
° San Francisco. CA o Salt Lake City. UT
(206) 576-4220
° Sacramento. CA o Reno,NV
- Seattle, V4'A - Denver, CO
1 011;11* ;Z!1� J-IM
753 9th Ave N 2502 Jefferson Ave
Seattle, WA 98109 Tacoma, WA 98402
(206) 286-1640 (253) 627-0720
www.kpg.com
EXISTING
DENOTES EX. 0
POLE DECAL
XXXX
_ o
S
11
s1
3430172
CONSTRUCTION NOTES
x z 1
NEW DESCRIPTION
SIGNAL POLE WITH MAST ARM
TYKE I OR PS POLE:
WIRE NOTES
EXISTING LUMINAIRE
DECORATIVE PEDESTRIAN LUMINAIRE
DECORATIVE ROADWAY LUMINAIRE
DECORATIVE PEDESTRIAN/ROADWAY LUMINAIRE
SIGNAL CONTROLLER CABINET
ELECTRICAL SERVICE CABINET
ITS CABINET
JUNCTION BOX TYPE 1, 2, 8
25-TA VAULT
CONDUIT
WIRE NOTE
CONSTRUCTION NOTE
®RACEWAY/
CONDUIT
SIZE
CONDUCTORS
COMMENTS
I
I
1
ff
2
�
2#8
I _r-
SEA
i SEE
_
N-0 ! 1 '
NOT ES
BELOW
BELOW
2
2ff �4#8'_---------.
3
2"
6#8
SEE
NOTES
BELOW
4
4"
SPARE
5
4"
1-96 SMFO
SEE
NOTES
BELOW
6
2"
SEE
NOTES
BELOW
7
EX.
SEE
NOTES
BELOW
8
4"
EX. 1-48 SMFO
RE-ROUTE
—
NOTES:
1. ALL CONDUIT CONTAINING CONDUCTORS SHALL HAVE MIN 1--#8
GROUND WIRE (UNLESS GROUND WIRE SITE IS SPECIFIED IN 7jlE WIRE
SCHEDULE OTHERWISE). SPARE CONDUIT SHALL CONTAIN BULL—LINILE
TAPE AND LABELED "CITY OF RENTON".
2. ALL SIGNAL AND LIGHTING CONDUIT SHALL BE RIGID PVC SCH 40,
EXCEPT UNDER ROADWAY USE RIGID PVC SCH 80. AI_L FIBER CONDUIT
AND SPARE 4" CONDUIT SHALT_ BE RIGID PVC 3uH ,SO WITH Fi EXIBL.E
FABRIC INNERDUCT INSTALLED PER SPE CI ICAI[11ONS.
Q CONSTRUCT LUMINAIRE POLE FOUNDATION PER ILLUMINATION DETAILS SHEET 239. FURNISH AND INSTALL DECORATIVE LUMINAIRE,
POLE, ARM, CONDUIT/WIRING ALL ASSOCIATED EQUIPMENT AND APPLY DECAL NUMBERING TO LUMINAIRE POLES. FOR ADDITIONAL
INSTALLATION DETAILS SEE ILLUMINATION SHEET 239, COR STANDARD DRAWINGS J007, J0083 J0092 J0131 J015 AND SPECIAL
PROVISIONS.
® REMOVE EXISTING LUMINAIRE POLE, LUMINAIRE, JUNCTION BOX, WIRING AND CAP AND ABANDON EXISTING UNUSED CONDUIT. GRIND
DOWN EXISTING FOUNDATION 2' BELOW PROPOSED GRADE. BACKFILL AND COMPACT ALL VOIDS PER SPECIAL PROVISIONS.
SALVAGE CITY OWNED POLE AND LUMINAIRE PER SPECIAL PROVISIONS.
® EXISTING LUMINAIRE TO REMAIN. MAINTAIN CIRCUIT CONTINUITY DURING CONSTRUCTION.
®rp
® SEE SIGNAL PLANS FOR CONSTRUCTION NOTES REGARDING INSTALLATION OF ADDITIONAL SIGNAL SYSTEM EQUIPMENT.
10 FOR EXISTING JUNCTION BOX REMOVAL/MODIFICATION CONSTRUCTION NOTES SEE SIGNAL PLANS.
13 SEE WIRE SCHEDULE ON SIGNAL PLANS FOR CONDUIT CONTAINING SIGNAL WIRING.
BID
INSTALL 1" GRS CONDUIT FROM JUNCTION BOX TO BUS SHELTER FOOTING. REFER TO METRO STANDARDS FOR CONSTRUCTION OF
14 TRANSIT PASSENGER FACILITIES AND DETAILS, SHEET 27 FOR CONDUIT STUB LOCATION. DOCUMENT.
;; RAINIER AVENUE S (SR 167) DRAWING No. 23 _
RCITY OF RENTON
•.0 S GRADY WAY TO S 2ND ST PROJECT NO. TED-403430
Public Works Department -
FI=LD AID NO. Clt/10167g048,
�
PPRnOD OR CONSTRUCTION�APPRO D OR CONSTRUCTION ILLUMINATION AND INTERCONNECT PLAN
BY: 4DATE: % STA 24+50 TO STA 29+00 SHEET NO. 232 OF 304