Loading...
HomeMy WebLinkAboutTRO4103430.96GENERAL NOTES 1. ALL WORK SHALL BE DONE WITH WSDOT STANDARD PLANS & SPECIFICATIONS AND THE LATEST AMENDMENTS, APWA STANDARDS, THE CITY DEVELOPMENTAL GUIDELINES AND THESE PLANS. 2. UTILITY LOCATION (DIAL -A -DIG) PRIOR TO CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. CONFLICTS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION, 3. CONTRACTOR SHALL COORDINATE WITH POWER COMPANY REGARDING THE ELECTRICAL SERVICE CONNECTION. CONTRACTOR SHALL MEET WITH PUGE T SO�JNf ENERGY REPRESENTATIVE SHERI CLARKE AT (425) 456-2701 PRIOR TO INSTALLATION OF METER BASE. 4. THE LOCATION OF ALL FEATURES TO BE INSTALLED BY THE CONTRACTOR SHALL BE VERIFIED IN FIELD BY THE ENGINEER PRIOR TO INSTALLATION. 5. ALL. NEW JUNCTION BOXES INSTALLED IN SIDEWALKS SHALL HAVE SKID RESISTANT LIDS. ALL JUNCTION BOXES SHALL HAVE LOCKING LIDS PER COR STD = PLAN 1 �7. 6. CONDUIT LOCATIONS ARE SHOWN FOR REFERENCE ONLY. FINAL LOCATIONS SHALL BE DETERMINED BY THE CONTRACTOR AND APPROVED BY THE ENGINEER IN THE FIELD. 7. NUMBER OF CONDUIT BENDS BETWEEN PULL POINTS SHALL NOT BE MORE THAN THE EQUIVALENT OF FOUR QUARTER BENDS (360 DEGREES TOTAL). IF NUMBER OF BENDS EXCEEDS 360 DEGREES, THE CONTRACTOR SHALL INSTALL ADDITIONAL JUNCTION BOXES, AS REQUIRED. 8. ILLUMINATION SHALL BE MAINTAINED DURING CONSTRUCTION IN ACCORDANCE WITH SECTION 8-20.3(1)A OF THE SPECIFICATIONS. THE CONTRACTOR IS ALSO RESPONSIBLE FOR MAINTAINING 10' CLEARANCE ZONE AROUND EXISTING AERIAL PRIMARY POWER LINES DURING THE CONSTRUCTION. COORDINATE WORK WITH THE POWER COMPANY REPRESENTATIVE. l'! CONSTRUCT LUMINAIRE POLE FOUNDATION PER ILLUMINATION DETAILS SHEET 239. FURNISH AND INSTALL DECORATIVE LUMINAIRE, POLE, ARM, CONDUIT/WIRING ALL ASSOCIATED EQUIPMENT AND APPLY DECAL NUMBERING TO LUMINAIRE POLES. FOR ADDITIONAL INSTALLATION DETAILS SEE ILLUMINATION SHEET 239, COR STANDARD DRAWINGS J007, J008, J009, J013, J015 AND SPECIAL PROVISIONS. REMOVE EXISTING LUMINAIRE POLE, LUMINAIRE, JUNCTION BOX, WIRING AND CAP AND ABANDON EXISTING UNUSED CONDUIT. GRIND DOWN EXISTING FOUNDATION 2' BELOW PROPOSED GRADE. BACKFILL AND COMPACT ALL VOIDS PER SPECIAL PROVISIONS. SALVAGE CITY O'NED POLE AND LUMINAIRE PER SPECIAL PROVISIONS. 3 CONSTRUCT FOUNDATION PER DETAILS ON SHEET 263 AND FURNISH AND INSTALL ELECTRICAL SERVICE CABINET PER COR STD DWGS J01 U AND J011 WITH BACK-TO-BACK BATTERY BACKUP SYSTEM PER SPECIAL PROVISIONS. FOR LOCATION AND PANEL SCHEDULE, SEE ILLUMINATION CIRCUIT DIAGRAM AND DETAILS SHEET 238. COORDINATE CONNECTION DETAILS TO THE POWER SOURCE WITH THE POWER COMPANY REPRESENTATIVE PRIOR TO INSTALLATION OF FOUNDATION. SEE SPECIAL PROVISIONS. Cr�j L!_IMINA.IRE TO BE PART OF A SIGNAL SYSTEM. APPLY DECAL NUMBERING TO POLE, FOR ADDITIONAL INSTALLATION DETAILS SEE SIGNAL PLANS. 0 EXISTING SIGNAL POLE MOUNTED LUMINAIRE. FOR REMOVAL NOTES SEE SIGNAL PLANS. 10 FOR EXISTING JUNCTION BOX REMOVAL/MODIFICATION CONSTRUCTION NOTES SEE SIGNAL PLANS.. 13 SEE WARE SCHEDULE ON SIGNAL PLANS FOR CONDUIT CONTAINING SIGNAL WIRING. 14 INSTALL 1" GRS CONDUIT FROM JUNCTION BOX TO BUS SHELTER FOOTING. REFER TO METRO STANDARDS FOR CONSTRUCTION OF TRANSIT PASSENGER FACILITIES AND DETAILS SHEET 7 R , E 2 F0 CONDUIT STUB LOCATION. 17 INSTALL NEW TYPE 8 TRAFFIC RATED JUNCTION BOX. LID SHALL BE LABELED "ITS". LUMINAIRE SCHEDULE (ELECTRICAL SERVICE CABINET "S4" - SEE CIRCUIT AND PANEL SCHEDULES SHEET 238) 6 0 5 10 20 40 60 SCALE IN FEET LUMINAIRE # STATION OFFSET LUMINAIRE TYPE LUMINAIRE ARM MOUNTING HEIGHT POLE TYPE CIRCUIT # DECAL # COMMENTS D1 ` * "DECORATIVE" DECORATIVE135W LED (M-111-FC) 240V W PHOTOCELL) / * * * A 7773N * SEE SIGNAL PLANS FOR INFORMATION NOT SHOWN D2 * * "DECORATIVE" 135W LED (M-111-FC) 240V * * - * A 7774N * SEE SIGNAL PLANS FOR INFORMATION NOT SHOWN D3 * t * „DECORATIVE" 135W LED(M-111-FC)240V * * } A 7776N SEE SIGNAL PLANS FOR INFORMATION NOT SHOWN D4 T * ! DECORATIVE" 135W LED (M-111-FC) 240V * * * A 7775N * SEE SIGNAL PLANS FOR INFORMATION NOT SHOWN I 4� RAINIER AVE S, STA 38+97 47.5 LT DECORATIVE 135W LED (M-II-FC) 240V 6 35 40 C 7778NL SERVICE #S4 44 RAINIER AVE S, STA 38+97 47.5' RT "DECORATIVE" 135W LED (M-II-FC) 240V 6' 35' 40 B 7777NL SERVICE #S4 45 RAINIER AVE S, STA 40+16 49.0' LT "DECORATIVE" 135W LED (M-11-FC) 240V 6' 35 40' B 7780NL . SERVICE #S4 46 RAINIER AVE S, STA 40+1fi 49.0 RT DECORATIVE" 135W LED (M II-FC) 240V 6' . 35' 40 C y 7779NL SERVICE #S4 P58 RAINIER AVE S, STA 38+47 47.5 LT DECORATIVE 60W LED (S-111-FC) 240V 4 14 18 D 7782L SERVICE #S4 P59 RAINIER AVE S, STA 38+47 47.5 RT DECORATIVE 60W LED (S-III-FC) 240V 4 14 18 D 7781E SERVICE #S4 P60 SHARED POLE DECORATIVE 60W LED(S-111-FC)240V 4 14' - 40' D 7778NL SERVICE #S4 P61 SHARED POLE_ "DECORATIVE" 60W LED (S-111-FC) 240V 4' 14' 40 D 7777NL SERVICE #S4 P62 _ RAINIER AVE S, - STA 39+44 48.0 LT "DECORATIVE" 60W LED (S-III-FC) 240V 4' 14' I8' D 7784L SERVICE #S4 Pfi3 RAINIER AVE S, S A 39+44 48.0 RT "DECORATIVE" 60W LED (S-111-FC) 240V 4' 14' 18' D 7783E SERVICE S4 P64 SHARED POLE ! "DECORATIVE" 60W LED (S-111-FC) 240V 4' f 14 40' D 7780NL SERVICE S4 _- - - - - -__- _ _------- -- P65 SHARED POLE "DECORATIVE" 60W LED (S-III-FC) 240V 4' 14' 40' D 7779NL SERVICE #S4 - WIRE NOTES # RACEWAY/ CONDUIT SIZE CONDUCTORS COMMENTS 1 2" 2#8 SEE NOTES BELOW 2 2" 4#8 SEE NOTES BELOW 3 2" 6#8 SEE NOTES BELOW 4 4" SPARE 5 4" 1-96 SMFO SEE NOTES BELOW 6 2" -------------- SEE NOTES BELOW 7 EX. SEE NOTES BELOW 8 4" EX. 1-48 SMFO RE-ROUTE NO TES: 1. ALL CONDUIT CONTAINING CONDUCTORS SHALL HAVE MIN 1-#8 GROUND WIRE (UNLESS GROUND WIRE SIZE IS SPECIFIED IN THE WIRE SCHEDULE OTHERWISE). SPARE CONDUIT SHALL CONTAIN BULL -LINE TAPE AND LABELED "CITY OF RENTON". 2. ALL SIGNAL AND LIGHTING CONDUIT SHALL BE RIGID PVC SCH 40, EXCEPT UNDER ROADWAY D Y USE RIGID PVC SCH 80. ALL FIBER CONDUIT AND SPARE 4" CONDUIT SHALL BE RIGID PVC SCH 80 WITH FLEXIBLE FABRIC INNERDUCT INSTALLED PER SPECIFICATIONS. LEGEND EXISTING NEW DESCRIPTION SIGNAL POLE WITH MAST ARM M01ES a. TYPE I OR PS POLE POLE DECAL # xx�c-- x —_... EXISTING LUMINAIRE Ci�_ DECORATIVE PEDESTRIAN LUMINAIRE DECORATIVE ROADWAY LUMINAIRE DECORATIVE PEDESTRIAN/ROADWAY LUMINAIRE SIGNAL CONTROLLER CABINET ELECTRICAL SERVICE CABINET Ire ITS CABINET X 10 El JUNCTION BOX TYPE 1, 2, 8 25-TA 25-TA VAULT L CONDUIT WIRE NOTE CONSTRUCTION NOTE T=3430175 BID DOCUMENTS ADDENDUM #2. REMOVED PRIVATE POLE REMOVAL NOTES JJA JF 12-16-1 i 1'4 _ 1 SURVEYED: KPG RAINIER AVENUE S (SR 67) DRAWING NO. 235 rq y DRAWN BY JM CITY OF R EN TON S GRADY WAY TO S 2ND ST PROJECT NO, TED403430 < _ DESIGN BY. JF__ FEHP, PEERS 753 9th Ave N 2502 Jefferson Ave CHECK BY: JF TRANSPORTATION CONSULTANTS Seale,WA98109 Tacoma, WA98402 ILLUMINATION AND INTERCONNECT PLAN FED AID NO, CM01 67(043) .. DATE : NOV 2011 �� ,(2(�i} 286- j)�7�o7O APPR FOR CONSTRUCTION a ©� Y �, PROJ MGR: TN ' 15 . w .k com �oNAI �N i BY: DATE: / /� STA 38+00 TO STA 42+00 SHEET No. 235 oI=� NUMBER REVISION DESCRIPTION BY APP. DATE G FILE: 0655DILL01.dwg ` `'`