HomeMy WebLinkAboutWTR2703430.1GENERAL WATER CONSTRUCTION NOTES
Ln
0
CD
N
N
0
a
n
LC)
L )
co
0
U
v
Of
Ln
LC)
0
i
z
0
I
z
LiJ
CL
U�
L1J
0
ry
CEMENT CONCRETE
PAVEMENT SECTION
PER TYPICAL
SECTIONS & DETAILS
CONCRETE am- HMA ROADWAY
AREAS 44-7 PAVEMENT AREAS
1 1' MIN FOR
TRENCH CROSSINGS
COMPACTED
SUBGRADE
HMA ROADWAY
SECTION PER TYPICAL
SECTIONS &DETAILS
0
D.I. WATER
PIPE WITH
POLYWRAP
SAWCUT EXISTING
PAVEMENT, APPLY TACK
COAT TO SIDES
V///
EXISTING PAVEMENT
MAY INCLUDE BURIED
CONCRETE ROADWAY
PANELS (TYP)
GRAVEL BACKFILL INCL. HAUL
FOR WATER
GRAVEL BACKFILL FOR PIPE
ZONE BEDDING, COMPACTED
TO 95% MAX DENSITY OR
CONTROLLED DENSITY FILL
AS INDICATED ON THE PLANS
NOTES
1. FINISHED GRADE SURFACES FOR NON ROADWAY AREAS NOT SHOWN. PROVIDE CURBS,
SIDEWALKS, DRIVEWAY AND PARKING AREA PAVEMENT, AND UNPAVED SURFACE
RESTORATION AS SHOWN ON THE PLANS.
2. THE MAXIMUM PAY LIMITS FOR TRENCH WIDTHS SHALL BE IN ACCORDANCE WITH WSDOT
STD SPECIFICATION 2-09.
3. TEMPORARY PAVEMENT MAY BE USED FOR PATCHING IN AREAS WHERE ADDITIONAL
ROADWAY OR TRENCH EXCAVATION IS ANTICIPATED, OR WHERE DRIVEWAY AND PEDESTRIAN
ACCESS MUST BE MAINTAINED.
4. EXCAVATION AND DISPOSAL_ OF CONTAMINATED SOILS SHALL BE IN ACCORDANCE WITH
SPECIFICATIONS, SEE SITE PREPARATION & TESC PLANS, SHEETS 69-79, FOR
APPROXIMATE CONTAMINATED SOIL LIMITS.
5. IF UNSUITABLE FOUNDATION IS ENCOUNTERED, SEE DETAIL, SHEET 26.
TYPICAL WATER TRENCH SECTION
N TS
WATER CONSTRUCTION NOTES
t FURNISH AND INSTALL CLASS 52 DUCTILE IRON WATER PIPE. SEE WATER LAYOUT TABLE
FOR STATION, OFFSET AND SIZE, THIS SHEET.
O FURNISH AND INSTALL LONG SOLID SLEEVE COUPLING AND PROVIDE CONNECTION TO
EXISTING WATER MAIN. SEE TYPICAL CONNECTION TO EXISTING MAIN DETAIL, SHT 142.
APPROXIMATE STA 11+15.8, 31.2' LT
1 - 12" COUPLING, MJxMJ
�3 FURNISH AND INSTALL TEE.
STA 11 +33.1, 40.5 R
1 - 12"x12"x12" TEE, FLxFLxFL
3 - 12" GATE VALVE, FLxMJ
1 - THRUST BLOCK
NUMBER REVISION DESCRIPTION I BY I APP. I DATE
\� ♦ dv
' l
e�
\\ �� HONDA
1 I
SEE CONNECTION 1 DETAIL, SHT 142
-1 I ±13 LF PIPE
\\ �.G II �%- - - - - - - - - - - - - - - - - ----- - - - - --
\ 1
1 \ II V
\ \ 1
°
26
w w ]- - - - - - - - - - - - - - - I�
\ 1 EXISTING 'I 23 - - 26 1 8 ±72 LF PIPE \ w
1 \ 12" D.I.
1
12 I I 26 \ c=ra
CD
10 +
\ i I 11 i \\ ICN
\\ \ CP
f6 LF PIPE
RAINIER AVE S \ \
\ w
1 \\ 1 I I I z
\ \ I I I I Ev-
\I �
1 \ I I 3 I ±66 LF PIPE 1
\ �--- --I--- - - i L----------- - --
\ D
_-
__________
ee`
e
� ee
e (P
7-4
Og FURNISH AND INSTALL 90 DEG BEND.
STA 11 +33.1, 31.2' LT
1 - 12" 90' BEND, FLxMJ 1 - 12" GATE VALVE, MJxFL
1 - THRUST BLOCK
10 FURNISH AND INSTALL FIRE HYDRANT ASSEMBLY PER CITY OF RENTON STANDARD PLAN
310.1.
11+22.0, 50.0' LT 11+52.7, 52.3' RT
22 ADJUST EXISTING WATER VALVE BOX TO GRADE.
23 ADJUST UTILITY MANHOLE (COVER) TO GRADE.
11-14-11 SURVEYED: KPG
KPHWAS ,Ia DRAWN BY: SOD/KH
DESIGN BY: SOD/KH 753 9th Avenue N 2502 Jefferson Avenue
CHECK BY: JLF Seattle, WA 98109 Tacoma, WA 98402
20320�wx (206) 286-1640 (253) 627-0720
GIST,ct � PROJ MGR: JF ,,,n.k com
SIGNAL �� p9'
FILE: 0655DWAT01.dwg
26 FURNISH AND INSTALL 12" CLASS 52 DUCTILE
IRON WATER PIPE.
28 FURNISH AND INSTALL CAP.
STA 11 +31.1, 55.9' RT
1 - 12" CAP, MJ
1 - THRUST BLOCK
BID
DOCUMENTS
1. EXISTING WATER MAINS, HYDRANTS, AND SERVICES SHALL REMAIN OPERATIONAL THROUGHOUT
THE COURSE OF CONSTRUCTION EXCEPT WHERE WATER BYPASS SYSTEMS ARE REQUIRED. FOR
INSTALLATION OF WATER BYPASS SYSTEMS SEE TEMPORARY WATER BYPASS PLANS, SHTS
160-163. ABANDONMENT AND/OR REMOVAL OF EXISTING MAINS SHALL TAKE PLACE ONLY
AFTER THE NEW MAIN OR WATER BYPASS SYSTEM HAS BEEN INSTALLED, TESTED, AND
APPROVED BY THE CITY OF RENTON.
2. MAIN SHUTDOWNS SHALL BE BY CITY MAINTENANCE STAFF ONLY. CUT -IN CONNECTIONS TO
EXISTING MAINS SHALL ALSO BE PERFORMED BY CITY STAFF. CONTRACTOR SHALL PROVIDE
TWO WEEK ADVANCED NOTICE TO CITY FOR SCHEDULE OF CONNECTIONS AND SHUTDOWNS.
3. EXISTING SERVICE LINES, METER SETTERS, AND METER BOXES ARE TO BE REPLACED AS PART
OF THIS PROJECT. EXISTING METERS ARE TO BE RESET WITHIN THE NEW SETTERS. COORDINATE
W/CITY OF RENTON.
4. DEFLECT JOINTS AS NECESSARY TO INSTALL WATER MAIN WITH MINIMUM COVER ALONG THE
APPROXIMATE LOCATION SHOWN. PIPE JOINTS NOT TO EXCEED 50 PERCENT OF THE MAXIMUM
JOINT DEFLECTION SPECIFIED BY THE PIPE MANUFACTURER.
5. ABANDONED EXISTING WATER MAINS SHALL BE CAPPED WITH (MJ) CAPS. PORTIONS OF THE
ABANDONED WATER MAIN MAY REQUIRE REMOVAL FOR THE CONSTRUCTION OF OTHER ROADWAY
IMPROVEMENTS.
6. EXISTING FIRE HYDRANTS SHALL BE REMOVED AND PROPERLY DISPOSED OF BY THE
CONTRACTOR AFTER INSTALLATION, TESTING, AND APPROVAL OF THE NEW HYDRANTS.
7. VERIFY LOCATION AND DEPTH OF EXISTING WATER MAINS AT ALL CONNECTION POINTS PRIOR
TO CONSTRUCTION. THE CONTRACTOR SHALL FIELD VERIFY THE OUTSIDE DIAMETER (O.D.) OF
ALL EXISTING CAST-IRON AND ASBESTOS -CEMENT PIPES, AND PROVIDE THE PROPER
LONG -BODY ADAPTERS AND TRANSITION COUPLINGS FOR THE FINAL CONNECTIONS BY CITY
FORCES. CONNECTIONS TO ALL DUCTILE IRON PIPES SHALL BE MADE WITH LONG SOLID SLEEVE
COUPLINGS (MJ).
8. ALL CONNECTIONS TO EXISTING WATER LINES SHALL BE MADE ONLY AFTER ALL THE NEW
WATER LINES AND APPURTENANCES HAVE SUCCESSFULLY PASSED ALL PRESSURE TESTS,
CLEANED WITH POLY -PIGS, DISINFECTED WITH CHLORINE SOLUTION, AND HAVE RECEIVED
SATISFACTORY BACTERIOLOGICAL TEST LAB REPORTS, AND ARE THOROUGHLY FLUSHED.
9. ELEVATIONS OF EXISTING CROSSING UTILITIES ARE PARTIALLY BASED ON RECORD DRAWING
INFORMATION. CONTRACTOR SHALL VERIFY LOCATIONS OF ALL UNDERGROUND EQUIPMENT
PRIOR TO CONSTRUCTION AND INFORM THE ENGINEER IF CONFLICT IS FOUND.
10. ALL WATER MAINS, FITTINGS, AND APPURTENANCES SHALL BE INSTALLED PER CITY OF RENTON
STANDARD DETAILS INCLUDED WITH PROJECT SPECIFICATIONS.
11. WATER PIPE AND FITTINGS INDICATED ON PLANS SHALL HAVE RESTRAINED JOINTS PER
SPECIFICATIONS. SEE WATER PLANS, SHTS 132-141 AND WATER PROFILES, SHTS 146-159 FOR
THESE LOCATIONS.
12. PROVIDE 10' HORIZONTAL SEPARATION FROM PARALLEL SEWER LINES. WATER SHALL CROSS
OVER EXISTING SEWER WITH 18" MINIMUM VERTICAL SEPARATION. WATER SHALL CROSS ALL
OTHER UTILITIES WITH 12" MINIMUM VERTICAL SEPARATION. CONCRETE ENCASEMENT MAY BE
NECESSARY WHERE THESE REQUIREMENTS CANNOT BE MET.
13. ALL WATER MAIN VERTICAL BENDS SHALL INCLUDE VERTICAL THRUST BLOCKING PER RENTON
PLAN 330.3. ALL WATER MAIN HORIZONTAL BENDS SHALL INCLUDE HORIZONTAL THRUST
BLOCKING PER RENTON PLAN 330.2.
0 5 10 20 40 60
SCALE IN FEET
WATER LAYOUT TABLE
STA
OFFSET LT
OFFSET RT
SIZE
11 +50
12+00
--
--
40.5'
40.5'
12"
- 12"
WATER LEGEND
- CITY OF RENTON
..11
Public Works Department
APPROVED FOR CONSTRUCTION
BY: r-.'_ DATE: /A4
ABANDON OR REMOVE EXISTING WATER MAIN
PROVIDE RESTRAINED JOINTS PER SPECIFICATIONS
W=343001
CORRESPONDING SHEETS
CATEGORY
SHEET
RIGHT OF WAY PLANS
7 i
EXISTING CONDITIONS _
SITE PREPARATION & TESC PLAN
_ 55
69
ALIGNMENT PLAN
81
ALIGNMENT PROFILE
93
DRAINAGE PLANS
104
DRAINAGE PROFILE
114
WATER PLAN--- -
- ---
_--
WATER PROFILE
146,156
JOINT UTILITY TRENCH PLAN -
164
JOINT UTILITY TRENCH PROFILES
180
PROPERTY RESTORATION PLANS
195
CHANNELIZATION & SIGNING PLAN
217
ILLUMINATION PLANS
228
IRRIGATION PLAN
282
LANDSCAPE PLAN
294
RAINIER AVENUE S (SR 167)
S GRADY WAY TO S 2ND ST
WATER PLAN
STA 10+00 TO STA 12+00
DRAWING NO.
132
PROJECT NO.
TED403430
FED AID NO.
-CM0167 048)
DATE:
NOV 2011
SHEET NO. 132 OF 304