Loading...
HomeMy WebLinkAboutWWP2703434.3LLJ Q Z U LLJ 0 ry CL 0 I I 90.00 I m x Z 0 30.00 X G�\, cp zO�/ G3 a ITO PROPOSED WSDOT RETAINING WALL SSMH #2 60" 0 DROP MANHOLE STA:12+56 RIM = 147.00 IE=141.50(1) IE = 122.00 (0) SAFETY CLIMB OR APPROVED EQUAL RETAINING SYSTEM SHALL BE PROVIDED FOR THE MANHOLE NORTH GRAPHIC SCALE 0 10 20 1 " = 20' o SSCO #1 RIM = 159.30 FOUND REBAR & I N 89°35'37" E 89 IE = 153.50 CAP LS #5524 ACCEPTED } 13.14' (C) � CLEARING LIMIT S VISITED: 9-15-013 SSMH #1 5/3 LF T PVC SS / S = 11.75% j ti / \ ��� FOUND REBAR & CAP LS #5524 1 ACCEPTED 48' 0 MANHOLE STA:12+03 / l tr� o J �� �`� t \1j VISITED:9-15-06 RIM = 123.76 � � � � � ^� ,. !4 � � � � � � '� \ -168- � 0 i IE=115.77 (1) N 35'3 " E _ IE = 115.60 (0) -�- 164 - -- \ ; 2 . w w -r ( i v 3o SHED 4 60 LF 6" PVC 74 S = 20.0°,a � - I \ ti 34.50 Sp O A� \ r:j'`: \ 1 30 LF 12" DIA STEEL CASING OA \ HOUSE 164 \i + ` AFILTER SO CLEARING LIMITS �, r (((rQ PROPOSED WSDOT L` RETAINING WALL g�� , 71, FABRIC I ENCE I �% PA' N 89°35'37" E I - - 200.09 (D) r �e IMPACT LINE � e e 30LF18"DIA e STEEL CASING I FILTER FABRIC FENCE I� CLEARING LIMITS ' CONTRACTOR SHALL FIELD VERIFY THE HORIZONTAL AND VERTICAL LOCATION OF THE 24" STORM DRAINGE MAIN. MINIMUM \ 10 SEPARATION BETWEEN SEWER AND STORM MAIN SHALL BE 1.0 FOOT. EX. 24" OUTFALL 1�\ IE = 91.52 to ci w w N '' V \ _-J� IT 12' WSDOT \1 �� TEMP. CONST.A-158 28`f 1 i Q EASEMENT CDI�o�� WALKWAY GARAGE o 166_ - 9- - - - . - £39 1.61'�C) V \ -_'- �_ '760 EX. CB -I \ \ \140� �150----1S RIM=127.44 �- `°� Ilp- N 8913137" E_ �.�6 11 �� _ \ \� '--_.B 'I -.�, I-�-----_ PAVED � \ l SEAL END CAP N Y+' rn 7"S j OS \ \ NW �EMP. , (TYP.) BOTH ENDS PAVED 00 BENCHMARK OF THE CASING �_ _ PK NAIL I \\ - `L w w w ` w w-�---w wl---�w w--"-_�_- -w j 1 EL 1.52.33�� Ir NW TEMP. �� w --- - -�- I I BENCHMARK 0g w -- w-� ww i ---� w w w-�-w HUB &TK �YYj EX. CB -I \ S Op i N 89°3�'37" E_ �a\ EL = 128.63 RIM = 128.61 81 85' e I I I PAVED IE = 124.73 (S) I I I I I iti - EX. CB -I RIM = 129.30-_-- IE = 124.70 (N)-1 IE = 126.21 (S) IE = 124.05 (W) ELECTRIC VAULT SS EXIST SSMH STA:10+05 e RIM =100.30 I E = 90.51 (1) IE = 90.41 (0) 1 e r e 90.00 e 1 � 1 F-riST��c Rokk MRK ENGINEEERING, PLLC 1954 Union Ave NE, Renton, WA 98059 z Ph: (206) 799-1379 fax: J W HIGH PRESSURE 20" OIL PIPELINE G) w 0 z STAMP IS NOT VALID UNLESS SIGNED AND DATED CITY OF RENTON STANDARD DETAILS: 1. FILTER FABRIC FENCE PER DETAIL B066 2. SANITARY SEWER MANHOLES PER DETAIL 13071 3. INSIDE DROP CONNECTION TO SSMH #3 PER DIETIAL B075.1 4. PIPE BEDDING FOR SANITARY SEWER PER DETAIL B077 5. TYPICAL TRANSVERSE PATCH FOR FLEXIBLE PAVEMENT PER DETAIL H032.1 NOTE: AFTER THE INSTALLATION OF THE SEWER MAIN, THE CONTRACTOR SHALL RESTORE THE BENSON ROAD S. PER THE CITY OF RENTON TRENCH RESTORATION AND OVERLAY REQUIREMENTS. 1 I REVISION PER CITY OF RENTON COMMENTS 001 REVISION 5 343403 RAF 02-06-08 SURVEYED: SCALE: MRK ENGINEERING DESIGNED: "=20' RAFIQUE DRAWN: RAFIQUE ONE INCH CHECKED: AT FULL SCALE Mazen Haidar IF NOT ONE INCH BY DATE 1 APPR APPROVED: SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM � RECOMMENDED FOR APPROVAL .j BY: B Y: - CITY OF RENTON Planning/Building/Public Works Dept. NWI/49S20,T23N, ROSE GENERAL UTILITY NOTES 1. THE CONTRACTOR SHALL COORDINATE HIS CONSTRUCTION ACTIVITIES WITH THE PERTINENT UTILITY COMPANIES TO ENSURE WATER METERS, TELEPHONE VAULTS, ETC. ARE BROUGHT TO GRADE PRIOR TO CONSTRUCTION OF CURB AND SIDEWALK. 2. THE CONTRACTOR WILL BE FULLY RESPONSIBLE FOR THE LOCATION AND PROTECTION OF ALL EXISTING UTILITIES. THE UTILITIES SHOWN ON THE PLANS ARE APPROXIMATE AND WILL NEED FIELD VERIFICATION FOR EXACT ALIGNMENT AND DEPTH. THERE MAY BE EXISTING UTILITIES NOT SHOWN ON THE PLANS. CONTRACTOR SHALL CONTACT ONE CALL LOCATING CENTER, 1-800-424-5555, PRIOR TO CONSTRUCTION. 3. ALL EXCAVATION METHODS AND SHORING TECHNIQUES SHALL BE IN ACCORDANCE TO WAC 296 TRENCH EXCAVATION SAFETY SYSTEMS. 4. ANY DEVIATIONS REGARDING THE WATER AND SEWER IMPROVEMENTS SHALL BE SUBMITTED TO THE CITY OF RENTON UTILITY DIVISION ENGINEER FOR APPROVAL PRIOR TO IMPLEMENTATION IN THE FIELD. 5. ALL WORK AND MATERIALS SHALL CONFORM TO THE STANDARD SPECIFICATION AND DETAILS OF THE CITY OF RENTON. WATER AND SEWER SPECIFICATIONS AND DETAILS SHALL BE THE SPECIFICATIONS AND DETAILS IN EFFECT ON THE DATE OF THE APPROVAL OF THESE CONSTRUCTION DRAWINGS. 6. NO WORK SHALL COMMENCE PRIOR TO A PRE -CONSTRUCTION CONFERENCE AT THE CITY OF RENTON. 7. AT ALL TIMES DURING CONSTRUCTION, THE APPROVED CONSTRUCTION DRAWINGS AND THE CITY OF RENTON STANDARD SPECIFICATION AND DESIGN DETAILS SHALL BE ON -SITE. 8. THE OWNER'S REPRESENTATIVE SHALL BE NOTIFIED IMMEDIATELY IF ANY UNIDENTIFIED OBJECTS AFFECTING CONSTRUCTION ARE ENCOUNTERED. DECIDUOUS TREE CONIFEROUS TREE POWER POLE GUY ANCHOR ® MAIL BOX im WATER METER WATER VALVE Ion' SLAB ON GRADE EXISTING CATCH BASIN EXISTING RIGHT OF WAY (R.O.W.) BP BURIED POWER LqAu"1.rP LOCATION OF EXISTING UTILITIES SHOWN IS APPROXIMATE AND MAY NOT BE ACCURATE OR ALL INCLUSIVE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO POTHOLE AS REQUIRED AND FIELD VERIFY LOCATION OF UTILITIES PRIOR TO PROCEEDING WITH CONSTRUCTION. CALL 2 DAYS BEFORE YOU DIG 1-800-424-5555 CITY FILE NO. CHECKED FOR COMPLIANCE TO CITY STANDARDS DATE: DATE: DATE: DATE: SEWER LINE EXTENTION PROJECT 02-05-08 TERESA TRAN PROPERTY FIELDBOOK: 1240 BENSON ROAD S. PAGE: DRAWING N0: RENTON, WA 98055 PROPOSED SEWER PLAN SHEET: 3 OF: 4 (V') -S4W� IAHNNNNAA