Loading...
HomeMy WebLinkAboutTED4003435.1LO C'7 T I O n J ��� w < W J lL SINGLE FAMILY RESIDENCE APN 106150-0860 w 0 SINGLE FAMILY LLJ RESIDENCE APN 092305-9011 0 0 0 J 0 PAR SINGLE FAMILY RESIDENCE APN 092305-9250 w w 0 0 o z w 0 SINGLE FAMILY RESIDENCE APN 297230-0060 AVOID CUTTING UNDERGROUND UTILITY ONES. IT'S COSTLY. Call before you Dig 1-800-424-5555 UNDERGROUND SERVICE (USA) 6' SOLID WOOD. FENCE 28" FIR 2' -4' HIGH ROCKERY MAPLE 30" FIR CT4 FILTER FABRIC FENCE SWALE IE=424.0 CLEARING LIMITS SINGLE FAMILY RESIDENCE APN 106150-0740 6' SOLID WOOD FENCE Nd8 20" FIR A PORTION OF THE NE 1/4 SECTION 9, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M. KING COUNTY, RENTON, WA. 4.25';W /425.26' SINGLE FAMILY RESIDENCE APN 106150-0730 SINGLE FAMILY RESIDENCE APN 106150-0720 6' SOLID, WOOD FENCF l 2' 4" HIGH ROCKiRY 24" FIR I / 1 24" FIR Dc O BUILDING / EX. LT / FIN FLR. 422.50 / / POLE I i / o / 80 LF INTERCEPTOR I SWALE ® 2.5% I 6"0 CPEP CULVERT O I SWALE IE= 44A t22.0 S88° 48' 04.26"E 405.25' ^� C-3 4 0 117 / Ile(DBASIN / 422 TEMPORARY CATCH / INSERT A- tK / V / 1 SINGLE FAMILY RESIDENCE APN 106150-0710 3 4" CEDAR 12" DECIDUOUS 4" CHERRY BUILDING FIN FLR. 420.00 SEDIMENT RISER 5 C-4 CLEARING LIMITS s 2" �WATE O / C-4 97 LF TEMPORARY / FILTER FABRIC FENCE 2 ® / INTERCEPTOR SWALE \ / C- PROPOSED SEDIMENT \ \ / TRAP LOCATION °O TESC CB - TYPE 1 c1 / PROVIDE RIPRAP RIM=421 i CLEARING LIMITS / \ \\ N 00 IE=417.7 1 SWALE IE=424.0 ) : O 1 CONSTRUCTION ENTRANCE / 6 4 C E RING LIMITS / 4 / 190 LF 8" CPEP ® 1.0% MINI C-4 FILTER FABRIC FENCE / o ' EX. LT 4 / o / CHERR� / EX. LT / / EX. LT / POLE / POLE / 2' HIGH WALL POLE 2' HIGH WALL 2' HIGH WALL R.R. TIES R. TIES R.R. TIES Q o 0 0 0 o C ERRY— —422 -- ---- -423 --422_____-----421- -423— — — — — R-Y422— — C ERR ----- --424-------------� 6' soup WOOD FENCE 88'48 4.26E 405.2 SINGLE FAMILY RESIDENCE -APN 297230-005 3 CHAINLINK FENCE 6' SOLID WOOD FENCE SINGLE FAMILY RESIDENCE - APN 297230-0030 6' SOLID WOOD FENCE SINGLE FAMILY RESIDENCE - APN 297230-0040 SINGLE FAMILY RESIDENCE - APN 297230-0020 6' SOLID WOOD FENCE 2 SINGLE FAMILY RESIDENCE - APN 29723 0010 FIR 3.•— EL. 422.0 EL. 421.0 EL. 420.0 EL. 419.5 BOTTOM EL. 419.0 NOTE: EXISTING UTILITY LOCATIONS SHOWN HEREON ARE APPROXIMATE ONLY. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE EXACT VERTICAL AND HORIZONTAL LOCATION OF ALL EXISTING UNDER GROUND UTILITIES PRIOR TO COMMENCING CONSTRUCTION. NO REPRESENTATION IS MADE THAT ALL EXISTING UTILITIES ARE SHOWN HEREON. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR UTILITIES NOT SHOWN OR UTILITIES NOT SHOWN IN THEIR PROPER LOCATION. CALL BEFORE YOU DIG: 1-800-424-5555 EXISTING GROUND SURFACE AREA SHOWN = 1127 S.F. REQ. AREA 1110 S.F. —— SEDIMENT TRAP SECTION SCALE: 1 " = 5' CITY O RENTON Approved by: Date: Approved by: Date: Approved by: Date: Approved by: Date: 50.0' -FILTER FABRIC FENCE - 0.5' SETTLING ZONE -0.5' DEAD STORAGE — — 1' FREE BOARD EL. 422.Of PAR w Z H w IZ 0 Of o 0 N I I 0 I I + I 1 I SINGLE FAMILY 1 I I I RESIDENCE o o I T I I i EX. F.H. I I I I I EX_ 10"W i i l i i i NE 10TH ST. l�Jl I I I i I I I I I I I I I I I I I I I I I 1 1 I 4 TEMPORARY CATCH C-4 BASIN INSERT � M N I EXIST. SSMH #274---// STA. 1 +46.13, 22.43' LT RIM=416.Ot IE=408.Of '3 15C) 5 MYLARS 02/11/081 SURVEYED: SCALE: TRIAD ASSOCIATES `�" ""`D's� 4 WQ FACILITY REVISION 01/30/08 SHOWN HORIZONTAL NAD isea/issi DESIGNED: 3 CITY OF RENTON COMMENTS 01/23/08 JAW 2 CITY OF RENTON COMMENTS 11/27/07 DRAwN. HR 1 CITY OF RENTON COMMENTS CHECKED: ONE INCH DATUM JAW AT Full SCALE IF NOT ONE INCH N 0. REVISION BY DATE AP P R APPROVED SCALE ACCORDINGLY CHER I I I I I I I I 1 I I I I I I I I I 1 I I I I I I I 1 � o N N j 1 EM", 1 • SINGLE FAMILY KEY NOTES RESIDENCE O SEE ARCHITECTURAL PLANS FOR STRUCTURES TO BE REMOVED OPROTECT EXISTING FENCE TREES OUTSIDE OF CLEARING LIMITS SHALL BE PROTECTED ® PROTECT EXISTING ELECTRICAL UTILITIES O PROTECT EXISTING WATER UTILITY © PROTECT EXISTING SEWER STUB SINGLE FAMILY RESIDENCE O DEMOLISH AND REMOVE EXISTING SEWER CLEANOUT ® DEMOLISH AND REMOVE EXISTING 6" SEWER GENERAL NOTES 1. POND DIVIDER SHALL BE AT LEAST ONE-HALF THE HEIGHT OF THE RISER AND A MINIMUM OF ONE FOOT BELOW THE TOP OF THE RISER. 2. ITEMS IDENTIFIED MAY NOT COMPRISE ALL STRUCTURES THAT NEED TO BE DEMOLISHED. WHEN THE SCOPE OF CONSTRUCTION REPRESENTED BY THESE PLANS REQUIRES ADDITIONAL DEMOLITION, CONTRACTOR SHALL UNDERTAKE SUCH DEMOLITION AFTER COORDINATING WITH THE OWNER AT HIS OWN COST. 3. THE SOILS ARE SOIL TYPE C AND THE CONTRACTOR SHALL MAINTAIN AND MODIFY EROSION CONTROL BEST MANAGEMENT PRACTICES AS REQUIRED THROUGHOUT THE ENTIRE CONSTRUCTION PROJECT. 4. A CERTIFIED PROFESSIONAL IN EROSION AND SEDIMENT CONTROL, JERRY WALDRON AT BASELINE ENGINEERING, 253-565-4491, WILL BE ON -CALL. WHEN THE GENERAL CONTRACTOR IS ESTABLISHED ON THE CONSTRUCTION SITE HE WILL TAKE OVER AS THE CERTIFIED EROSION AND SEDIMENT CONTROL LEAD. 5. DISTURBED AREA = 1.50 ACRES LEGEND OTEMPORARY CATCH BASIN INSERT CLEARING LIMITS (GENERAL ONLY -TREE PROTECTION MEASURES TO BE VERIFIED ON SITE) �•• ••• 0 INTERCEPTOR SWALE A• WA� FILTER FABRIC of WAf�� t�JO 422 EXISTING GRADE CONTOURS 36958 O �� TEMPORARY CONSTRUCTION ENTRAN E CISTER�' SSIONAL�mff ECG EXPIRES 8-10- DATE: CITY OF RENTON BIBLE CHURCH 02/11/08 973 UNION AVE FlELDBOOK: RENTON PAGE. DRAWING NO: Planning/Building/Public Works Dept. TEMPORARY EROSION C-3 AND SEDIMENT CONTROL PLAN SHEET-OF: 14