HomeMy WebLinkAboutWWP2703442.1NE 1 /4 OF SECTION 10, TOWNSHIP 23N, RANGE 5E, W.M. Ir 6"0 PVC SIDE SEWER 466 1.00% SLOPE -� 6"0 PVC SIDE SEWER, 12 1.00% SLOPE 'F=466.00 6 STUB EL. 462.50 CID i6 1 2 FF=469.00 FF=468.00 STUB EL. 461.05 STUB EL. 461.02 CLEANOUT (TYP.) I � I 464 _--_-_6"0 ' R 462 - 1.00X SLOPE 454 6"0 PVC SIDE SEWER, . ---- 460 f 13 1.00% SLOPE 452 450 FF=465.00 (MIN.) 14 15 STUB EL. 46139 FF=464.00 (MIN.) STUB EL. 460.46 FF=46 0 F (UPPER) STUB EL. 6 .46. FF=464.00 (UPPER) STUB4EL 72) FF=464.00 (UPPER) 1 STUB EL. 460:5g ., INTERNAL GRINDER REQ D FOR LOWER FLOOR STUB EL 461.18 .` , INTERNAL GRINDER REQ D I I 466 I TERNAL GRINDER REQ'D FOR LOWER FLOOR FOR LOWER FLOOR Q 10 I I 6" CLEARANCE I_ I 456 I MIN. (TYP.) 11 I I � 462 458 454 ( 6"0 PVC DINT SIDE SEWER, 460, 2.00% SLO E FROM MAIN 0- I3 CLEANOUT, 1.00 FROM CL OUT 462 468 - 5 6 TO LOT FF=469.00 I FF= 468.50 STUB EL. 460.43 FF=468.00 - 7 -- $-- 464 P STUB EL. 460.41 FF=467.50 t- 466 I STUB EL. 460.00 FF=467;00 STUB EL. 459.96 FF=465.00 v STUB EL. 459.40 STUB EL. 459.37 I PROPOSED FIRE HYD ANT I I 6" 0 P C SIDE SEWER, I 1 • ° I N ---------� 2.00% SLOP (TYP. UNLESS - I OTH RWISE NOTED) • I � � I 4 - - ♦16" CLEARANCE - - - - J { . _ .. B T STORM. EXISTING FIRE HYDRANT 1 EXISTIN3 SEWER MAIN; PROJECT S-3088 I 1 VERTICAL DATUM: NAVD 88 PER CITY OF RENTON VERTICAL CONTROL ALL SEWER INFORMATION IS PER FIELD SURVEY BASED ON ABOVE DATUM. EXISTING SIDE SEWER NOTE: EXISTING SIDE SEWERS FOR THE EXISTING RESIDENCES ARE TO BE FIELD LOCATED, CUT AND CAPPED PRIOR TO THE START OF CONSTRUCTION. I1 Call 2 Working Days Before You Dig 1-800-424-5555 Utilities Underground Location Center 0D,MT,ND,0R,WA) SANITARY SIDE SEWER GENERAL NOTES: 1. PRIOR TO INSTALLATION OF A SANITARY SEWER CONNECTION, A SIDE -SEWER PERMIT MUST BE PURCHASED FROM THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. 2. TYPES OF PIPE AND FITTINGS THAT CAN BE USED FOR SANITARY SEWERS SHALL BE APPROVED BY THE DEPARTMENT OF PUBLIC WORKS. RUBBER OR NEOPRENE GASKETS AS SPECIFIED BY THE MANUFACTURER, SHALL BE USED ON JOINTS. 3. A MINIMUM GRADE OF 2% (1/4" PER FOOT) MUST BE MAINTAINED WITH 4" PIPE. IN THE EVENT A 2% GRADE CANNOT BE MAINTAINED. THE OWNER MUST GRANT A GRADE RELEASE TO THE CITY AND THEN CAN INSTALL 6" PIPE AT A GRADE OF 1%. 4, FOR INSPECTION OF SIDE SEWER, CALL 24 HOURS IN ADVANCE, 277-5570. SITE MUST BE READY FOR INSPECTION AND REPRESENTATIVE ON SITE WHEN INSPECTOR ARRIVES AT APPOINTED TIME. SIDE SEWER AND STUB SHALL BE TESTED PER CITY SPECIFICATIONS. MAKE THE CONNECTION AT THE HOUSE. DO NOT BACKFILL THE DITCH UNTIL APPROVAL IS GIVEN BY THE INSPECTOR. FINAL APPROVAL WILL BE GRANTED AFTER THE EXISTING SEPTIC TANK HAS BEEN PUMPED OUT AND FILLED WITH SAND. 5. INSTALL SIDE SEWER WITH 2' MINIMUM COVER. 18" COVER IS ALLOWED AT THE HOUSE IF OUTLET IS SHALLOW. 6. IF SIDE SEWER STUB IS NOT AVAILABLE. THE OWNER SHALL BE RESPONSIBLE FOR ITS INSTALLATION. THE SIDE SEWER SHALL BE A MINIMUM OF 6" IN SIZE, IF TEE IS NOT AVAILABLE, THE MAIN SEWER LINE MUST BE TAPPED THRU A CAST IRON SADDLE. ALL WORK WITHIN STREET RIGHT-OF-WAY SHALL BE DONE BY A LICENSED AND BONDED CONTRACTOR. 7. ALL WORK SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THE WASHINGTON INDUSTRIAL SAFETY AND HEALTH ACT. (WISHA) 8. ALL TRENCH RESTORATION FOR SIDE SEWERS IN THE PUBLIC RIGHT-OF-WAY SHALL CONFORM TO THE MOST CURRENT TRENCH RESTORATION REQUIREMENTS AS SHOWN ON DWG. #HR-23. 9. ALL BUILDING SEWER AND SIDE SEWERS SHALL HAVE BEDDING IN ACCORDANCE WITH DRAWING BW18C OR BR09 AS APPLICABLE. 10. THERE SHALL BE A MINIMUM 10 FOOT HORIZONTAL SEPARATION BETWEEN SANITARY SIDE SEWERS AND WATER SERVICES AND A MINIMUM 5 FOOT HORIZONTAL SEPARATION BETWEEN SANITARY SIDE SEWERS AND ALL OTHER UTILITIES. I PROPERTY LINE z IE- o FUTURE 6" BUILDING SEWER PIPE DING SEWER �2'x Z 4" STUD MARKING POST PAINTED TEE WITH 6" SIDE OUTLET -' 6"X6"X6" WYE WHITE WITH THE WORD "SEWER" STENCILED SURFACE CLEANOUT WITH IN 3" HIGH BLACK LETTERS AND 6 WIRE w CAST IRON RIIJG & COVER k If (EAST JORDAN IRON WORKS WRAPPED AROUND THE STUD AND THE 2976 OR APPROVED EQUAL, EXTENDED TO THE TOP OF STUD a SPECIFY "SEVIER" ON LID, SEE STD PLAN 4031 FOR 6" SIDE SEWER AIJD BUILDING SEWER INSTALLATION) ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNECTIDNS TO MAIIJ LINES ARE AS FOLLOWS: A VITRIFIED CLAY MAIN - CUT IIJ A NEW TEE USING FLEXIBLE '. COUPLINGS (FERNCO OR APPROVED EQUAL) B CONCRETE MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) C. PVC MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) OR CUT IN A NEW TEE USIIJG RIGID COUPLINGS D. DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) E MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE'i AT MANUFACTURED KNOCK -OUTS OR THE STRUCTURE SHALL BE CORE -DRILLED 60" ALLOWABLE MAX / FOR CAST IRON PIPE OR DUCTILE IRON PIPE Z�OJj 1: 3: 5 mix o-5 G�6NO CONCRETE BLOCKING SP 15 /MPS S� 0L0 GO 27 MIN SLOPE HORIZONTAL 6" SIDE OUTLET TEE i SEWER 6" MIN MAIIJ SEWER MAIN CONCRETE BLOCKING ANGLE TYPICAL SIDE SEWER ELEVATION OF TEE AT MAIN OVER 25 ELEVATION NOTE: UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2.5' COVER AT PROPERTY LINE OR 3-5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER STANDARD SIDE SEWER SM. PLAN - 406.1 PUBLIC WORKS DEPARTMENT INSTALLATION �F lVTp (SIEUVER MAIN TO PROPERTY LONE) SEPTEMBER 2011 A J �� pF WASg ��df D.R. STRONG 1 CITY COMMENTS DATED OCT. 6. 2011 11 CONSULTING ENGINEERS 2 BAYFILTER REVISION 10604 NE 38th PLACE, SUITE 101 3 CITY COMMENTS DATED NOV. 15, 2011, MYL.AR KIRKLAND, WA 98033 45232 425.827.3063 OFFICE �ECISTER�1C5~ 800.962.1402 TOLL FREE ION 11 ��'l` 425.827.2423 FAX NO, REVISION MAJ 10.15.11 LRJ I SURVEYED: SJS MAJ 11.22.11 LRJ DESIGNED: MAJ MAJ 01.04.12 LRJ DRAWN: CWA CHECKED: MAJ I_y DATE AP P R APPROVEL Uw SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY 7� O ., RECESSED C) LIFT POCKET z iJ 5B' - 11 N C SOCKET HD 2" A C. SCREW 1 Ya" LONG (BRONZE OR SS) CD ® z f �d )z" x 2" RAISED PADS C O y 6" CONCRETE - CLASS 3000 SAND OR EXPANDABLE FOAM _® 12 Y,.. _ 4„ _ WATER TIGHT PLUG I 2 I 5/8 1 Y.' 12 Y," 14" CAST IRON RING AND COVER 45- (1 /8) BEND B., � aP �G �P .�o J� �O FP PIPE MATERIAL AS SPECIFIED C? BY THE ENGINEER _- 45' (1/8) BEND NOTES: 8" AND 6" CLEA14OUTS OIJ SEWER MAINS SHALL BE EAST JORDAN IRON WORKS, INC NO 3698 OR EQUAL CLEAN OUT SHALL BE A WATER TIGHT ASSEMBLY 2 IN UNIMPROVED AREAS, POUR A 1'-0" THICK, 2'-0" SQUARE CONCRETE. CLASS 3000, PAD AROUND THE RING AND COVER PUBLIC WORKS 8 OR 6 9h',gCM r:1 (EAH-OUT STD. PLAN - 403.1 DEPARTMENT FCC 3AN9 =1R MAINS I SEPTEMBER 2011 VERTICAL: NAVE, 1988 HORIZONTAL: NAD 1983/1991 DATM - CITY OF RENTON Planning/Building/Public Works Dept. 5-344201 CHECKED FOR COMPLIANCE TO CITY STANDARDS Date GRAPHIC SCALE Q 15' 30, 60' I-1 INCH = 30 FT, BROOKEFIELD NORTH SANITARY SEINER PLAN 09-06-11 FIELDBOOK: PAGE: C11 11 � . f (24U 1