Loading...
HomeMy WebLinkAboutWTR2703443.10 Y 0 m Z Q- w 1"=20' 0 10 20 40 I UTILITIES LEGEND: a---------------------- 4 w Q ti X 0 0 0 CL o x 0 n w cap z o t w 0 w > 0 Q a = 2 2 2 Q - 10 ao 00 00 O O O O uj W O Pj Q �I m EXISTING WATERMAIN EXISTING WATER BLOW OFF EXISTING FIRE HYDRANT EXISTING WATER VALVE EXISTING WATER METER PROPOSED WATER SERVICE LINE PROPOSED SANITARY SEWER LINE PROPOSED SANITARY SEWER CLEANOUT EXISTING SANITARY SEWER EXISTING SANITARY SEWER CLEANOUT EXISTING UNDERGROUND POWER EXISTING UNDERGROUND TELEPHONE EXISTING UNDERGROUND GAS LINE WATER AND SEWER SERVICE PLAN McDONALUS AT RAINIER AVE. S. RENTON, WA t A f fs•�. // I � � I _ /1f' I�V/�I IYI IL L1✓ I'll#VIA U ISTIIG 6" SI E SEW R �- ✓ / -- �' DETAIL &' SHEET' - .� al 18'LF 6"'PV C SSQO 4 4�? SDR-35 0 217% 0 3 RIM=37.12 RIM=37A 5 -ti o �$ ' Ile 71 LF 6 p,I.P, (FARE LINE t7 LY} E=34.01 lE=34.11 ; , .q 1 i 01 . ♦ ' ;z - a a a a p 70 , }t ° ° 18 LF 6" PVC c N ° SDR-35 ® 2.72% ` a I �I SSCO 2 ,,SSCO BLACK WATER ONLY 1 ';, �,;=, RIM=37.95 \'' ao IE=34.50_, GRAY WATER ONLY _- \ ° « _ ;: FB RIM=37. 5 3 4_�` I � 1 - \\,\' ,�\\ ♦ ..... `... - a � J - ,,,._.._ L/ III _ � - a ^ - - ° •. - i IL all T BY POT HOLING THE z .� v i ��� �.vl�r�iv i Iw i �•3 Z CAUTIONQ. '. Q THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH ♦. I! w >_ w v OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NO fn .Lu J 0 0_; a UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. a THIS SHALL INCLUDE CALLING UTILITY LOCATE 0 1-800-424-5555 AND THEN POT HOLING N Q' ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY o c VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE m w Ix a PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORMATION AND ARE SUBJECT TO VARIATION. - - IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT BARGHAUSEN C; CONSULTING ENGINEERS, INC. TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH I� tV I z CONSTRUCTION. W-3yN301 RECOMMENDED FOR APPROVAL By: Date By: 1% �' Date: By: r Date BY: � I Deus M alIIV Date GREASE INTERCEPTOR + SAND OIL INSTALLATION REQUIREMENTS 1. ALL INTERCEPTORS MUST BE A MINIMUM OF 2000 GALLON CAPACITY AND OF A DESIGN AS SPECIFIED BELOW. INTERCEPTOR DESIGN SHALL ADHERE AND BE CONSISTENT TO THE MOST RECENT APPROVED "UNIFORM PLUMBING CODE". 2. THE INLET "T" MUST BE PLUMBED 1-FOOT BELOW THE WATER LEVEL IN THE INTERCEPTOR. 3. THE OUTLET -T" MUST HAVE THE VERTICAL PIPE AT LEAST 6" IN DIAMETER AND THE HORIZONTAL AT LEAST 4" IN DIAMETER. IT MUST BE PLUMBED HALF WAY BETWEEN THE WATER LEVEL AND THE BOTTOM OF THE TANK. 4. ALL KITCHEN SINKS AND FLOOR DRAINS MUST BE PLUMBED THROUGH THE INTERCEPTOR. 5. DO NOT PLUMB DISHWASHERS THROUGH THE INTERCEPTOR. 6. DO NOT PLUMB ANY "BLACK WATER" THROUGH THE INTERCEPTOR. 7. IT IS RECOMMENDED THAT YOU DO NOT INSTALL OR USE GARBAGE DISPOSALS. THEY FILL THE INTERCEPTOR WITH SOLID WHICH RESULT IN MORE FREQUENT CLEANING, WHICH CAN BE COSTLY. 1. CONCRETE: 28 DAY COMPRESSIVE STRENGTH f c = 4500 psl 2. REBAR: ASTM A-615 GRADE 60 3. MESH: ASTM A-185 GRADE 65 4. DESIGN: ACI-318-83 BUILDING CODE ASTM C-857 "MINIMUM STRUCTURAL DESIGN LOADING FOR UNDERGROUND PRECAST CONCRETE UTILITY STRUCTURES" 5. LOADS: H-20 TRUCK WHEEL W/ 30% IMPACT PER AASHTO 6. FILL W/ CLEAN WATER PRIOR TO START UP OF SYSTEM 7. CONTRACTOR TO SUPPLY AND INSTALL ALL PIPING AND SANITARY TEE, AND CLEAN OUTS, FOR CLEANING TOWARD TRAP AND FOR CLEANING AWAY FROM TRAP ON BOTH THE INLET AND OUTLET/ALT. DUAL SWEEP CLEAN OUTS 8. GRAY WATER ONLY, BLACK WATER SHALL BE CARRIED BY SEPARATE SEWER. CONTRACTOR SHALL VERIFY EXACT LOCATION OF EX. WATERMAIN PRIOR TO ANY CONSTRUCTION. STREET RESTORATION WITH NEED TO BE DONE IN ACCORDANCE WITH CITY REQUIREMENTS. CONNECT NEW 6" D.I.P. TO EXISTING 12" D.I.P. BY WET TAP. INSTALL 6" G.V. PER CITY OF RENTON DETAIL B115 -CAUTION: CONTRACTOR SHALL LOCATE AND VERIFY DEPTH OF EXISTING UNDERGROUND POWER AND TELEPHONE PRIOR TO ANY UTILITY CONSTRUCTION. SSCO #5 CONNECT TO EXISTING 6" SIDE SEWER. PRIOR TO ANY SEWER OR GREASE TRAP CONSTRUCTION VERIFY THE LOCATION AND DEPTH OF THE EXISTING SIDE SEWER TO ENSURE 2.0% MIN SLOPE FROM SSCO#4. CONTACT BARGHAUSEN CONSULTING ENGINEERS IF MINIMUM POSITIVE SLOPE CANNOT BE ACHIEVED. RIM=t36.15 IE=33.23 (OR DEEPER) APPROXIMATE LOCATION OF EXISTING 6" SIDE SEWER 48 LF 6" PVC SDR-35 ® 2.00% MIN. CONTRACTOR TO VERIFY EX. SIDE SEWER DEPTH PRIOR TO ANY CONSTRUCTION. EX. 1 1/2" WATER 10INS11,LL 1•5n 996A IM a N METER TO REMAIN CONTRACTOR TO VERIFY ABOVE CaRoUNo Not b METER SIZE AND NOTIFY BARGHAUSEN CONSULTING St Nltt D KCIEL ENGINEERS IF EXISTING METERS ARE DIFFERENT THAN LISTED ON PLANS -EX. 1" IRRIGATION WATER - 1N STAU, I it IbLVA ICE mmo N tfef& METER TO REMAIN SEE LANDSCAPE PLANS NEW 2" POLY PIPE SERVICE LINE PER CITY STANDARDS EX. POWER AND TELEPHONE VAULTS 3 BID RELEASE 2 REVISED DRIVE-THRU 1 REVISED PER CITY COMMENT LETTER DATED 2/1 - PRE -APPLICATION MEETING NO. REVISION CID �` a J d' CID i W 0 Q Z 00 O Q D :3 U) Z N 0 � c co aQa tO Z O Qr c) r CU G F5 r N r _ U) 0 v F- z- O V) zN � � J Z X Q o Z w w N gZ Q N CV � O Cal 00 0 00 0) CN co r- 00 Z Q I I Zw Sa Lo Ln U Z .-..-. Ln w 00 Ld --d- Y4 CV) I EXPIRES 6-10- 11 CITY OF RENTON L7EPARTMENT OF PUBLIC WORKS AJ IH 03/31 /08 AJ IH 03/18/08 DESIGNED HPG 108 AJ IH 03/10/08 DRAWN CRJ AJ IH 01 /02/08 CHECKED HPG APPROVED HPG BY APPR. DATE c b s- 3y y 3 DATE 1/31/08 SCALE 1 "=20' DIRECTOR OF PUBLIC WORKS FILE NO. LUA 03- FIELD BOOK - -__ PAGE ' SHEET C7 OF 1�'F co N U) I 00 n Io i 00 N _c N X z w z W U N 6 U a- QID 00 O O N Lf) ro d I r� Q) O Q) i os "