Loading...
HomeMy WebLinkAboutWWP2703444.2PROJECTED PLATE a 44.4 Sq/ft MAXIMUM PROCESS FLOW = 415 GPM 6 8 Top Section 6 •:� V Co '2 32 2P, Galvanized �.. \ L aid Plate Cover rI�I ,yK 1,5 I� oA a A :i i I I I I PLAN VIEW _3/4' Did. Urt Insert 4 P acesIn Top Sec ion I l i t" U c _itt bie - _ zwn 1 Each Side, 2 5� -o�lesc'ny Media TOP ELEVATION INLET I.E. _ - r _ jU'_ v ~ - _ OUTLET I.E. n - Inlet 'Pipe With Samol ng Tee z --Cutlet Pine By Other - a. ip':�a T ., `v I m 1 Sediment dw• �.�Sc•. Media -Ci Retolning SECTI AA Baffle STRUCTI P L NOTES: NFDRMA.TtION NEEDED: 1, Cof fete <$ Day Compress ., St�eng c= 4500 cs: Top Of Separator Eleeat on; 2. ReCar STM. 615 Grade cc,rlet Pipe Size 3. Me n Set Pipe Ele at on 4. Design: t,l 318 0" Budd, Care Owlet Pipe Siz AS H L-8 ftirii t. "turoi Design Outlet Pipe Ele L ed ny'. For Ur rground ~recast Concrete U. rty St +� es" BSI CES'.GN 5, Loads N-2^ ruck Wheel w; 30% Impact Per AA.SIITQ c Gfa it i L Gill Sa ifiGrESa GENERA COTE.,: peroting Temperature 50' A affles and W'etrs To Be Precast Concrete rilient Oil Concentration 1 uC ppm 5loti Water Depth = 4 V `.lain Go Draplet Size 130 Microns 3. Contractor tu. 33 + Tiro. Rise Rate Supply a rd list II 111i piping &. Sampling Tees Designed Per Washing.or. State Department Of Ecology Grout h F',II pipes ln0/ Fill Wit` Clean '.'eater Prior To "Start -Up Of System _ OV EFFLUENT COLLECTED Verify RII BLockcut Sizes and Locations RATE QUALITY SIZE lio GPM 10 pt- 60 Ivticran TOP SECTION No. 660-CPS T 1,490 lbs. 80TLET PIPE .11 Sampling Tee Ey O he s PIPE TO BE _,f R LR Ti Vt IFJLET PI -,- VAULT No. 660-CPS-8 16ILZ Wfi,TOR /SEPARAXOW DE_�AIV CONCRETE BLOCKING SIZING PROCEDURE A. GENERAL The amount of concrete required to anchor horizontal bends, tees, and dead ends depends on the strength of the soil. The methods of placing concrete to keep the joint accessible is shown in Figure 1. The area in square feet of concrete which must bear against the side of the trench is found by dividing the thrust in pounds shown in Table 1 by the safe bearing load of the soil as shown in Table 2. B. CRITERIA 1. The sizing procedure is for horizontal or downward thrust only. 2. Height of the thrust block must be equal to or less than 1 /2 the depth from the ground surface to the block base. 3. The thrust block bearing face is approximately rectangular. 4. The concrete blocking shall be as per APWA Specification 74-2.14. C. SYMBOLS d = Outside Diameter of Pipe in Feet T = Thrust in Pounds at the Fitting (Table 1) SBL = Safe Bearing Load in Pounds/Sq. Ft. (Table 2) h = Depth of Trench in Feet W = Width of Trench in Feet A = Area of Concrete which must bear against the Side of the Trench in Sq. Ft. Hm = Maximum Height of the Thrust Block in feet Dc = Depth of the Concrete Thrust Block to Bearing Surface in Feet Lm = Maximum Length of the Thrust Block in Feet GROUND SUFACE h � d Hm` h 2 +- BLOCK BASS - I� Dc W E. EXAMPLE 4.-$„ �?a 0 •\\ � is l" ,.� �' `V r .0 / I g'_6 INLET PIPE With SamFding Tee By Withers 1. Problem: Calculation of the amount ofconcrete required to block a 90' bend in an 8" C.I. water main; the normal operating pressure in the pipe will be 65 psi and the soil condition in the area indicates sand and gravel. 2. Solution: Maximum testing pressure (See Table 1) = 300 psi. = 0.75 ft, - Outside diameter of 8 pipe = 9.05 in. = 9.05/12 - Go to Table 1: The testing pressure of 300 psi, we see that the thrust on a 90' bend is 21,360 pounds. - Go to Table 2: Table 2 gives the safe bearing load for sand and gravel: 3,000 lbs./sq. ft. - Go to Figure 1: figure 1 indicates the position of the concrete for blocking the 90' bend. - Go to the specifications of the project and find depth of trench (h) = 4 feet - Width of trench (W) = 3 feet With the above assembled information, we proceed to the final calculations: Thrust ,360 Area of Concrete (A) = Safe Bearing Load 3 i,000 - 7.12 sq ft. Maximum Height of Thrust Block (Hm) = Depth of Trench in Feet 2 h 4 2 = 2 = 2.0 ft. Depth of Concrete Thrust Block (Dc) Width of Trench in Feet (W) - Outside Diameter of Pipe (d 2 3 - 0.75 = 1.13 ft. 2 Maximum Length of Thrust Block (Lm) = Area of Concrete Height of Concrete A 7.12 = 3,56 ft. Hm 2.0 - Required Amount of Concrete = (Height x Depth x Length) x 0.03704 = (Hm x Lm x Dc) x 0.03704 = (2.0 x 3.56 x 1.13) x 0. 03704 = 0.30 cu. yd. D. CALCULATION EQUATIONS TABLE 1 1. Area of Concrete (A) = Thrust (In Pounds = Safe Bearing Load (In Pounds/Sq. Ft.) T SBL 2. Maximum Height of Thrust Block (Hm) - Depth of Trench in Feet h = 2 2 of Trench in Feet) - �Width Outside Diameter of Pipe in Feet) W-d 3. Depth of Concrete Thrust Block = - - 2 2 Area of Concrete A 4. Maximum Length of Thrust Block (Lm) Maximum Height Hm 5. Required Amount of Concrete (Cu. Yd.) = (Height x Depth x Length) x 0.03704 = (Hm x Lm x Dc) x 0.03704 Size Pressure PSI Thrust at Fittings in Pounds Tees 90' 45' 22-1 /2" 11-1 /4' Dead Ends Bend Bend Bend Bend 3" 300 2,120 3,000 1,630 830 430 4" 300 3,780 5,370 2,910 1,470 750 6" 300 8,500 12,000 6,510 3,320 1,700 8" 300 15,100 21,360 11,550 5,880 3,020 10" 275 21,620 30,570 16,540 8,430 4,330 12" 250 33,930 48,000 25,950 13,260 6,780 14" 250 46,200 65,370 35,340 18,030 9,240 16" 225 45,250 64,000 34,620 17,650 9,050 18" 200 50,900 72,000 38,940 19,860 10,180 20" 200 62,840 88,900 48,080 24,520 12,560 24" 200 90,480 127,980 69,200 35,320 18,100 30" 200 141,370 199,960 108,150 55,140 28,280 36" 200 203,580 287,950 155,740 79,400 40,720 CONCRETE BLOCKING PROCEDURE A OIL/WATER SEPARATOR NOT INSTALLED. ' SQUARES SPACED - 3/4" NDICATED - HT. 1 /8" 1 /21$ RAISE-1 /2" WIDE BORDER lost 9„ 8-3/4 1-1/4" 1 /2" 2r, r 5/8„ I I 2 Tv8pj 4>, 7" _ 7-3/4" 8" 15" CAST IRON RING AND COVER NOTE: IN UNIMPROVED AREAS POUR 1'-0" THICK 2'-0" SQUARE CONCRETE, CLASS 3000, PAD AROUND RING AND COVER. IN ASPHALT ROADWAYS RESTORE AROUND CLEANOUT RING AND COVER AS REQUIRED BY STANDARD DETAIL DRAWING BR36. PIPE MATERIAL AS SPECIFIED BY THE ENGINEER CONCRETE CLASS 3000 2'-0" 1'-0" �: r 12 "0 FIBER JOINT PACKING 45' (1/8) BEND STANDARD SANITARY CLEANOUT TABLE 2 Safe Bearing Loads i-i Lb. /Sq. Ft. The safe bearing loads given in the following table are for horizontal thrusts when the depth of cover over the pipe exceeds 2 feet, Safe Bearing Load SOIL Lb. per Sq. Ft. *Muck, peat, etc. 0 CLASS "B" A.C. PAVEMENT Soft Clay 1,000 Sand 2,000 MATCH EXISTING PAVEMENT Sand and Gravel 3,000 Sand and Gravel Cemented with Clay 4,000 Hard Shale 10,000 *In muck or peat, all thrusts shall be restrained by piles or tie rods to solid foundations or by removal of muck or peat and replacement with ballast of sufficient a stability to resist thrusts. a y. CAP TEE 22-1 /2 0 45 BEND FIGURE 1 NOTE: FOR CONVEX VERTICAL BENDS BLOCKING SEE APWA STANDARD PLAN NO. 73. FOR THE CITY OF RENTON PROCEDURE FOR CONCRETE BLOCKING SIZING WSDOT STANDARD SPECIFICATION CRUSHED SURFACING - TOP COURSE & KEYSTONE. PRECOVER 4-3/4" LANDSCAPE 1 /2" R. CROSSWALK I CV rLUG TO BE SEALED IN SAME MANNER AS MAIN SEWER JOINTS. 14' 12" LO 10 Z M U) C U) co M '� LO v �elf 0 c N E OCD CO U '0 N ti N U N cN Lr) G 0 InU) .` CY) C CD LO > (=)Ce LOJ Q C) CO Iz PARKING X9]I 1st R. FACE OF CURB CV 4 TOP OF A/C a d Q d a a a ° a a 9 1 /2" 12" CURB DETAIL SAWCUT (TYP) AI MATCH EXISTING PAVEMENT 'o a WSDOT STANDARD SPECIFICATION CRUSHED SURFACING BASECOURSE. 10 LANDSCAPE 7 1/2" PARKING BEDS LOT \ 5 1 /2" 2" 1 /2" R. /- 1 " R. TYPE "D" backfill. FACE OF SCURB D N p TOP D OF BEDDING o A/C FOR 8" PIPE (TYP) A. THICKNESS OF A.C. PAVEMENT AND CRUSHED ROCK TO BE IN CONFORMANCE WITH THE CITY OF RENTON OR WSDOT UTILITY PERMIT. B. CONTROLLED DENSITY FILL MAY BE REQUIRED BY THE CITY OF RENTON. C. ALL JOINTS TO BE TACKED, SEALED AND SANDED. D. A.C. LIFTS SHALL BE A MINIMUM OF 0.15' AND A MAXIMUM OF 0.35'. E. ALL GRANULAR MATERIALS TO BE COMPACTED TO 95% OF MAXIMUM DENSITY (T-99 METHOD). F. SEE APPROVED PLANS AND STANDARD DRAWINGS FOR PIPE ZONE AND BACKFILL REQUIREMENTS. PAVEMENT RESTORATION T. 10,11 0 WA3x 0?',t, 02 x 42986 9t"- ti ONAL� 5-344402 AlSHEET RECONFIGURED I vo D CV p D p o P D 9 1 /2" STANDARD CURB DETAIL DRAWINGS OF RECORD THESE DRAWINGS OF RECORD WERE COMPILED FROM SURVEY DATA, DATA COLLECTION BY OTHERS, AND PERIODIC OBSERVATION DURING CONSTRUCTION. IT IS SUGGESTED THAT THESE PLANS BE USED IN CONJUNCTION WITH FIELD VERIFICATION OF LOCATION AND ELEVATIONS OF IMPROVEMENTS IN QUESTION. THESE PLANS ARE AN ACCURATE RECORD OF PUBLIC IMPROVEMENTS TO THE BEST OF MY INFORMATION, KNOWLEDGE, AND BELIEF. , SIGNATURE 0� DATE C M WA3�jr a0C �@ � � x 3811_5 ONAL� �p d U J n n rn � z oN W Z m W z g N Z� 'n Z a LL V W OD H LU 1 Go (71 LO ci� W G C v Qa 00 LU N N U\ v Q 1 ti n Z O ' ^ Z LULn WV)Q00 OCoc0°' Z oC z ZW�0 ® zui (D O�w_z ZI ~Ow>= -1��� > UJ < <a-< OOZLLJ 01 ao0 >WmNFf WOMz Jm LLI Q a W � 0 O g zLi 00 o z o0 Of _O cn N 1 O) 0 N c0 w NW co� tY a a a l �--1 m Li � w z J 0 m t, = 0 z � o z 0 U �1 m :2 Z W O r� Pi z < U L z o tn M < Y F--1 00 m Y D F---1 W :E O O J wU = - c� N z r = Q� oU0 U� , SHEET NO. C4.4 I PACE PROJECT NUMBER 09827 DWG FILE: P09827-DS-2