Loading...
HomeMy WebLinkAboutTED4003446.100 U 0 m 0 w x x N r) O U N ON ® g 9 i CD 3 U-) U 0 a 0 Z w < U Cn g L1J w O z z w U CD w Q m z Q (J ry CD Q 1`O—i O U 0I w L) _ a. rn v .S m 0) C c v Z J W_ O o 2 U Z W2 ZO :08 (N o R8< cn z < 6 Q ow om B om W y, Z C7 w asa o_ 18" n Q LU Q 0 12" MAXIMUM OPENING OF GATE A PORTION OF THE NW �4 OF THE NE 4 OF SEC. 15, TWP. 23N., RGE. 5E., W.M. CITY OF RENTON, KING COUNTY, WASHINGTON LIFT HANDLE SHALL BE ATTACHED PER MANUFACTURER'S RECOMMENDATIONS r"ENLY SPACED HOLES FOR G TO FLANGE CONNECTION 4 97 EDIT NOTE 5 12 96 REFORMAT TO 1 1 %17" DATE REVISION 3' -0" 1 m SLOPE 0.05 FT/FT A , STREET SECTION d--------------------- Z O V) W 0 Z SECTION A -A HANDLE WITH LOCK PIN ADJUSTABLE LOCK HOOK WITH LOCK SCREW " ROD OR TUBING, I\RIABLE LENGTH LIFT HANDLE NOTES: 1. SHEAR GATE SHALL BE ALUMINUM ALLOY PER ASTM B-26—ZG-320 OR CAST IRON ASTM A48 CLASS 30B AS REQUIRED. 2. GATE SHALL BE 8" DIAMETER FOR PIPE 12 INCHES OR LESS IN DIAMETER, 12" DIAMETER FOR PIPES GREATER THAN 12". 3. GATE SHALL BE JOINED TO TEE SECTION BY BOLTING THROUGH FLANGE. 4. LIFT ROD: AS SPECIFIED BY MFR. WITH HANDLE EXTENDING TO WITHIN ONE FOOT OF COVER AND ADJUSTABLE HOOK LOCK FASTENED TO FRAME OR UPPER HANDHOLD. 5. GATE SHALL NOT OPEN BEYOND THE CLEAR OPENING BY LIMITED HINGE MOVEMENT, STOP TAB, OR SOME OTHER DEVICE. 6. NEOPRENE RUBBER GASKET REQUIRED BETWEEN RISER MOUNTING FLANGE AND GATE FLANGE. 7. MATING SURFACES OF LID AND BODY TO BE MACHINED FOR PROPER FIT. 8. FLANGE MOUNTING BOLTS SHALL BE 3/8" DIAMETER STAINLESS STEEL. 9. ALTERNATE SHEAR GATES TO THE DESIGN SHOWN ARE ACCEPTABLE, PROVIDED THEY MEET THE MATERIAL SPECIFICATIONS ABOVE. WIDENED CURB El FACE OF CURB PIVOTING SHEAR GATE DETAIL Y ADOPTED U�� CITY OF RENTON STANDARD PLANS LIST DATE: 4/97 DCV DT DCV DT BY APPR'D DWG. NAME: BR05 SP PAGE: B033 ON JOINTS NOTES: 1. 3° TO 5" DRAFT PERMITTED AS NEEDED. 2. WELDING NOT PERMITTED. 3. DIMENSIONS SHALL HAVE t1/16" TOLERANCE EXCEPT AS NOTED. 4. FOUNDRY NAME SHALL BE EMBOSSED ON TOP OF GRATE. LETTERING TO BE RECESSED 1 /16". 5. SEATING OF GRATE SHALL BE ACCOMPLISHED BY ONE OF THE FOLLOWING: ALTERNATE A SHALL BE 8 PADS, 1 1 /2"x 3/4% 1 /8" INTEGRALLY CAST WITH THE GRATE. ALTERNATE B SHALL BE A MACHINED SURFACE OUTSIDE A 17" CIRCLE, BOTTOM ONLY (SEE SECTION B-B). 6. MATERIALS IN ACCORD WITH DIVISION 9 OF STANDARD SPECIFICATIONS SECTION ''METAL FRAME AND GRATE FOR CATCH BASIN OR INLETS". 7. MATERIAL USED FOR GRATE SHALL BE DESIGNATED BY EMBOSSING "DI" (DUCT IRON) OR "CFS" (CAST STEEL) NEAR MFR'S NAME. 7. SEE DWG. NAME BR-32 FOR FRAME AND GRATE DETAIL. GRATE IS OLYMPIC FOUNDRY #SM50G, #SM50GL, #SM50SL, OR EQUAL. FRAME IS OLYMPIC FOUNDRY #SM50 OR EQUAL. 1RMAL GUTTER GRADE REVISION SURFACE WATER UTILITY OPEN CURB FACE FRAME & GRATE INSTALLATION DETAIL Y o ADOPTED U CITY OF RENTON p R STANDARD PLANS F N O LST DATE:12/96 BY APPR'D DWG. NAME: BR-30 SP PAGE: 6017 ADJUSTABLE HOOK FLANGED END 15' MIN CRUSHED SURFACING BASE COURSE (9-03.9(3)) v v v v v v v v v v v v v v v v v 2"7 v °v °v °v °v °v °v °v °v °v 77°17 4°°°° QUARRY SPALLS (2"— 4") 6" oAV 0�0 000 17,7 GEOTEXTILE FABRIC (MIRAFI 500X OR ��APPROVED EQUAL) COMPACTED SUBGRADE GRAVEL ACCESS PAD NOT —TO —SCALE VERTICAL DATUM: CITY OF RENTON, NAVD 88 BENCHMARK CITY OF RENTON BENCHMARK #2104. 1" IP W/PLUG & TACK DOWN 0.9' IN CASE LOCATED AT THE INTERSECTION OF SE 136TH ST. AND 144TH AVENUE SE. ELEV.=399.340 FEET (121.719 METERS) CHECKED FOR COMPLIANCE TO CITY STANDARDS Date-'„ ?1idY Date Date SPIGOT END TRENCH RESTORATION AND STREET OVERLAY REQUIREMENTS APPLICANT SHALL COMPLY WITH THE CITY OF RENTON'S TRENCH RESTORATION AND STREET OVERLAY REQUIREMENTS. r MAX. FACE VOID 6" 12" 141H. 1 OR FLATTER G" Of 5/01, (- Crushed Rock 2 OR PLATTER APPROVED FILTER FABRIC MAY BE REQUIRED UNDER CERTAIN SOIL CONOITIONS CHINK VOIDS, G" OR GREATER 12" MINIMUM 6" PERFORATED DRAIN PIPE, RUN I ST014M SEWER OR AS DIRECTED qv THE ENGINEER �— UNDISTURBED SOIL OR COMPACTED FILL THE LONG DIMENSION OF THE ROCKS SHALL EXTEND INTO THE EARTH TO PROVIDE MAX1t1Ul STABILITY, THE ROCK SHALL BE PLACED SO AS TO LOCK, INTO TWO ROCKS IN THE FIER. I I1AN ROCKS 150 LBS. HIN 300 LBS, MAX. SIZE 10" IN ITS LEAST DIMENSION 2 IdAN ROCKS 300 LBS. " 800 LBS. " SIZE 13" TO 18" 3 MAN ROCKS 800 LBS. " 1500 LBS. " SIZE 18" TO 24" 4 MAN ROCKS 1500 LBS. " 2100 LOS. SIZE 24" TO 32" 5 IiAN ROCKS 2100 LBS. 3000 LOS. " SIZE 30" TO 38" 'TINY ROCKERY GREATER THAN 4 FEET IN HEIGHT MUST BE DESIGNED AND INSPECTED BI A LICENSED ENGINEER WITH GEOTECHNICAL EXPERTISE, THE ENGINEER MUST CERTIFY TO TFIr CITY THE ROCKERY WAS INSTALLED IN ACCORDANCE WITH PLANS AND SPECIFICATIONS. ROCKERIES 7 FEET AND LOWER SIIALL BE CONSTRUCTED OF 4 INN TO 2 MAN ROCKS FROM BOTTOH TO TOP. ROCKERIES 7 FEET AND HIGHER SHALL BE CONSTRUCTED OF 5 14AN TO 2 MAN ROCKS FROi� BOTT014 TO TOP. R-3y'{61� NO. I REVISION CALL 48 HOURS BEFORE YOU DIG 1-800-424-5555 BY I APPR. I DATE �1 ROCKWALL DETAIL � NOT TO SCALE ro • SVilt�J�tRCIL W .q PO �3 j 223 ASSOCIATPS, PLw CIVIL ENQMRNlG 8 PROJECT MMANA Pf SIOI / 705 SOUTH 9TH STREET Bus: (253) 272-4451 `v SUITE #303 Fox. • (253) 272-4495 EXPIRES 09/20/08 TACOMA, WA 98405 bschw&l ftsacom CITY OF RENTON DEPARTMENT OF PUBLIC WORKS BECLAN PLACE STORM DRAINAGE NOTES AND DETAILS DESIGNED: BAS DRAWN: TAS CHECKED: BAS APPROVED: DATE: 04/14/08 FILE NAME: 05057-C12 SCALE: AS SHOWN FIELD BOOK: PAGE: SHEET: C-12 OF: 23 DIRECTOR OF PUBLIC WORKS