Loading...
HomeMy WebLinkAboutTED4003450.10A PORTION OF THE NW 1 /4 OF SECTION 15, TWP. 23 N., RGE. 5 E., W.M., KING COUNTY, WASHINGTON STREET SIGN SEE NOTE (TYP.) i � I 1 W I I z II f W l J Z w + C.O. IE=407.31 I W o I > Q o ♦ DRIVEWAY APPROACH PER Q Q ` DETAIL F004 ON SHEET II DT-04 (TYP) I Q \ z D F C.O. IE=405.08 - 6"0 S.D. 0 2% MIN (TYP) 3 C.O. IE=402.90 3' MIN. (TYP) 4 6"0 S.D. 0 S=2% MIN. CONNECTED T0� WALL DRAIN 5' PRIVATE JOINT UTILITY EASEMENT C.O. IE=400.20- - - C.O. IE_400.31- 101 +00 t 42' - 32 - 102+00 INT'X STA. 53+43.12, UNION AVE NE I - - = STA. 100+25.00, NE 2ND PLACE ' - - I ' C.B. #22 I SEE SHEET RD-01 ' SEE SHEET RD-01 @B CURB R TABLE BCR 1 /4 p 1/2 p 3/4 p L.P. ECR 420 410 400 390 STATION OFFSET ELEV. 103+23.97 16' LT. 397.82 ---- ---- 397.28 ---- --- 396.53 ---- ---- 395.95 200+66.06 16.31' LT. 395.85 200+70.00 16' LT. 395.90 p= 90'00; 00" R= 25.00' L=39.27' 30 ao N O Im 0 n 0 as / 8 Ln n 0 w '2 W o Cal 2 Working Days Before You Dig Uj 1-800-424-5555 W " Unties Underground Locabon Center u o (iD,MT,ND,OR,WA) O CURB TABLE BCR 1/4 p 1 /2 p 3/4 p ECR W Z w Q Z 0 Z cq Ki + to U) H x I Z V W U a 0 Z N w Z EXISTING 8"O D.I. W.M. STATION �eT ELEV. 104+05.97 16 LT. 395.41 ---- ---- 395.58 ---- ---- 395.65 ---- ---- 395.73 200+70.00 16' RT. 395.90 p=90'00'00" R=25.00' L=39.27' 2.03% O 00 0; PVI STA = 101 +00 PVI ELEV = 410.20 A. D. _ -3.40 K = 22.09 75.00' VC 100+40 100+80 CHECKED FOR COMPLIANCE TO CITY STANDARDS RENTON JOB NO. THICKENED EDGE SEE J PROPOSE[ DETAIL ON SHEET RD-01 SEWEf EXISTING GRAVEL DRIVEWAY. CONTRACTOR TO GAIN OWNER PERMISSION AND ADJUST GRADE USING SIMILARY MATERIAL AS REQUIRED. C.B. #7, TYPE 1 STA: 102+50.50, 17.99 RT PER DETAIL SHEET DT-06 NE 2ND PLACE (MINOR ACCESS) 20' 10' 0 20' 40' SCALE: 1 „= 20' HORIZ. 1 =10 VERT. VASHON AVE SE SEE SHEET RD-04 C.B. #8, TYPE 1 SEE SHEET RD-04 _to o I I' o + C.B. #5, TYPE 1 I I O 1 W/ ROUND FRAME " 57 L.F. 15 S.D. AND SOLID ROUND LID I[ i STA: 103+50.48, 15.23" LT. ; I n ' NE 2ND CT Lu NE2ND w {zJ ? 6 J � Z = Z Z _ r AC KEY MAP n 7 SIDEWALK RAMP SEE DETAIL F011 C.B. #6, TYPE 1 --t I ON SHEET DT-03 (TYP) STA: 102+50.50, 15.22 LT. I MAILBOX LOCATION / �`• a - C.B. #4, TYPE 1 STA. 103+00 � STA: 104+07.50, 15.53' LT. SEE DETAIL H026 ON - - SHEET DT-01 - - ` �� 0 NOTES: B c �, �d O 1. SEE SHEET HC-01 FOR HORIZONTAL CURVE DATA. 7 - - - - 2. SEE SHEET UT-01 FOR UTILITY CROSSING INFORMATION. 103+00 - - I - 104+00 3. EXISTING DRY UTILITIES SHALL BE REMOVED OR RELOCATED I - w tj BY THE APPROPRIATE UTILITY COMPANIES AND COORDINATED 100 L.F. 12*0 S.D. W WITH THE CONTRACTOR. NOTIFY THE ENGINEER OF ANY U j X DISCREPANCIES. - - Z _ Lv 4. CONTRACTOR SHALL RECORD ANY FIELD DEVIATION FROM - -- _ - - _ W THE ENGINEERING PLANS. THESE RECORDS SHALL BE KEPT - V U) ON CONSTRUCTION DRAWINGS AND TURNED OVER TO THE Q ENGINEER UPON COMPLETION OF THE PROJECT. INT'X STA. 200+29.00, VASHON AVE NE 5. STREET NAME SIGNS AND STOP SIGNS TO BE INSTALLED = STA. 103+64.97, NE 2ND PLACE PER CITY OF RENTON STANDARDS G012 & GO13. FINAL LOCATIONS TO BE DETERMINED DURING CONSTRUCTION BY THE CITY. SIGNS WILL NEED TO BE INSTALLED PRIOR TO AS-BUILTS AND COMPLETION OF CONSTRUCTION. EXISTING GRAVEL DRIVEWAY. EXISTING GRAVEL DRIVEWAY. 6. STORM RUNOFF FROM LOTS 23-27 TO BE DISCHARGED TO CONTRACTOR TO GAIN CONTRACTOR TO GAIN OWNER ADJACENT WETLAND/STREAM BUFFER VIA INDIVIDUAL LOT OWNER PERMISSION AND PERMISSION AND ADJUST GRADE FLOW DISPERSION TRENCHES. THE DOWNSPOUTS OF ALL ADJUST GRADE USING USING SIMILARY MATERIAL AS OTHER LOTS TO BE CONNECTED TO THE ROAD CONVEYANCE SIMILARY MATERIAL AS REQUIRED. SYSTEM VIA A PERFORATED PIPE CONNECTION. SEE DETAILS REQUIRED. ON SHEET DT-01. 7. ALL TRENCH RESTORATION SHALL BE PER THE CURRENT CITY OF RENTON TRENCH RESTORATION AND STREET OVERLAY DETAIL. r7 (D r- 00 O M N 00 O O cD O 0 0) 00 � (D w U-) It K) � 00 r7 00 Oi 00 (6 Ili 4 P6 N r- O 6 00 I-: tD tD 6 0 0 0 O O O O O o 0, rn rn rn rn rn 5 LIJ PROPOSED GRADE 0 OF ROAD EXISTING GRADE 0 OF ROAD 12"0 S.D. 0 S=1.82% -- -5.43� PROPOSED SEWER 101 +20 101 +60 0 FIRST SUBMITTAL 1 SECOND SUBMITTAL 2 THIRD SUBMITTAL 3 FOURTH SUBMITTAL 4 MYLARS N0. PVI STA = 103+40 PVI ELEV = 397.17 A. D. = 3.25 K = 23.09 75.00' VC 0 Lq O N + 0' K) 0) O 'o U m 2' MIN. COVER 100 L.F. " 12 S.D. ® S=5.18% I.E. = 398.22, 6"0 I.E. = 397.72, 12"0 102+00 102+40 I.E. = 398.32, 12" 0 102+80 ESM 10/15/200 SURVEYED: SCALE: 1 "s a ESM 1 31 2 / / DESIGNED ESM 0/22/201 ESM 2/06/201 DRAWN: M� M.Y ONE INCH ESM 2/22/201 1 CHECKED: AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY REVISION B Y DATE A P P R I APPROVED: w Q U d O 0 of z N O 0 w 0) z � N r n+� O rn 04 + 0O 0) c(D Q M cD w N O cD x 1`0 >EXISTING 8"0 z N II PVC SEWER C� II w -2.18% 57 L.F., 15" 0 S.D. 0 S=1.95% ALLOWABLE PIPE MATERIALS 1. REINFORCED CONCRETE PIPE. 2. DUCTILE IRON (WATER SUPPLY, CLASS 50 OR 52). 3. SOLID WALL POLYETHYLENE PIPE (SWPE; ALSO KNOWN AS HDPE PIPE OR HDPP). 4. CORRUGATED POLYETHYLENE PIPE (CPEP). W/ ROUND FRAME T.G. = 395.39 AND SOLID ROUND LID I.E. = 391.93, 6"0 T.G. = 396.80 I.E. = 391.18, 15" 0 I.E. = 392.54, 12"0R 3450 10 103+20 103+60 104+00 VERTICAL- NAVD 198B HORIZONTAL NAD 1983/1991 CITY OF GLADCO DEVELOPMENT, L.L.C. ;! "u RENTON ROSEWOOD HIGHLANDS DATUM Planning/Building/Public Works Dept. ROAD AND STORM PLAN AND PROFILE 344 3-4o 420 410 400 390 FIELDBOOK: PAGE: DRAWING N0: RD-02 SHEET: OF: 10 31 REVISIONS NO. DESCRIPTION DATE BY 0 FIRST SUBMITTAL ESM 10/15/2007 1 SECOND SUBMITTAL ESM 01/31/2008 2 THIRD SUBMITTAL ESM 10/22/2010 3 FOURTH SUBMITTAL ESM 12/06/2010 4 MYLARS 12/22/2010 ESM z 0 C9 z_ WN = 3 0 U W z J U- aOf Z = o W �z Z � O a J LLJ Q W O0 cn OZ O Q U3:o w O Q J v O Z z T. w U- O r C U tl810 j iru a: C ; o a °a 0 U w Z Z ® W s3 0 - Z w 0 c 0 vo00 .. E z ~ a )Jn E Z2 0 r03 U �Y Z 0 c ro - 30. CO O U -.3 "D .3 V r E - 3 ` 3 s0 a3 c W 0 = va L Sri 4 C/ST� s'ONAL � 2 �/o JOB NO.: 1352-001-006 DWG, NAME: RD-02 DESIGNED BY: KAO DRAWN BY: CLC CHECKED BY: DATE: 12/22/2010 DATE OF PRINT: RD-02 10 OF 31 SHEETS