HomeMy WebLinkAboutTED4003450.27NE 3RD COURT
CONSTRUCTION ENTRANCE PER STD
DETAIL 215.10 ON SHEET ER-03
0
POWER POLE TO BE
REMOVED/ RELOCATED
BY OTHERS
no
Cal 2 Working Days Before You Dig
1-800-424-5555
Util'Ities Underground Location Center
(ID,M'T,ND,OR,WA)
0
0
0
0
N
Ln
W
z
W
z
0
z
D
11
0
8
A PORTION OF THE NW 1/4 OF SECTION 15, TWP. 23 Nffl,
RGE. 5 E., W.M., KING COUNTY, WASHINGTON RECORD DRAWING
I CONSTRUCTION SEQUENCE
n. I
I I NOTE: REFER TO WET SEASON PROVISIONS ON SHEET ER-02 FOR ADDITIONAL EROSION CONTROL MEASURES THAT ARE
❑ REQUIRED FOR WET WEATHER CONSTRUCTION (BETWEEN OCTOBER 1 AND APRIL 30).
1. SCHEDULE A PRE -CONSTRUCTION SEQUENCE WITH THE CITY OF RENTON.
2. PRE -CONSTRUCTION MEETING.
3. POST SIGN WITH NAME AND PHONE NUMBER OF T.E.S.C. SUPERVISOR (MAY BE CONSOLIDATED WITH THE REQUIRED
NOTICE OF CONSTRUCTION SIGN).
4. FLAG OR FENCE CLEARING LIMITS.
❑ FP=403.75
5. INSTALL CATCH BASIN PROTECTION ON EXISTING STRUCTURES IF REQUIRED.
I
j FP-403.75 6. GRADE AND INSTALL CONSTRUCTION ENTRANCE(S),
1 I 7, INSTALL PERIMETER PROTECTION (SILT FENCE, BRUSH BARRIER, ETC.).
1 8. EXCAVATE TESC POND AND INSTALL POND RISER OUTLET.
9. GRADE AND STABILIZE CONSTRUCTION ROADS.
.----
1 `~ �� 10 CONSTRUCT SURFACE WATER CONTROLS (INTERCEPTOR DIKES PIPE SLOPE DRAINS ETC) SIMULTANEOUSLY WITH
SCALE: 1 = 20' I _�- - CLEARING AND GRADING FOR PROJECT DEVELOPMENT.
U( r o 11. MAINTAIN EROSION CONTROL MEASURES IN ACCORDANCE WITH CITY OF RENTON STANDARDS AND MANUFACTURER'S
20' 10' 0 20' 40' 1 % RECOMMENDATIONS.
CONTOUR INTERVAL = 2` 12. RELOCATE EROSION CONTROL MEASURES OR INSTALL NEW MEASURES SO THAT AS SITE CONDITIONS CHANGE THE
1 !� ---- EROSION AND SEDIMENT CONTROL IS ALWAYS IN ACCORDANCE WITH THE CITY OF RENTON EROSION AND SEDIMENT
NGPE FENCE TO BE PLACED-- CONTROL STANDARDS.
AT CLEARING LIMITS. 1 1".11 o
13. COVER ALL AREAS THAT WILL BE UNWORKED FOR MORE THAN SEVEN DAYS DURING THE DRY SEASON OR TWO DAYS
- - - - -- --- - - - CLEARING LIMITS I
INTERCEPTOR SWALE WITH
CHECK DAMS SEE DETAILS
ON SHEET ER-03
403+00
II
I
402+00
-- - NE 2ND COURT
I ,
4BOT 403,8
I
FP=409.75
I
o TOP 409.8
FP=409.75
;n TOP 409.8 LOTOP 409.8
N
BOT 407.8
�
BOT 405.3 41BOT
405.3
IoITOP
409.8
N
BOT 407.3
I
ROCKERY DESIGN
NOTE:
BY OTHERS
I
ALL BUILDINGS, FENCES AND
STRUCTURES TO BE REMOVED
I
I
WITHIN PROJECT BOUNDARY.
OR SWALE WITH
INTERCEPT-�
I
I
CHECK DAMS SEE DETAILS
ON SHEET ER-03
f
I
FP=4 ! 1.25
I
FP=409.25
FP=407.25 �
FP=405.25
I
CATCH BASIN FILTER
(TYP) PER STD PLAN
216.30 ON SHEET ER-03
7
+
�
TOP 404.7 p it
BOT 404.1 0 �
FP=404,75
TOP 410.7 0
BOT 404.76 ROCKERY DESIGN
BY OTHERS
1
TOP 406.5 cv
BOT 404.3 N -
401 +0
1
TOP 406.0 cal
BOT 403.8 N
FP=403.75
1
TOP 409.8[0
BOT 403.8
TOP 405.3 Ln
BOT 401.8 In
FP=401.75 + f
ROCKERY DESIGN
BY OTHERS
J
TOP 405.3 L I
BOT 400.8
FP=400.75 1
1
102+00
- � 103+00
CLEARING LIMITS N E 2N D PLACE__/_
- I -- -
EXISTING GRAVELED DRIVE. CONTRACTOR TO GAIN OWNER -� - -o-- •
PERMISSION AND ADJUST GRADE USING SIMILAR MATERIAL
AS REQUIRED. MAINTAIN ACCESS DURING CONSTRUCTION.
CHECKED FOR COMPLIANCE E SECOND SUBMITTAL
TO CITY STANDARDS 2 THIRD SUBMITTAL
3 FOURTH SUBMITTAL
4 MYLARS
5 CONSTRUCTION SET
REVISION
RENTON JOB NO.
N
gk
41.4
W
V
W
Z
J
U
Q
SURVEYED: SCALE:
ESM 1/3?;r200 VERTICAL: NAVD 1988
ESM 10;�22%201 af HORIZONTAL NAD 1983/199-
DESIGNED: 1 1 =20
ESM 12/06/201 rim
ESM 12/22/201 DRAWN:
ONE '"°" DATU M
ESM 02/24/2011 CHECKED: AT FUL, SCALE
IF NOT ONE INCH
•� ` DATE it P P R APPROVED: SCALE ACCORDINGLY
DURING THE WET SEASON WITH STRAW, WOOD FIBER MULCH, COMPOST, PLASTIC SHEETING OR EQUIVALENT.
14, STABILIZE ALL AREAS THAT REACH FINAL GRADE WITHIN SEVEN DAYS.
15. SEED OR SOD ANY AREAS TO REMAIN UNWORKED FOR MORE THAN 30 DAYS.
16. INSTALL STORM DRAINAGE SYSTEM WITH TEMPORARY CATCH BASIN PROTECTION.
18. EXCAVATE AND CONSTRUCT STORMWATER VAULT.
19. INSTALL ALL OTHER UTILITIES, CURB, GUTTER, SIDEWALK AND PAVING.
20. CLEAN DETENTION SYSTEM AS NECESSARY.
21. UPON COMPLETION OF THE PROJECT, ALL DISTURBED AREAS MUST BE STABILIZED AND BMPS REMOVED IF
APPROPRIATE.
MULCH STANDARDS AND GUIDELINES
MULCH
QUALITY
APPLICATION
MATERIAL
STANDARDS
RATES
REMARKS
STRAW
AIR-DRIED; FREE FROM
2"-3" THICK; 2-3
COST-EFFECTIVE PROTECTION WHEN APPLIED
UNDESIRABLE SEED
BALES PER 1000 SF OR
WITH ADEQUATE THICKNESS. HAND -APPLICATION
AND COARSE MATERIAL
2-3 TONS PER ACRE
GENERALLY REQUIRES GREATER THICKNESS THAN
BLOWN STRAW. STRAW SHOULD BE CRIMPED TO
AVOID WIND BLOW. THE THICKNESS OF STRAW
MAY BE REDUCED BY HALF WHEN USED IN
CONJUNCTION WITH SEEDING.
WOOD FIBER
NO GROWTH INHIBITING
APPROX. 25-30 LBS
SHALL BE APPLIED WITH HYDROMULCHER. SHALL
CELLULOSE
FACTORS
PER 1000 SF OR
NOT BE USED WITHOUT SEED AND TACKIFIER
1000-1500 LBS PER
UNLESS THE APPLICATION RATE IS AT LEAST
ACRE
DOUBLED. SOME WOOD FIBER WITH VERY LONG
FIBERS CAN BE EFFECTIVE AT LOWER
APPLICATION RATES AND WITHOUT SEED OR
TACKIFIER.
COMPOST
NO VISIBLE WATER OR
2" THICK MIN.;
MORE EFFECTIVE CONTROL CAN BE OBTAINED BY
DUST DURING
APPROX. 100 TONS
INCREASING THICKNESS TO 3". EXCELLENT
HANDLING. MUST BE
PER ACRE (APPROX.
MULCH FOR PROTECTING FINAL GRADES UNTIL
PURCHASED FROM
800 LBS PER YARD)
LANDSCAPING BECAUSE IT CAN BE DIRECTLY
SUPPLIER WITH SOLID
SEEDED OR TILLED INTO SOIL AS AN
WASTE HANDLING
AMENDMENT. SOURCES FOR COMPOST ARE
PERMIT,
AVAILABLE FROM THE KING COUNTY COMMISSION
FOR MARKETING RECYCLABLE MATERIALS AT
(206) 296-4439.
CHIPPED SITE
AVERAGE SIZE SHALL
2" MINIMUM
THIS IS A COST-EFFECTIVE WAY TO DISPOSE OF
VEGETATION
BE SEVERAL INCHES.
THICKNESS
DEBRIS FROM CLEARING AND GRUBBING, AND IT
ELIMINATES THE PROBLEMS ASSOCIATED WITH
BURNING. GENERALLY, IT SHOULD NOT BE USED
ON SLOPES ABOVE APPROX. 10% BECAUSE OF
ITS TENDENCY TO BE TRANSPORTED BY RUNOFF.
IT IS NOT RECOMMENDED WITHIN 200 FEET OF
SURFACE WATERS. IF SEEDING IS EXPECTED
SHORTLY AFTER MULCH, THE DECOMPOSITION OF
THE CHIPPED VEGETATION MAY TIE UP NUTRIENTS
IMPORTANT TO GRASS ESTABLISHMENT.
EXISTING GRAVELED DRIVE. CONTRACTOR
TO GAIN OWNER PERMISSION AND
ADJUST GRADE USING SIMILAR MATERIAL
AS REQUIRED. MAINTAIN ACCESS
DURING CONSTRUCTION.
SILT FENCE TO BE PLACED AT
CLEARING LIMITS. SEE STD PLAN
214.00 ON SHEET ER-03
R=345027
CITY OF
RENTON
Planning;/BuiIding,'Public Works Dept.
GRADING QUANTITIES
STRIPPING (12- DEPTH) = 5,497 C.Y.
CUT = 3,616 C.Y.
FILL = 7,519 C.Y.
NET (CUT) = 1,594 C.Y.
EARTHWORK QUANTITIES ARE FOR PERMIT PURPOSES ONLY,
QUANTITIES ARE "NEAT LINE" ONLY. THE QUANTITIES DO NOT
ACCOUNT FOR ANY SHRINK OR SWELL FACTORS. IT IS THE
CONTRACTORS RESPONSIBILITY TO CALCULATE THE
EARTHWORK VOLUMES FOR BID PURPOSES.
GLADCO DEVELOPMENT, L.L.C.
ROSEWOOD HIGHLANDS FIELDBOOK:
PAGE
DRAWING NO:
T.E.S.C. AND GRADING PLAN ER-01
SHEET: 5 OF.3111
REVISIONS
NO.
DESCRIPTION/DATE
BY
SECOND SUBMITTAL
ESM
01/31%2008
THIRD SUBMITTAL
ESM
10/22/2010
3
FOURTH SUBMITTAL
ESM
12/06/2010
a
MYLARS
12/22/2010
ESM
CONSTRUCTION SET
ESM
02/24/2011
6
AS BUILTS
09/t2/2011
ESM
T
AS BUILT MYLARS
ESM
10/19/2011
z
O
F-
U
z
U2:
N
/
3
V
J
Z
J
Z
�
Z
=
�
W
0
Z_
O
T
I
Ill
Q
Q
LU
0
.
U
0
o
vi
O
W
U
H
0
w
Q
J
U)
v
O
Z
F-
Z
W
O
�7__
U
�OcO
0 emN
N
�<
cn
_
o a
d a
LU ® z
U
v v
cc
z
ii
J J
0
-
z
w
0
c;
i o
20 000
,.
c
E
z
(o - 0)
<
rn
~
� 5
oc
z�
J
0
m N >,
o
:3.�
(n
�m
z
_
cl)
c0
J d
0
U
�� a
0 LL
m
rn
3
`
3
°Y
�0
0'3
c
w0
3
Ud
� %t L sr
,ham
42 Q
O/STEM
S��NAL `
r
JOB No, 1352-001-006
DWG
NAME:
ER-0"
DESIGNED BY:
KAO
DRAWN BY
CLC
CHECKED BY.
DATE.
10 /19,/201 1
DATE
OF
PRINT_
ER-01
5
01731 SHEETS
I
-w