Loading...
HomeMy WebLinkAboutTED4003450.300 o= I �- Im a im 0 0 is 0 0 i 10 oa w Cal 2 Working Days Before You Dig CD Q j 1-800-424-5555 Utlities Underground location Center 'w (ID,MT,ND,0R,WA) do A PORTION OF THE NW 1/4 OF SECTION 15, TWP. 23 N., RGE. 5 E., W.M., KING COUNTY, WASHINGTON STORM NOTES: 1: STORM RUNOFF FROM LOTS 23-27 TO BE DISCHARGED TO ADJACENT WETLAND/STREAM BUFFER VIA INDIVIDUAL LOT FLOW DISPERSION TRENCHES. THE DOWNSPOUTS OF ALL OTHER LOTS TO BE CONNECTED TO THE ROAD CONVEYANCE SYSTEM VIA A PERFORATED PIPE _ CONNECTION. SEE DETAILS ON SHEET DT-01. 2: SINGLE FAMILY RESIDENCES AND OTHER IMPROVEMENTS CONSTRUCTED ON LOTS CREATED BY THIS SUBDIVISION MUST IMPLEMENT FLOW CONTROL BMPS, UNLESS CONSTRUCTED AS PART OF THIS SUBDIVISION. _ _ COMPLIANCE WITH THIS REQUIREMENT WILL BE - ADDRESSED IN THE DRAINAGE PLAN SUBMITTED FOR RESIDENTIAL BUILDING PERMIT DRAINAGE REVIEW WHEN -'---� I INT'X STA. 203+76.40, NE 2ND CT APPLICATION IS MADE FOR A SINGLE FAMILY RESIDENTIAL �. � � �" I STA. 300+30.00, VASHON PL NE BUILDING PERMIT FOR EACH LOT. � STORMWATER ! 3: HOME OWNERS ASSOCIATION IS RESPONSIBLE FOR MAINTENANCE AND OPERATION OF THE STORMWATER -- VAULT I VAULT. 4: 1 p FLOW CONTROL BMPS CONSTRUCTED ON THE LOTS O I SHALL BE OPERATED, MAINTAINED AND KEPT IN GOOD REPAIR BY EACH LOT OWNER. 5: THE RESTRICTED FOOTPRINT FLOW CONTROL BMP HAS - 6 BEEN UTILIZED FOR THIS PLAT. EACH LOT IS LIMITED TO 2,300 SF OF IMPERVIOUS AREA. - VASHON PL NE_ - 5 - 12 :i I j 11 9 ! INT'X STA. 302+42.00, VASHON PL NE ' I ! = STA. 105+23.97, NE 2ND PLACE F i] _ 0 zz z J I 13 14 15 19 4 I 20 • - .. ... .. ...... 'T� I . .............................................................. ... EXISTING FIRE HYDRANT : V :. ASHON AVE NE ' 18 •b 1-7 16' 3 I I� INT'X STA. 200+29.00, VASHON AVE NE I = STA. 103+64.97, NE 2ND PLACE IIz N lz ! I1 I •y INT'X STA. 400+30.00, NE 2ND CT STA. 201 +97.08, VASHON AVE NE I I I I I t: t.lI ' c: - t: 1 0 I t: t: I Q F: • I I N ' I LU1 ! EXISTING FIRE I I HYDRANT I' - - I CHECKED FOR COMPLIANCE TO CITY STANDARDS RENTON JOB NO. INT'X STA. 51 +75.10, UNION AVE NE INT'X STA. 53+43.12, UNION AVE NE STA. 403+73.50, NE 2ND COURT = STA. 100+25.00, NE 2ND PL 1 1 NE 2ND CT w z N z Uj yyJJ < JJ z z N = > NE 2ND PLACE 1 1 KEY MAP n SCALE: 1 " = 50' 50' 25' 0 50' 100, UTILITY CROSSING TABLE STA. 102+57.00, , 3.40 LT. IE=397.42 SD CR=396.42 WA* STA. 102+57.00, 3.35' LT. O IE=397.32 SD CR=395.81 SS STA. 103+64.40, 15.30' LT. 3 IE=392.02 SD CR=390.87 SS STA. 103+74.97, 15.36 LT, ® IE=391.81 SD CR=390.81 WA* STA. 105+28.97, , 0.51 LT. O IE=389.34 WA* CR=383.35 SS STA. 105+34.22, 14.49 RT. 6 IE=389.07 WA* CR=388.71 SD STA. 105+34.31, 1.75' RT. O IE=386.91 SD CR=383.28 SS STA. 302+15.39, 5.00' LT. ® IE=389.58 WA CR=386.80 SD STA. 302+15.14, 6.06' RT. O IE=387.35 SD CR=383.90 SS STA. 300+45.22, 5.00' LT. 1 p IE=394.41 SD CR=393.37 WA STA. 300+45.22, 6.00' RT. 11 IE=394.83 SD CR=386.96 SS STA. 300+35.00, 6.00' RT. Q IE=395.49 WA CR=387.15 SS STA. 202+60.06, 6.33' LT. 13 IE=397.79 SD CR=394.74 SS STA. 202+64.79, 4.52' RT. 14 IE=397.66 SD CR=396.61 WA STA. 201 +91.92, 0.89' LT. 15 IE=399.16 WA CR=395.35 SS STA. 201 +96.82, 26.91' LT. 16 IE=398.69 SD CR=396.38 SS STA. 201 +90.22, 23.33' LT. IE=398.41 SD CR=397.41 WA STA. 201 +56.87, 0.57' LT. 1 g IE=397.86 SD CR=394.29 SS STA. 201 +56.94, 10.00' RT. 1 g O IE=398.08 SD CR=397.00 WA STA. 103+74.97, , 4.28 LT. p IE=392.65 WA* CR=389.96 SS * = FIELD ADJUST/DEFLECT WA = WATER LINE IF NECCESSARY SD = STORM DRAIN IE = INVERT ELEVATION SS = SANITARY SEWER CR = CROWN NOTE: VERIFY EXISTING WATER MAIN ELEVATIONS AND DEFLECT VERTICALLY AS NEEDED TO AVOID CONFLICT WITH GRAVITY UTILITY LINES. R-345030 RECORD DRAWING SECOND SUBMITTAL ESM 1/31/200 suRVEYEo: scA VERTICAL: NAVD 1988 2 THIRD SUBMITTAL ESM 10/22/201 C DESIGNED:GLADCO DEVELOPMENT, L.L.C. • ' HORIZONTAL: NAD 1983/183/1991 �� CITY OF � s'jQ FOURTH SUBMITTAL ESM 12/06/201 ROSEWOOD HIGHLANDS P GD600K: MYLARS ESM 12/22/201 DRAW _III& RENTON ONE INCH I DATUM DRAWING NO: CONSTRUCTION SET ESM 02/24/2011CHECKED: P COMPOSITE UTILITY PLAN AT FULL SCALE Planning/Building/Public Works De t. UT-01 IF NOT ONE INCH REVISION DATE APPR APPROVED: SCALE ACCORDINGLY SHEET: IF: 31 REVISIONS NO. DESCRIPTION DATE BY 1 SECOND SUBMITTAL ESM 01/31/2008 2 THIRD SUBMITTAL ESM 10/22/2010 3 FOURTH SUBMITTAL ESM 12/06/2010 4 MYLARS 12/22/2010 ESM 5 CONSTRUCTION SET ESM 02/24/2011 6 AS BUILTS 09/12/2011 ESM 7 AS BUILT MYLARS ESM 10/19/2011 z O c� z U Fc N 3 r� V Z J Q Z Z = 5 W a- 0 =� J � W Q F- 00 a OO O U U Lij Q V O Z F- z W Ir - O U m000 U � r�rnm J O � J pIA1 ONQ. O r N �< U) Q - ; c v a d o LLIU W ® c z w J Jc C7 - z LU 0 (� o To 000 r c E z - �r Q o� ' J co (n T 0 fij Z n (n r _ 00 Z O �� Ja CJ m Ii E - 3 3 3 OY �L- 0 6'3 c WV •2 3 Ud 42 s�ONAL'� ZO JOB NO.: 1352-001-006 DWG. NAME: UT-01 DESIGNED BY: KAO DRAWN BY: CLC CHECKED BY: DATE: 10/19/2011 DATE OF PRINT: UT-01 8 OF 31 SHEETS -, A `