HomeMy WebLinkAboutTED4003450.5NE 3RD COURT
CONSTRUCTION ENTRANCE PER STD
DETAIL 215.10 ON SHEET ER-03
no
Q)
POWER POLE TO BE
REMOVED/ RELOCATED
BY OTHERS
a
Cal 2 Working Days Before You Dig
1-800-424-5555
Unties Underground Location Center
(D,iMT,ND,C>RWA)
A PORTION OF THE
NW 1/4 OF SECTION 15, TWP. 23
N. RGE. 5 E.
W.M., KING COUNTY,
WASHINGTON
- -
- -
CONSTRUCTION SEQUENCE
I
(-
- - - ---
I
NOTE: REFER TO WET SEASON PROVISIONS ON SHEET ER-02 FOR ADDITIONAL EROSION CONTROL MEASURES THAT ARE
REQUIRED FOR WET WEATHER CONSTRUCTION (BETWEEN OCTOBER 1 AND APRIL 30).
I
I
I
1. SCHEDULE A PRE -CONSTRUCTION SEQUENCE WITH THE CITY OF RENTON.
I
2. PRE -CONSTRUCTION MEETING.
_
y
3. POST SIGN WITH NAME AND PHONE NUMBER OF T.E.S.C. SUPERVISOR (MAY BE CONSOLIDATED WITH THE REQUIRED
NOTICE OF CONSTRUCTION SIGN).
I
FP=403.75
4. FLAG OR FENCE CLEARING LIMITS.
5. INSTALL CATCH BASIN PROTECTION ON EXISTING STRUCTURES IF REQUIRED.
I
I
FP=403.75
6. GRADE AND INSTALL CONSTRUCTION ENTRANCE(S).
I
7. INSTALL PERIMETER PROTECTION (SILT FENCE, BRUSH BARRIER, ETC.).
I
8. EXCAVATE TESC POND AND INSTALL POND RISER OUTLET.
II
I
I
9. GRADE AND STABILIZE CONSTRUCTION ROADS.
„
SCALE: 1 = 20
��
10 CONSTRUCT SURFACE WATER CONTROLS (INTERCEPTOR DIKES, PIPE SLOPE DRAINS, ETC.) SIMULTANEOUSLY WITH
0
i
I
/ \
CLEARING AND GRADING FOR PROJECT DEVELOPMENT.
o
+
20' 10' 0 20' 40'
❑
T
/
'
11. MAINTAIN EROSION CONTROL MEASURES IN ACCORDANCE WITH CITY OF RENTON STANDARDS AND MANUFACTURER'S
RECOMMENDATIONS.
I
CONTOUR INTERVAL = 2'
12. RELOCATE EROSION CONTROL MEASURES OR INSTALL NEW MEASURES SO THAT AS SITE CONDITIONS CHANGE THE
I
1
EROSION AND SEDIMENT CONTROL IS ALWAYS IN ACCORDANCE WITH THE CITY OF RENTON EROSION AND SEDIMENT
CONTROL STANDARDS.
NGPE FENCE TO BE PLACED
AT CLEARING LIMITS. I
I/
-I
13. COVER ALL AREAS THAT WILL BE UNWORKED FOR MORE THAN SEVEN DAYS DURING THE DRY SEASON OR TWO DAYS
I- - - - - - - - - - - - -
- -
10,
DURING THE WET SEASON WITH STRAW, WOOD FIBER MULCH, COMPOST, PLASTIC SHEETING OR EQUIVALENT.
406
- - - - - - - - -
14. STABILIZE ALL AREAS THAT REACH FINAL GRADE WITHIN SEVEN DAYS.
I TOP
407.0 Co
a
I
- - - - - - - - - - - - - - CLEARING LIMITS I
INTERCEPTOR SWALE WITH
CHECK DAMS SEE DETAILS
ON SHEET ER-03
408
403+00
402+00
--+ -- --------
-NE 2ND COURT.
I -
I i� TOP 408.5
BOT 403.8
I
I FP=409.75
I o TOP 409.8
c BOT 407.8
N4
t
I
1
I NOTE: I
ALL BUILDINGS, FENCES AND
I STRUCTURES TO BE REMOVED
WITHIN PROJECT BOUNDARY.
I
I
I = I
FP 41 1.25 I
FP-409 25
In TOP 409.8 FP=409.75WTOP 409.8
ROT 4n5 � 1 4 BOT 405.3
409.8
407.3
ROCKERY DESIGN
BY OTHERS 41
1
INTERCEPTOR SWALE WITH -
CHECK DAMS SEE DETAILS
ON SHEET ER-03
I
I I - FP=407.25 FP=405.25
I I
I
CATCH BASIN FILTER
\ �17 (TYP) PER STD PLAN
216.30 ON SHEET ER-03
- _j_ _1z
CHECKED FOR COMPLIANCE
TO CITY STANDARDS
RENTON JOB NO.
FP=404.75
P 407.5
_
405.0
_
�'ROCKERY DESIGN
BY OTHERS
L_�BOT
TOP 406.0
o
-
N
BOT 4 5.0
- -
O
401 +O
Ld
W
TOP 406.0
cv
LLJ
BOT 403.8 ci
Z
J
FP=403.75
=
H
Q
TOP 409.8
0
)
B01
TOP 405.3 4n
�J
FP=401.75 I
I
ROCKERY DESIGN / I
BY OTHERS Q�
TOP 405.3 O�I
BOT 400. r
FP=400.75 I
I
-� ►--- -------- �...
01 +00' - 102+ - - - - - - - - - - - - -
- I - 00
/ 1 13,+ -
O / 0 CLEARING LIMITS o NE 2ND PLACE I) - -
�t- Ni-� v / o �b
-_..[�-�
%EXISTING GRAVELED DRIVE. CONTRACTOR TO GAIN OWNER � - -(}-
PERMISSION AND ADJUST GRADE USING SIMILAR MATERIAL
AS REQUIRED. MAINTAIN ACCESS DURING CONSTRUCTION.
0 FIRST SUBMITTAL
1 SECOND SUBMITTAL
2 THIRD SUBMITTAL
3 FOURTH SUBMITTAL
4 MYLARS
NO.
-D---[}---E]----p_-
--C---❑_
ESM 10/15/200 SURVEYED: SCALE. VERTICAL: NAVD 1988
-s20 • HORIZONTAL: NAD 1983/1991
ESM 1 / 31 / 2 DESIGNED:
ESM 10/22/201 m
ESM 12/06/201 DRAWN: C
�E INCHINCH DATUM
ESM 12/22/201 CHECKED:
AT FULLS
F NOT ONE INCH
SICALE ACCORDINGLY
REVISION BY DATE APPR APPROVED:
15. SEED OR SOD ANY AREAS TO REMAIN UNWORKED FOR MORE THAN 30 DAYS.
16. INSTALL STORM DRAINAGE SYSTEM WITH TEMPORARY CATCH BASIN PROTECTION.
18. EXCAVATE AND CONSTRUCT STORMWATER VAULT.
19. INSTALL ALL OTHER UTILITIES, CURB, GUTTER, SIDEWALK AND PAVING.
20. CLEAN DETENTION SYSTEM AS NECESSARY.
21. UPON COMPLETION OF THE PROJECT, ALL DISTURBED AREAS MUST BE STABILIZED AND BMPS REMOVED IF
APPROPRIATE.
MULCH STANDARDS AND GUIDELINES
MULCH
MATERIAL
QUALITY
STANDARDS
APPLICATION
RATES
REMARKS
STRAW
AIR-DRIED; FREE FROM
2"-3" THICK; 2-3
COST-EFFECTIVE PROTECTION WHEN APPLIED
UNDESIRABLE SEED
BALES PER 1000 SF OR
WITH ADEQUATE THICKNESS. HAND -APPLICATION
AND COARSE MATERIAL
2-3 TONS PER ACRE
GENERALLY REQUIRES GREATER THICKNESS THAN
BLOWN STRAW. STRAW SHOULD BE CRIMPED TO
AVOID WIND BLOW. THE THICKNESS OF STRAW
MAY BE REDUCED BY HALF WHEN USED IN
CONJUNCTION WITH SEEDING.
WOOD FIBER
NO GROWTH INHIBITING
APPROX. 25-30 LBS
SHALL BE APPLIED WITH HYDROMULCHER. SHALL
CELLULOSE
FACTORS
PER 1000 SF OR
NOT BE USED WITHOUT SEED AND TACKIFIER
1000-1500 LBS PER
UNLESS THE APPLICATION RATE IS AT LEAST
ACRE
DOUBLED. SOME WOOD FIBER WITH VERY LONG
FIBERS CAN BE EFFECTIVE AT LOWER
APPLICATION RATES AND WITHOUT SEED OR
TACKIFIER.
COMPOST
NO VISIBLE WATER OR
2" THICK MIN.;
MORE EFFECTIVE CONTROL CAN BE OBTAINED BY
DUST DURING
APPROX. 100 TONS
INCREASING THICKNESS TO 3". EXCELLENT
HANDLING. MUST BE
PER ACRE (APPROX.
MULCH FOR PROTECTING FINAL GRADES UNTIL
PURCHASED FROM
800 LBS PER YARD)
LANDSCAPING BECAUSE IT CAN BE DIRECTLY
SUPPLIER WITH SOLID
SEEDED OR TILLED INTO SOIL AS AN
WASTE HANDLING
AMENDMENT. SOURCES FOR COMPOST ARE
PERMIT.
AVAILABLE FROM THE KING COUNTY COMMISSION
FOR MARKETING RECYCLABLE MATERIALS AT
(206) 296-4439.
CHIPPED SITE
AVERAGE SIZE SHALL
2" MINIMUM
THIS IS A COST-EFFECTIVE WAY TO DISPOSE OF
VEGETATION
BE SEVERAL INCHES.
THICKNESS
DEBRIS FROM CLEARING AND GRUBBING, AND IT
ELIMINATES THE PROBLEMS ASSOCIATED WITH
BURNING. GENERALLY, IT SHOULD NOT BE USED
ON SLOPES ABOVE APPROX. 10% BECAUSE OF
ITS TENDENCY TO BE TRANSPORTED BY RUNOFF.
IT IS NOT RECOMMENDED WITHIN 200 FEET OF
SURFACE WATERS. IF SEEDING IS EXPECTED
SHORTLY AFTER MULCH, THE DECOMPOSITION OF
THE CHIPPED VEGETATION MAY TIE UP NUTRIENTS
IMPORTANT TO GRASS ESTABLISHMENT.
EXISTING GRAVELED DRIVE. CONTRACTOR
TO GAIN OWNER PERMISSION AND
ADJUST GRADE USING SIMILAR MATERIAL
AS REQUIRED. MAINTAIN ACCESS
DURING CONSTRUCTION.
SILT FENCE TO BE PLACED AT
-LEARING LIMITS. SEE STD PLAN
214.00 ON SHEET ER-03
R=345005
��- CITY OF
RENTON
Planning/Building/Public Works Dept.
GRADING QUANTITIES
STRIPPING (12- DEPTH) = 5,497 C.Y.
CUT = 3,616 C.Y.
FILL = 7,519 C.Y.
NET (CUT) = 1,594 C.Y.
EARTHWORK QUANTITIES ARE FOR PERMIT PURPOSES ONLY.
QUANTITIES ARE "NEAT LINE" ONLY. THE QUANTITIES DO NOT
ACCOUNT FOR ANY SHRINK OR SWELL FACTORS. IT IS THE
CONTRACTORS RESPONSIBILITY TO CALCULATE THE
EARTHWORK VOLUMES FOR BID PURPOSES.
GLADCO DEVELOPMENT, L.L.C.
ROSEWOOD HIGHLANDS FIELDBOOK:
PAGE
DRAWING NO:
T.E.S.C. AND GRADING PLAN ER-01
SHEET: IF: 31
cl 0 111 IQ - 34 5-0 C---*) .5
REVISIONS
NO,
DESCRIPTION DATE
BY
0
FIRST SUBMITTAL
10/15/2007
ESM
1
SECOND SUBMITTAL
01/31/2008
ESM
2
THIRD SUBMITTAL
10/22/2010
ESM
3
FOURTH SUBMITTAL
12/06/2010
ESM
4
MYLARS
12/22/2010
ESM
z
6
z
3
0
U
J
Z
J
"
<
Z
Z
= a
Lu
2
0
z
c
O
T
J
Q
\LLI
/
Q
0,3
0 •
O
W
U
~
Lu
Q
J
(�
0
z
z
12
VL
O
U
J 17
U
J
pill
O N'D
O
c
oa
D a°
N
W®
U
z
C
ss
C
0
-
z
ILJ
C3
co r
o
v o w E
(A N Or
z
-
F-
70 Q
J
- m Inr
( 0
V c
U)
z
:30.
c •> °�
O
a
U
m LL E
0
m�
3 ` L
OY
F`0
obi
c
W
3
Ud
L 8t
l
C/S
ss��NAL,\
JOB NO.: 1352-001-006
DWG.
NAME: ER-01
DESIGNED BY:
KAO
DRAWN BY:
CLC
CHECKED BY:
DATE:
12/22/2010
DATE OF
PRINT:
E R-01
5
OF 31 SHEETS
i
V
0
71
0
0
Z3
w g