Loading...
HomeMy WebLinkAboutWTR2703450.10400 370 A PORTION OF THE NW 1/4 OF SECTION 15, TWP. 23 N., RGE. 5 E., W.M., KING COUNTY, WA%C;I%HINGTON VASHON PL NE SEE SHEET WS-05 MAINTAIN 10 MINIMUM HORIZONTAL SEPARATION BETWEEN WATER AND SEWER 10 12 PAD PAD I EL.=398.75 EL.=396.75 N I + JOINT UTILITY S.S.M.H. #3, TYPE 1 -48" 0 14- TRENCH STA. LT. 0 O o I 0 105+17.99, 0.33' 3 ....•.00 -•..................................... - .. Q 4.L.F. 8"0 PVC S.S-............ ....................................................... co LLJ 153 = w N Z Lu J (W/) _ 105+00 U -I - Q EXISTING SEWER MAIN PER AS -BUILT DWG S-435 TO BE ABANDONED OR REMOVED EXISTING SEWER STUB PER AS -BUILT DWG S-435. CONTRACTOR TO DEFLECT ACCORDINGLY TO CONNECT INTO NEW SYSTEM. PER STD PLAN 407 CONTRACTOR MUST MAINTAIN SERVICE TO SEWER STUB. THICKENED EDGE DRAWING RD-01 NE 2ND PLACE t I TRACT F STORM VAULT 20 ---26 L.F. 8"0 PVC S.S. zi, S.S.M.H. 12, TYPE 1-48"0 ' RT. 105+37.10, 6.36 106+00 -- ---" 104 L.F. 8" 0 PVC S.S. EXISTING 8"• D.I. W.M. PER AS -BUILT DWG #W-505 105+27.99, 11.31' STA. 44.51 STA. 105+26.72. 12.47' RT. RT. STA. 105+29.29, 12.56' RT. 3-8" GATE VALVES (FLXMJ) 1 -8" TEE (FL) CONC. THRUST BLOCKING CUT -IN TEE CONNECTION PER DETAIL 300.4 ON SHEET DT-06 O In N 00 In 00 rn 0 (0 N (0 - cV i a) 0) 0) 0) 0) 0) rn 0) 1`7 P7 NO PC) P7 M 17 ►`� PROPOSED GRADE CAD PROPOSED STORM DRAIN N + - 2.187, O 0 3 Q 4&4--L. F. , 8 "0 153 VC S.S. U) S _ LLJ 0.0442 Z EXISTING 8"O SEWER TO BE REMOVED OR ABANDONED EXISTING 8"0 D.I. W.M. (ASSUMED ELEVATIONS) EXISTING w GRADE ®U- m 1 -_ S.S.M.H. Q. TYPE 1-48"0 � La J STA. 5.20' LT. `= RIM = 395.19 393.60 W C)I.E. = 382.83, 8"4 IN (N w) 382.50 C) I.E. = 302.73, 8"0 OUT (SE) 382.39 Q 20 S=0.0110 -L.F., 8"0 PVC S.S. p T 105+37.10 C C AA W 47 TYPP 1 - EXISTING SEWER STUB PER AS -BUILT DWG S-435. CONTRACTOR TO DEFLECT ACCORDINGLY TO CONNECT INTO NEW SYSTEM. CONTRACTOR MUST MAINTAIN SERVICE TO SEWER STUB. o� �w I m m a n� 00 is - o i i m 0 o� 1 N2 �..�. Call 2 Working Days Before You Dig W =_ 1-800-424-5555 ua Utilities Underground Location Center v o (D,MT,ND,OR,WA) ff a 104+40 CHECKED FOR COMPLIANCE TO CITY STANDARDS HIS - 311 T.G. = 39q.S&- 392.81 I.E. = 382.66, 8"0 IN �w�E 382.17 I.E. _ 3�-8"0 OU ) 382.03 110 184-L.F., 8"0 PVC S.S. 0.0094 S.J.Iv1.n.I, I Ire I--ry w I STA. ' 96;-46..v2�.- 3.98' RT. T.G. = z�- 387.37 381.00 I.E. = 381.25,- 8"0 IN (W 380.81 I.E. = SE) CONTRACTOR TO VERIFY LOCATION AND ELEVATION PRIOR TO CONSTRUCTION. NOTIFY ENGINEER OF ANY DISCREPANCIES. 105+20 105+60 1 SECOND SUBMITTAL 2 THIRD SUBMITTAL 3 FOURTH SUBMITTAL 4 MYLARS 5 CONSTRUCTION SET "J0 REVISION 20' 10' 0 20' 40' SCALE: 1"=2o' HORiz. 1 -10 VERT. Q QI wl � Q I U wlQ REMOVE EXISTING S.S.MH. #2 z AND 8"O PVC S.S. FROM L can I EXISTING S.S.M.H. #2 TO UNION f AVENUE PER CITY OF RENTON I STANDARDS 106+47.19 5.71' S.S.M.H. #1, TYPE 1-48"0 STA 186 3.98' RT. SHALLOW MANHOLE PER STD PLAN 400.2 CONNECT TO EXISTING SS MAIN EXISTING ASPHALT TO REMAIN. SAWCUT AND PATCH AS NEEDED TO CONSTRUCT VAULT AND INSTALL SEWER MAIN. 106+47.19 106+00 106+40 ESM 1/31/200 SURVEYED: ESM 10/22/201 DESIGNED: mm ESM 12/06/201 ESM 12/22/201 DRAWN: ESM 02/24/201 CHECKED: BY DATE APPR APPROVED: SCALE: VERTICAL NAVD 1988 9 HORIZONTAL: NAD 1983/1991 1 •s� ONE INCH DATUM AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY n n � NE 2ND CT z NE ND uj z z uj 6 J CL z i > z Z) NE 2ND PLACE NOTES: 1. FILL AND COMPACT ROADWAY PRISM TO FINISH GRADE PRIOR TO EXCAVATION FOR THE WATERMAIN INSTALLATION. 2. ALL TRENCH RESTORATION SHALL BE PER THE CURRENT CITY OF RENTON TRENCH AND STREET OVERLAY DETAIL. 3. FOR SIDE SEWER CONNECTIONS SEE SIDE SEWER CONNECTION DETAIL SHEET DT-04. SEWER STUBS TO THE PROPERTY LINE SHALL BE 6-INCH MIN. ® 2% MIN. SLOPE. 4. EXISTING MANHOLES AND MAIN TO BE ABANDONED OR REMOVED, IN NE 2ND PLACE. CONTRACTOR MUST MAINTAIN SERVICE TO ALL EXISTING SEWER STUBS OFF EXISTING SEWER MAIN. 5. MAINTAIN WATER AND SEWER SERVICES TO EXISTING HOUSES. RECONNECT EXISTING SIDE SEWERS PER STD PLAN 407 ON SHEET DT-05. VERTICAL DATUM: VERTICAL DATUM IS NAVD 88. PROJECT BENCHMARK IS KING COUNTY CONTROL POINT #6113, POINT NAME RENT1503, PUBLISHED ELEVATION = 401.012 FEET. SEE SHEET HC-01 MAP FOR TEMPORARY BENCHMARK LOCATIONS, TBM 100 - EXISTING RR SPIKE UP 0.1' ON W. FACE OF POWER POLE, ELEVATION = 411.79 FEET TBM 101 - EXISTING 50D NAIL UP 0.5' ON W. FACE OF POWER POLE, ELEVATION = 410.21 FEET SANITARY SIDE SEWERS SEWER STUB MIN. FF DEPTH 0 END ELEV. 0 DOWNSTREAM LOTS ELEV. OF STUB S.S. MAIN S.S.M.H. 12 1 397.75 1 389.60 1 383.57 1 S.S.M.H. #3 W 345010 AS -BUILT CERTIFICATION: I HEREBY DECLARE TO THE BEST OF MY KNOWLEDGE THAT THE INFORMATION SHOWN HEREON REFLECTS THE "AS -CONSTRUCTED CONDITIONS." THIS CERTIFICATION IS BASED UPON WORK PREPARED IN ACCORDANCE WITH GENERAL ACCEPTED PROFESSIONAL ENGINEERING AND/OR S JRVEYI IG PRACj,ICE. JO T N D. KARLEN, L.S NO. 41959 0,16 R CITY OF MLRENTON Planning/Building/Public Works Dept GLADCO DEVELOPMENT, L.L.C. ROSEWOOD HIGHLANDS WATER AND SEWER PLAN AND PROFILE 400 390 oil 370 PAGE DRAWING NO. WS-03 SHEET OF: 19 31 REVISIONS NO. DESCRIPTION/DATE BY 1 SECOND SUBMITTAL ESM 01/31/2008 2 THIRD SUBMITTAL ESM 10/22/2010 3 FOURTH SUBMITTAL ESM 12/06/2010 4 MYLARS 12/22/2010 ESM 5 CONSTRUCTION SET ESM 02/24/2011 6 AS BUILTS 09/12/2011 ESM 7 AS BUILT MYLARS ESM 10/19/2011 z 8 z cn CAI Q 3 QU J J z J L.IL � O z Q cw G 0 Z J O = � J W � w Q w pV) 0 0 p z O Q 3: w W Q Q 0 Z z z w w O U n000 U rnI _j nrnN o y J N O n h p L C C � LLI a� �z vv0 o w ® c Z JJ c Q) - z w Y a) OO 0 o eD O E Z w rn c rn Y O ~ -:� 3 Za C J M (n O to jU 3 U ,� c Z U > 3a` 0,oc1� a 0 U 00 m U m 01 3 .L 3 .Y �0 w 0 �a L sri 42334 O C/STEW ss�ONAL E' JOB NO.: 1352-001-006 DWG. NAME: WS-03 DESIGNED BY: KAO DRAWN BY: CLC CHECKED BY: DATE: 10/19/2011 DATE OF PRINT: WS-03 19 OF 31 SHEETS