Loading...
HomeMy WebLinkAboutWTR2703450.2SEE SHEET WS-01 A PORTION OF THE NW 1 /4 OF SECTION 15, TWP. 23 N., RGE. 5 E., W.M., KING COUNTY, WASHINGTON EXISTING 12"0 C.I. WATER MAIN PER I AS -BUILT DWG #W-245 1 W I I PAD 2 Z ' I EL.=411.25 PAD EL.=409.25 D _j STA. 100+65.75, 23.66' LT. Z gZ of w 1-5 1 /4" FIRE HYDRANT ASSEMBLY FLANGE ELEVATION = 411.31 W 0 3 4" WATER SERVICE Q - \ PER DETAIL 320.1 (TYP) Q0 I o z N r + + O� I -- N -- 3 I 101 EXISTING 12" D.I. I - I - W.M. PER AS -BUILT I DRAWING #W-245 *' - - -7 0 263 L.F. 8"0 iv PVC S.S. r- EXISTING 8"0 D.I. W.M. PER AS -BUILT DWG STA. 100+65.87, 15.90' RT. #W-505 1 -6" GATE VALVE (FLXMJ) S.S.M.H. #5, TYPE 1-48" Ir PER DETAIL 300.1 ON SHEET DT-06 STA 101 +01.60, 2.25' LT. �� 5 v 6n -fAPP IN 61 lf E ( M 3 x F L) 420 410 390 3 � a� N O O T Nm 3v o� nd �o 0 0 N v/, a m w W o CaA 2 Working Days Before You NW 800-424-5555 co Lfthes Underground Location Center (ID MT,ND,OR,WA) a VASHON AVE NE SEE SHEET WS-04 PAD EL.=405.25 I o 3 4 II + I PAD EXISTING SEWER MAIN PER AS -BUILT I EL.=407.25 S-435 TO BE REMOVED OR ABANDONED I BETWEEN EXISTING S.S.M.H #3 AND I UNVERIFIED LOCATION OF EXISTING S.S.C.O.. REPLACE WITH 263 L.F. T EXISTING S.S.C.O. TO BE 8"0 PVC S.S. AS SHOWN. RECONNECT 7 �_T REMOVED EXISTING SIDE SEWERS PER STD PLAN -7 407. MAINTAIN UNINTERUPTED SERVICE TO ' PAD 3 EXISTING HOMES CURRENTLY SERVED. EL.=400.75 = + N a MAINTAIN 10' MINIMUM r + HORIZONTAL SEPARATION - - - - -- - - -___------- BETWEEN WATER AND SEWER 00 ` I I T- N E 2 PLACE EX. S.S.M.H. #3, TO BE REMOVED THICKENED EDGE SEE SHEET RD-01 EXISTING HYDRANT UPGRADE WITH STORTZ ADAPTOR IF EXISTING STORTZ ADAPTOR IS NE 2ND PLACE NOT PRESENT STA. 103+74.97, 14.97' RT. 1-8" TEE (FL) 3-8" GATE VALVES (FLXMJ) CONC. THRUST BLOCKING CUT -IN TEE CONNECTION PER DETAIL 300.4 ON SHEET DT-06 r - O ul) 00 00 n Q C) w 00 il_ r 00 0 O c0 r In M � r7 CV r7 00 O 00 O (D rM 00 r O r _ 't pj Q It CIO � CD It 6 � 4 I M 1- cV � r 't O � pj n 00 n I� r7 C0 r7 O to M M 100+40 100+80 CHECKED FOR COMPLIANCE TO CITY STANDARDS RENTON JOB NO. PROPOSED GRADE 0 EXISTING GRADE 0 1 N _1 S.S.M.H. #5 263 L.F., 8"0 PVC S.S. ® S 0.0491 STA. 101 +01.60, 2.23 LT. �'�� RIM = 409.78 EXISTING 8"0 D.I. W.M. I.E. = 402.88, 6"0 IN (N) (ASSUMED ELEVATIONS) I.E. = 402.78, 8"0 OUT (E) 101 +20 101 +60 102+00 0 FIRST SUBMITTAL 1 SECOND SUBMITTAL 2 THIRD SUBMITTAL 3 FOURTH SUBMITTAL 4 MYLARS NO. REVISION 102+40 102+80 ESM 0/15/200 SURVEYED: ESM 1/31/200 DESIGNED: ESM 0/22/201 ESM 2/06/201 DRAWN: M w ESM 2/22/201 CHECKED: BY DATE I APPR APPROVED: PROPOSED STORM DRAIN a D.D.m.n. #•r. I T ra I - -to w I STA. 103+64.39, 4.21' LT. RIM = 396.87 I.E. = 389.87, 8"0 IN (W N) I.E. = 389.77, 8"0 OUT (E) Fu1 1!llll►� KEY MAP 0 20' 10' 0 20' 40' N 1 "=20' HORIZ. SCALE: � 1"=10' VERT. 0 O r cn Q 3 VERTICAL DATUM: VERTICAL DATUM IS NAVD 88. W PROJECT BENCHMARK IS KING COUNTY CONTROL POINT #6113, POINT NAME RENT1503, W N Z PUBLISHED ELEVATION = 401.012 FEET. J w SEE SHEET HC-01 MAP FOR TEMPORARY BENCHMARK LOCATIONS, Ld U TBM 100 - EXISTING RR SPIKE UP 0.1' ON W. FACE OF POWER POLE, ELEVATION = 411.79 FEET Q TBM 101 - EXISTING 50D NAIL UP 0.5' ON W. FACE OF POWER POLE, ELEVATION = 410.21 FEET S.S.M.H. #4, TYPE 1-48"0 STA. 103+64.39, 4.20' LT. EXISTING 8"0 SEWER TO BE REMOVED OR ABANDONED 103+20 103+60 104+00 SCALE: VERTICAL NAVD 1988 1 *-20 HORIZONTAL: NAD 1983/1991 '�CITY OF (�� � RENTON ONE INCH DATUM AT FULL SCALE Planning/Building/Public Works Dept IF NOT ONE INCH SCALE ACCORDINGLY SANITARY SIDE SEWERS �B MIN. FF DEPTH @ END ELEV. @ DOWNSTREAM LOTS ELEV. OF STUB S.S. MAIN S.S.M.H. 1 412.25 406.44 402.78 S.S.M.H. #5 2 410.25 404.17 400.53 S.S.M.H. #4 3 408.25 401.81 398.35 S.S.M.H. #4 4 406.25 399.08 395.93 S.S.M.H. #4 NOTES: 1. FILL AND COMPACT ROADWAY PRISM TO FINISH GRADE PRIOR TO EXCAVATION FOR THE WATERMAIN INSTALLATION. 2. ALL TRENCH RESTORATION SHALL BE PER THE CURRENT CITY OF RENTON TRENCH AND STREET OVERLAY DETAIL. 3. FOR SIDE SEWER CONNECTIONS SEE SIDE SEWER CONNECTION DETAIL SHEET DT-04. SEWER STUBS TO THE PROPERTY LINE SHALL BE 6-INCH MIN. ® 2% MIN. SLOPE. 4. EXISTING MANHOLES AND MAIN TO BE ABANDONED OR REMOVED, IN NE 2ND PLACE. CONTRACTOR MUST MAINTAIN SERVICE TO ALL EXISTING SEWER STUBS OFF EXISTING SEWER MAIN. 5. MAINTAIN WATER AND SEWER SERVICES TO EXISTING HOUSES. RECONNECT EXISTING SIDE SEWERS PER STD PLAN 407 ON SHEET DT-05. V Do N •3 Q � W Lj = Z� Jw Ld W 345002 GLADCO DEVELOPMENT, L.L.C. ROSEWOOD HIGHLANDS WATER AND SEWER PLAN AND PROFILE 420 410 400 390 PAGE DRAWING NO: WS-02 SHEET: OF: 18 31 REVISIONS NO. DESCRIPTION/DATE BY 0 FIRST SUBMITTAL ESM 10/15/2007 SECOND SUBMITTAL ESM 01/31/2008 2 THIRD SUBMITTAL ESM ,0/22/2010 3 FOURTH SUBMITTAL ESM 12/06/2010 4 MYLARS 12/22/2010 ESM z z 3 0 w J Z 'J U- 0 0- W Q 0_ CL Z 0 =a_ -3 J m W w Q W pC/) 0 0 O Z Q U � 0 W3 w Q U) 0 z z z w O U O uo \1��t4%IItWI _J N C, O r NCO oob C r` CO cr m c oa a Lu z 0 - z w y cl a� o (7 0 00 a E z U) � P �3 �� "J � u) ro 0 (n CO � � V 0 c ro Z c o �a W"0 O 00 V U m IL E - o a i 3 3 oY so 013: c WV 0 a. L Sr 42334 64/ST ° SEAL E� /D JOB NO.: 1352-001-006 DWG. NAME: WS-02 DESIGNED BY: KAO DRAWN BY: CLC CHECKED BY: DATE: 12/22/2010 DATE OF PRINT: WS-02 1 8 OF 31 SHEETS