Loading...
HomeMy WebLinkAboutWTR2703450.3400 390 370 5 EXISTING SEWER MAIN PER AS —BUILT DWG S-435 TO BE ABANDONED OR REMOVED EXISTING SEWER STUB PER AS —BUILT DWG S-435. CONTRACTOR TO DEFLECT ACCORDINGLY TO CONNECT INTO NEW SYSTEM. PER STD PLAN 407 CONTRACTOR MUST MAINTAIN SERVICE TO SEWER STUB. A PORTION OF THE NW 1/4 OF SECTION 15, TWP. 23 N., RGE. 5 E., W.M., KING COUNTY, WASHINGTON VASHON PL NE SEE SHEET WS-05 MAINTAIN 10' MINIMUM HORIZONTAL SEPARATION BETWEEN WATER AND (SEWER 10 12 PAD PAD EL.=398.75 EL.=396.75 S.S.M.H. #3, TYPE 1-48"O STA. 105+ 17.89, 5.20' LT. 154 L.F. 8"0 PVC S.S. --i THICKENED EDGE DRAWING RD-01 NE 2ND PLACE TRACT F STORM VAULT 25 L.F. 8"0 PVC S.S. S.S.M.H. #2, TYPE 1-48"01 STA 105+41.15, 4.65' RT. 106+00 1— * 104 L.F. 8"0 PVC S.S. EXISTING 8"O D.I. W.M. PER AS —BUILT DWG #W-505 STA. 105+28.97, 14.51' RT. 1 —8" TEE (FL) 3-8" GATE VALVES (FLXMJ) CONC. THRUST BLOCKING CUT —IN TEE CONNECTION PER DETAIL 300.4 ON SHEET DT-06 � in N tf) ca N c0 — N PROPOSED GRADE 0 � PROPOSED STORM DRAIN EXISTING 8"0 D.I. W.M. (ASSUMED ELEVATIONS) N + O 0 I 3 154 L.F. " Q 8 sa pVC S.S. S = 0.0452 FT. /FT. V) w = W S.S.M.H. 3 TYPE 1— 48"0 Z STA 105+17 89 20 LT w J RIM = 393.19 W I.E. = 382.83, 8"0 IN (N W) V I.E. = 382.73, 8-0 OUT (SE) 25 L.F., 8"0 PVC S.S. ® S=0.0067 F C C LA W JL7 TYPE 1 -AR" EXISTING SEWER STUB PER AS —BUILT DWG S-435. CONTRACTOR TO DEFLECT ACCORDINGLY TO CONNECT INTO NEW SYSTEM. CONTRACTOR MUST MAINTAIN SERVICE TO SEWER STUB. m o o • 0 N n N� m� Celli 2 Working Days Before YOU Dig � wo W 1-800-424-5555 W " Uffdm LtKierground Location Center (ID,MT,ND,OR,WA) T.G. = 391.68 I.E. = 382,56, 8"0 IN (W I.E. = 382.46, 8"0 OUT E) 104+40 104+80 105+20 CHECKED FOR COMPLIANCE Tn rITY CTAAInARnC RENTON JOB NO. EXISTING 8"0 SEWER TO BE REMOVED OR ABANDONED 105+60 EXISTING uj w GRADE ® LLLL m 0 t 3 S.S.M.H. i1. TYPE 1-48"0 20' 10' 0 20' 40' SCALE: 1 "= 20' HORIZ. 1 =10 VERT. 0 QI w U a <) ; ' Q I REMOVE EXISTING S.S.MH. #2 z AND 8"0 PVC S.S. FROM bi C/) I EXISTING S.S.M.H. #2 TO UNION AVENUE PER CITY OF RENTON STANDARDS S.S.M.H. #1, TYPE 1-48"0 STA 106+ 17.99, 4.15' RT. SHALLOW MANHOLE PER STD PLAN 400.2 CONNECT TO EXISTING SS MAIN EXISTING ASPHALT TO REMAIN. SAWCUT AND PATCH AS NEEDED TO CONSTRUCT VAULT AND INSTALL SEWER MAIN. STA. 106+45.02, 3.98' RT. T.G. = 386.91 I.E. = 381.25, 8"0 IN (W I.E. = 381.15, 8"0 OUT SE) 106+00 106+40 w z J w a 0 FIRST SUBMITTAL ESM 0/15/200 SURVEYED: SCALE: VERTICAL NAVD 19M 1 SECOND SUBMITTAL ESM 1/31/200 1•_2W HORIZONTAL: NAD ,sas/,ss, DESIGNED: 2 THIRD SUBMITTAL ESM 0/22/201 1> 3 FOURTH SUBMITTAL ESM 2/06/201 DRAWN: G.R. ONE INCH DATUM 4 MYLARS ESM 2/22/201 CHECKED: AT FULL SCALE I� DATE NOT ONE INCH N C. REVISION B Y DATE A P P R APPROVED: SCALE ACCORDINGLY n n 2ND CTW �.g z z Z w 4 J Qz O Z Ln N Z > NEE PLACE NOTES: 1. FILL AND COMPACT ROADWAY PRISM TO FINISH GRADE PRIOR TO EXCAVATION FOR THE WATERMAIN INSTALLATION. 2. ALL TRENCH RESTORATION SHALL BE PER THE CURRENT CITY OF RENTON TRENCH AND STREET OVERLAY DETAIL. 3. FOR SIDE SEWER CONNECTIONS SEE SIDE SEWER CONNECTION DETAIL SHEET DT-04. SEWER STUBS TO THE PROPERTY LINE SHALL BE 6—INCH MIN. ® 2% MIN. SLOPE. 4. EXISTING MANHOLES AND MAIN TO BE ABANDONED OR REMOVED, IN NE 2ND PLACE. CONTRACTOR MUST MAINTAIN SERVICE TO ALL EXISTING SEWER STUBS OFF EXISTING SEWER MAIN. 5. MAINTAIN WATER AND SEWER SERVICES TO EXISTING HOUSES. RECONNECT EXISTING SIDE SEWERS PER STD PLAN 407 ON SHEET DT-05. VERTICAL DATUM: VERTICAL DATUM IS NAVD 88. PROJECT BENCHMARK IS KING COUNTY CONTROL POINT #6113, POINT NAME RENT1503, PUBLISHED ELEVATION = 401.012 FEET. SEE SHEET HC-01 MAP FOR TEMPORARY BENCHMARK LOCATIONS, TBM 100 — EXISTING RR SPIKE UP 0.1' ON W. FACE OF POWER POLE, ELEVATION = 411.79 FEET TBM 101 — EXISTING 50D NAIL UP 0.5' ON W. FACE OF POWER POLE, ELEVATION = 410.21 FEET SANITARY SIDE SEWERS SEWER STUB MIN. FF DEPTH ® END ELEV. ® DOWNSTREAM LOTS ELEV. OF STUB S.S. MAIN S.S.M.H. 12 397.75 389.60 383.57 S.S.M.H. #3 >= CITY OF RENTON Planning/Building/Public Works Dept 400 370 w 345003 GLADCO DEVELOPMENT, L.L.C. ROSEWOOD HIGHLANDS FlELDBOOK: PAGE: DRAWING WATER AND SEWER PLAN AND PROFILE S-03 SHEET: OF 19 31 REVISIONS NO. DESCRIPTION/DATE BY 0 FIRST SUBMITTAL ESM 10/15/2007 1 SECOND SUBMITTAL ESM 01/31/2008 2 THIRD SUBMITTAL 10/22/2010 ESM 3 FOURTH SUBMITTAL 12/06/2010 ESM 4 MYLARS 12/22/2010 ESM Z Z FE 3 Q U J z _j J -� QO Ix Z = o ZQ C11.1 c Z IL V —g 0 Za- J w W w Q �j W pcn Oz 0 Q U Ir W LLi Q 0 �R Z Z w w O U now U as J �t J o ii�66t N Obi O r R1 L to Q Ix Z) c o a — 0 U W ®e § z � w C C JJ z W +r M O p (7 ? 0 00 c O E z i � :3 Z� J cr) O in « U (n 0 o C ctt Z w2 m a` O 00— E m 3 3 c °oY 3 C L O c wo >; 0a L sr 4 c/ST%'� JOB NO.: 1352-001-006 DWG. NAME: WS-03 DESIGNED BY: KAO DRAWN BY: CLC CHECKED BY: DATE: 12/22/2010 DATE OF PRINT: WS-03 19 OF 31 SHEETS